header advert
Results 1 - 32 of 32
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 25 - 31
1 May 2024
Yasunaga Y Oshima S Shoji T Adachi N Ochi M

Aims

The objective of this study was to present the outcomes of rotational acetabular osteotomy (RAO) over a 30-year period for osteoarthritis (OA) secondary to dysplasia of the hip in pre- or early-stage OA.

Methods

Between September 1987 and December 1994, we provided treatment to 47 patients (55 hips) with RAO for the management of pre- or early-stage OA due to developmental hip dysplasia. Of those, eight patients (11 hips) with pre-OA (follow-up rate 79%) and 27 patients (32 hips) with early-stage OA (follow-up rate 78%), totalling 35 patients (43 hips) (follow-up rate 78%), were available at a minimum of 28 years after surgery.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 15 - 15
1 Jul 2022
Putnis S Klasan A Oshima T Grasso S Neri T Coolican M Fritsch B Parker D
Full Access

Abstract

Introduction

MRI has been increasingly used as an outcome measure and proxy for healing and integration after ACL reconstruction (ACLR). Despite this, it has not yet been established what a steady state graft MRI appearance is.

Methodology

MRI and clinical outcome measures were prospectively taken at 1 and minimum 2 years after hamstring autograft ACLR. MRI graft signal was measured using novel reconstructions both parallel and perpendicular to the graft, with lower signal indicative of better healing and expressed as the signal intensity ratio (SIR), and tunnel apertures analysed.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 39 - 39
1 Feb 2020
Suda Y Muratsu H Hiranaka Y Tamaoka T Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Introduction

The influences of posterior tibial slope on the knee kinematics have been reported in both TKA and UKA. We hypothesized the posterior tibial slope (PTS) would affect the sagittal knee alignment after UKA. The influences of PTS on postoperative knee extension angle were investigated with routine lateral radiographies of the knee after UKA.

Materials & Methods

Twenty-four patients (26 knees; 19 females, 7 males) underwent medial UKA were involved in this study. Average age was 74.8 ± 7.2 years. The mean preoperative active range of motion were − 4.1° ± 6.3°in extension and 123.2° ± 15.5° in flexion. All UKAs were performed using fixed bearing type UKA (Zimmer Biomet, ZUK), with adjusting the posterior slope of the proximal tibial bone cut according to the original geometry of the tibia. Routine lateral radiographies of the knee were examined preoperatively, 6 months after the surgery. PTS and knee extension angles with maximal active knee extension (mEXT) and one-leg standing (sEXT) were radiographically measured. We used the fibular shaft axis (FSA) for the sagittal mechanical axis of the tibia. PTS was defined as the angle between the medial tibial plateau and the perpendicular axis of FSA. Extension angles (mEXT and sEXT) were defined as the angles between FSA and distal femoral shaft axis (positive value for hyperextension). The changes of PTS and the influences of PTS on sEXT at each time period were analyzed using simple linear regression analysis (p<0.05).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 125 - 125
1 Feb 2020
Iizawa N Oshima Y Kataoka T Majima T Takai S
Full Access

Background

In order to restore the neutral limb alignment in total knee arthroplasty (TKA), surgical procedure usually starts with removing osteophytes in varus osteoarthritic knees. However, there are no reports in the literature regarding the exact influence of osteophyte removal on alignment correction. The purpose of this study was to define the influence of osteophyte removal alone on limb alignment correction in the coronal plane in TKA for varus knee.

Methods

Twenty-eight medial osteoarthritic knees with varus malalignment scheduled for TKA were included in this study. After registration of a navigation system, each knee was tested at maximum extension, and at 30, 40 and 60 degrees of flexion before and after osteophyte removal. External loads of 10 N-m valgus torque at each angle and in both states were applied. Subsequently, the widths of the resected osteophytes were measured.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 55 - 55
1 Feb 2020
Oshima Y Watanabe N Takeoka T Iizawa N Majima T Takai S
Full Access

Introduction

Upright body posture is maintained with the alignment of the spine, pelvis, and lower extremities, and the muscle strength of the body trunk and lower extremities. Conversely, the posture is known to undergo changes with age, and muscle weakness of lower extremities and the restriction of knee extension in osteoarthritis of the knee (knee OA) have been considered to be associated with loss of natural lumbar lordosis and abnormal posture.

As total knee arthroplasty (TKA) is aimed to correct malalignment of lower extremities and limited range of motion of knee, particularly in extension, we hypothesized that TKA positively affects the preoperative abnormal posture. To clarify this, the variation in the alignment of the spine, pelvis, and lower extremities before and after TKA was evaluated in this study.

Patients and methods

Patients suffering from primary knee OA who were scheduled to receive primary TKA were enrolled in this study. However, patients with arthritis secondary to another etiology, i.e. rheumatoid arthritis, trauma, or previous surgical interventions to the knee, were excluded. Moreover, patients who suffered from hip and ankle OA, cranial nerve diseases, or severe spinal deformity were also excluded.

The sagittal vertical axis (SVA), the horizontal distance between the posterosuperior aspect of the S1 endplate surface and a vertical plumb line drawn from the center of the C7 vertebral body, is an important index of sagittal balance of the trunk. Thus, patients were classified into two groups based on the preoperative SVA with preoperative standing lateral digital radiographs: normal (< 40mm) and abnormal (≥ 40mm) groups.

