Our previous research has demonstrated that minor adjustments to in vitro cellular aggregation parameters, i.e. alterations to aggregate size, can influence temporal and spatial mineral depositions within maturing bone cell nodules. What remains unclear, however, is how aggregate size might affect mineralisation within said nodules over long-term in vivo culture. In this study, we used an osteoblast cell line, MLO-A5, and a primary cell culture, mesenchymal stem cells (MSC), to compare small (approximately 80 µm) with large (approximately 220 µm) cellular aggregates for potential bone nodule development after 8 weeks of culturing in a mouse model (n = 4 each group). In total, 30 chambers were implanted into the intra-peritoneal cavity of 20 male, immunocompromised mice (MF1-Nu/Nu, 4 – 5 weeks old). Nine small or three large aggregates were used per chamber. Neoveil mesh was seeded directly with 2 × 103 cells for monolayer control. At 8 weeks, the animals were euthanised and chambers fixed with formalin. Aggregate integrity and extracellular material growth were assessed via light microscopy and the potential mineralisation was assessed via micro-CT. Many large aggregates appeared to disintegrate, whilst the small aggregates maintained their form and produced additional extracellular material with increased sizes. Both MLO-A5 cells and MSC cells saw similar results. Interestingly, however, the MSCs were also seen to produce a significantly higher volume of dense material compared to the MLO-A5 cells from micro-CT analysis. Overall, a critical cell aggregate size appeared to exist balancing optimal tissue growth with oxygen diffusion, and cell source may influence differentiation pathway despite similar experimental parameters. The MSCs, for example, were likely producing bone via the endochondral ossification pathway, whilst the matured bone cells, MLO-A5 cells, were likely producing bone via the intramembranous ossification pathway.
The aim of this study was to investigate whether the type of cervical disc herniation influences the severity of symptoms at the time of presentation, and the outcome after surgical treatment. The type and extent of disc herniation at the time of presentation in 108 patients who underwent anterior discectomy for cervical radiculopathy were analyzed on MRI, using a four-point scale. These were dichotomized into disc bulge and disc herniation groups. Clinical outcomes were evaluated using the Neck Disability Index (NDI), 36-Item Short Form Survey (SF-36), and a visual analogue scale (VAS) for pain in the neck and arm at baseline and two years postoperatively. The perceived recovery was also assessed at this time.Aims
Methods
We aimed to evaluate the utility of 68Ga-citrate positron emission tomography (PET)/CT in the differentiation of periprosthetic joint infection (PJI) and aseptic loosening (AL), and compare it with 99mTc-methylene bisphosphonates (99mTc-MDP) bone scan. We studied 39 patients with suspected PJI or AL. These patients underwent 68Ga-citrate PET/CT, 99mTc-MDP three-phase bone scan and single-photon emission CT (SPECT)/CT. PET/CT was performed at ten minutes and 60 minutes after injection, respectively. Images were evaluated by three nuclear medicine doctors based on: 1) visual analysis of the three methods based on tracer uptake model, and PET images attenuation-corrected with CT and those not attenuation-corrected with CT were analyzed, respectively; and 2) semi-quantitative analysis of PET/CT: maximum standardized uptake value (SUVmax) of lesions, SUVmax of the lesion/SUVmean of the normal bone, and SUVmax of the lesion/SUVmean of the normal muscle. The final diagnosis was based on the clinical and intraoperative findings, and histopathological and microbiological examinations.Aims
Methods
To develop an early implant instability murine model and explore the use of intermittent parathyroid hormone (iPTH) treatment for initially unstable implants. 3D-printed titanium implants were inserted into an oversized drill-hole in the tibiae of C57Bl/6 mice (n = 54). After implantation, the mice were randomly divided into three treatment groups (phosphate buffered saline (PBS)-control, iPTH, and delayed iPTH). Radiological analysis, micro-CT (µCT), and biomechanical pull-out testing were performed to assess implant loosening, bone formation, and osseointegration. Peri-implant tissue formation and cellular composition were evaluated by histology.Aims
Methods
There is conflicting evidence on the safety of intra-articular injections of hyaluronic acid (HA) or corticosteroids (CSs) before total knee arthroplasty (TKA). We performed a meta-analysis of the relationship between intra-articular injections and subsequent infection rates after TKA. We searched PubMed, EMBASE, and the Cochrane Library for cohort studies that assessed the effect of preoperative injection of drugs into the joint cavity on the infection rate after TKA. The outcomes analyzed included the total infection rate, as well as those for different preoperative injection time periods and different drugs.Aims
Methods
To explore the effect of different durations of antibiotics after stage II reimplantation on the prognosis of two-stage revision for chronic periprosthetic joint infection (PJI). This study involved a retrospective collection of patients who underwent two-stage revision for chronic PJI and continued to use extended antibiotic prophylaxis in two regional medical centres from January 2010 to June 2018. The patients were divided into a short (≤ one month) or a long (> one month) course of treatment based on the duration of antibiotics following stage II reimplantation. The difference in the infection control rate between the two groups was compared, and prognostic factors for recurrence were analyzed.Aims
Methods
Despite the interest in the association of gut microbiota with bone health, limited population-based studies of gut microbiota and bone mineral density (BMD) have been made. Our aim is to explore the possible association between gut microbiota and BMD. A total of 3,321 independent loci of gut microbiota were used to calculate the individual polygenic risk score (PRS) for 114 gut microbiota-related traits. The individual genotype data were obtained from UK Biobank cohort. Linear regressions were then conducted to evaluate the possible association of gut microbiota with L1-L4 BMD (n = 4,070), total BMD (n = 4,056), and femur total BMD (n = 4,054), respectively. PLINK 2.0 was used to detect the single-nucleotide polymorphism (SNP) × gut microbiota interaction effect on the risks of L1-L4 BMD, total BMD, and femur total BMD, respectively.Aims
