header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 142 - 142
1 Feb 2020
Nizam I Batra A Gogos S
Full Access

INTRODUCTION

The Woodpecker pneumatic broaching system facilitates femoral preparation to achieve optimal primary fixation of the stem in direct anterior hip replacement using a standard operating table. The high-frequency axial impulses of the device reduce excess bone tension, intraoperative femoral fractures and overall operating time. The Woodpecker device provides uniformity and enhanced control while broaching, optimizing cortical contact between the femur and implant and thereby maximizing prosthetic axial stability and longevity. This study aims to describe a single surgeon's experience using the Woodpecker pneumatic broaching system in 649 cases of direct anterior approach (DAA) total hip arthroplasties to determine the device's safety and efficacy.

METHODOLOGY

All consecutive patients undergoing elective anterior bikini total hip arthroplasties (THA) performed by a single surgeon between July 2013 and June 2018 were included. Patients undergoing a THA with the use of the Woodpecker device through a different surgical approach, revision THA or arthroplasties for a fractured neck of femur were excluded (n=219). The pneumatic device was used for broaching the femoral canal in all cases. Pre-operative and post-operative Harris Hip Scores (HHS) and post-operative radiographs were analyzed to identify femoral fractures and femoral component positioning at 6 weeks, 6 months and 12 months post-operative. Any intra-operative or post-operative surgical complications and component survivorship until most recent follow up were recorded in the clinical notes.


INTRODUCTION

The primary goal of THA or TKA is to relieve pain and restore mobility. The success is determined by the longevity of prostheses and early return to routine activities, such as driving. With enhanced recovery regimens, patients are being discharged within 24–48hrs post-op.. The aim of this study was to determine when our patients returned to driving after anterior hip replacements and patient specific knee replacements.

METHODOLOGY

This study included 207 soft tissue sparing anterior bikini THA and 146 patient specific instrumented (PSI) TKAs between Feb 2017 and March 2018. All patients included drove before surgery. Non-drivers were excluded. A detailed questionnaire was sent to all patients 3 to 6 weeks after surgery to record their driving status. 50 patients were randomly selected to assess flexion at the hip, knee, and ankle joints whilst seated in the driver's seat of their vehicle.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 143 - 143
1 Apr 2019
Nizam I Batra A
Full Access

BACKGROUND

We conducted this study to determine if the pre-surgical patient specific instrumented planning based on Computed tomography scans can accurately predict each of the femoral and tibial resections. The technique helps in optimization of component positioning and hence overall alignment thereby reducing errors. This makes it less invasive, more efficient and cost effective. The surgical plan in combination with the cutting guides determine the resection thickness, component size, femoral rotation and femoral and tibial component alignment. Several clinical studies have shown that PSI is safe, accurate and reproducible in primary TKA. Accurate preparation of the femoral and tibial surfaces will determine alignment and component positioning and this in turn reflects on function and longevity

METHODS

The study was conducted prospectively between May 2016 and December 2017 in our institution. Patients admitted over a period of these twenty months were included in the study. Patients with primary or secondary osteoarthritis (OA) and inflammatory arthritis who were suitable to undergo patient-specific TKA were included in the study. Patients with conventional instrumented TKR and those with significant deformities requiring constrain including valgus or varus of greater than 20 degrees with incompetent lateral or medial collateral ligaments were excluded from the study along with revisions of partial knee to TKA using PSI blocks.

Prophecy® Preoperative Navigation 3D printed Guides were used for the Evolution Medial Pivot knee replacement system (Microport Orthopaedics (Arlington, TN 38002, USA)) in all cases. The operating surgeon measured all the resections made (4 femoral and 2 tibial) using vernier calipers intraoperatively. These measurements were then compared with the preoperative CT predicted bone resection surgical planning.

The senior author (IN) also designed markings on the tibial cutting blocks to improve accurate placement on the tibia and further markings on the femoral cutting blocks to ensure accurate positioning and rotational alignment improving accuracy of the cuts and femoral rotation. Further markings by senior surgeon (IN) on the pre-operative plans included tibial rotational plans in relation to the tibial tubercle.