header advert
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 14 - 14
17 Apr 2023
Bartolo M Newman S Dandridge O Provaggi E Accardi M Dini D Amis A
Full Access

No proven long-term joint-preserving treatment options exist for patients with irreparable meniscal damage. This study aimed to assess gait kinematics and contact pressures of novel fibre-matrix reinforced polyvinyl alcohol-polyethylene glycol (PVA-PEG) hydrogel meniscus implanted ovine stifle joints against intact stifles in a gait simulator.

The gait simulator controlled femoral flexion-extension and applied a 980N axial contact force to the distal end of the tibia, whose movement was guided by the joint natural ligaments (Bartolo; ORS 2021;p1657- LB). Five right stifle joints from sheep aged >2 years were implanted with a PVA-PEG total medial meniscus replacement, fixed to the tibia via transosseous tunnels and interference screws. Implanted stifle joint contact pressures and kinematics in the simulator were recorded and compared to the intact group. Contact pressures on the medial and lateral condyles were measured at 55° flexion using Fujifilm Prescale Low Pressure film inserted under the menisci. 3D kinematics were measured across two 30 second captures using the Optotrak Certus motion-tracking system (Northern Digital Inc.).

Medial peak pressures were not significantly different between the implanted and intact groups (p>0.4), while lateral peak pressures were significantly higher in the implanted group (p<0.01). Implanted stifle joint kinematics in the simulator did not differ significantly from the intact baseline (p>0.01), except for in distraction-compression (p<0.01).

Our findings show that the fibre-matrix reinforced PVA-PEG hydrogel meniscal replacement restored the medial peak contact pressures. Similar to published literature (Fischenich; ABE 2018;46(11):1–12), the lateral peak pressures in the implanted group were higher than the intact. Joint kinematics were similar across groups, with slightly increased internal-external rotation in the implanted group. These findings highlight the effectiveness of the proposed approach and motivate future work on the development of a total meniscal replacement.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 11 - 11
1 Feb 2021
Bartolo M Accardi M Dini D Amis A
Full Access

Objectives

Articular cartilage damage is a primary outcome of pre-clinical and clinical studies evaluating meniscal and cartilage repair or replacement techniques. Recent studies have quantitatively characterized India Ink stained cartilage damage through light reflectance and the application of local or global thresholds. We develop a method for the quantitative characterisation of inked cartilage damage with improved generalisation capability, and compare its performance to the threshold-based baseline approach against gold standard labels.

Methods

The Trainable WEKA Segmentation (TWS) tool (Arganda-Carreras et al., 2017) available in Fiji (Rueden et al., 2017) was used to train two separate Random Forest classifiers to automatically segment cartilage damage on ink stained cadaveric ovine stifle joints. Gold standard labels were manually annotated for the training, validation and test datasets for each of the femoral and tibial classifiers. Each dataset included a sample of medial and lateral femoral condyles and tibial plateaus from various stifle joints, selected to ensure no overlap across datasets according to ovine identifier. Training was performed on the training data with the TWS tool using edge, texture and noise reduction filters selected for their suitability and performance. The two trained classifiers were then applied to the validation data to output damage probability maps, on which a threshold value was calibrated. Model predictions on the unseen test set were evaluated against the gold standard labels using the Dice Similarity Coefficient (DSC) – an overlap-based metric, and compared with results for the baseline global threshold approach applied in Fiji as shown in Figures 1 and 2.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 75 - 75
1 May 2012
Li J Evans S Blain E Piccinelli S Holt C Dini D Accardi M
Full Access

Patient specific knee modelling has the potential to help understand the development of the mechanically induced degenerative disease, Osteoarthritis. A full joint contact model of the knee involves modelling the bones, ligaments, articular cartilage (AC) and meniscus, as well as, the kinematics and geometry of real joints. These finite element models will inevitably require great computational resource to run and it is desirable to find resource effective material model formulations which can accurately describe the mechanical behaviour of the soft tissues. Biphasic models (BIMs) have long been established as an effective formulation for modelling AC. However, the swelling behaviour caused by changes in the ionic phase is a major recovery mechanism and is neglected in the BIMs. It is therefore believed that BIMs alone are insufficient to fully describe the mechanical behaviour of AC. Instead, a thermal analogy method which is generically a BIM that includes the swelling behaviour has been thought to be suitable and has been validated against literature data using material parameters optimized to match the numerical and experimental results. To ensure the model is suitable for patient specific modelling where it will have the ability to reflect the individual AC material properties of the patients in the mechanical behaviour it predicts, two experiments have been planned and are currently being carried out using bovine AC. The first experiment is to investigate the diffusivity of the tissue in solutions of different molarity by measuring the change in tissue weight over time. Eleven explants are taken from the same bovine articular joint using a 6mm biopsy punch and are left in 10mM of PBS overnight to ensure ionic equilibrium has been reached before experiments are carried out. The explants are then placed in PBS solutions of molarities ranging from 0mM to 10mM and weighed at regular time intervals. In the final stage, the explants are then lyophilized and weighed for determining the volume of water in the tissues. Using Archimedes principle, the change in porosity of the tissue is found. A preliminary study has shown that explants submerged in a solution of 5mM has an approximately 4% change in weight after the first 24h and a further 1.73% change in the following 24h. Control specimens left in a solution of 10mM had a 0% change in weight. The second experiment is to carry out mechanical loading on the AC specimens while submerged in a solution of different ion concentrations. Experiments with various loading conditions are being investigated to explore their efficacy for validation. Preliminary compression tests have been carried out where steps of 1% strain was applied, giving a total of 10% strain. Between each step, strain was held constant until full relaxation has been achieved. The reaction force measured from the second experiment in conjunction with data collected from the first experiment will be compared to results predicted in the numerical model. This will allow the determination of whether thermal analogy is adequate or whether more complex triphasic models need to be considered. Furthermore, the development of these experimental methods will contribute to the validation of other AC material models in the future.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 14 - 14
1 May 2012
Accardi M Dini D Lim N Yamamoto K Cann P
Full Access

INTRODUCTION

Osteoarthritis (OA) can be artificially simulated ex vivo on healthy articular cartilage (AC) samples by use of proteolytic enzymes. In this article we will present preliminary analyses of the physical degradation of AC when subjected to alternating mechanical stresses. Since AC damage due to OA is believed to be mechanically induced, the first step towards the realisation of an improved understanding of degenerative behaviour of AC under physiological loading conditions is to perform ex vivo tests which mimic such conditions at best.

METHODS

Porcine AC was subjected to biochemical stimulation or left as native AC. Biochemical degradation was performed using combinations of trypsin and Matrix Metalloproteinases (MMPs) to induce the loss of proteoglycan and collagen. A comparison of the biochemical and mechanical properties, topography and difference in response to mechanical damage between the digested AC and healthy AC was made using White Light Interferometry (WLI), Atomic Force Microscopy (AFM) and mechanical testing. The mechanical damage was induced by subjecting AC to shear under physiological and non physiological conditions. The AC was mechanically tested in a Phosphate Buffered Saline (PBS) bath. After mechanical testing, biochemical analysis of the collagen and aggrecan content of the tissue and PBS present in the bath during the mechanical test was performed. Collagen content was determined by measurement of the amount of hydroxyproline (HPRO), and aggrecan content by the amount of glycosaminoglycans (GAG). The mechanical test was either performed on healthy (native) AC or on AC which had first been digested.