header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

INFLUENCE OF POSTERIOR TIBIAL SLOPE ON ONE-YEAR POSTOPERATIVE PATIENT SATISFACTION AFTER POSTERIOR-STABILIZED TOTAL KNEE ARTHROPLASTY

International Society for Technology in Arthroplasty (ISTA) 31st Annual Congress, London, England, October 2018. Part 2.



Abstract

Background

The posterior slope of the tibial component in total knee arthroplasty (TKA) has been reported to vary widely even with computer assisted surgery. In the present study, we analyzed the influence of posterior tibial slope on one-year postoperative clinical outcome after posterior-stabilized (PS) -TKA to find out the optimal posterior slope of tibial component.

Materials and Method

Seventy-three patients with varus type osteoarthritic (OA) knees underwent PS-TKA (Persona PSR) were involved in this study. The mean age was 76.6 years old and preoperative HKA angle was 14.3 degrees in varus. Tibial bone cut was performed using standard extra-medullary guide with 7 degrees of posterior slope.

The tibial slopes were radiographically measured by post-operative lateral radiograph with posterior inclination in plus value. The angle between the perpendicular line of the proximal fibular shaft axis and the line drawn along the superior margin of the proximal tibia represented the tibial slope angle. We assessed one-year postoperative clinical outcomes including active range of motion (ROM), patient satisfaction and symptoms scores using 2011 Knee Society Score (2011 KSS).

The influences of posterior tibial slope on one-year postoperative parameters were analyzed using simple linear regression analysis (p<0.05).

Results

The average posterior tibial slope was 6.4 ± 2.0 °. The average active ROM were −2.4 ± 6.6 ° in extension and 113.5± 12.6 ° in flexion. The mean one-year postoperative patient satisfaction and symptom scores were 29.3 ± 6.4 and 19.6 ± 3.9 points respectively. The active knee extension, satisfaction and symptom scores were significantly negatively correlated to the posterior tibial slope (r = −0.25, −0.31, −0.23).

Discussion

In the present study, we have found significant influence of the posterior tibial slope on the one-year postoperative clinical outcomes in PS-TKA. The higher posterior slope would induce flexion contracture and deteriorate patient satisfaction and symptom.

We had reported that the higher tibial posterior slope increased flexion gap and the component gap change during knee flexion in PS-TKA. Furthermore, another study reported that increase of the posterior tibia slope reduced the tension in the collateral ligaments and resulted in the knee laxity at flexion. The excessive posterior slope of tibial component would result in flexion instability, and adversely affected the clinical results including patient satisfaction and symptom.

Conclusion

In the PS-TKA for varus type OA knees, excessive tibial posterior slope was found to adversely affect one-year postoperative knee extension and clinical outcome including patient satisfaction and symptom. Surgeons should aware of the importance of tibial slope on one-year postoperative clinical results and pay more attentions to the posterior tibial slope angle not to be excessive.