The variations in the sagittal alignment of the spine, pelvis and lower extremities were evaluated preoperatively, and at 1 and 3 months postoperatively. This study was approved by an institutional review board, and informed consent for participation was obtained from the patients.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 38 - 38
1 Feb 2020
Tamaoka T Muratsu H Tachibana S Suda Y Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Introduction

Patients-reported outcome measures (PROMs) have been reported as the important methods to evaluate clinical outcomes in total knee arthroplasty (TKA). The patient satisfaction score in Knee Society Score (KSS-2011) has been used in the recent literatures. Patient satisfaction was subjective parameter, and would be affected by multiple factors including psychological factors and physical conditions at not only affected joint but also elsewhere in the body. The question was raised regarding the consistency of patient satisfaction score in KSS-2011 to other PROMs.

The purpose of this study was to investigate the correlation of patient satisfaction in KSS-2011 to other categories in KSS-2011 and to other PROMs including Forgotten Joint Score (FJS-12), EuroQol-5 Dimensions (EQ-5D) and 25-questions in Geriatric Locomotive Function Scale (GLFS-25).

Material & Method

83 patients over 65 years old with osteoarthritic knees were involved in this study. All patients underwent CR-TKAs (Persona CRR). The means and ranges of demographics were as follows: age; 74.5 years old (65–89), Hip-Knee-Ankle (HKA) angle; 12.4 (−6.2–22.5) in varus. We asked patients to fulfill the questionnaire including KSS-2011, FJS-12, EQ-5D and GLFS-25 at 1-year postoperative follow-up visit. KSS-2011 consisted of 4 categories of questions; patient satisfaction (PS), symptoms, patient expectations (PE), functional activities (FA).

We evaluated the correlation of PS to other PROMs using simple linear regression analyses (p<0.001).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 84 - 84
1 Apr 2019
Tachibana Muratsu Kamimura Ikuta Oshima Koga Matsumoto Maruo Miya Kuroda
Full Access

Background

The posterior slope of the tibial component in total knee arthroplasty (TKA) has been reported to vary widely even with computer assisted surgery. In the present study, we analyzed the influence of posterior tibial slope on one-year postoperative clinical outcome after posterior-stabilized (PS) -TKA to find out the optimal posterior slope of tibial component.

Materials and Method

Seventy-three patients with varus type osteoarthritic (OA) knees underwent PS-TKA (Persona PSR) were involved in this study. The mean age was 76.6 years old and preoperative HKA angle was 14.3 degrees in varus. Tibial bone cut was performed using standard extra-medullary guide with 7 degrees of posterior slope.

The tibial slopes were radiographically measured by post-operative lateral radiograph with posterior inclination in plus value. The angle between the perpendicular line of the proximal fibular shaft axis and the line drawn along the superior margin of the proximal tibia represented the tibial slope angle. We assessed one-year postoperative clinical outcomes including active range of motion (ROM), patient satisfaction and symptoms scores using 2011 Knee Society Score (2011 KSS).

The influences of posterior tibial slope on one-year postoperative parameters were analyzed using simple linear regression analysis (p<0.05).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 80 - 80
1 Apr 2019
Ikuta Muratsu Kamimura Tachibana Oshima Koga Matsumoto Maruo Miya Kuroda
Full Access

Introduction

Modified gap technique has been reported to be beneficial for the intraoperative soft tissue balancing in posterior-stabilized (PS) -TKA. We have found intraoperative ligament balance changed depending on joint distraction force, which might be controlled according to surgeons' fells.

We have developed a new surgical concept named as “medial preserving gap technique (MPGT)” to preserve medial knee stability and provide quantitative surgical technique according to soft tissue balance measurement using a tensor device.

The purpose of this study was to compare 3-years postoperative knee stability after PS-TKA in varus type osteoarthritic (OA) knees between MPGT and measured resection technique (MRT).

Material & Method

The subjects were 94 patients underwent primary unilateral PS-TKA for varus type OA knees. The surgical technique was MPGT in 47 patients and MRT in 47 patients.

An originally developed off-set type tensor device was used to evaluate intraoperative soft tissue balance. In MPGT, medial release was limited until the spacer block corresponding to the bone thickness from proximal lateral tibial plateau could be easily inserted. Femoral component size and external rotation angle were adjusted depending on the differences of center gaps and varus angles between extension and flexion before posterior femoral condylar resection.

The knee stabilities at extension and flexion were assessed by stress radiographies at 1 and 3 years after TKA; varus-valgus stress test at extension and stress epicondylar view at flexion. We measured medial and lateral joint openings (MJO, LJO) at both knee extension and flexion.

MJOs and LJOs at 2 time periods were compared in each group using paired t-test. Each joint opening distance was compared between 2 groups using unpaired t-test. The significance level was set as P < 0.05.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 91 - 91
1 Apr 2019
Watanabe H Majima T Tsunoda R Oshima Y Uematsu T Takai S
Full Access

Introduction

The hip hemiarthroplasty in posterior approach is a common surgical procedure at the femoral neck fractures in the elderly patients. However, the postoperative hip precautions to avoid the risk of dislocations are impeditive for early recovery after surgery. We used MIS posterior approach lately known as conjoined tendon preserving posterior (CPP) approach, considering its enhancement of joint stability, and examined the intraoperative and postoperative complications, retrospectively.

Methods

We performed hip hemiarthroplasty using CPP approach in 30 patients, and hip hemiarthroplasty using conventional posterior approach in 30 patients, and both group using lateral position with the conventional posterior skin incision. The conjoined tendon (periformis, obturator internus, and superior/inferior gemellus tendon) was preserved and the obturator externus tendon was incised in CPP approach without any hip precautions postoperatively. The conjoined tendon was incised in conventional approach using hip abduction pillow postoperatively.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 41 - 41
1 Apr 2018
Kamimura M Muratsu H Kanda Y Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Introduction

Both measured resection technique and gap balancing technique have been important surgical concepts in total knee arthroplasty (TKA). Modified gap technique has been reported to be beneficial for the intra-operative soft tissue balancing in posterior-stabilizing (PS) -TKA.