Methods
MicroRNA-183 ( Clinical samples were collected from patients with OA, and a mouse model of OA pain was constructed by surgically induced destabilization of the medial meniscus (DMM). Reverse transcription quantitative polymerase chain reaction was employed to measure the expression of miR-183, transforming growth factor α (TGFα), C-C motif chemokine ligand 2 (Aims
Methods
Aseptic loosening is a leading cause of uncemented arthroplasty failure, often accompanied by fibrotic tissue at the bone-implant interface. A biological target, neutrophil extracellular traps (NETs), was investigated as a crucial connection between the innate immune system’s response to injury, fibrotic tissue development, and proper bone healing. Prevalence of NETs in peri-implant fibrotic tissue from aseptic loosening patients was assessed. A murine model of osseointegration failure was used to test the hypothesis that inhibition (through Patient peri-implant fibrotic tissue was analyzed for NETs biomarkers. To enhance osseointegration in loose implant conditions, an innate immune system pathway (NETs) was either inhibited (Aims
Methods
Assess and characterise the suitability of a novel silk reinforced biphasic 3D printed scaffold for osteochondral tissue regeneration. Biphasic hybrid scaffolds consisted of 3D printed poly(ethylene glycol)-terephthalate-poly(butylene terephthalate)(PEGT/PBT) scaffold frame work (pore size 0.75mm), which has been infilled with a cast and freeze dried porous silk scaffold (5×5×2mm3), in addition to a seamless silk top layer (1mm). Silk scaffolds alone were used as controls. Both the biphasic and control scaffolds were characterised via uniaxial compression testing (strain rate 0.1mm/min), and the potential biocompatibility of the scaffolds was tested via in vitro culture of seeded bone marrow stromal cells post fabrication.Abstract
Objectives
Methods
Initial post-operative implant instability leads to impaired osseointegration, one of the most common reasons for aseptic loosening and revision surgery. In this study, we developed a novel murine model of implant instability and demonstrated the anabolic effect of immediate and delayed intermittent Parathyroid Hormone (iPTH) treatment in the setting of instability-induced osseointegration failure. 3D-printed titanium implants were inserted in an oversized drill-hole in the tibia of C57Bl/6 mice (n=54). After implantation, the mice were randomly divided in 3 treatment groups (control: PBS-vehicle; iPTH; delayed iPTH). Radiographic analysis was performed to confirm signs of implant loosening. Peri-implant tissue formation was assessed through histology. Osseointegration was assessed through µCT and biomechanical pullout testing.Introduction
Methods
Surgical failure, mainly caused by loosening implants, causes great mental and physical trauma to patients. Improving the physicochemical properties of implants to achieve favourable osseointegration will continue to be the focus of future research. Strontium (Sr), a trace element, is often incorporated into hydroxyapatite (HA) to improve its osteogenic activity. Our previous studies have shown that miR-21 can promote the osteogenic differentiation of mesenchymal stem cells by the PI3K/β-catenin pathway. The aim of this study is to fabricate a SrHA and miR-21 composite coating and it is expected to have a favorable bone healing capability. Ti discs (20 mm diameter and one mm thickness for the in vitro section) and rods (four mm diameter and seven mm length for the in vivo section) were prepared by machining pure Ti. The Ti cylinders were placed in a Teflon-lined stainless-steel autoclave for treating at 150°C for 24 h to form SrHA layer. The miR-21 was encapsulated in nanocapsules. The miR-21 nanocapsules were mixed with CMCS powder to form a gel-like sample and uniformly coated on the SrHA modifed Ti. Osteoblast-like MG63 cells were cultured on SrHA and miR-21 modified Ti, Cell proliferation activity and osteogenesis-related gene expression were evaluated. A bone defect model was established with mature New Zealand to evaluate the osseointegration. Cylindrical holes (four mm in diameter) were created at the distal femur and tibial plateau. Each rabbit was implanted with four of the aforementioned rods (distal femur and tibial plateau of the hind legs). After implantation for one, two and three months, the rabbits were observed by X-ray and scanned using u-CT. Histological and Immunohistochemical analysis were performed to examine the osteogenic markers. A biomechanical push-in test was used to assess the bone-implant bonding strength. Both SrHA nanoparticles with good superhydrophilicity and miR-21 nanocapsules with uniform sizes were distributed evenly on the surface of the Ti. In vitro experiments revealed that the composite coating was beneficial to osteoblast proliferation, differentiation and mineralization. In vivo evaluations demonstrated that this coating could not only promote the expression of angiogenic factor CD31 but also enhance the expression of osteoblastic genes to facilitate angio-osteogenesis. In addition, the composite coating also showed a decreased RANKL expression compared with the miR-21 coating. As a result, the SrHA/miR-21 composite coating promoted new bone formation and mineralization and thus enhanced osseointegration and bone-implant bonding strength. A homogeneous SrHA and miR-21 composite coating was fabricated by generating pure Ti through a hydrothermal process, followed by adhering miR-21 nanocapsules. This coating combined the favorable physicochemical properties of SrHA and miR-21 that synergistically promoted angiogenesis, osteogenesis, osseointegration, bone mineralization and thus bone-implant bonding strength. This study provided a new strategy for surface modification of biomedical implants.
