header advert
Results 1 - 12 of 12
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 54 - 54
1 Feb 2020
Ezaki A Sakata K Abe S Iwata H Nannno K Nakai T
Full Access

Introduction

Total knee arthroplasty (TKA) is an effective surgical intervention, which alleviates pain and improves function and health-related quality of life in patients with end-stage arthritis of the knee joint. With improvements in anesthesia, general health care, and surgical techniques, this procedure has become widely accepted for use in very elderly patients. However, many elderly patients tend to have compromised function and low reserve capabilities of organs and are therefore likely to develop various complications during the perioperative period. Thus, elderly patients often hesitate to undergo simultaneous bilateral TKA (SBTKA). Our purpose was to report the short-term results and clinical complications of octogenarians undergoing SBTKA.

Materials and Methods

Between 2015 and 2016 all patients greater than 80years of age who underwent SBTKA by a single surgeon were retrospectively evaluated demographics, comorbidity, complications, and 30days mortality following SBTKA. Arthroplasty was performed sequentially under general anesthesia by one team led by primary surgeon. After the first knee, the patient's cardiopulmonary status was assessed by anesthesiology to determine whether or not to begin the second side. Cardiopulmonary decompensation, such as significant shifts in heart rate, oxygen saturation or blood pressure, was not showed. Then the second procedure was undertaken. Inclusion criteria of this study was underlying diseases were osteoarthritis. Exclusion criteria were (1) previous knee surgery; (2) underlying diseases were osteonecrosis, rheumatoid arthritis, fracture, and others. Fifty-seven patients with an average age of 82.7years were identified. The results of these procedures were retrospectively compared with those of patients greater than 80years of age of 89 patients unilateral TKA (UTKA) that had been performed by the same surgeon.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 126 - 126
1 Feb 2020
Matsukura K Abe S Ito H
Full Access

INTRODUCTION

It has been reported that the rate of complications around the patella after Total Knee Arthroplasty(TKA) is 1–12%, and the patella dislocation is the most common one.

PURPOSE

We will report a case that had the patella dislocation after TKA caused by malrotation of the components.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 57 - 57
1 Feb 2020
Abe S Iwata H Ezaki A Ishida H Sakata K Matsuoka H Sogou E Nannno K Kuroda S Nakamura S Hayashi J Nakai T
Full Access

A-70-year old woman underwent uncomplicated total hip arthroplasty using a titanium modular stem with a 46mm CoCr femoral head, a titanium shell, and a metal linear (Wright Medical Technology). Eight years after implantation, she presented with a painful left hip. A pelvic radiograph revealed adequate positioning of both hip implants without any signs of wear of loosening. CT scanning confirmed the presence of a 5 × 5 cm soft tissue mass in the ilium above the cup component accompanied by the iliac fracture. The patient was diagnosed as having an adverse reaction to metal debris (ARMD) after a metal-on-metal THA and revision was performed. Perioperatively?tissue necrosis and partial destruction of the abductor mechanism were found in the absence of any macroscopic infection. Both the neck trunnion and bore of the head showed slight signs of corrosion. The modular neck was revised with a ceramic 28mm head and a new dual-mobility liner(Zimmer Biomet). The iliac fracture was fixed with a porous trabecular metal augment(Zimmer Biomet).

The histopathology of tissue sample revealed extensively necrotic material with focal cellular areas of inflammatory cells containing macrophages and neutrophilas. Metalic debris was also scattered in the necrotic materials. After the revision, the patient was recovered without pain or dislocation, and iliac fracture was well fixed.

Instability is a substantial problem in the revision of ARMD. Extensive necrosis with gross deficiency of the abductor mechanism is associated with postoperative dislocation. Revision of failed MoM THA a dual-mobility device an effective strategy.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 8 - 8
1 Feb 2020
Abe S Nochi H Ito H
Full Access

Purpose

The purpose of this study is to evaluate stiff knees which have a preoperative arc of motion (AOM) < 65 degrees and maximum flexion < 90 degrees under anesthesia for primary TKA.