On the other hand, we have found joint distraction force changed soft tissue balance measurement and medial knee instability would be more likely with aiming at perfect ligament balance at extension in modified gap technique. The medial knee stability after TKA was reported to essential for post-operative clinical result.

We have developed a new surgical concept named as “medial preserving gap technique” for varus type osteoarthritic (OA) knees to preserve medial knee stability and provide quantitative surgical technique using tensor device.

The purpose of this study was to compare post-operative knee stability between medial preserving gap technique (MPGT) and measured resection technique (MRT) in PS-TKA.

Material & Method

The subjects were 140 patients underwent primary unilateral PS-TKA for varus type OA knees. The surgical technique was MPGT in 70 patients and MRT in 70 patients. There were no significant differences between two groups in the pre-operative clinical features including age, sex, ROM and deformity.

Originally developed off-set type tensor device was used to evaluate both center gap and varus angle with 40 lbs. of joint distraction force. The extension gap preparation was identical in both group. In MPGT group, femoral component size and external rotation angle were adjusted depending on the differences of center gaps and varus angles between extension and flexion before posterior femoral condylar osteotomy.

The knee stabilities at extension and flexion were assessed by stress radiographies; varus-valgus stress test with extension and stress epicondylar view with flexion, at one-month and one-year after TKA. We measured joint opening distance (mm) at medial and lateral compartment at both knee extension and flexion.

Joint opening distances were compared between two groups using unpaired t-test, and the difference between medial and lateral compartment in each group was compared using paired t- test (p<0.05).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 42 - 42
1 Apr 2018
Watanabe S Muratsu H Yahiro S Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Background

Knee osteoarthritis (OA) is a major cause of ambulatory disabilities. Although total knee arthroplasty (TKA) has been reported as the most effective treatment for severe knee OA, quantitative evaluation of ambulatory function have not been well investigated.

We hypothesized that better functional recovery would result in better patient satisfaction. The purpose of this study was to quantitatively evaluate ambulatory functional recovery and assess the influence on patient satisfaction after TKA.

Material and Methods

90 patients (80 females and 10 males) were involved in this study. The mean age at TKA was 75.2 ± 5.8 years. Patients were subjected to 3 meters timed up and go test (TUG) to evaluate ambulatory function. TUG was performed at 6 time periods; before surgery, 2 weeks, 1, 3, 6 months, and 1 year after surgery. We also asked the patients to fill out the questionnaire of patient satisfaction category in the New Knee Society Score at 1 year after TKA.

The sequential changes in TUG were analyzed using repeated measures ANOVA (p<0.05). The influences of each parameter (age, TUGs) on the patient satisfaction score were analyzed with simple regression analysis (p<0.05).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 52 - 52
1 Apr 2018
Sawauchi K Muratsu H Kamenaga T Oshima T Koga T Matsumoto T Maruo A Miya H Kuroda R
Full Access

Background

In recent literatures, medial instability after TKA was reported to deteriorate early postoperative pain relief and have negative effects on functional outcome. Furthermore, lateral laxity of the knee is physiological, necessary for medial pivot knee kinematics, and important for postoperative knee flexion angle after cruciate-retaining total knee arthroplasty (CR-TKA). However, the influences of knee stability and laxity on postoperative patient satisfaction after CR-TKA are not clearly described.

We hypothesized that postoperative knee stability and ligament balance affected patient satisfaction after CR-TKA. In this study, we investigated the effect of early postoperative ligament balance at extension on one-year postoperative patient satisfaction and ambulatory function in CR-TKAs.

Materials & Methods

Sixty patients with varus osteoarthritis (OA) of the knee underwent CR-TKAs were included in this study. The mean age was 73.6 years old. Preoperative average varus deformity (HKA angle) was 12.5 degrees with long leg standing radiographs.

The knee stability and laxity at extension were assessed by stress radiographies; varus-valgus stress X-ray at one-month after operation. We measured joint separation distance (mm) at medial compartment with valgus stress as medial joint opening (MJO), and distance at lateral compartment with varus stress as lateral joint opening (LJO) at knee extension position. To analyze ligament balance; relative lateral laxity comparing to the medial, varus angle was calculated.

New Knee Society Score (NKSS) was used to evaluate the patient satisfaction at one-year after TKA.

We measured basic ambulatory functions using 3m timed up and go test (TUG) at one-year after surgery.

The influences of stability and laxity parameters (MJO, LJO and varus angle at extension) on one-year patient satisfaction and ambulatory function (TUG) was analyzed using single linear regression analysis (p<0.01).


Introduction

A femoral rotational alignment is one of the essential factors, affecting the postoperative knee balance and patellofemoral tracking in total knee arthroplasty (TKA). To obtain an adequate alignment, the femoral component must be implanted parallel to the surgical epicondylar axis (SEA).

We have developed “a superimposable Computed Tomography (CT) scan-based template”, in which the SEA is drawn on a distal femoral cross section of the CT image at the assumed bone resection level, to determine the precise SEA. Therefore, the objective of this study was to evaluate the accuracy of the rotational alignment of the femoral component positioned with the superimposed template in TKA.

Patients and methods

Twenty-six consecutive TKA patients, including 4 females with bilateral TKAs were enrolled.

To prepare a template, all knees received CT scans with a 2.5 mm slice thickness preoperatively. Serial three slices of the CT images, in which the medial epicondyle and/or lateral epicondyle were visible, were selected. Then, these images were merged into a single image onto which the SEA was drawn. Thereafter, another serial two CT images, which were taken at approximately 9 mm proximal from the femoral condyles, were also selected, and the earlier drawn SEA was traced onto each of these pictures. These pictures with the SEA were then printed out onto transparent sheets to be used as potential “templates” (Fig. 1-a).