Current treatments of prosthetic joint infection (PJI) are minimally effective against The ability of PlySs2 and vancomycin to kill biofilm and colony-forming units (CFUs) on orthopaedic implants were compared using in vitro models. An in vivo murine PJI model of DAIR was used to assess the efficacy of a combination of PlySs2 and vancomycin on periprosthetic bacterial load.Aims
Methods
PJI is a devastating complication following total joint arthroplasty. In this study, we explore the efficacy of a bacteriophage-derived lysin, PlySs2, against
Introduction
Methods
It is increasingly appreciated that coordinated regulation of angiogenesis and osteogenesis is needed for bone formation. How this regulation is achieved during peri-implant bone healing, such as osseointegration, is largely unclear. This study examined the relationship between angiogenesis and osteogenesis in a unique model of osseointegration of a mouse tibial implant by pharmacologically blocking the vascular endothelial growth factor (VEGF) pathway. An implant was inserted into the right tibia of 16-week-old female C57BL/6 mice (n = 38). Mice received anti-VEGF receptor-1 (VEGFR-1) antibody (25 mg/kg) and VEGF receptor-2 (VEGFR-2) antibody (25 mg/kg; n = 19) or an isotype control antibody (n = 19). Flow cytometric (n = 4/group) and immunofluorescent (n = 3/group) analyses were performed at two weeks post-implantation to detect the distribution and density of CD31hiEMCNhi endothelium. RNA sequencing analysis was performed using sorted CD31hiEMCNhi endothelial cells (n = 2/group). Osteoblast lineage cells expressing osterix (OSX) and osteopontin (OPN) were also detected with immunofluorescence. Mechanical pull-out testing (n = 12/group) was used at four weeks post-implantation to determine the strength of the bone-implant interface. After pull-out testing, the tissue attached to the implant surface was harvested. Whole mount immunofluorescent staining of OSX and OPN was performed to determine the amount of osteoblast lineage cells.Aims
Materials and Methods
The aim of this study was to explore the prognostic factors for postoperative neurological recovery and survival in patients with complete paralysis due to neoplastic epidural spinal cord compression. The medical records of 135 patients with complete paralysis due to neoplastic cord compression were retrospectively reviewed. Potential factors including the timing of surgery, muscular tone, and tumour characteristics were analyzed in relation to neurological recovery using logistical regression analysis. The association between neurological recovery and survival was analyzed using a Cox model. A nomogram was formulated to predict recovery.Aims
Patients and Methods
Poor osseointegration of cementless implants is the leading clinical cause of implant loosening, subsidence, and replacement failure, which require costly and technically challenging revision surgery. The mechanism of osseointegration requires further elucidation. We have recently developed a novel titanium implant for the mouse tibia that maintains in vivo knee joint function and allows us to study osseointegration in an intra-articular, load-bearing environment. Vascular endothelial growth factor (VEGF) is one of the most important growth factors for regulation of vascular development and angiogenesis. It also plays critical roles in skeletal development and bone repair and regeneration. A specialized subset of vascular endothelium, CD31hiEMCNhi cells displaying high cell surface expression of CD31 and Endomucin, has been reported to promote osteoblast maturation and may be responsible for bone formation during development and fracture healing. Because of their potential role in osseointegration, the aim of this study was to use our mouse implant model to investigate the role of VEGF and CD31hiEMCNhi endothelium in osseointegration. Under an IACUC-approved protocol, the implant was inserted into the right tibia of 16-week-old female C57BL/6 mice (N = 38). The mice were then randomized into 2 groups: Control group (N=19) and Anti-VEGFR group (N=19). A cocktail of VEGFR-1 antibody (25mg/kg) and VEGFR-2 antibody (25mg/kg) was given to the mice in the Anti-VEGFR group by intraperitoneal injection every third day starting immediately after surgery until euthanasia. An equivalent amount of an isotype control antibody was given to the control group. Flow cytometric (N = 4/group) and immunofluorescencent (N = 3/group) analyses were performed at 2 weeks post-implantation to detect the distribution and density of CD31hiEMCNhi endothelium in the peri-implant bone. Pull-out testing was used at 4 weeks post-implantation to determine the strength of the bone-implant interface.Introduction
Methods
The incidence of acute Achilles tendon rupture appears to be increasing. The aim of this study was to summarize various therapies for acute Achilles tendon rupture and discuss their relative merits. A PubMed search about the management of acute Achilles tendon rupture was performed. The search was open for original manuscripts and review papers limited to publication from January 2006 to July 2017. A total of 489 papers were identified initially and finally 323 articles were suitable for this review.Objectives
Methods
Poly-lactic acid (PLA) scaffolds are widely used in bone tissue engineering. The introduction of 3D printing has greatly increased the ability for tailoring different geometrical designs of these scaffolds for improved cellular attachment, growth and differentiation. This study aimed to investigate the effect of PLA fibre angle in 3D printed PLA scaffolds on hDPSC attachment and growth Two types of PLA scaffolds were prepared via 3D printing containing fibres angled at either 45° or 90°. hDPSCs (P4, 2*105 cells per scaffold) were statically seeded for 4 hours on to the scaffolds (7×3.5×3 mm3, n=3). Cellular attachment was checked using fluorescence microscopy and the number of unattached cells was counted using a haemocytometer (HCM). The cell-scaffold constructs were then cultured in osteogenic medium for up to 5 weeks. ALP staining and SEM were performed for one construct from each group at week 3. Cellular viability was determined using CMFDA/EHD1 live/dead labelling at week 4. After 5 weeks, constructs were processed for histology. Fluorescence micrographs showed high numbers of hDPSCs attached to scaffold surfaces in both groups after seeding irrespective of fibre angle. However, HCM cell count revealed that the 45° angled PLA scaffolds had significantly greater cell attachment compared to the 90° angled PLA group ( This study showed that 45° angled PLA 3D printed scaffolds enhanced hDPSC attachment and cellular bridging, which may help to rapidly close the macro-pores within the scaffold compared to the 90° angled group. This illustrates the potential of 45° angled 3D printed PLA scaffolds as good candidates for bone tissue engineering.