Material and Methods

We prospectively evaluated 25 knees, 20 patients, the follow up period was 5±3 years, OA 13, RA 10 and traumatic OA 2 knees. All case were medial para-patella approaches and snip was added in one knee operation, 23 PS-type and 2 constrain-type TKAs.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 145 - 145
1 Apr 2019
Abe S Nochi H Ito H
Full Access

INTRODUCION

Appropriate soft tissue balance is an important factor for postoperative function and long survival of total knee arthroplasty(TKA). Soft tissue balance is affected by ligament release, osteophyte removal, order of soft tissue release, cutting angle of tibial surface and rotational alignment of femoral components. The purpose of this study is to know the characteristics of soft tissue balance in ACL deficient osteoarthritis(OA) knee and warning points during procedures for TKA.

METHODS

We evaluated 139 knees, underwent TKA (NexGen LPS-Flex, fixed surface, Zimmer) by one surgeon (S.A.) for OA. All procedures were performed through a medial parapatellar approach. There were 49 ACL deficient knees. A balanced gap technique was used in 26 ACL deficient knees, and anatomical measured technique based on pre-operative CT was used in 23 ACL deficient knees. To compare flexion-extension gaps and medial- lateral balance during operations between the two techniques, we measured each using an original two paddles tensor (figure 1) at 20lb, 30lb and 40lb, for each knee at a 0 degree extension and 90 degree flexion. We measured bone gaps after removal of all osteophytes and cutting of the tibial surface, then we measured component gaps after insertion of femoral components. Statistical analysis was performed by t-test with significant difference defined as P<0.05.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 34 - 34
1 Apr 2018
Abe S Nochi H Sasaki Y Sato G Ito H
Full Access

INTRODUCTION

The results of modified gap balancing and measured resection technique have been still controversial. We compared PS-type TKAs for osteoarthritis performed using the modified gap technique and the measured resection to determine if either technique provides superior clinical results.

METHODS

The modified gap technique was used in 85 knees, and the measured technique using preoperative CT was used in 70 knees. To compare intra-operative soft tissue balance, bone gap and component gap were measured using original two paddle tensor (20,30,40lb) at 0 degree extension and 90 degrees flexion. To assess the post-operative patella congruency and soft tissue balance, we measured patella tilt, condylar twist angle (CTA) and condylar lift-off angle (LOA) in radiographs. Finally, we evaluated postoperative clinical result (1–5 years) KOOS. Statistical analysis was used by StatView.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 6 - 6
1 May 2016
Abe S Nochi H Ito H
Full Access

Introduction

The systematic effects of joint replacement in rheumatoid arthritis (RA) patients are that inflamed synovium and pathological articular cartilage has dissipated. Expectations of total knee arthroplasty (TKA) are reduction of inflammatory cytokines, decreased disease activity and improvement of drug efficacy and ADL. Remission of rheumatoid arthritis is defined as having a Disease Activity Score DAS28 (ESR) of less than 2.6 and Health Assessment Questionnaire (HAQ) – Disability Index, less than 0.5.

Purpose

We investigated whether TKA could reduce disease activity and improve ADL, and subsequent remission levels of DAS and HAQ or not.


Introduction

Malrotation of a femoral component is a cause of patellofemoral maltracking after total knee arthroplasty (TKA). We have developed a balanced gap technique in posterior stabilized total knee arthroplasty (PS-TKA) using an original tensor instrument. One of characteristics of this instrument is the ability to measure gaps even if there is a bone defect, because it has two paddles, and we can attach block augmentations. In addition it can measure the gap after a reduction of the patella with an offset mechanism. In the balanced gap technique, the femoral component rotation is decided by a tibial cut surface and ligaments balance using the tensor device. This study investigated retrospectively whether rotational alignment of femoral component rotation influenced patellofemoral joint congruency in PS- TKA.

