EXPERIMENTAL METHODS FOR VALIDATING ARTICULAR CARTILAGE SWELLING MODELS

British Orthopaedic Research Society (BORS)



Abstract

Patient specific knee modelling has the potential to help understand the development of the mechanically induced degenerative disease, Osteoarthritis. A full joint contact model of the knee involves modelling the bones, ligaments, articular cartilage (AC) and meniscus, as well as, the kinematics and geometry of real joints. These finite element models will inevitably require great computational resource to run and it is desirable to find resource effective material model formulations which can accurately describe the mechanical behaviour of the soft tissues. Biphasic models (BIMs) have long been established as an effective formulation for modelling AC. However, the swelling behaviour caused by changes in the ionic phase is a major recovery mechanism and is neglected in the BIMs. It is therefore believed that BIMs alone are insufficient to fully describe the mechanical behaviour of AC. Instead, a thermal analogy method which is generically a BIM that includes the swelling behaviour has been thought to be suitable and has been validated against literature data using material parameters optimized to match the numerical and experimental results. To ensure the model is suitable for patient specific modelling where it will have the ability to reflect the individual AC material properties of the patients in the mechanical behaviour it predicts, two experiments have been planned and are currently being carried out using bovine AC. The first experiment is to investigate the diffusivity of the tissue in solutions of different molarity by measuring the change in tissue weight over time. Eleven explants are taken from the same bovine articular joint using a 6mm biopsy punch and are left in 10mM of PBS overnight to ensure ionic equilibrium has been reached before experiments are carried out. The explants are then placed in PBS solutions of molarities ranging from 0mM to 10mM and weighed at regular time intervals. In the final stage, the explants are then lyophilized and weighed for determining the volume of water in the tissues. Using Archimedes principle, the change in porosity of the tissue is found. A preliminary study has shown that explants submerged in a solution of 5mM has an approximately 4% change in weight after the first 24h and a further 1.73% change in the following 24h. Control specimens left in a solution of 10mM had a 0% change in weight. The second experiment is to carry out mechanical loading on the AC specimens while submerged in a solution of different ion concentrations. Experiments with various loading conditions are being investigated to explore their efficacy for validation. Preliminary compression tests have been carried out where steps of 1% strain was applied, giving a total of 10% strain. Between each step, strain was held constant until full relaxation has been achieved. The reaction force measured from the second experiment in conjunction with data collected from the first experiment will be compared to results predicted in the numerical model. This will allow the determination of whether thermal analogy is adequate or whether more complex triphasic models need to be considered. Furthermore, the development of these experimental methods will contribute to the validation of other AC material models in the future.