To investigate the biomechanical mechanism and report preliminary clinical efficacy of eccentric rotational acetabular osteotomy (ERAO) when conduct treatment for developmental dysplasia of the hip (DDH). Biomechanical model of the hip joint was established on six female cadaveric hips embalmed by formalin and stimulate ERAO was then performed on the model. Vertical force was loaded on the cadaveric spine from 0 N to 500 N and strain value on femoral head was measured preoperatively and postoperatively when loading force on spine reached the point of 100, 200, 300, 400 and 500 N. Stress value were then calculated base on the measurements. Besides, we reported postoperative follow up cases which were underwent ERAO to treat DDH in our hospital from July 2007 to October 2014. A total of 25 patients (26 hips) were reported, including 6 males and 19 females. Age varies from 11 to 57 years old, and the average age was 31 years old. Postoperative hip function was evaluated by Harris hip score and anteroposterior X⁃ray of pelvic was taken preoperatively and postoperatively to measure the Acetabular⁃head index (AHI), CE angle and Sharp angle.Objective
Methods
To investigate the biomechanical basis and report preliminary clinical efficacy of eccentric rotational acetabular osteotomy (ERAO) when treating developmental dysplasia of the hip (DDH). Biomechanical model of the hip joint was established on cadaveric hips. After performed ERAO on the biomechanical model, we explored the impact of this surgery on biomechanics of the hip joint. Meanwhile, we reported postoperative follow-up cases who underwent ERAO in our hospital between November 2007 to July 2012. A total of 14 patients (15 hips) were reported, including 4 males and 10 females, mean age was 30 years old. Harris hip score was defined as clinical evaluation standard and radiographic assessment was based on the measurement and further comparison of pre- and post-operative AHI (Acetabular-head index), CE angle (Center-edge angle) and Sharp angle.Objective
Methods
Implant-related infection (IRI) is closely related to the local immunity of peri-implant tissues. The generation of reactive oxygen species (ROS) in activated macrophages plays a prominent role in the innate immune response. In previous studies, we indicated that implant wear particles promote endotoxin tolerance by decreasing the release of proinflammatory cytokines. However, it is unclear whether ROS are involved in the damage of the local immunity of peri-implant tissues. In the present study, we assessed the mechanism of local immunosuppression using titanium (Ti) particles and/or lipopolysaccharide (LPS) to stimulate RAW 264.7 cells. The results indicate that the Ti particles induced the generation of a moderate amount of ROS through nicotinamide adenine dinucleotide phosphate oxidase-1 (NOX-1), but not through catalase. Pre-exposure to Ti particles inhibited ROS generation and extracellular regulated protein kinase (ERK) activation in LPS-stimulated macrophages. These findings indicate that chronic stimulation by Ti particles may lead to a state of oxidative stress and persistent inflammation, which may result in the attenuation of the immune response of macrophages to bacterial components such as LPS. Eventually, immunosuppression develops in peri-implant tissues, which may be a risk factor for IRI.