Material and Methods

We evaluated the radiographs of 52 knees of 42 patients, who underwent TKA (NexGen LPS-Flex, fixed surface, Zimmer) by one surgeon (S.A.) for osteoarthritis or rheumatoid arthritis. All procedures were performed through a medial parapatellar approach and a balanced gap technique using a developed versatile tensor device. We measured lateral patella tilt and lateral patella shift at post-op. 6 months. To assess the rotational alignment of femoral component rotation, condylar twist angle (CTA) was measured, and to assess the postoperative flexion gap balance, a condylar lift-off angle (LOA) was measured using the epicondylar view radiographs.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 461 - 461
1 Dec 2013
Nochi H Abe S Ruike T Kobayashi H Ito H
Full Access

Introduction:

The assumption that symmetric extension-flexion gaps improve the femoral condyle lift-off phenomenon and the patellofemoral joint congruity in total knee arthroplasty (TKA) is now widely accepted. For tease reasons, the balanced gap technique has been developed. However, the management of soft tissue balancing during surgery remains difficult and much is left to the surgeon's feel and experience. Furthermore, little is known about the differences of the soft-tissue stiffness (STS) of medial and lateral compartment in extension and flexion in the both cruciate ligaments sacrificed knee. It has a deep connection with the achievement of appropriate gaps operated according to the balanced gap technique. Therefore, the purpose of this study was to analyze the STS of individual compartment in vivo.

Materials and Methods:

The subjects presented 100 osteoarthritic knees with varus deformity underwent primary posterior stabilized (PS) – TKA (NexGen LPS-flex, Zimmer, Warsaw, USA). All subjects completed written informed consent. The patient population was composed of 14 men and 68 women with a mean age of 74.5 ± 7.5 years. The average height, weight, BMI, weight-bearing femorotibial mechanical angle (FTMA), the patella height (T/P ratio), extension and flexion angle of the knee under anesthesia were 151.9 ± 7.8 cm, 62.1 ± 9.4 kg, 26.9 ± 3.7 kg/m2, 167.7 ± 5.6 °, 0.91 ± 0.15 °, −12.0 ± 6.7° and 129.4 ± 13.8°, respectively. After finishing osteotomy and soft tissue balancing, the femoral trial prosthesis was fitted with patello-femoral joint reduction. Then, the medial and lateral compartment gaps (CG) were measured at various distraction forces (89–178 N) using a newly developed versatile tensor device at full extension and 90° flexion positioning, respectively. (Fig. 1) The STS (N/mm) was calculated from a load displacement curve generated by the intra-operative CG data and joint distraction force. Comparisons were made by Wilcoxon signed-ranks test. Correlations were analyzed with Pearson's correlation coefficient. Predictive variables were analyzed with Stepwise regression. A value of p < 0.05 was considered significant.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 462 - 462
1 Dec 2013
Nochi H Abe S Ruike T Kobayashi H Ito H
Full Access

Introduction:

Conventional understanding of knee kinematics suggests that the femoral component should be rotationally aligned parallel to the surgical epicondylar axis (SEA). In contrast, the balanced gap technique suggests the knee be balanced in extension and flexion to achieve proper kinematics and stability of the knee without reference to fixed bony landmarks. To investigate the functional flexion-extension axis (FFEA) when a balanced gap technique was used in the posterior-stabilized total knee arthroplasty (PS-TKA), the relationships between rotational alignment of the femoral component to the postoperative flexion gap balance and to the tibial mechanical axis were evaluated radiographically.

Materials and Methods:

In this prospective study, 63 consecutive knees in 50 patients were included with medial osteoarthritis undergoing a primary PS-TKA (NexGen LPS-Flex, fixed surface, Zimmer; Warsaw, USA). All subjects completed written informed consent. The patient population was composed of 8 men and 42 women with a mean age of 73.0 ± 7.7 years. The average height, weight, BMI, weight-bearing femorotibial mechanical angle (FTMA), condylar twist angle (CTA), and the patella height (T/P ratio) were 150.9 ± 7.2 cm, 62.3 ± 10.1 kg, 27.3 ± 4.0 kg/m2, 167.8 ± 5.5°, 5.9 ± 1.6° and 0.94 ± 0.15, respectively. All procedures were performed through a medial parapatellar approach and a balanced gap technique used a newly developed versatile tensor device. Pre- and post-operatively, the CTA was evaluated using computed tomography (CT). To assess the postoperative flexion gap balance, a condylar lift-off angle (LOA) was evaluated using the epicondylar view radiographs. The FTMA and coronal alignment of the tibial component in reference to the tibial mechanical axis (angle β) were evaluated using plain AP radiography. The FFEA (angle θ) of the knee was calculated as the following; (angle β) + (post-operative CTA) – (LOA). Correlations were analyzed with Pearson's correlation coefficient. Predictive variables were analyzed utilizing Stepwise regression. A value of p < 0.05 was considered significant.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 218 - 218
1 Dec 2013
Abe S Nochi H Kobayashi H Ruike T Ito H
Full Access

