header advert
Results 1 - 50 of 76
Results per page:
Bone & Joint Open
Vol. 5, Issue 5 | Pages 444 - 451
24 May 2024
Gallagher N Cassidy R Karayiannis P Scott CEH Beverland D

Aims

The overall aim of this study was to determine the impact of deprivation with regard to quality of life, demographics, joint-specific function, attendances for unscheduled care, opioid and antidepressant use, having surgery elsewhere, and waiting times for surgery on patients awaiting total hip arthroplasty (THA) and total knee arthroplasty (TKA).

Methods

Postal surveys were sent to 1,001 patients on the waiting list for THA or TKA in a single Northern Ireland NHS Trust, which consisted of the EuroQol five-dimension five-level questionnaire (EQ-5D-5L), visual analogue scores (EQ-VAS), and Oxford Hip and Knee Scores. Electronic records determined prescriptions since addition to the waiting list and out-of-hour GP and emergency department attendances. Deprivation quintiles were determined by the Northern Ireland Multiple Deprivation Measure 2017 using postcodes of home addresses.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 35 - 35
2 May 2024
Robinson M Wong ML Cassidy R Bryce L Lamb J Diamond O Beverland D
Full Access

The significance of periprosthetic fractures about a total hip arthroplasty (THA) is becoming increasingly important. Recent studies have demonstrated post-operative periprosthetic fracture rates are higher amongst cemented polished taper slip (PTS) stem designs compared to collared cementless (CC) designs.

However, in the National Joint Registry, the rate of intra-operative periprosthetic femoral fractures (IOPFF) with cementless implant systems remains higher (0.87% vs 0.42%. p <0.001) potentially leading to more post-operative complications.

This study identifies the incidence of IOPFF, the fracture subtype and compares functional outcomes and revision rates of CC femoral implants with an IOPFF to CC stems and PTS stems without a fracture.

5376 consecutive CC stem THA, carried out through a posterior approach were reviewed for IOPFF. Each fracture was subdivided into calcar fracture, greater trochanter (GT) fracture or shaft fracture.

1:1:1 matched analysis was carried out to compare Oxford scores at one year. Matching criteria included; sex (exact), age (± 1 year), American Society of Anaesthesiologists (ASA) grade (exact), and date of surgery (± 6 months).

Electronic records were used to review revision rates.

Following review of the CC stems, 44 (0.8%) were identified as having an IOPFF. Of these 30 (0.6%) were calcar fractures, 11 (0.2%) GT fractures and 3 (0.06%) were shaft fractures. There were no shaft penetrations.

Overall, no significant difference in Oxford scores at one year were observed when comparing the CC IOPFF, CC non-IOPFF and PTS groups.

There were no CC stems revised for any reason with either a calcar fracture or trochanteric fracture within the period of 8 years follow-up.

IOPFF do occur more frequently in cementless systems than cemented. The majority are calcar and GT fractures. These fractures, when identified and managed intra-operatively, do not have worse functional outcomes or revision rates compared to matched non-IOPFF cases.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 144 - 150
1 Feb 2024
Lynch Wong M Robinson M Bryce L Cassidy R Lamb JN Diamond O Beverland D

Aims

The aim of this study was to determine both the incidence of, and the reoperation rate for, postoperative periprosthetic femoral fracture (POPFF) after total hip arthroplasty (THA) with either a collared cementless (CC) femoral component or a cemented polished taper-slip (PTS) femoral component.

Methods

We performed a retrospective review of a consecutive series of 11,018 THAs over a ten-year period. All POPFFs were identified using regional radiograph archiving and electronic care systems.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 783 - 794
1 Jul 2023
Karayiannis PN Warnock M Cassidy R Jones K Scott CEH Beverland D

Aims

The aim of this study was to report health-related quality of life (HRQoL) and joint-specific function in patients waiting for total hip or knee arthroplasty surgery (THA or TKA) in Northern Ireland, compared to published literature and a matched normal population. Secondary aims were to report emergency department (ED) and out-of-hours general practitioner (OOH GP) visits, new prescriptions of strong opioids, and new prescriptions of antidepressants while waiting.

Methods

This was a cohort study of 991 patients on the waiting list for arthroplasty in a single Northern Ireland NHS trust: 497 on the waiting list for ≤ three months; and 494 waiting ≥ three years. Postal surveys included the EuroQol five-dimension five-level questionnaire (EQ-5D-5L), visual analogue scores (EQ-VAS), and Oxford Hip and Knee scores to assess HRQoL and joint-specific function. Electronic records determined prescriptions since addition to the waiting list and patient attendances at OOH GP/EDs.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 34 - 34
1 Dec 2022
Sheridan G Garbuz D MacDonell T Neufeld M Howard L Beverland D Masri B
Full Access

The benefit of using acetabular screws in primary total hip arthroplasty (THA) has been questioned in recent years. The disadvantages of using screws include increased operative time, risk of injury to surrounding neurovascular structures and metal ware breakage. Recent large registry studies have reported that screws do not confer a protective effect against acetabular loosening or the presence of osteolysis. Other studies have even described an increased risk of aseptic acetabular loosening with the selective use of screws. We report findings from a multicentre cohort study.

This large cohort study compared clinical outcomes between primary acetabular components that were inserted with and without screws. Independent variables included the presence (or absence) of screws, the total number of screws used and the cumulative screw length (CSL). Outcome measures included all-cause revision, acetabular component revision and acetabular component loosening. Statistical software (Stata/IC 13.1 for Mac [64-bit Intel]) was used to conduct all statistical analyses. A p-value < 0 .05 taken to be significant.

There were 4,583 THAs performed in total. Screws were used in 15.9% (n=733). At a mean follow-up of 5.2 years, the all-cause revision rate in the screw cohort was 1.5% compared to 0.83% in the no screw cohort (p=0.085). There was no difference in acetabular component revision rates for screws (3/733, 0.41%) versus no screws (12/3,850, 0.31%) (p=0.439). The rate of acetabular loosening noted during the time of revision surgery was significantly higher when screws were used in the index procedure (2/733, 0.2%) compared to the no screw cohort (1/3,850, 0.02%) (p=0.017). There was no difference in outcomes when stratifying by the number of screws used or the cumulative screw length.

