Full Access

General Orthopaedics

RADIOGRAPHIC RESULTS OF ACETABULAR REVISION TOTAL HIP ARTHROPLASTY USING POROUS-COATED CEMENTLESS CUP: MINIMUM FIVE-YEAR FOLLOW-UP

The International Society for Technology in Arthroplasty (ISTA), 29th Annual Congress, October 2016. PART 2.



Abstract

Introduction

The mid- or long-term results of acetabular revision total hip arthroplasty (THA) in Korea are rare. The purpose of this study is to report the mid-term radiographic results (> 5 years) of acetabular revision THA with porous-coated cementless Trilogy® cup (Zimmer, Warsaw, IN, USA).

Materials and Methods

Between 1999 and 2010, 77 patients (79 hips) had underwent acetabular revision THA with Trilogy® cup. Eight patients (8 hips) were excluded due to death before 5-year follow-up, and 22 patients (23 hips) were excluded due to less than 5-year follow-up or follow-up loss. Forty-seven patients (48 hips) were included in our study. The mean age was 57.9 years (range, 36 to 76 years) and the mean follow-up was 9.8 years (range 5.0 to 16.2 years). The causes of revision were aseptic loosening in 40 hips, and septic loosening in 8 hips, respectively. Both acetabular and femoral revisions were performed in 14 hips and isolated acetabular revision was done in 34 hips. Preoperetive acetabular bone defect according to Paprosky classification was; 1 in type I, 6 in IIA, 11 in IIB, 9 in IIC, 15 in IIIA, and 6 in IIIB.

Results

Radiolucent lines less than 2mm were found in 2 hips; one in zone I, another in zone I, II, III. Four hips (1 in type IIC, 1 in IIIA and 2 in IIIB) showed cup migration greater than 5 mm accompanying change of position greater than 5 degrees. However, these patients did not complain pain and showed fixation by secondary stabilization. The Kaplan-Meier survivorship with aseptic loosening as the end point at 10 years was 92.6% (95% confidence interval [CI], 82.6 – 100) and at 15 years was 83.8 % (95% CI, 69.1 – 98.6), respectively. Non-recurrent dislocations occurred in 4 hips. There were no other complication such as sciatic nerve palsy, infection and deep vein thrombosis.

Conclusion

Mid-term radiographic results (>5 years) of acetabular revision THA with porous-coated cementless Trilogy® cup showed durable longevity. However, other options such as anti-protrusio cage or cup-cage construct should be considered in severe acetabular bone defect.


*Email: