header advert
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 30 - 30
1 Apr 2018
Choi W Oh S Kim J Baek S Kim S Lee Y Hwang D
Full Access

Objective

This paper aims to analyze the kinetics of the over-ground wheel-type body weight supporting system (BWS); tendency changes of low extremity joint moment (hip, knee, ankle), 3 axis accelerations of a trunk, cadence and gait velocity as weight bearing level changes.

Method

15 subjects (11 males, 4 females, age:23.63.5, height:170.65.1cm, weight:69.0210.75kg) who had no history of surgery participated. 6 levels (0%, 10%, 20%, 30%, 40% and 50%) of BWS were given to subjects at self-selected gait velocity and kinetic data was calculated using a motion capture system, Vicon® (Vicon, UK).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 67 - 67
1 Feb 2017
Kim J Baek S Kim S
Full Access

Introduction

The mid- or long-term results of acetabular revision total hip arthroplasty (THA) in Korea are rare. The purpose of this study is to report the mid-term radiographic results (> 5 years) of acetabular revision THA with porous-coated cementless Trilogy® cup (Zimmer, Warsaw, IN, USA).

Materials and Methods

Between 1999 and 2010, 77 patients (79 hips) had underwent acetabular revision THA with Trilogy® cup. Eight patients (8 hips) were excluded due to death before 5-year follow-up, and 22 patients (23 hips) were excluded due to less than 5-year follow-up or follow-up loss. Forty-seven patients (48 hips) were included in our study. The mean age was 57.9 years (range, 36 to 76 years) and the mean follow-up was 9.8 years (range 5.0 to 16.2 years). The causes of revision were aseptic loosening in 40 hips, and septic loosening in 8 hips, respectively. Both acetabular and femoral revisions were performed in 14 hips and isolated acetabular revision was done in 34 hips. Preoperetive acetabular bone defect according to Paprosky classification was; 1 in type I, 6 in IIA, 11 in IIB, 9 in IIC, 15 in IIIA, and 6 in IIIB.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 68 - 68
1 Feb 2017
Baek S Kim S Ahn B Nam S
Full Access

Background/Purpose

Cross-linked polyethylene (XLPE) has shown reduced wear rates as compared to conventional polyethylene, but the long-term effect of this on the incidence of osteolysis remains unclear. In addition, the measurement of osteolysis on plain radiographs can underestimate the incidence and extent of osteolysis. Therefore, we evaluated the wear rate, incidence and volume of osteolysis at a minimum follow-up of ten years using three-dimensional computed tomography (3-D CT), a more accurate and sensitive method for detecting and measuring the size of osteolysis than plain radiographs.

Materials and Methods

Between 2000 and 2004, 233 primary THAs were performed using 28-mm cobalt-chrome femoral head on first-generation XLPE (Longevity®, Zimmer, Warsaw, IN) with cups of identical design. Fifty-five patients (57 hips) deceased, eight patients (8 hips) were lost and four patients (4 hips) were revised due to recurrent dislocation (2 hips) or infection (2 hips). Among the remaining 164 hips, 95 hips underwent 3-D CT scanning (Aquilion® 64, Lightspeed Ultra® 16 or Optima® 660) at minimum 10 years (range, 10.0 to 15.2) and were included in this study. Mean age at the time of THA was 56.2 years and average body mass index was 23.5 kg/m2. Average cup size was 55.4 mm whereas mean inclination and anteversion angle of cups on CT scan were 40.1 and 17.4 degrees, respectively. Average follow-up period was 12.8 years. 2D wear rate was measured using PolyWare® 3D Rev 7 software (Draftware Inc, Vevay, IN). Osteolysis was strictly defined as a localized area of trabecular loss with a sclerotic margin. Osteoarthritic cyst and age-related osteoporosis were excluded using perioperative CT scan and magnetic resonance imaging or serial plain radiographs. The incidence, location, and volume of osteolysis were measured.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 23 - 23
1 Feb 2017
Baek S Nam S Ahn B Kim S
Full Access

Background/Purpose

Total hip arthroplasties (THAs) with ceramic bearings are widely performed in young, active patients and thus, long-term outcome in these population is important. Moreover, clinical implication of noise, in which most studies focused on ‘squeaking’, remains controversial and one of concerns unsolved associated with the use of ceramic bearings. However, there is little literature regarding the long-term outcomes after THAs using these contemporary ceramic bearings in young patients. Therefore, we performed a long-term study with a minimum follow-up of 15 years after THAs using contemporary ceramic bearings in young patients with osteonecrosis of the femoral head (ONFH) less than fifty.

Materials and Methods

Among sixty patients (71 hips) with a mean age of 39.1 years, 7 patients (7 hips) died and 4 patients (4 hips) were lost before 15-year follow-up. The remaining 60 hips were included in this study with an average follow-up period of 16.3 years (range, 15 to 18). All patients underwent cementless THA using a prosthesis of identical design and a 28-mm third-generation alumina head by single surgeon. The clinical evaluations included the modified Harris hip score (HHS), history of dislocation and noise around the hip joint: Noise was classified into squeaking, clicking, grinding and popping and evaluated at each follow-up. Snapping was excluded through physical examination or ultrasonography. Radiographic analysis was performed regarding notching on the neck of femoral component, loosening and osteolysis. Ceramic fracture and survivorship free from revision were also evaluated.