Primary acetabular components do not require screws for fixation. All cause revision rates and acetabular component revision rates are comparable for the screw and the no screw cohorts. The rate of acetabular component loosening, as observed during revision surgery, is significantly higher when screws are used in the index total hip replacement.


Bone & Joint Open
Vol. 3, Issue 7 | Pages 536 - 542
11 Jul 2022
Karayiannis PN Agus A Bryce L Hill JC Beverland D

Aims

Tranexamic acid (TXA) is now commonly used in major surgical operations including orthopaedics. The TRAC-24 randomized control trial (RCT) aimed to assess if an additional 24 hours of TXA postoperatively in primary total hip (THA) and total knee arthroplasty (TKA) reduced blood loss. Contrary to other orthopaedic studies to date, this trial included high-risk patients. This paper presents the results of a cost analysis undertaken alongside this RCT.

Methods

TRAC-24 was a prospective RCT on patients undergoing TKA and THA. Three groups were included: Group 1 received 1 g intravenous (IV) TXA perioperatively and an additional 24-hour postoperative oral regime, Group 2 received only the perioperative dose, and Group 3 did not receive TXA. Cost analysis was performed out to day 90.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 18 - 18
1 Jul 2022
Thompson R Cassidy R Hill J Bryce L Beverland D
Full Access

Abstract

Aims

The association between body mass index (BMI) and venous thromboembolism (VTE) is well studied, but remains unclear in the literature. We aimed to determine whether morbid obesity (BMI≥40) was associated with increased risk of VTE following total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA), compared to those of BMI<40.

Methods

Between January 2016 and December 2020, our institution performed 4506 TKAs and 449 UKAs. 450 (9.1%) patients had a BMI≥40. CT pulmonary angiography (CTPA) for suspected pulmonary embolism (PE) and ultrasound scan for suspected proximal deep vein thrombosis (DVT) were recorded up to 90 days post-operatively.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 65 - 65
1 Jul 2022
Brown W Gallagher N Bryce L Benson G Beverland D
Full Access

Abstract

Introduction

The Wells score is commonly used to assess the risk of proximal Deep Vein Thrombosis (DVT) following Knee Arthroplasty (KA). The National Institute for Health and Care Excellence (NICE) guidelines recommend an Ultrasound scan in patients with a Wells score of 2 points or more. We wanted to assess how often this protocol resulted in a scan being done and how many were negative.

Methodology

Details of all postoperative Ultrasound scans performed up to 90 days were audited in a high-volume unit between 1st January 2016 and 31st December 2020. This included all Lower Limb Arthroplasty patients


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 3 - 3
1 Jul 2022
Sheridan G Cassidy R McKee C Hughes I Hill J Beverland D
Full Access

Abstract

Introduction

With respect to survivorship following total knee arthroplasty (TKA), joint registries consistently demonstrate higher revision rates for both sexes in those less than 55 years. The current study analyses the survivorship of 500 cementless TKAs performed in this age group in a high-volume primary joint unit where cementless TKA has traditionally been used for the majority of patients.

Methods

This was a retrospective review of 500 consecutive TKAs performed in patients under the age of 55 between March 1994 and April 2017. The primary outcome measure for the study was all-cause revision. Secondary outcome measures included clinical, functional and radiological outcomes.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 1 - 1
1 Apr 2022
Karayiannis P Agus A Bryce L Hill J Beverland D
Full Access

Tranexamic Acid (TXA) is now commonly used in major surgical operations including orthopaedics. The TRAC-24 randomised control trial aimed to assess if an additional 24 hours of TXA post – operatively in primary total hip (THA) and total knee arthroplasty (TKA) reduced blood loss. Contrary to other orthopaedic studies to date this trial included high risk patients. This paper presents the results of a cost analysis undertaken alongside this RTC.

TRAC-24 was a prospective randomised controlled trial on patients undergoing TKA and THA. Three groups were included, Group 1 received 1 g intravenous (IV) TXA perioperatively and an additional 24-hour post-operative oral regime, group 2 received only the perioperative dose and group 3 did not receive TXA. Cost analysis was performed out to day 90.

Group 1 was associated with the lowest mean total costs, followed by group 2 and then group 3. The difference between groups 1 and 3 −£797.77 (95% CI −1478.22, −117.32) were statistically significant. Extended oral dosing reduced costs for patients undergoing THA but not TKA. The reduced costs in groups 1 and 2 resulted from reduced length of stay, readmission rates, Accident and Emergency (A&E) attendances and blood transfusions.

This study demonstrated significant cost savings when using TXA in primary THA or TKA. Extended oral dosing reduced costs further in THA but not TKA.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 966 - 973
17 Nov 2021
Milligan DJ Hill JC Agus A Bryce L Gallagher N Beverland D

Aims

The aim of this study is to assess the impact of a pilot enhanced recovery after surgery (ERAS) programme on length of stay (LOS) and post-discharge resource usage via service evaluation and cost analysis.

Methods

Between May and December 2019, 100 patients requiring hip or knee arthroplasty were enrolled with the intention that each would have a preadmission discharge plan, a preoperative education class with nominated helper, a day of surgery admission and mobilization, a day one discharge, and access to a 24/7 dedicated helpline. Each was matched with a patient under the pre-existing pathway from the previous year.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 7 - 7
1 Nov 2021
Morlock M Bätz J Beverland D Board T Lampe F Konow T
Full Access

The influence of the surgical process on implant loosening and periprosthetic fractures (PPF) as major complications in uncemented total hip arthroplasty (THA) have rarely been studied due to the difficult quantification. Meanwhile registry analyses have clearly shown a decrease in complications with increasing experience. The goal of this study was to determine the extent of variability in THA stem implantation between highly experienced surgeons with respect to implant-size, -position, press-fit, contact area, primary stability and the effect of using a powered impaction tool.

Primary hip stems were implanted in 16 cadaveric femur pairs by three experienced surgeons using manual and powered impaction. Quantitative CTs were taken before and after each process step and stem tilt, canal-fill-ratio, pressfit and contact area between bone and implant determined. 11 femur pairs were additionally tested for primary stability under cyclic loading conditions.

Higher variations in press-fit and contact area between the surgeons for manual impactions compared to powered were observed. Stem tilt and implant sizing varied between surgeons but not between impaction methods. Larger stems exhibited less micromotion compared to smaller stems.