In the TKA, the distal femur was resected with the modified measured resection technique. Then, one template, whichever of the two potential templates, was closer to the actual shape, was selected and its SEA was duplicated onto the distal femoral surface (Fig. 1-b). Following that, the distal femur was resected parallel to this SEA.

The rotational alignment of the femoral component was evaluated with CT scan postoperatively. For convention, an external rotation of the femoral component from the SEA was given a positive numerical value, and an internal rotation was given a negative numerical value.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 42 - 42
1 Feb 2017
Kamenaga T Yamaura K Kataoka K Yahiro S Kanda Y Oshima T Matsumoto T Maruo A Miya H Muratsu H Kuroda R
Full Access

Objective

As the aging society progresses rapidly in Japan, the number of elderly patients underwent TKA is increasing. These elderly patients do not expect to do sports, but regain independency in the activity of daily living. Therefore, we measured basic ambulatory function quantitatively using 3m timed up and go (TUG) test. We clinically experienced patient with medially unstable knee after TKA was more likely to result in the unsatisfactory outcome. We hypothesized that post-operative knee stability influenced ambulatory function recovery after TKA. In this study, we evaluated ambulatory function and knee stability quantitatively, and analyzed the effect of knee stability on the ambulatory function recovery after TKA.

Materials & Methods

Seventy nine patients with varus type osteoarthritic knees underwent TKA were subjected to this study. The mean age of surgery was 72.4 years old. Preoperative standing coronal deformity was 9.6 degrees in varus. TUG test results in less duration with faster ambulatory function. TUG (seconds) was measured at 3 time periods; pre-operatively, at hospital discharge and 1year after surgery. To standardize TUG recovery time during 1 year after TKA, we defined TUG recovery rate as the percentage of recovery time to the pre-operative TUG as shown in the following equation. TUG recovery rate (%) = (TUG pre-op –TUG 1y po) / TUG pre-op ×100

We also evaluated the knee stability at hospital discharge and 1year after surgery. The knee stability at extension and flexion were assessed by varus and valgus stress radiography using Telos (10kg) and stress epicondylar view with 1.5kg weight at the ankle respectively. Image analyzing software was used to measure joint separation distance (mm) at medial as medial joint opening (MJO) and at lateral as lateral joint opening (LJO) at both knee extension and flexion. (Fig.1)

The sequential change of TUG was analyzed using repeated measures ANOVA (p<0.05). The influence of joint opening distances (MJO and LJO at extension and flexion) on TUG 1y po and TUG recovery rate were analyzed using simple linear regression analysis (p<0.05).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 134 - 134
1 Feb 2017
Majima T Matsui S Nishiike O Takahashi K Oshima Y Iizawa N Takai S
Full Access

Introduction

In order to achieve good clinical results in TKA, soft tissue balance is important. Soft tissue balance is closely related to knee kinematics which affects clinical results.

Modified gap balancing technique is one of the standard techniques for posterior stabilized (PS) TKA. On the other hand, appropriate load for the measurement of gap balance has not been established.

The purpose of the present study is to measure the mechanical properties of soft tissue structure of knee sleeve in flexion and extension during PS TKA using newly developed balancer. The understanding of the mechanical properties is crucial. In particular if these properties are used as input for surgical procedures, standard technique for many surgeons will be established.

Materials and Methods

Medial compartmental osteoarthrosis (OA) patients (13 female and 7 male) were evaluated. Average age, BMI, and Varus deformity were 72.1 years, 26.9, and 12 degrees, respectively.

The newly developed center paddle balancer consists of a built-in spring (Fig. 1). Figure 2 shows the sequence of surgery and measurements. In the surgery, we measured the balance (degrees in Figure 1, A) and distance (mm in Figure 1, B) in extension with a load (Figure 1,C) at transition zone of toe region to linear region. Then, applying the load until flexion gap was the same as that in extension with a patella reduction, we measured the femoral component rotation from the balancer (degrees in Figure 1, A). The anterior and posterior femoral cuts were performed according to measured femoral component rotation which angle is parallel to tibial cut surface.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 24 - 24
1 Feb 2017
Iizawa N Oshima Y Kataoka T Matsui S Takai S
Full Access

Introduction

For restoration of neutral limb alignment in Total Knee Arthroplasty (TKA), we usually start by removing osteophytes in varus osteoarthritic knees. However, we have found no reports in the literature regarding research on the exact influence of osteophyte removal on angle correction. The purpose of this study was to define the influence of osteophyte removal on limb alignment correction in the coronal plane in TKA.

Materials and Methods

Nine patients with varus malalignment that were scheduled for TKA were included in this study. Only patients with degenerative osteoarthritis were considered. After registration of a navigation system, each knee was tested at maximum extension, and 30 and 60 degrees of flexion before and after osteophyte removal. The same examiner applied all external loads of 10 N-m valgus torque at each angle and in both states. Subsequently, the widths of the osteophytes were measured. All data were analyzed statistically using paired t-test and correlation coefficient. A significant difference was determined to be present for P < .05.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 44 - 44
1 Feb 2017
Kanda Y Kudo K Kamenaga T Yahiro S Kataoka K Oshima T Matsumoto T Maruo A Miya H Muratsu H Kuroda R
Full Access

Introduction

Although gap balancing technique has been reported to be beneficial for the intra-operative soft tissue balancing in posterior-stabilized (PS)-TKA, excessive release of medial structures for achieving perfect ligament balance would be more likely to result in medial instability, which would deteriorate post-operative clinical results. We have modified conventional gap balancing technique and devised a new surgical concept; named as “medial gap technique” aiming at medial stability with permitting lateral looseness, as physiologically observed in normal knee.