To test the hypothesis that: CERAMENT[™]|G (C-G) would improve new bone growth and decrease infection rate after debridement as compared with 1) CERAMENT|BONE VOID FILLER (CBVF) and 2) no void filler in a rat osteomyelitis model. 72 Sprague Dawley rats were injected with 1.5 × 10∧6 CFU of S. aureus into a drill hole in the right tibia. After 3 weeks, the osteomyelitic defect was debrided, and filled with either: 1) C-G (n=32), 2) CBVF (n=20), or 3) nothing (n=20). 6 weeks after the second surgery, 20 rats from each group were sacrificed and the right tibias were harvested. A long-term group (n=12) of C-G treated rats were also sacrificed at 6 months after the second surgery. The tissues were sonicated and the colony forming units in the sonicate were quantified by serial dilutions and culture. MicroCT was used to quantify the new bone growth (BV/TV) in the debrided osteomyelitic void. Histological samples were analyzed for the presence of a neutrophil response by a blinded pathologist. (*: p<0.05) Positive cultures in:
○ 30% of animals treated with CBVF ○ 25% of animals treated with no void filler ○ 0% of animals treated with C-G (*) Neutrophil reaction in:
○ 35% of animals treated with CBVF ○ 50% of animals treated with no void filler ○ 0% of animals treated with C-G (*) The BV/TV in:
○ C-G treated rats was 24% greater than CBVF treated rats (*) ○ C-G treated rats was 94% greater than rats treated with no void filler (*) ○ CBVF treated rats was 56% greater than rats treated with no void filler (*) Animals sacrificed at 6 months which were treated with C-G did not have any evidence of infection by culture or histology. The bone mass of the implanted limb was higher than the contralateral (non-operated) side. CERAMENT|G decreased the rate of infection and increased new bone growth as compared with both CBVF and no void filler in a debrided osteomyelitic environment. Animals treated with C-G at 6 months showed no evidence of infection and retained a higher bone mass relative to the contralateral (non-operated) side. This study supports the use of CERAMENT|G as a readily available void filler which could be used in osteomyelitic environments after debridement.
The modulation of both quantity and quality of peri-implant bone with either PTH or loading may be viable options to improve implant fixation and patient outcomes. A strong bone-implant interface is essential for successful joint replacement surgery. This study investigated the differences in bone surrounding and within a porous titanium implant after single or combined treatment with two anabolic bone therapies: intermittent parathyroid hormone (teriparatide) and mechanical loading. Porous titanium implants were inserted bilaterally on the distal lateral femurs of rabbits. The right implant was loaded daily (1 MPa, 50 cycles/day) while the left implant was not. Rabbits received daily PTH injections (20 ug/kg) or saline vehicle. Periprosthetic cancellous bone 0.5, 1.0, and 2.0 mm below the implant surface, bone at the 0.25 mm bone-implant interface and total bone within each implant were examined using tissue-level analyses (quantitative backscattered electron microscopy), cellular analyses (immunohistochemistry staining of osteoblasts with procollagen-1 and TRAP staining of osteoclasts), and shear testing (implant-bone interface). Statistical significance was determined using GEE models (p<0.05). For tissue located 0.5 mm below the implant, significant increases in bone area per total area (BA/TA) were observed with PTH treatment (56%) and with loading (27%). Further, an 18% increase in mineralization density with PTH treatment and a 20% increase in mineralization density with loading was found. Loading effects were not present beyond the 0.5 mm periprosthetic region, but PTH significantly increased BA/TA 2.0 mm below and mineralization density 1.0 mm below the implant. Tissue-level changes were supported by increases in osteoblast activity 0.5 mm below the implant with PTH (79%) and loading (34%), as well as by minimal osteoclast changes. At the 0.25 mm implant-bone interface PTH and loading increased BA/TA (16% and 23%, respectively), but only loading increased mineralization density (7%). Further, total integrated bone area was increased 35% with PTH. Both PTH and loading enhanced the mechanical integrity of the implant-bone; shear strength increased 34% and 60%, respectively. Although combined treatment was not synergistic, both PTH and loading individually enhanced the amount and mineralization density of bone at the implant interface and immediately below the interface, thereby increasing the mechanical strength of the metal-bone interface. This research suggests that modulation of both quantity and quality of peri-implant bone may be viable options to improve implant fixation and patient outcomes.Summary Statement
Improving periprosthetic bone is essential for implant fixation and reducing peri-implant fracture risk. This studied examined the individual and combined effects of iPTH and mechanical loading at the cellular, molecular, and tissue level for periprosthetic cancellous bone. Adult rabbits had a porous titanium implant inserted bilaterally on the cancellous bone beneath a mechanical loading device on the distal lateral femur. The right femur was loaded daily, the left femur received a sham loading device, and half of the rabbits received daily PTH. Periprosthetic bone was processed up to 28 days for qPCR, histology, and uCT analysis. We observed an increase in cellular and molecular markers of osteoblast activity and decrease in adipocytic markers for both treatments, with small additional effects in the combined group. Loading and iPTH led to a decrease and increase, respectively, in osteoclast number, acting through changes in RANKL/OPG expression. Changes in SOST and beta-catenin mRNA levels suggested an integral role for the Wnt pathway. We observed strong singular effects on BV/TV of both loading (1.53 fold) and iPTH (1.54 fold). Combined treatment showed a small additive effect on bone volume. In conclusion, loading and iPTH act through a pro-osteoblastic/anti-adipocytic response and through control of bone turnover via changes in the RANKL/OPG pathway. These changes led to a small additional, but not synergistic, increase in bone volume with the combined therapy.