Larger implants may increase PPF risk, while smaller implants reduce primary stability. The reduced variation for powered impactions indicates that appropriate measures may promote a more standardized process. The observed variations between the experienced surgeons may represent the acceptable range for this specific stem design. Variability in the implantation process warrants further investigations since certain deviations e.g. a stem tilt towards varus, might increase bone stresses and PPF risk.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1595 - 1603
1 Oct 2021
Magill P Hill JC Bryce L Martin U Dorman A Hogg R Campbell C Gardner E McFarland M Bell J Benson G Beverland D

Aims

In total knee arthroplasty (TKA), blood loss continues internally after surgery is complete. Typically, the total loss over 48 postoperative hours can be around 1,300 ml, with most occurring within the first 24 hours. We hypothesize that the full potential of tranexamic acid (TXA) to decrease TKA blood loss has not yet been harnessed because it is rarely used beyond the intraoperative period, and is usually withheld from ‘high-risk’ patients with a history of thromboembolic, cardiovascular, or cerebrovascular disease, a patient group who would benefit greatly from a reduced blood loss.

Methods

TRAC-24 was a prospective, phase IV, single-centre, open label, parallel group, randomized controlled trial on patients undergoing TKA, including those labelled as high-risk. The primary outcome was indirect calculated blood loss (IBL) at 48 hours. Group 1 received 1 g intravenous (IV) TXA at the time of surgery and an additional 24-hour postoperative oral regime of four 1 g doses, while Group 2 only received the intraoperative dose and Group 3 did not receive any TXA.


Bone & Joint Open
Vol. 2, Issue 7 | Pages 515 - 521
12 Jul 2021
Crookes PF Cassidy RS Machowicz A Hill JC McCaffrey J Turner G Beverland D

Aims

We studied the outcomes of hip and knee arthroplasties in a high-volume arthroplasty centre to determine if patients with morbid obesity (BMI ≥ 40 kg/m2) had unacceptably worse outcomes as compared to those with BMI < 40 kg/m2.

Methods

In a two-year period, 4,711 patients had either total hip arthroplasty (THA; n = 2,370), total knee arthroplasty (TKA; n = 2,109), or unicompartmental knee arthroplasty (UKA; n = 232). Of these patients, 392 (8.3%) had morbid obesity. We compared duration of operation, anaesthetic time, length of stay (LOS), LOS > three days, out of hours attendance, emergency department attendance, readmission to hospital, return to theatre, and venous thromboembolism up to 90 days. Readmission for wound infection was recorded to one year. Oxford scores were recorded preoperatively and at one year postoperatively.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1197 - 1205
1 Jul 2021
Magill P Hill JC Bryce L Martin U Dorman A Hogg R Campbell C Gardner E McFarland M Bell J Benson G Beverland D

Aims

A typical pattern of blood loss associated with total hip arthroplasty (THA) is 200 ml intraoperatively and 1.3 l in the first 48 postoperative hours. Tranexamic acid (TXA) is most commonly given as a single preoperative dose only and is often withheld from patients with a history of thromboembolic disease as they are perceived to be “high-risk” with respect to postoperative venous thromboembolism (VTE). The TRanexamic ACid for 24 hours trial (TRAC-24) aimed to identify if an additional 24-hour postoperative TXA regime could further reduce blood loss beyond a once-only dose at the time of surgery, without excluding these high-risk patients.

Methods

TRAC-24 was a prospective, phase IV, single centre, open label, parallel group, randomized controlled trial (RCT) involving patients undergoing primary unilateral elective THA. The primary outcome measure was the indirect calculated blood loss (IBL) at 48 hours. The patients were randomized into three groups. Group 1 received 1 g intravenous (IV) TXA at the time of surgery and an additional oral regime for 24 hours postoperatively, group 2 only received the intraoperative dose, and group 3 did not receive any TXA.


Bone & Joint Open
Vol. 2, Issue 4 | Pages 243 - 254
1 Apr 2021
Tucker A Warnock JM Cassidy R Napier RJ Beverland D

Aims

Up to one in five patients undergoing primary total hip (THA) and knee arthroplasty (TKA) require contralateral surgery. This is frequently performed as a staged procedure. This study aimed to determine if outcomes, as determined by the Oxford Hip Score (OHS) and Knee Score (OKS) differed following second-side surgery.

Methods

Over a five-year period all patients who underwent staged bilateral primary THA or TKA utilizing the same type of implants were studied. Eligible patients had both preoperative and one year Oxford scores and had their second procedure completed within a mean (2 SDs) of the primary surgery. Patient demographics, radiographs, and OHS and OKS were analyzed.


Bone & Joint Open
Vol. 1, Issue 8 | Pages 488 - 493
18 Aug 2020
Kang HW Bryce L Cassidy R Hill JC Diamond O Beverland D

Introduction

The enhanced recovery after surgery (ERAS) concept in arthroplasty surgery has led to a reduction in postoperative length of stay in recent years. Patients with prolonged length of stay (PLOS) add to the burden of a strained NHS. Our aim was to identify the main reasons.

Methods

A PLOS was arbitrarily defined as an inpatient hospital stay of four days or longer from admission date. A total of 2,000 consecutive arthroplasty patients between September 2017 and July 2018 were reviewed. Of these, 1,878 patients were included after exclusion criteria were applied. Notes for 524 PLOS patients were audited to determine predominant reasons for PLOS.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 11 - 11
1 Jul 2020
Magill P Hill J Bryce L Dorman A Hogg R Campbell C Benson G Beverland D
Full Access

Background

91% of blood loss in Total Hip Replacement (THR) occurs in the period after skin closure and the first 24 post-operative hours. TRAC-24 was established to identify if an additional 24-hour post-operative oral regime of Tranexamic acid (TXA) is superior to a once-only intravenous dose at surgery.