Objective

We compared intra-operative soft tissue balance between medial gap technique (MGT) and measured resection technique (MRT) in PS-TKAs.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 105 - 105
1 May 2016
Oshima Y Takai S Fetto J
Full Access

Background

Total knee arthroplasty (TKA) is the highly developed procedure for sever osteoarthritic knee, in which there are two major concepts; Cruciate Retaining design (CR) and Posterior Stabilized design (PS). The femoral roll back movement is enforced with the post-cam mechanism in the PS, however, this structure associates with the complications, i.e. wear and dislocation. The CR has been developed to obtain the knee stability with native posterior cruciate ligament (PCL) in TKA. However, the preservation of the PCL can limit knee exposure and increase the technical challenge of surgery. We hypothesized that the knee exposure was easily achieved after the PCL was released, however, the PCL was repaired and the posterior stability was re-established after the TKA with time if it was released subperiostealy.

Objective

The objective of this study was to evaluate the varying of the posterior stability after the PCL-released CR TKA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 87 - 87
1 May 2016
Kataoka T Iizawa N Mori A Oshima Y Matsui S Takai S
Full Access

Introduction

Many factors can influence post-operative kinematics after total knee arthroplasty (TKA). These factors include intraoperative surgical conditions such as ligament release or quantity of bone resection as well as differences in implant design. Release of the medial collateral ligament (MCL) is commonly performed to allow correction of varus knee. Precise biomechanical knowledge of the individual components of the MCL is critical for proper MCL release during TKA. The purpose of this study was to define the influences of the deep medial collateral ligament (dMCL) and the posterior oblique ligament (POL) on valgus and rotatory stability in TKA.

Materials and Methods

This study used six fresh-frozen cadaveric knees with intact cruciate ligaments. All TKA procedures were performed by the same surgeon using CR-TKA with a CT-free navigation system. Each knee was tested at 0°, 20°, 30°, 60°, and 90° of flexion. One sequential sectioning sequence was performed on each knee, beginning with an intact knee (S0), and thereafter femoral arthroplasty only (S1), tibial arthroplasty (S2), release of the dMCL (S3), and finally, release of the POL (S4). The same examiner applied all external load of 10 N-m valgus and a 5 N-m internal and external rotation torque at each flexion angle for the each cutting state. All data were analyzed statistically using one-way ANOVA and we investigated the correlation between the medial gap and the rotation angle. A significant difference was determined to be present for P < .05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 132 - 132
1 May 2016
Fetto J Oshima Y
Full Access

This is a minimum 15 year follow up of a cohort of 58 patients (30 men and 28 women) who underwent 62 non-cemented THR between 1998–2000 (54 unilateral, 4 bilateral), in whom an off-the-shelf “lateral flare” femoral component was implanted. These surgeries were performed by a single surgeon and have been followed continuously by that same surgeon. The mean age at the time of surgery was 60.4 yrs (52–74). There were no exclusions for osteoporosis or type “C” femoral geometry. Although some patients have deceased during these 15 years, there have been no stem failures, revisions or impending stem revisions at the time of follow up or at the time of death in those who have passed. Two patients have undergone revision of their acetabular liner for poly wear. There have been no complaints of thigh pain; and like the results seen in other series employing this stem design, there has been no evidence of bone loss due to stress shielding or subsidence of the femoral component in any of these patients.

This mid-term follow up re-affirms the dynamic tension band model of hip biomechanics, upon which the “lateral flare” design is predicated. This model predicts that the proximal lateral femur can experience compression during the gait cycle and as such can be utilized as an additional base of support upon which the femoral component can rest. Rather than relying upon a traditional “press fit” technique to achieve initial implant stability, a technique which is highly dependent upon femoral geometry, bone quality and may risk fracture on implant seating, the “lateral flare” design permits a gentler, safer and more physiologic means of achieving initial implant stability necessary for osseous integration to occur. This alterantive terchnique has been termed a “rest fit”.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 138 - 138
1 May 2016
Yamaura K Muratsu H Tsubosaka M Annziki K Kudo K Minamino S Oshima T Matsumoto T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Introduction

As the aging society progresses rapidly, the number of patients underwent total knee arthroplasty (TKA) is increasing especially for the elderly population. In Japan, the average age for TKA is around 75 years old. Japanese Orthopaedic Association indicated a new clinical entity of musculoskeletal ambulation disability symptom complex (MADS) to define the higher risk of fall and ambulatory disability in the elderly population in 2006. The diagnosing criteria for MADS consists of 2 simple performance tests. 3m timed up and go test (TUG) evaluates ambulatory function, and one leg standing time (ST) assesses balancing ability.

Objective

In this study, we analyzed the effect of TKA on the ambulatory function by quantitative measurement using 2 simple performances test: TUG and ST.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 68 - 68
1 May 2016
Muratsu H Takemori T Matsumoto T Annziki K Kudo K Yamaura K Minamino S Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Introduction

To achieve well aligned and balanced knee is essential for the post-operative outcome in total knee arthroplasty (TKA). Gap balancing technique can adjust the bone cut depending on the soft tissue balance in addition to soft tissue releases. Therefore, gap balancing technique would be more advantageous in soft tissue balance comparing to measured resection technique (MRT) in which soft tissue balancing relayed on soft tissue releases alone. Nevertheless, the influence of surgical technique on the post-operative knee stability has not been fully investigated.

Objective

We introduced a new surgical technique (medial gap technique: MGT) according to modified gap technique regarding medial knee stability as important. The intra-operative soft tissue balance and post-operative knee stability were compared between MGT and MRT in posterior-stabilized (PS) TKA for varus type osteoarthritic knees.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 47 - 47
1 May 2016
Iizawa N Mori A Oshima Y Matsui S Kataoka T Takai S
Full Access

Introduction

Many factors can influence post-operative kinematics after total knee arthroplasty (TKA). These factors include intraoperative surgical conditions such as ligament release or quantity of bone resection as well as differences in implant design. Release of the medial collateral ligament (MCL) is commonly performed to allow correction of varus knee. Precise biomechanical knowledge of the individual components of the MCL is critical for proper MCL release during TKA. The purpose of this study was to define the influences of the deep medial collateral ligament (dMCL) and the posterior oblique ligament (POL) on kinematics in TKA.