Introduction

Malrotation of the femoral component is a cause of patellofemoral maltracking after total knee arthroplasty. We have developed a balanced gap technique in posterior stabilized total knee arthroplasty using an original instrument. Patellar instability is associated with an increased the tibial tubercle and the center of the groove (TT-TG) distance > 20 mm, and TT-TG is regarded as one index of a factor influencing congruity. To assess the influence on a patellofemoral joint by a modified gap technique, the purpose of this study is to compare the TT-TG distance before surgery and after total knee arthroplasty.

Material and Methods

We explored the 30 knees, 25 patients (4 male and 21 female), who underwent total knee arthroplasties (NexGen LPS-Flex, fixed surface, Zimmer; Warsaw, USA) for osteoarthritis or rheumatoid arthritis. All procedures were performed through a medial parapatellar approach and a balanced gap technique used a developed versatile tensor device. We compared the preoperative and postoperative CT at a knee flexion angle of 30 degrees. To assess the force vector of the extensor mechanism, TT-TG distance and the proximal-distal distance between the entrance of the tracheal groove and the tibial tubercle (ET-TT distance) were measured in CT. The relation of both distances (TT-TG index) that divided TT-TG in ET-TT was calculated, because the TT-TG distance was affected by the individual knee size. Three dimensional Q-angle (θ) was also calculated using TT-TG distance and ET-TT distance, sinθ = TT-TG distance/ET-TT distance. (Figure 1)


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 286 - 286
1 Mar 2013
Nochi H Abe S Ruike T Kobayashi H Ito H
Full Access

Introduction

The assumption that symmetric extension-flexion gaps improve the femoral condyle lift-off phenomenon and the patellofemoral joint congruity in total knee arthroplasty (TKA) is now widely accepted. Conventional understanding of knee kinematics suggests that the femoral component should be rotationally aligned parallel to the surgical epicondylar axis (SEA). On the other hand, the theory of the balanced gap technique suggests the knee be balanced in extension and flexion to achieve proper kinematics and stability of the knee without reference to fixed bony landmarks. The purpose of our study was to evaluate the relationship between rotation alignment of the femoral component and postoperative flexion gap balance, and the femoral rotational alignment in relation to the tibial mechanical axis in patients when implanted using a balanced gap technique.

Materials and Methods

The subjects presented 53 consecutive osteoarthritic (OA) varus knees underwent primary Posterior-Stabilised (PS) -TKA (NexGen LPS-flex, Zimmer). All subjects completed written informed consent. The patient population was composed of 7 men and 35 women with a mean age of 72.5 ± 8.3 years. The average height, weight, BMI, weight-bearing FTA, and the patella height (Insall-Salvati ratio: T/P ratio) were 151.7 ± 7.7 cm, 62.6 ± 11.8 kg, 27.2 ± 4.5, 184.9 ± 5.9° and 0.93 ± 0.14 respectively. All procedures were performed through a medial parapatellar approach and a balanced gap technique used a newly developed versatile tensor device which can measure the medial and lateral gaps individually and make use of the balanced gap technique guide with patellofemoral joint reduction, which had been introduced in 56th ORS 2010. Pre- and post-operatively, a condylar twist angle (CTA) was evaluated using computed tomography (CT). To assess the postoperative flexion gap balance, a condylar lift-off angle (LOA) was evaluated using the epicondylar view radiographs by adding a 1.5 kg weight at the ankle. Coronal alignment of the tibial component in reference to the tibial mechanical axis (angle θ) was evaluated using plain AP radiography. Data were expressed as mean ± SD and analysed with Stat View version 5.0.