Methods

This was a prospective, phase IV, single centered, open label, parallel group controlled trial on patients undergoing primary elective THR. A history of thromboembolic or cardiovascular disease were not exclusion criteria. The primary outcome was indirect calculated blood loss at 48 hours (IBL). 534 patients were randomized on a 2:2:1 ratio over three different groups. Group 1 received an intravenous dose of TXA at the time of surgery and an additional 24-hour post-operative oral regime, Group 2 only received the intra-operative dose and Group 3 did not receive any TXA.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 22 - 22
1 Jul 2020
Mayne A Cassidy R Magill P Diamond O Beverland D
Full Access

Introduction

Previous research has demonstrated increased early complication rates following total hip arthroplasty in obese patients, as defined by body mass index (BMI). Subcutaneous fat depth has been shown to be an independent risk factor for wound infection in cervical and lumbar spine surgery as well as after abdominal laparotomy. The aim of this study was to investigate whether increased peri-trochanteric fat depth was associated with increased risk of early complication following total hip arthroplasty.

Methods

We analysed prospectively collected data on a consecutive series of 1220 patients undergoing primary total hip arthroplasty from June 2013 until May 2018. The vertical soft tissue depth from the most prominent part of the greater trochanter to the skin was measured using a sterile ruler and recorded to the nearest millimetre. BMI was calculated at the patient's pre-operative assessment review. All complications (infection, dislocation and peri-prosthetic fracture) occuring within the initial 12 month follow-up were identified.


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 938 - 944
1 Jul 2018
Karayiannis PN Hill JC Stevenson C Finnegan S Armstrong L Beverland D

Aims

The aims of this study were to determine the indications and frequency of ordering a CT pulmonary angiography (CTPA) following primary arthroplasty of the hip and knee, and to determine the number of positive scans in these patients, the location of emboli and the outcome for patients undergoing CTPA.

Patients and Methods

We analyzed the use of CTPA, as an inpatient and up to 90 days as an outpatient, in a cohort of patients and reviewed the medical records and imaging for each patient undergoing CTPA.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 19 - 19
1 May 2018
McMahon S Magill P Bopf D Beverland D
Full Access

Introduction

Radiological inclination (RI) is determined in part by operative inclination (OI), which is defined as the angle between the cup axis or handle and the sagittal plane. In lateral decubitus the theatre floor becomes a surrogate for the pelvic sagittal plane.

Critically at the time of cup insertion if the pelvic sagittal plane is not parallel to the floor either because the upper hemi pelvis is internally rotated or adducted, RI can be much greater than expected. We have developed a simple Pelvic Orientation Device (POD) to help achieve a horizontal pelvic sagittal plane.

The POD is a 3-sided square with flat footplates that are placed against the patient's posterior superior iliac spines following initial positioning (figure 1). A digital inclinometer is then placed parallel and perpendicular to the patient to give readings of internal rotation and adduction, which can then be corrected.

Methods

A model representing the posterior aspect of the pelvis was created. This permitted known movement in two planes to simulate internal rotation and adduction of the upper hemi pelvis, with 15 known pre-set positions. 20 participants tested the POD in 5 random, blinded position combinations, providing 200 readings.

The accuracy was measured by subtracting each reading from the known value.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 72 - 72
1 Jan 2018
O'Connor J Hill J Beverland D Dunne N Lennon A
Full Access

This study aimed to assess the effect of flexion and external rotation on measurement of femoral offset (FO), greater trochanter to femoral head centre (GT-FHC) distance, and neck shaft angle (NSA). Three-dimensional femoral shapes (n=100) were generated by statistical shape modelling from 47 CT-segmented right femora. Combined rotations in the range of 0–50° external and 0–50° flexion (in 10° increments) were applied to each femur after they were neutralised (defined as neck and proximal shaft axis parallel with detector plane). Each shape was projected to create 2D images representing radiographs of the proximal femora.

As already known, external rotation resulted in a significant error in measuring FO but flexion alone had no impact. Individually, neither flexion nor external rotation had any impact on GT-FHC but, for example, 30° of flexion combined with 50°of external rotation resulted in an 18.6mm change in height. NSA averaged 125° in neutral with external rotation resulting in a moderate increase and flexion on its own a moderate decrease. However, 50° degrees of both produced an almost 30 degree increase in NSA.

In conclusion, although the relationship between external rotation and FO is appreciated, the impact of flexion with external rotation is not. This combination results in apparent reduced FO, a high femoral head centre and an increased NSA. Femoral components with NSAs of 130° or 135° may historically have been based on X-ray misinterpretation. This work demonstrates that 2D to 3D reconstruction of the proximal femur in pre-op planning is a challenge.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 11 - 11
1 Jun 2017
O'Connor J Rutherford M Hill J Beverland D Dunne N Lennon A
Full Access

Unknown femur orientation during X-ray imaging may cause inaccurate radiographic measurements. The aim of this study was to assess the effect of 3D femur orientation during radiographic imaging on the measurement of greater trochanter to femoral head centre (GT-FHC) distance.

Three-dimensional femoral shapes (n=100) of unknown gender were generated using a statistical shape model based on a training data of 47 CT segmented femora. Rotations in the range of 0° internal to 50° external and 50° of flexion to 0° of extension (at 10 degree increments) were applied to each femur. A ray tracing algorithm was then used to create 2D images representing radiographs of the femora in known 3D orientations. The GT-FHC distance was then measured automatically by identifying the femoral head, shaft axis and tip of greater trochanter.

Uniaxial rotations had little impact on the measurement with mean absolute error of 0.6 mm and 3.1 mm for 50° for pure external rotation and 50° pure flexion, respectively. Combined flexion and external rotation yielded more significant errors with 10° around each axis introducing a mean error of 3.6 mm and 20° showing an average error of 8.8 mm (Figure 1.). In the cohort we studied, when the femur was in neutral orientation, the tip of greater trochanter was never below the femoral head centre.

Greater trochanter to femoral head centre measurement was insensitive to rotations around a single axis (i.e. flexion or external rotation). Modest combined rotations caused the tip of greater trochanter to appear more distal in 2D and led to deviation from the true value. This study suggests that a radiograph with the greater trochanter appearing below femoral head centre may have been acquired with 3D rotation of the femur.

For any figures or tables, please contact the authors directly by clicking on ‘Info & Metrics’ above to access author contact details.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 623 - 631
1 May 2017
Blaney J Harty H Doran E O’Brien S Hill J Dobie I Beverland D

Aims

Our aim was to examine the clinical and radiographic outcomes in 257 consecutive Oxford unicompartmental knee arthroplasties (OUKAs) (238 patients), five years post-operatively.