Materials and Methods

This study used six fresh-frozen cadaveric knees with intact cruciate ligaments. All TKA procedures were performed by the same surgeon using CR-TKA with a CT-free navigation system. Each knee was tested at 0°, 20°, 30°, 60°, and 90° of flexion. One sequential sectioning sequence was performed on each knee, beginning with femoral arthroplasty only (S1), and thereafter sequentially; medial half tibial resection with spacer (S2), ACL cut (S3), tibial arthroplasty (S4), release of the dMCL (S5), and finally, release of the POL (S6). The same examiner applied all external loads of 10 N-m valgus and 5 N-m internal and external rotation torques at each flexion angle and for each cut state. The AP locations of medial and lateral condyles were determined as the lowest point on each femoral condyle. All data were analyzed statistically using paired t-test. A significant difference was determined to be present for P < .05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 50 - 50
1 Jan 2016
Takemori T Muratsu H Takeoka Y Matsumoto T Takashima Y Tsubosaka M Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Objective

The goal of total knee arthroplasty (TKA) is to achieve a stable and well-aligned tibiofemoral and patello-femoral (PF) joint, aiming at long-term clinical patient satisfaction. The surgical principles of both cruciate retaining (CR) and posterior stabilized (PS) TKA are accurate osteotomy and proper soft tissue balancing. We have developed an offset-type tensor, and measured intra-operative soft tissue balance under more physiological joint conditions with femoral component in place and reduced PF joint.

In this study, we measured intra-operative soft tissue balance and assessed the post-operative knee joint stability quantitatively at one month, six months and one year after surgery, and compared these parameters between CR and PS TKAs.

Material and Method

Sixty patients with varus osteoarthritis of the knee underwent TKAs (30 CR TKAs: CR and 30 PS TKAs: PS). Mean varus deformity in standing position was 11.1 degrees in CR, and 12.6 degrees in PS. All TKAs were performed by a single surgeon with measured resection technique. The external rotation of posterior femoral condyle osteotomy was performed according to surgical epicondylar axis in pre-operative CT. We measured intra-operative soft tissue balance using an offset-type tensor with 40 lbs of joint distraction force at 0, 10, 30, 45, 60, 90, 120 and 135 degrees of flexion. The joint component gap (mm) and varus angle (degrees) were measured at each flexion angles.

One month, six months and one year after surgery, we evaluated the knee stability at extension by varus and valgus stress radiography using Telos (10kg) and at flexion by epicondylar view with 1.5kg weight at the ankle. We measured joint separation distance at medial as medial joint looseness (MJL) and at lateral as lateral joint looseness (LJL). Intra-operative measurements and post-operative joint stabilities were compared between CR and PS using unpaired t-test. The change of joint looseness in each group was analyzed using repeated measures ANOVA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 111 - 111
1 Jan 2016
Oshima Y Fetto J
Full Access

Introduction

Pulmonary emboli (PE) after total hip and knee arthroplasties is an uncommon event. However, once it happens, it may results in sudden death. Thus, the prophylaxis of venous thromboembolism (VTE), including symptomatic deep vein thrombosis (DVT) and PE, is one of the challenging trials for Orthopaedic surgeons. Many procedures have been developed, e.g. early mobilization, compression stocking, intermittent pneumatic compression (IPC) devices, and anticoagulation agents. However, the most effective treatment for prophylaxis against VTE after the arthroplasties remains undecided.

Recently, many low molecular weight heparin (LMWH) agents are developing, and these are strongly effective for anticoagulation. However, these agents sometimes lead to bleeding complications, and result in uncontrolled critical bleeding. We are introducing our protocol with conventional aspirin as VTE prophylaxis after the arithroplasties.

Patients and methods

All patients prior to the surgeries are evaluated laboratory and duplex venous ultrasonography examinations to exclude thrombophilic or hemophilic conditions, and existence of DVT. Then, the thrombophilic, and also prolonged immobility, obesity, malignant tumors, cardiovascular dysfunction and DVT patients are regarded as high risk for VTE. These are offered a prophylaxis consisting of a removable inferior vena cava (IVC) filter, together with anticoagulant medication. Usually, the filter is removed three months after the surgery. In other patients, the arthroplasties are carried out under the spinal or epidural anesthesia with IPC on both feet. IPC is also applied, except for the periods of ambulation, usually two to three days of hospitalization after surgery. Full weight bearing ambulation with a walker is allowed on post-op day one.

Patients receive aspirin (acetylsalicylic acid) 325 mg daily for six weeks starting the night of surgery. Pain is controlled with celecoxib (COX-2 selective nonsteroidal anti-inflammatory drug) 400 mg daily, and oral narcotics for break through pain. Before discharge, usually within three days post surgery, all patients are evaluated DVT by duplex venous ultrasonography. The incidence of blood loss, wound complications, and subcutaneous ecchymosis are recorded.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 65 - 65
1 Jan 2016
Muratsu H Takemori T Nagai K Matsumoto T Takashima Y Tsubosaka M Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Introduction

Appropriate osteotomy alignment and soft tissue balance are essential for the success of total knee arthroplasty (TKA). The management of soft tissue balance still remains difficult and it is left much to the surgeon's subjective feel and experience.