Angiogenesis and the ability to provide appropriate vascular supply are crucial for skeletal tissue engineering. The aim of this study was to investigate the angiogenic potential of human dental pulp stromal cells (HDPSCs) and stro-1 positive populations as well as their role in tissue regeneration (the clinical reality). HDPSC were isolated from the pulp tissues of human permanent teeth by collagenase digestion. STRO-1 positive cells were enriched using monoclonal anti- STRO-1 and anti- CD45 PE conjugated antibodies together with and fluorescence activated cell sorting (FACS). Cells isolated by FACS were grown to passage4 and cultured as monolayers or on 3D Matrigel scaffold in endothelial cell growth medium-2 (EGM-2) with/without 50ng/mL of vascular endothelial growth factor (VEGF). Cells cultured in alpha MEM supplemented with 10% FCS were used as controls. After 24, 48 and 72 hours angiogenic marker expression (CD31, CD34, vWF and VEGFR-2) was determined by qRT-PCR and immuno-histochemistry. Using three different donors, 0.5-1.5% of total HDPSCs population was characterized as STRO-1+/CD45- cells At each time point cells cultured as monolayer in EGM-2 with VEGF showed up regulation of CD31 and VEGFR-2 expression compared to the control group while expression of CD34 and vWF remained unaffected. However on Matrigel, all four genes were up regulated to different extents. CD31 and VEGFR-2 were up regulated to a greater degree compared to CD34 and vWF. Changes in gene expression in both cell types were time dependent. Immuno-histochemical staining confirmed that the HDPSCs cultured in the test group showed positive staining for the four angiogenic markers (CD31, CD34 vWF and VEGFR-2) when grown in both monolayer and 3D Matrigel culture compared to control cultures. When cultured on Matrigel (but not Monolayer) for 7 days, HDPSC formed tube-like structures in the VEGF treated group. This indicates the potential of use HDPSCs and their STRO-1 positive population for angiogenesis to enhance skeletal tissue repair and/or regeneration toward translational research for clinical benefit.
Stromal cells derived from human dental pulp (HDPSCs) are of current interest for applications in skeletal tissue engineering. Angiogenesis and revascularization of bone grafts or bone constructs HDPSCs, isolated by collagenase digestion, were either maintained as monolayers or dynamically seeded on 3D Bioglass¯ scaffolds and cultured under either basal or osteogenic conditions for 2 and 4 weeks. Expression of osteogenic However when comparing 3D constructs to monolayers:
Human bone marrow stromal cells (HBMSCs) are multipotent and can form bone, cartilage or other tissues under different inductive conditions. The aim of this study was to investigate the effects of enamel matrix derivative (EMD) on the growth and osteogenic differentiation of HBMSCs. HBMSCs were cultured in monolayer with EMD (1, 10, 50,100, 250μg/ml) in aMEM supplemented with 2% FBS for 3 days. Cells cultured in aMEM supplemented with 2% FBS (basal medium) served as the control group. Double-stranded DNA was quantified by PicoGreen assay. Quantitative RT-PCR was performed to determine the expression levels of RUNX2, osteopontin (OPN) and osteocalcin (OCN), dentin matrix protein1 (DMP1) and dentin sialophosphoprotein (DSPP) at different time points (day 0, 5 and 10) when exposed to 10μg/ml EMD or basal medium. Alkaline phosphatase specific activity (ALPSA) was determined after 5 and 10 days culture. Mineral deposition (as calcium) was visualised using Alizarin Red staining.Objective
Methods
P-15 (GTPGPQGIAGQRGVV), a fifteen residue synthetic peptide, is a structural analogue of the cell binding domain of Type 1 collagen and creates a biomimetic environment for bone repair when immobilized on anorganic bovine mineral (ABM) scaffolds. ABM-P-15 scaffolds have been shown to enhance bone marrow stromal cell growth and differentiation. This study aimed at evaluating the osteogenic potential of human dental pulp stromal cells (HDPSCs) compared to human bone marrow stromal cells (HBMSCs) in monolayer and on 3D ABM-P-15 scaffolds in vitro and in vivo. HDPSCs and HBMSCs were cultured as monolayers in basal or osteogenic media for 3 weeks. Osteogenic differentiation was confirmed using alkaline phosphatase (ALP) staining and ALP specific activity (ALPSA). In addition, the presence and distribution of osteogenic markers including Type 1 collagen, bone sialoprotein (BSP), osteopontin (OPN) and osteocalcin (OCN) was determined by immunohistochemisty. Gene expression for COL1, RUNX2 and OCN was determined using RT-PCR after 1, 3 and 5 weeks in basal culture. For 3D culture, HDPSCs were seeded on ABM scaffolds ± P-15 (CeraPedics LLC) and cultured in basal media for 6 weeks. Cell viability and growth were visualized by confocal and scanning electron microscopy. Osteogenic differentiation was confirmed by ALP staining and ALPSA. For in vivo studies, HDPSCs were injected and sealed in diffusion chambers containing ABM-P-15 or ABM alone which were then implanted intraperitoneally in nude mice for 8 weeks. The retrieved samples were then processed for histology.Introduction
Materials and Methods
Articular cartilage has limited regenerative potential. Regeneration via autografts or cell therapy is clinically efficacious but the extent of regenerative success depends upon use of an appropriate cell source. The aim of this study was to compare the proliferative and chondrogenic potentials of three human cell types (human bone marrow stromal cells - HBMSCs, neonatal and adult chondrocytes) commonly used in cartilage tissue engineering. HBMSCs, neonatal and adult chondrocytes (passage 2) were cultured in basal and chondrogenic media. At 2, 4 and 6 days, the cells were analysed for morphology and doubling time. Alkaline phosphatase specific activity (ALPSA) was quantified for each group at 2, 4 and 6 weeks. Chondrogenic potential of each cell type was assessed via a pellet culture model. Cryosections were stained with Alcian blue/Sirius Red. HBMSCs showed either elongated or polymorphic phenotypes, with a doubling time of 40 h. Neonatal chondrocytes showed a uniform spindle shape and had the shortest doubling time (16 h). Adult chondrocytes, were also spindle shaped, though slightly larger than the neonatal cells, with a longer doubling time of 22 h. Expression of ALPSA in basal media was of the order HBMSCs >
adult chondrocytes >
, neonatal chondrocytes. In chondrogenic culture, this order changed to adult chondrocytes >
HBMSCs >
neonatal chondrocytes. In 3D pellet cultures, all three cell types stained positive for Alcian Blue and showed the presence of chondrocyte-like cells enclosed in lacunae. This comparative study suggests that neonatal chondrocytes are the most proliferative with lowest ALP expression. However, in terms of clinical applications, HBMSCs may be better for cartilage regeneration given their lower ALP expression under chondrogenic conditions when compared with adult chondrocytes under the same conditions. The study has provided information to inform clinical cell therapy for cartilage regeneration.