Patients and Methods

A retrospective evaluation was undertaken of patients treated between April 2008 and October 2010 in a regional centre by two non-designing surgeons with no previous experience of UKAs. The Oxford Knee Scores (OKSs) were recorded and fluoroscopically aligned radiographs were assessed post-operatively at one and five years.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 50 - 50
1 Jan 2017
Rutherford M Hill J Beverland D Lennon A Dunne N
Full Access

Anterior-posterior (AP) x-rays are routinely taken following total hip replacement to assess placement and orientation of implanted components. Pelvic orientation at the time of an AP x-ray can influence projected implant orientation.1However, the extent of pelvic orientation varies between patients.2Without compensation for patient specific pelvic orientation, misleading measurements for implant orientation may be obtained. These measurements are used as indicators for post-operative dislocation stability and range of motion. Errors in which could result in differences between expectations and the true outcome achieved. The aim of this research was to develop a tool that could be utilised to determine pelvic orientation from an AP x-ray.

An algorithm based on comparing projections of a statistical shape model of the pelvis (n=20) with the target X-ray was developed in MATLAB. For each iteration, the average shape was adjusted, rotated (to account for patient-specific pelvic orientation), projected onto a 2D plane, and the simulated outline determined. With respect to rotation, the pelvis was allowed to rotate about its transverse axis (pelvic flexion/extension) and anterior-posterior axis (pelvic adduction/abduction). Minimum root mean square error between the outline of the pelvis from the X-ray and the projected shape model outline was used to select final values for flexion and adduction. To test the algorithm, virtual X-rays (n=6) of different pelvis in known orientations were created using the algorithm described by Freud et al.3The true pelvic orientation for each case was randomly generated. Angular error was defined as the difference between the true pelvic orientation and that selected by the algorithm.

Initial testing has exhibited similar accuracy in determining true pelvic flexion (error = 2.74°, σerror=±2.21°) and true pelvic adduction (error = 2.38°, σerror=±1.76°). For both pelvic flexion and adduction the maximum angular error observed was 5.62°. The minimum angular error for pelvic flexion was 0.37°, whilst for pelvic adduction it was 1.08°.

Although the algorithm is still under development, the low mean, maximum, and standard deviations of error from initial testing indicate the approach is promising. Ongoing work will involve the use of additional landmarks for registration and training shapes to improve the shape model. This tool will allow surgeons to more accurately determine true acetabular orientation relative to the pelvis without the use of additional x-ray views or CT scans. In turn, this will help improve diagnoses of post-operative range of motion and dislocation stability.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 11 - 11
1 Jun 2016
O'Neill C Molloy D Patterson C Beverland D
Full Access

Introduction

Radiological Inclination (RI) is defined as the angle formed between the acetabular axis and the longitudinal axis when projected onto the coronal plane. Higher RI angles are associated with adverse outcomes.

Methods

Primary aim: to investigate the effect of adjusting patient pelvic position in the transverse plane by using a ‘head-down’ (HD) operating table position. This was to determine, when aiming for 35° Apparent Operative Inclination (AOI), which operating table position most accurately achieved a target post-operative RI of 42°.

N=270. Patients were randomised to one of three possible operating table positions:

0°HD (Horizontal),

7°HD, or

Y°HD (Patient Specific Table Position)

Operating table position was controlled using a digital inclinometer. RI was measured using EBRA software.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 34 - 34
1 Jun 2016
Magill P Blaney J Hill J Beverland D
Full Access

Introduction

The results of cementless total hip arthroplasty (THA) vary with data from the UK national Joint Registry being less favourable than that from the Australian registry. The senior author started using a fully cementless THA in 2005 and we aimed to gauge the performance of the implants based on their revision data.

Patients and methods

Between August 2005 and March 2015, 4,802 primary THA (4,309 patients) were performed with a cementless Corail® stem and a cementless Pinnacle® cup. There were 2,086 (43.4%) males and 2,716 (56.6%) females with a median age of 70 years (IQR 13, Range 16–95). There were a number of changes to the surgical technique with respect to the Corail® stem during the ten-year period, which we have categorised as phase 1 and phase 2. We compared the data in the two phases. Data were extracted from a prospectively maintained patient information database.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 341 - 348
1 Mar 2016
Ogonda L Hill J Doran E Dennison J Stevenson M Beverland D

Aims

The aim of this study was to present data on 11 459 patients who underwent total hip (THA), total knee (TKA) or unicompartmental knee arthroplasty (UKA) between November 2002 and April 2014 with aspirin as the primary agent for pharmacological thromboprophylaxis.

Patients and Methods

We analysed the incidence of deep vein thrombosis (DVT) and pulmonary embolism (PE) then compared the 90-day all-cause mortality with the corresponding data in the National Joint Registry for England and Wales (NJR).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 95 - 95
1 Jan 2016
O'Neill CK Molloy D Patterson C Beverland D
Full Access

Background

The current orthopaedic literature demonstrates a clear relationship between acetabular component positioning, polyethylene wear and risk of dislocation following Total Hip Arthroplasty (THA). Problems with edge loading, stripe wear and squeaking are also associated with higher acetabular inclination angles, particularly in hard-on-hard bearing implants.

The important parameters of acetabular component positioning are depth, height, version and inclination. Acetabular component depth, height and version can be controlled with intra-operative reference to the transverse acetabular ligament.

Control of acetabular component inclination, particularly in the lateral decubitus position, is more difficult and remains a challenge for the Orthopaedic Surgeon. Lewinnek et al described a ‘safe zone’ of acetabular component orientation: Radiological acetabular inclination of 40 ± 10° and radiological anteversion of 15 ± 10°.

Accurate implantation of the acetabular component within the ‘safe zone’ of radiological inclination is dependent on operative inclination, operative version and pelvic position.

Traditionally during surgery, the acetabular component has been inserted with an operative inclination of 45°. This assumes that patient positioning is correct and does not take into account the impact of operative anteversion or patient malpositioning.

However, precise patient positioning in order to orientate acetabular components using this method cannot always be relied upon. Hill et al demonstrated a mean 6.9° difference between photographically simulated radiological inclination and the post-operative radiological inclination. The most likely explanation was felt to be adduction of the uppermost hemipelvis in the lateral decubitus position. The study changed the practice of the senior author, with target operative inclination now 35° rather than 40° as before, aiming to achieve a post-operative radiological inclination of 42° ± 5°.

