header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

The Clinical Epicondylar Axis Is Perpendicular to the Tibial Mechanical Axis in Case When a Balanced Gap Technique Is Used in a Posterior-Stabilised Total Knee Arthroplasty

International Society for Technology in Arthroplasty (ISTA) 2012 Annual Congress



Abstract

Introduction

The assumption that symmetric extension-flexion gaps improve the femoral condyle lift-off phenomenon and the patellofemoral joint congruity in total knee arthroplasty (TKA) is now widely accepted. Conventional understanding of knee kinematics suggests that the femoral component should be rotationally aligned parallel to the surgical epicondylar axis (SEA). On the other hand, the theory of the balanced gap technique suggests the knee be balanced in extension and flexion to achieve proper kinematics and stability of the knee without reference to fixed bony landmarks. The purpose of our study was to evaluate the relationship between rotation alignment of the femoral component and postoperative flexion gap balance, and the femoral rotational alignment in relation to the tibial mechanical axis in patients when implanted using a balanced gap technique.

Materials and Methods

The subjects presented 53 consecutive osteoarthritic (OA) varus knees underwent primary Posterior-Stabilised (PS) -TKA (NexGen LPS-flex, Zimmer). All subjects completed written informed consent. The patient population was composed of 7 men and 35 women with a mean age of 72.5 ± 8.3 years. The average height, weight, BMI, weight-bearing FTA, and the patella height (Insall-Salvati ratio: T/P ratio) were 151.7 ± 7.7 cm, 62.6 ± 11.8 kg, 27.2 ± 4.5, 184.9 ± 5.9° and 0.93 ± 0.14 respectively. All procedures were performed through a medial parapatellar approach and a balanced gap technique used a newly developed versatile tensor device which can measure the medial and lateral gaps individually and make use of the balanced gap technique guide with patellofemoral joint reduction, which had been introduced in 56th ORS 2010. Pre- and post-operatively, a condylar twist angle (CTA) was evaluated using computed tomography (CT). To assess the postoperative flexion gap balance, a condylar lift-off angle (LOA) was evaluated using the epicondylar view radiographs by adding a 1.5 kg weight at the ankle. Coronal alignment of the tibial component in reference to the tibial mechanical axis (angle θ) was evaluated using plain AP radiography. Data were expressed as mean ± SD and analysed with Stat View version 5.0.

Results

Extension gap was well balanced within 3 mm in all cases. The average of the preoperative CTA, the postoperative CTA, the LOA and the angle θ. were 6.0 ± 1.5°, 1.2 ± 2.4°, 0.8 ± 1.4° and 89.7 ± 1.2° respectively. No significant correlation was observed in between the postoperative CTA, the LOA and the angle θ. The degree of the clinical epicondylar axis (CEA) to the tibial machanical axis was 90.1 ± 2.9°. Only one knee needed lateral retinaculum release, because of poor patella tracking evaluated by no thumb test or one stitch method.

Discussion

This study demonstrated that our balanced gap technique, using a newly developed tensor device, achieved good patellofemoral joint congruity and balanced flexion gaps postoperatively. Rotation alignment of the femoral component was slight internal rotation in reference to the CEA but not parallel to the SEA.

Conclusion

The CEA was perpendicular to the tibial mechanical axis in PS-TKA with well balanced extension-flexion gap achieved by a balanced gap technique.