Objective: to analyze influence of propranolol, a beta-blocker, on fracture healing in a mouse model.
The influence of controlled mechanical loading on osseointegration was investigated using an in vivo device implanted in the distal lateral femur of five male rabbits. Compressive loads (1 MPa, 1 Hz, 50 cycles/day, 4 weeks) were applied to a porous coated titanium cylindrical implant (5mm diameter, 2mm width, 75% porosity, 350ìm average pore diameter) and the underlying cancellous bone.. The contralateral limb served as an unloaded control. MicroCT scans at 28 μm resolution were taken of a 4 × 4mm cylindrical region of interest that included cancellous bone below the implant. A scanning electron microscope with a backscattered electron (BSE) detector was used to quantify the percent bone ingrowth and periprosthetic bone in undecalcified sections through the same region of interest. A mixed effects model was used to account for the correlation of the outcome measures within rabbits.. The percent bone ingrowth was significantly greater in the loaded limb (19 +/− 4%) compared to the unloaded control limb (16 +/− 4%, p=0.016) as measured by BSE imaging. The underlying cancellous periprosthetic tissue bone volume fraction was not different between the loaded (0.26 +/− 0.06) and unloaded control limb (0.27 +/− 0.07, p=0.81) by microCT. BSE imaging also showed no difference in the percent area of periprosthetic bone (27 +/− 10% loaded vs. 23 +/− 10% unloaded, p=0.25). Cyclic mechanical loading significantly enhanced bone ingrowth into a titanium porous coated surface compared to the unloaded controls.
A combination of stem cell therapy and tissue engineering is emerging as one of the most promising approaches for skeletal tissue repair and regeneration. Osteoinduction of human bone marrow mesenchymal stem cells (MSCs) is initiated through local signals or growth factors, of which the bone morphogenetic proteins (BMPs) are the best characterised. Cytomodulin-1 (CM-1), a synthetic heptapeptide with functional similarity to members of the TGF-B super family, has been classified as a novel growth factor associated with osteoinduction of MSCs. However, the effects of CM-1 on human bone MSCs are still unclear. The aim of this study was to determine any effects for CM-1 and its scrambled control (CM-1 SCRAM) on the proliferation and differentiation of human bone marrow MSCs along the osteogenic lineage. Primary human bone marrow MSCs were cultured in the presence of CM-1 and CM-1 SCRAM at a range of concentrations (10-8M – 10-6M) in vitro for up to three weeks. 100 ng/mL of recombinant human BMP-2 (rhBMP-2) was used as a positive control. At the end of the culture period, histological and biochemical assays were carried out on the cultures. Biochemical assays revealed that 10-7M of CM-1 significantly stimulated alkaline phosphatase specific activity compared with the negative control group (P<
0.05) in a similar way to the rhBMP-2 positive control group. These data were supported by an observed increase in positive alkaline phosphatase staining in the 10-7M of CM-1 and rhBMP-2 treated cells. However, total DNA content was not significantly different between any of the groups. This study indicated the potential of using CM-1 as an osteogenic growth factor for skeletal tissue regeneration which may provide an alternative approach to meet the major clinical need in orthopaedics and craniofacial surgery. * Cytomodulin-1 and the scrambled control were genuine gifts from Professor (emeritus) Rajendra S. Bhatnagar at the Department of Bioengineering, University California Berkley, USA.