Aim

To determine which of the following three techniques of acetabular component implantation most accurately obtains a desired operative inclination of 35 degrees:

Freehand

Modified (35°) Mechanical Alignment Guide, or

Digital inclinometer assisted


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 32 - 32
1 Nov 2015
O'Neill C Molloy D Patterson C Beverland D
Full Access

Introduction

Operative inclination (OI) is defined as the angle between the acetabular axis and the sagittal plane. With the patient in the true lateral decubitus position, this corresponds to the angle formed between the handle of the acetabular component inserter and the theatre floor intra-operatively.

Patients/Materials & Methods

The primary study aim was to determine which method of acetabular component insertion most accurately allows the surgeon to obtain a target OI of 35o.

270 consecutive patients undergoing cementless THA were randomised to one of three possible methods for acetabular component implantation:

1. Freehand,

2. 35o mechanical alignment guide (MAG), or

3. Digital inclinometer assisted

Two surgeons participated. Target OI was 35o in all cases. OI was measured using a digital inclinometer. For the freehand and MAG cases, the surgeon was blinded to inclinometer readings intra-operatively.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 38 - 38
1 Feb 2015
Beverland D
Full Access

Ideal cup positioning remains elusive both in terms of defining and achieving target.

Our aim is to restore original anatomy by using the Transverse Acetabular Ligament (TAL). In the normal hip TAL and labrum come beyond the equator of the femoral head therefore if the definitive cup is positioned such that: It is cradled by the TAL; Is ideally no more than 4mm greater in diameter than the original femoral head; Sits just deep to the plane of TAL and labrum (this means that normally we leave the fat pad intact and do not ream down to the true floor).

That should restore joint center in terms of height and offset. If the face of the cup is then positioned parallel and just deep to the TAL and psoas groove that should restore original version. We still use TAL for version in dysplasia because we believe the TAL and labrum compensate for any underlying bony abnormality. However in dysplasia the TAL and labrum fall short of original femoral head equator and therefore in such cases we ream down to the true floor if necessary and use a cup which is often smaller than the original head.

Inclination represents a greater challenge and TAL should not be used as an aid to inclination. Our research has shown that errors in postoperative x-ray inclination above 50 degrees are generally caused by errors in patient positioning when in lateral decubitus. Consequently great care needs to be taken when positioning the patient.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 127 - 127
1 Feb 2015
Beverland D
Full Access

Historically correction of deformity in primary TKA has involved release of collateral ligaments to correct deformity. This has been common to both measured resection and gap balancing techniques but particularly the former. Essentially the collateral ligaments have been released to balance the bone cuts. Another philosophy is to consider that the collateral ligaments do not contract and should never be released. After sacrificing both cruciates I use a tibia first technique. The AP femoral cuts are done by using collateral ligament tension to set femoral rotation and create a rectangular flexion gap which is then measured

A five degree conservative or precut is then made on the distal femur. Critically all osteophytes have now been removed. The extension gap is assessed using a spacer block. In a varus knee the definitive cut is frequently made in more varus to create a balanced extension gap to equal the flexion gap. It is rare to have to release the posteromedial capsule.

In contrast in severe fixed valgus the posterolateral capsule frequently has be cut before the definitive distal femora cut is made. The latter is often in more valgus. I never resurface the patella but ensure good patellar tracking after inserting a cementless mobile bearing knee which is used irrespective of deformity. I am more concerned about gap balance than the mechanical axis.

Essentially the concept proposed is to cut the bone to balance the soft tissues as opposed to the reverse. The aim is to restore pre-morbid alignment and not necessarily a neutral mechanical axis.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 19 - 19
1 Mar 2013
Pagoti R Dennison J Beverland D
Full Access

Salvage Total Hip Arthroplasty (THA) presents a viable solution following failed treatment of a hip fracture. Several studies have suggested higher complication rate including high dislocation rate associated with salvage THA. The present study evaluates the results and complications of hip arthroplasty performed as a salvage procedure after the failed treatment of a hip fracture and comparison made to Primary THA in osteoarthritis (OA). Between 1992 and 2007, 53 patients with a mean age of seventy years were treated with THA after the failed treatment of a hip fracture under the care of a single surgeon. The indication for conversion arthroplasty was Avascular necrosis head – 24(45.3%), screw cut out – 6 (11.3%), non-union – 2(3.8%), Displaced fracture – 2(3.8%), Secondary OA – 19 (35.8%). The implants retrieved were Cannulated screws – 3, Sliding plate and screw – 46, Spline plate – 2, Smith Petersons nail – 1, Martin Plate – 1. This group of patients were matched for age, sex, side, and ASA grading with a group of 59 patients who underwent THA for primary osteoarthritis (THA-OA group). Posterior approach was used in all cases. Four patients (7.5%) required grafting of cup and 21 patients (39.6%) required soft tissue release. The average blood loss was 555 ml, mean duration of surgery was 85.5 min, average inpatient stay was 6.7 days. Cemented THA was used in 43 patients and Cementless THA in 10 patients. At one year follow up there were no dislocations, one patient had an undisplaced femoral fracture treated in Spica. Three patients had broken screws; one patient with shortening > 1 inch. There was one revision for deep infection. The mean Harris Hip Score (HHS) improved from 28.4 to 82.5 at one year, while the Oxford Hip score (OHS) improved from 50.9 to 21.9 (Old system). When the scores were compared to the THA-OA group there was no difference in the oxford hip scores and the the mean one year HHS in the THA-OA group was slightly higher than the group with salvage THA, but the difference was not statistically significant. Hip arthroplasty is an effective salvage procedure in patients with prior surgery for hip fracture. Most patients have good pain relief and functional improvement. Despite the operative challenges, remarkably few serious orthopaedic complications were associated with this procedure in the present study.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 71 - 71
1 Sep 2012
Hanratty B Thompson N Bennett D Robinson A Mullan C Beverland D
Full Access