We developed an offset type tensor system for TKA. This device enables objective soft tissue balance measurement with more physiological joint conditions with femoral trial component in place and patello-femoral (PF) joint reduced. We have reported femoral component placement decreased extension gap.

The purpose of the present study was to analyze the influence of femoral component size selection on the decrease of extension gap in posterior-stabilized (PS) TKA.

Material & Method

120 varus type osteoarthritic knees implanted with PS TKAs (NexGen LPS flex: Zimmer) were subjected to this study. All TKAs were performed using measured resection technique with anterior reference.

The femoral component size was evaluated intra-operatively using conventional femoral sizing jig. The selected femoral component size was expressed by the antero-posterior (AP) size increase (mm) comparing to that of original femoral condyles. Gap measurements were performed using a newly developed offset type tensor device applying 40lbs (178N) of joint distraction force. Firstly, conventional osteotomy gaps (mm) were measured at extension and flexion. Secondary, component gaps (mm) after femoral trial placement with PF joint reduced were evaluated at 0° and 90° of knee flexion.

To compare conventional osteotomy gaps and component gaps, estimated extension and flexion gaps were calculated by subtracting the femoral component thickness at extension (9mm) and flexion (11mm) from conventional osteotomy gaps respectively. The decrease of gap at extension and flexion were calculated with estimated gaps subtracted by component gaps. The simple linear regression analysis was used to evaluate the influence of selected femoral component size on the decrease of gap after femoral component placement.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 110 - 110
1 Jan 2016
Oshima Y Fetto J
Full Access

Introduction

Femoral neck fracture is a common injury in elderly patients. To restore the activity with an acceptable morbidity and to decrease of mortality, surgical procedures are thought to be superior to conservative treatments. Osteosynthesis with internal fixation for nondisplaced type, and hemiarthroplasty or total hip replacement (hip arthroplasties) for displaced type are commonly performed.

Cemented arthroplasty has been preferred over non-cemented arthroplasty because of less postoperative pain, better mobility and excellent initial fixation of the implant, especially for osteoporotic and stove-pipe bones. However, pressurizing bone cement may cause cardiorespiratory and vascular complications, and occasionally death, which has been termed as “bone cement implantation syndrome”. To avoid the occurrence of this syndrome, non-cemented implants have been developed. However, most implants with the press fit concepts and flat wedge taper designs have a risk of intraoperative and early postoperative periprosthetic fracture.

Recently, we have employed a non-cemented femoral component, which has a lateral expansion to the proximal body as compared to a conventional hip stem. Because of this shape, which is called a “lateral flare”, this stem provides a physiological loading on both the medial and lateral endosteal surfaces of the femur. This is in contrast to conventional hip stem which prioritizes loading on the medial and metaphyseal /dyaphyseal surfaces of the femur. Moreover, the cross section of this stem is trapezoid with the flat posterior surface. This shape provides the stem with rotational stability along the long axis of the femur, and maximizes loading transfer to the posterior aspect of the proximal femur. These mechanical features avoid the need for aggressive impaction of the stem at the time of insertion. It is necessary to only tap gently to achieve the secure initial implant fixation by a “rest fit”. Thus, this technique reduces the risk of fracture.

Patients and methods

We employed this technique using a non-cemented lateral flare design device for displaced femoral neck fractures since 1996. Surgical procedures were performed with posterior approach under the spinal or epidural anesthesia. Full weight bearing ambulation with a walker was allowed on post-op day one.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 180 - 180
1 Dec 2013
Takeoka Y Muratsu H Kihara S Matsumoto T Miyaji N Oshima T Maruo A Miya H Kuroda R Kurosaka M
Full Access

Objective

The goal of total knee arthroplasty (TKA) is to achieve a stable and well-aligned tibiofemoral and patello-femoral (PF) joint, aiming at long-term clinical patient satisfaction. The surgical principles of both cruciate retaining (CR) and posterior stabilized (PS) TKA are accurate osteotomy and proper soft tissue balancing. We have developed an offset-type tensor, and measured intra-operative soft tissue balance under more physiological joint conditions with femoral component in place and reduced PF joint.

In this study, we measured intra-operative soft tissue balance and assessed the early post-operative knee joint stability quantitatively, and compared these parameters between CR and PS TKA.

Material and Method

Seventy patients with varus osteoarthritis of the knee underwent TKAs (35 CR TKAs: CR and 35 PS TKAs: PS). Mean varus deformity in standing position was 9.8 degrees in CR, and 10.7 degrees in PS (p = 0.45). All TKAs were performed by a single surgeon with measured resection technique. The external rotation of posterior femoral condyle osteotomy was performed according to surgical epicondylar axis (SEA) in pre-operative CT. We measured intra-operative soft tissue balance using an offset-type tensor with 40 lbs of joint distraction force at 0, 10, 30, 45, 60, 90, 120 and 135 degrees of flexion. The joint component gap (mm) and varus angle (degrees) were measured at each flexion angle.

Four weeks after operation, we evaluated the knee stability at extension by varus and valgus stress radiography using Telos (10 kg) and at flexion by epicondylar view with 1.5 kg weight at the ankle. We measured joint separation distance at medial as medial joint looseness (MJL) and at lateral as lateral joint looseness (LJL). Joint looseness was defined as the average of MJL and LJL.

Intra-operative measurements and post-operative joint stabilities were compared between CR and PS using unpaired t-test.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 6 - 6
1 Apr 2013
Sakagoshi D Sawaguchi T Shima Y Inoue D Oshima T Goldhahn S
Full Access

Introduction

Tip apex distance (TAD) is reported as a predictor for cut outs of lag screws in the treatment of intertrochanteric fractures, and surgeons are adviced to strive for TAD within 20 mm. However the definition of neck axis and the limb position of lateral radiograph are not clearly described in the original literature. We propose the refined TAD by defining these factors. The objective of this study was to analyze the interobserver agreement of this refined TAD.