The use of designer scaffolds to deliver biologically active osteogenic growth factors such as recombinant human bone morphogenetic protein-2 (rhBMP-2) to the sites of tissue regeneration in for example orthopaedics, has tremendous therapeutic implications. The aims of this study were to generate biomimetic biodegradable porous osteogenic scaffolds using a supercritical fluid process to encapsulate rhBMP-2, and to examine the ability of the scaffolds to promote human osteoprogenitor differentiation and bone formation in vitro and in vivo. The rhBMP-2 encapsulated in Poly(-lactic acid) (PLA) scaffolds (100ng/mg PLA) were generated using an innovative supercritical fluid mixing method. The bioactivity of rhBMP-2 encapsulated PLA scaffolds were confirmed by induction of the C2C12 promyoblast cell line into the osteogenic lineage as detected by alkaline phosphatase expression. No induction of alkaline phosphatase-positive cells was observed using blank scaffolds. BMP-2 released from encapsulated constructs promoted adhesion, migration, expansion and differentiation of human osteoprogenitor cells on 3-D scaffolds. Enhanced matrix synthesis and cell differentiation on growth factor encapsulated scaffolds was observed following culture of human osteoprogenitors on explants of chick femoral bone wedge defects in an ex vivo model of bone formation developed using the chick chorioallantoic membrane model. In vivo studies using diffusion chamber implantation and subcutaneous implantation of human osteoprogenitors on rhBMP-2 encapsulated scaffolds showed morphologic evidence of new bone matrix and cartilage formation in athymic mice as assessed by x-ray analysis, immunocytochemistry and birefringence. These studies provide evidence of controlled release of BMP-2 from biodegradable polymer scaffolds initiating new bone formation in vivo. The generation of 3-D biomimetic structures incorporating osteoinductive factors such as BMP-2 indicates their potential for de novo bone formation that exploits cell-matrix interactions and, significantly, realistic delivery protocols for growth factors in musculo-skeletal tissue engineering.
The formation of biomimetic environments using scaffolds containing cell recognition sequence and osteo-inductive factors in combination with bone cells offers tremendous potential for bone and cartilage regeneration. In tissues, collagen forms the scaffold by mediating the flux of chemical and mechanical stimuli. Recently, a synthetic 15-residue peptide P-15, related biologically to the active domain of type I collagen, has been found to promote attachment and the osteoblast phenotype of human dermal fibroblasts and periodontal ligament fibroblasts on particulate anorganic bone mineral (ABM). The aim of this study was to exam the ability of the collagen peptide, P-15, to promote human osteoprogenitor attachment, proliferation and differentiation on cell culture surfaces and 3-D scaffolds. Selected human bone marrow cells were cultured on particulate microporous anorganic bone mineral (‘pure ‘ hydroxyapatite based on x-ray diffraction standard JCPDS9-432) phase and polygalactin vicryl mesh adsorbed with or without P-15 in basal or osteogenic conditions. Cell adhesion, spreading and patterning were examined by light and confocal microscopy following incorporation of cell tracker green and ethidium homodimer fluorescent labels. Osteoprogenitor proliferation and differentiation was assessed by DNA content and alkaline phosphatase specific activity. Growth and differentiation on 3-D ABM structures were examined by confocal and scanning electron microscopy (SEM). P-15 promoted human osteoprogenitor cell attachment and patterning on particulate bovine anorganic bone mineral phase and polygalactin vicryl mesh over 5–24 hours compared to culture on ABM and vicryl mesh alone as observed by photomicroscopy. Increased alkaline phosphatase specific activity was enhanced following culture on P-15 adsorbed matrices as recognized by enhanced expression of alkaline phosphatase, type I collagen, osteocalcin and cfba-1. The presence of mineralised bone matrix and extensive cell ingrowth and cellular bridging between 3-D ABM matrices and polygalactin vicryl mesh adsorbed with P-15 was observed by confocal microscopy and alizarin red staining. SEM confirmed the 3-D structure of newly formed cell constructs and cellular ingrowth on and between the P-15 modified inorganic bone mineral materials. Negligible cell growth was observed on ABM alone or polygalactin vicryl mesh alone. These observations demonstrate that the synthetic 15-residue collagen peptide, P-15, when adsorbed to ABM or polygalactin vicryl mesh, can stimulate human osteoprogenitor attachment and spreading. They also demonstrated that P-15 coupled 3-D matrices stimulate human osteoprogenitor differentiation and materialisation. The studies indicate that a synthetic analogue of collagen provides a biomimetic environment supportive for cell differentiation and tissue regeneration and indicate a potential for the use of extracellular matrix cue in the development of biomimetic environments for bone tissue engineering.
Ex vivo gene transfer of osteogenic factors into multipotential stem cells offers potentially important therapeutic implications in a variety of musculoskeletal diseases. One possible approach is the development of a cellular vehicle, namely bone morphogenetic protein (BMP)-producing bone marrow cells, created using adenoviral gene transfer. These transduced cells provide local delivery of BMP for bone formation. The aims of this study were to study the feasibility of gene transfer to human bone osteoprogenitor cells, using adenoviral vectors. Specifically, the aims were to study the efficacy of transduction with an adenoviral vector expressing BMP-2 and then to determine the ability of the transduced cells to produce active BMP-2 and to generate bone ex vivo. Primary human bone marrow osteoprogenitor cells were expanded in culture and infected with AxCALacZ, a replication-deficient adenoviral vector carrying the To examine whether adenoviral transfection affected the osteoblast phenotype and their ability to mineralise in vitro, adenovirally-transduced bone marrow cells expressing BMP-2 were seeded onto poly(-lactic acid These results indicate the ability to deliver active BMP-2 using human bone marrow osteoprogenitor cells following adenoviral infection. The maintenance of osteoblast phenotype in extended culture and generation of mineralised 3-D scaffolds containing such constructs offers a realistic approach to tissue engineer bone for orthopaedic applications.