Increasing knee flexion following total knee arthroplasty (TKA) has become an important outcome measure. Surgical technique is one factor that can influence knee motion. In this study, it was hypothesised that stripping of the posterior knee capsule could improve flexion and range of motion (ROM) following TKA. Patients who were undergoing TKA were prospectively randomised into two groups - one group (62 patients) were allocated stripping of the posterior knee capsule (PCS), the other group (66 patients) no stripping (no-PCS). The primary outcome was change in flexion and ROM compared to pre-operative measurements at three time points; after wound closure, 3months and 1year post-operatively. Secondary outcomes were absolute measurements of flexion, extension, ROM and complications. All operations were performed by a single surgeon using the same implant and technique. All patients received identical post-operative rehabilitation. There was a significant gain in flexion after wound closure in the PCS group (p=0.022), however there was no significant difference at 3months or 1year post-operatively. Absolute values of extension (p=0.008) and flexion (p=0.001) 3months post-operatively were significantly reduced for the PCS group. The absolute value of ROM was significantly higher for the no-PCS group at 3months (p=0.0002) and 1year (p=0.005). There were no significant difference in the rate of complications. Posterior capsular stripping causes a transient increase in flexion that does not persist post-operatively. We do not recommend routine stripping of the posterior knee capsule in patients undergoing TKA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 9 - 9
1 Mar 2012
Pagoti R O'Brien S Doran E Beverland D
Full Access

A prospective study of 276 TKA's performed in patients with valgus knee deformity ≥ 10° using a Modified Surgical Technique.

MATERIALS AND METHODS

Bone cuts were used to balance the valgus knee and soft tissue release was confined to the postero-lateral capsule in severe deformity. The aim was to restore a “functional mechanical axis” as opposed to a “neutral” mechanical axis. All surgeries were performed between Jan2003 and Apr2007, under the care of a single surgeon using an LCS rotating platform. All patients had full length radiographs and outcome scores collected prospectively.

RESULTS

The mean coronal alignment of the lower limb was corrected from 15.9°(10-45°) to 3.8°. 94% patients had their coronal alignment restored to = 7°. Sixteen knees with postoperative valgus ≥8° were analysed as a separate group. The mechanical axis deviation was corrected from 52.3mm to 8.8mm. The distal femoral cut was made at 5° valgus in 131 knees(47.5%), 6° in 111 knees(40.2%) and 7° in 24 knees(8.7%).78 knees(28%) were balanced only with bone cuts. 198 knees(72%) had release of posterolateral capsule. 16 knees(5.8%) also had release of IT band. Lateral patellar release was performed in 39 knees (14%) and 23 knees had patella contouring. 93%knees had central patello-femoral alignment postoperatively. One spinout was managed by closed reduction and a second patient had revision of tibial tray for collapse. Patellar subluxation occurred in two patients. The oxford knee score and the American Knee Society clinical score improved from 48.5 to 26 and 21.04 to 86.03 respectively.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 1 - 1
1 Mar 2012
Cusick L Monk J Boldt J Beverland D
Full Access

Introduction

The addition of hydroxyapatite in cementless total knee arthroplasty is believed to reduce the time for implant fixation and rehabilitation, reduce the incidence of RLLs and provide long lasting implant stability, through improved osseointegration. We report the results of a prospective, randomised controlled single blinded study comparing the post operative pain, biological fixation and clinical outcomes with the LCS Complete Porocoat and the hydroxyapatite-coated, LCS Complete Duofix mobile-bearing knee systems.

Methods

Two hundred and four patients for TKA were prospectively recruited into the study between November 2006 and November 2008. Subjects were randomly assigned to receive the LCS Complete Duofix or LCS Complete Porocoat knee systems. Outcomes including VAS pain scores, American Knee Society scores and Oxford knee scores were performed pre-operatively and at 3 months. X-rays were analysed by an independent reviewer for the presence of radiolucent lines.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1021 - 1026
1 Aug 2011
Kalteis T Sendtner E Beverland D Archbold PA Hube R Schuster T Renkawitz T Grifka J

Orientation of the native acetabular plane as defined by the transverse acetabular ligament (TAL) and the posterior labrum was measured intra-operatively using computer-assisted navigation in 39 hips. In order to assess the influence of alignment on impingement, the range of movement was calculated for that defined by the TAL and the posterior labrum and compared with a standard acetabular component position (abduction 45°/anteversion 15°).

With respect to the registration of the plane defined by the TAL and the posterior labrum, there was moderate interobserver agreement (r = 0.64, p < 0.001) and intra-observer reproducibility (r = 0.73, p < 0.001). The mean acetabular component orientation achieved was abduction of 41° (32° to 51°) and anteversion of 18° (−1° to 36°). With respect to the Lewinnek safe zone (abduction 40° ±10°, anteversion 15° ±10°), 35 of the 39 acetabular components were within this zone. However, there was no improvement in the range of movement (p = 0.94) and no significant difference in impingement (p = 0.085).

Alignment of the acetabular component with the TAL and the posterior labrum might reduce the variability of acetabular component placement in total hip replacement. However, there is only a moderate interobserver agreement and intra-observer reliability in the alignment of the acetabular component using the TAL and the posterior labrum. No reduction in impingement was found when the acetabular component was aligned with the TAL and the posterior labrum, compared with a standard acetabular component position.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 41 - 41
1 Jan 2011
Cusick L Beverland D
Full Access

In response to the recent publication in April 2007 of NICE guidelines on venous thromboembolism, we report our practice and experience of VTE in adult hip and knee arthroplasty.

It is generally agreed that the 2 major complications of VTE are sudden death as a result of pulmonary embolism and post thrombotic syndrome. NICE guidelines make 2 assumptions:

That chemical and mechanical prophylaxis can reduce these complications

That Orthopaedic surgery, in particular elective Primary Joint Replacements are particularly high risk procedures with respect to these 2 complications.

We have studied a large cohort of patients who had Aspirin only as chemical prophylaxis to determine the incidence of clinical thromboembolism before and after discharge and the mortality from PE at 90 days. We performed a prospective analysis of consecutive patients undergoing primary total knee and hip replacement from November 2002 to November 2007. In total 2050 patients had total knee replacement and 2203 patients had total hip replacement. All patients were treated at one specialist centre under the care of one surgeon. Data was complete and accurate for all patients at 90 days post-operatively.

Standard practice was the use of 150mg Aspirin from Day 1 post-operatively for a total of six weeks combined with spinal anaesthesia and early mobilisation.

The overall rate for Fatal Pulmonary embolism 0.07% (3/4253), overall death rate 0.3%(13/4253), for treated non-fatal PE 0.66% (28/4253) and for treated above knee DVT was 0.33%(14/4253).