Materials and Method

X rays of 130 cases of unstable trochanteric fractures were used for the analysis of the refined TAD. In the refined TAD, neck axis was defined as the line between the center of femoral head and midpoint of narrowest part of the femoral neck, and lateral radiograph was taken with hip flexion 90 degrees and abduction 45 degrees. The refined TAD was independently measured by 2 experienced (observer 1,2) and 2 inexperienced (observer 3,4) orthopaedic surgeons who were trained with the new method before the measurement. Intraclass correlation coefficient (ICC [2,4]) was calculated to assess the interobserver agreement.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 22 - 22
1 Mar 2012
Yamasaki T Yasunaga Y Hamaki T Yoshida T Oshima S Hori J Yamasaki K Ochi M
Full Access

Introduction

Since 2005, we have performed implantation of bone marrow-derived mononuclear cells for osteonecrosis of the femoral head in order to improve vascularization and bone repair. This study focused on early bone repair of osteonecrosis of the femoral head after transplantation of bone marrow-derived mononuclear cells (BMMNC).

Patients and Methods

Twenty-two patients (30 joints) who had bilateral osteonecrosis followed for more than 2 years after BMMNC implantation were evaluated. Eight women and 14 men were included. Their mean age at surgery was 41 years (range, 18 to 64 years) and the mean follow-up period was 31 months. Pre-operative stage according to the ARCO classification was Stage 2 in 25 joints and Stage 3 in 5 joints. The mean volume ratio of osteonecrosis was 21%. For preparing BMMNC, about 700ml of bone marrow was aspirated from the ilium and centrifuged using a Spectra cell separator (Gambro). The BMMNC were seeded to interconnected porous calcium hydroxyapatite (IP-CHA) and implanted to the osteonecrotic lesion. As a control, cell-free IP-CHA was implanted for 8 patients (9 joints). A woman and 7 men were included. The mean age at surgery was 49 years (range, 28 to 73 years) and the mean follow-up period was 37 months. Preoperative stage was stage 2 in all patients. The mean volume ratio of osteonecrosis was 22%. At post-operative evaluations; progression of collapse, consolidation at reactive zone, post-operative course of volume rate of osteonecrosis, and bone absorption at osteonecrosis was assessed.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 149 - 150
1 May 2011
Yasunaga Y Yamasaki T Hamaki T Yoshida T Oshima S Hori J Yamasaki K Ochi M
Full Access

Background: A retroverted acetabulum has been hypothesized as a cause of osteoarthritis. This study was performed to evaluate whether radiographical cross-over sign influence the painful femoro-acetabular impingement or the radiographical progression of osteoarhritis after rotational acetabular osteotomy (RAO) for dysplastic hip.

Methods: Between 1987 and 1999, 104 patients (115 hips) who had pre- or early stage osteoarthritis of the hip due to dysplasia underwent a RAO. There were 99 women and five men; their mean age at the time of surgery was 34.7 years. The mean follow-up period was 13 years. Clinical follow-up was performed with use of the system of Merle d’Aubigne and the impingement sign was evaluated. Radiographical analyses included measurements of the center-edge angle, acetabular roof angle, head lateralization index, joint congruency, cross-over sign, posterior wall sign, acetabular index of depth to width, pistol grip deformity and femoral head-femoral neck ratio.

Results: The mean clinical score improved significantly from 14.6 preoperatively to 17.0 at follow-up. The impingement sign at the follow-up was observed in 14 hips (12.2%). The center-edge angle improved significantly from mean −0.6 degrees to a postoperative mean of 34 degrees. The acetabular roof angle improved from 30 degrees to 2.2 degrees, and head lateralization index from 0.64 to 0.60. The cross-over sign was observed in 8 hips (7.0%) preoperatively and in 49 hips (42.6%) postoperatively. The posterior wall sign was observed in 70 hips (60.9%) preoperatively and observed in 73 hips (63.5%) postoperatively. The mean preoperative acetabular index of depth to width was 35.5% and the mean preoperative femoral head to femoral neck ratio was 1.49. The pistol grip deformity was observed in only 4 hips (3.5%) preoperatively. The impingement sign after the RAO was positive significantly in the postoperative cross-over sign positive hips (p=0.0074). Radiographical progression of osteoarthritis was observed in 11 hips (cross over sign positive; 7 hips, cross over sign negative; 4 hips). The Kaplan-Meier survivorship analysis predicted a survival rate of 84.6 % at 15 years. The only factors significantly associated with radiographic signs of progression of osteoarthritis after RAO were fair (rather than excellent and good) postoperative joint congruency (p< 0.0001) and age at surgery (p=0.0042). Presence of postoperative cross-over sign had no effect on the outcome (p=0.2073).

Conclusions: Although there was no significant radiographical progression of osteoarthritis despite a significant retroversion in most cases, the goal of RAO should be a correct alignment of the acetabulum including a correct version with a negative cross-over sign.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1606 - 1613
1 Nov 2010
Oshima S Ishikawa M Mochizuki Y Kobayashi T Yasunaga Y Ochi M

We used interconnected porous calcium hydroxyapatite ceramic to bridge a rabbit ulnar defect. Two weeks after inducing the defect we percutaneously injected rabbit bone marrow-derived mesenchymal stromal cells labelled with ferumoxide. The contribution of an external magnetic targeting system to attract these cells into the ceramic and their effect on subsequent bone formation were evaluated.

This technique significantly facilitated the infiltration of ferumoxide-labelled cells into ceramic and significantly contributed to the enhancement of bone formation even in the chronic phase. As such, it is potentially of clinical use to treat fractures, bone defects, delayed union and nonunion.