header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 90 - 90
1 Nov 2021
Kowalski E Catelli D Lamontagne M Dervin G
Full Access

Introduction and Objective

Gait variability is the amplitude of the fluctuations in the time series with respect to the mean of kinematic (e.g., joint angles) or kinetic (e.g., joint moments) measurements. Although gait variability increases with normal ageing or pathological mechanisms, such as knee osteoarthritis (OA). The purpose was to determine if a patient who underwent a total knee arthroplasty (TKA) can reduce gait variability.

Materials and Methods

Twenty-five patients awaiting TKA were randomly assigned to receive either medial pivot (MP, m=7/f=6, age=62.4±6.2 years) or posterior stabilized (PS, m=7/f=5, age=63.7±8.9 years) implants, and were compared to 13 controls (CTRL, m=7/f=6, age=63.9±4.3 years). All patients completed a gait analysis within one month prior and 12 months following surgery, CTRLs completed the protocol once. A waveform F-Test Method (WFM) was used to compare the variance in knee biomechanics variables at each interval of the gait cycle.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 117 - 117
1 Nov 2018
Catelli D Ng K Kowalski E Beaulé P Lamontagne M
Full Access

Cam-type femoroacetabular impingement (FAI) is a common cause for athletic hip injury and early hip osteoarthritis. Although corrective cam FAI surgery can improve patient reported outcome measures (PROMs), it is not clear how surgery affects muscle forces and hip joint loading. Surgery for FAI may redistribute muscle forces and contact forces at the hip joint during routine activities. The purpose of this study was to examine the muscle contributions and hip contact forces during gait in patients prior and after two years of undergoing surgery for cam FAI. Kinematics and kinetics were recorded in 11 patients with symptomatic cam FAI as they completed a gait task. Muscle and hip contact forces during the stance phase were estimated using musculoskeletal modelling and static optimization in OpenSim. All patients reported improvements in PROMs. Post-operatively, patients showed reduced forces in the long head of the biceps femoris at ipsilateral foot-strike and in the rectus femoris at the contralateral foot-strike. The reduced muscle forces decreased sagittal hip moment but did not change hip contact forces. This was the first study to evaluate hip muscle and contact forces in FAI patients post-operatively. Although hip contact forces are not altered following surgery, muscle forces are decreased even after two years. These findings can provide guidance in optimizing recovery protocols after FAI surgery to improve hip flexor and extensor muscle forces.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 4 - 4
1 Jan 2017
Lamontagne M Kowalski E Catelli D Beaulé P
Full Access

Dual mobility (DM) bearing implants reduce the incidence of dislocation following total hip arthroplasty (THA) and as such they are used for the treatment of hip instability in both primary and revision cases. The aim of this study was to compare lower limb muscle activity of patients who underwent a total hip arthroplasty (THA) with a dual mobility (DM) or a common cup (CC) bearing compared to healthy controls (CON) during a sit to stand task.

A total of 21 patients (12 DM, 9 CC) and 12 CON were recruited from the local Hospital. The patients who volunteered for the study were randomly assigned to either a DM or a CC cementless THA after receiving informed consent. All surgeries were performed by the same surgeon using the direct anterior approach. Participants underwent electromyography (EMG) and motion analysis while completing a sit-to-stand task. Portable wireless surface EMG probes were placed on the vastus lateralis, rectus femoris, biceps femoris, semitendinosus (ST), gluteus medius and tensor fasciae latae muscles of the affected limb in the surgical groups and the dominant limb in the CON group. Motion capture was used to record lower limb kinematics and kinetics. Muscle strength was recorded using a hand-held dynamometer during maximal voluntary isometric contraction (MVIC) testing. Peak linear envelope (peakLE) and total muscle activity (iEMG) were extrapolated and normalized to the MVIC and time cycle for the sit to stand task. Using iEMG, quadriceps-hamstrings muscle co-activation index was calculated for the task. Nonparametric Kruskal Wallace ANOVA tests and Wilcoxon rank sum tests were used to identify where significant (p < 0.05) differences occurred.

The DM group had greater iEMG of the ST muscle compared to the CC (p=0.045) and the CON (p=0.015) groups. The CC group had lower iEMG for hamstring muscles compared to the DM (p=0.041) group. The DM group showed lower quadriceps-hamstrings co-activation index compared to the CON group and it approached significance (p=0.054). The CC group had greater anterior pelvis tilt compared to both DM (p=0.043) and the CON (p=0.047) groups. The DM also had larger knee varus angles and less knee internal rotation compared to both groups, however this never reached significance. No significant differences in muscle strength existed between the groups.

Higher ST muscle activity in the DM group is explained by the reduction in internal rotation at the knee joint as the ST muscle was more active to resist the varus forces during the sit-to-stand task. Reduced quadriceps activity in the CC group is explained by increased pelvic anterior tilt as this would shorten the moment arm and muscle length in the quadriceps, ultimately reducing quadriceps muscle activity. The reduced co-activation between quadriceps and hamstrings activity in the DM group compared to the CC and CON groups is related to better hip function and stability. Combining lower co-activation and larger range of motion for the DM group without impingement, this implant seems to offer better prevention against THA subluxation and less wear of the implant.