Our data suggests that fatal pulmonary embolism is not common and does not account for most deaths following total hip and knee arthroplasty. We suggest there is no evidence that chemical/mechanical prophylaxis reduces the risk of sudden death from PE following elective primary joint replacement and with modern surgical practice elective hip and knee replacement should no longer be considered high risk procedures.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 536 - 537
1 Oct 2010
Hanratty B Bennett D Beverland D Thompson N
Full Access

Introduction: Range of motion (ROM) is an important measure of the success of knee Arthroplasty. The extent to which pain relief contributes to improvements in knee ROM in total knee Arthroplasty (TKA) patients is unknown. This prospective study assessed the separate effects of pain abolition and surgery on ROM in a group of 141-osteoathritic patient’s undergoing TKA. Pain had a significant inhibitory effect on knee ROM. Improvements in ROM following TKA may be primarily due to pain relief.

Methods: 141 randomly selected patients underwent LCS total knee arthroplasty (De Puy). A single surgeon performed all operations, using an identical surgical technique. Passive flexion and extension were measured when awake, under anaesthesia, and post-operatively under anaesthesia.

Paired t-tests were used to test for significant differences between the measurements. Independent samples t-tests were used to test for significant differences between the changes in flexion, extension and ROM between the time points tested.

Results:

When awake the mean flexion was 116.8°, extension 3.8°, and ROM 113.0°

When anaesthetised pre-op, the flexion was 130.2°, extension 0.8°, and ROM 129.4°.

When anaesthetised post-op the flexion was 133.8°, extension 0.2°, and the ROM 133.5°.

Knee flexion (p < 0.0001) and range of motion (p < 0.0001) were significantly greater and knee extension (p < 0.0001) was significantly reduced following anaesthesia only. A further significant increase in knee flexion (p < 0.0001) and range of motion (p = 0.00014) was observed post –operatively under anaesthetic. However knee extension did not significantly increase further (p = 0.29). The average improvement in range of motion once anaesthetised was 16.4° (SD = 13.1°) with the majority of this improvement due to an increase of flexion (average increase of 13.4° (SD = 11.9°) rather than an increase in extension (average increase of 3.0° (SD = 4.2°).

The combined effect of surgery and anaesthetic was 20.5° (SD = 12.3°), with the majority of this improvement due to an increase of flexion (average increase of 17° (SD = 8.5°) rather than an increase in extension (average increase of 3.6° (SD = 6.0°).

Discussion: Pain abolition resulted in a mean increase of 16.4° in the range of motion, and both TKA combined with pain abolition further increased significantly the range of motion to a mean of 20.5°. This study suggests that improvements in ROM following total knee arthroplasty are primarily due to reduction in the symptoms of pain and that other factors such as surgical technique and prosthesis design can further increase ROM.

Future studies should record the measurements of passive flexion, extension and range of motion in the anaesthetised patient, as this will allow objective assessment of changes in range of movement.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 494 - 494
1 Oct 2010
Cusick L Beverland D
Full Access

In response to the recent publication in April 2007 of NICE guidelines on venous thromboembolism, we report our practice and experience of VTE in adult hip and knee arthroplasty. It is generally agreed that the 2 major complications of VTE are sudden death as a result of pulmonary embolism and post thrombotic syndrome. NICE guidelines make 2 assumptions:

That chemical and mechanical prophylaxis can reduce these complications

That Orthopaedic surgery, in particular elective Primary Joint Replacements are particularly high risk procedures with respect to these 2 complications.

We have studied a large cohort of patients who had Aspirin only as chemical prophylaxis to determine the incidence of clinical thromboembolism before and after discharge and the mortality from PE at 90 days. We performed a retrospective analysis of consecutive patients undergoing primary total knee and hip replacement from November 2002 to November 2007. In total 2050 patients had total knee replacement and 2203 patients had total hip replacement. All patients were treated at one specialist centre under the care of one surgeon. Data was complete and accurate for all patients at 90 days post-operatively. Standard practice was the use of 150mg Aspirin from Day 1 post-operatively for a total of six weeks combined with spinal anaesthesia and early mobilisation. The overall rate for Fatal Pulmonary embolism 0.07% (3/4253), overall death rate 0.31%(13/4253), for treated non-fatal PE 0.66% (28/4253) and for treated above knee DVT was 0.33%(14/4253). Our data suggests that fatal pulmonary embolism is not common and does not account for most deaths following total hip and knee arthroplasty. We suggest there is no evidence that chemical/mechanical prophylaxis reduces the risk of sudden death from PE following elective primary joint replacement and with modern surgical practice elective hip and knee replacement should no longer be considered high risk procedures.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 420 - 420
1 Jul 2010
McConway JHF Wilson R Molloy D O’Brien S Archbold P Beverland D
Full Access

Aim: To develop a flexion jig that would reliably hold the post-op knee in fixed flexion for a defined time period and determine its influence on peri-operative blood loss, transfusion, pain, and complications (specifically nerve palsy)following TKA.

Methods/Results: A previous study in this department showed immediate postoperative flexion to significantly reduce blood loss following TKR. Following this study, time in flexion was increased to 12 hours in an attempt to further reduce blood loss., some patients then developed a painful lower limb nerve palsy. This palsy was caused by pressure from the jig in the popliteal fossa/calf on nerves. The design of the jig was altered to remove pressure from these areas. Because of this design change, we were unsure whether the new jig would have the same blood saving effect, necessitating a new study.

This prospective randomised controlled trial recruited 420 patients into 3 equal groups: extension, 3 & 6 hrs flexion.

This trial found a significant reduction in blood loss(12%, p=0.006) and length of stay(1/2 day, p=0.006) in the 6 hour flexion group, compared the extension group.

There was no significant difference in pain or complication rates (excluding nerve palsy).

2 patients in the 6 hour group had postoperative nerve palsy, however, this palsy was sensory only and markedly different to that found previously. Although the palsy rate in this study is similar(1.4%) to quoted literature rates (1.3%) for TKA, it is difficult to know if the jig was the cause of palsy as the there was a difference between those caused by the old metal jig (painful) and those in this study (sensory loss only).

Conclusion: The results of this study show post-op flexion for 6 hours to significantly reduce perioperative blood loss. Palsy was reduced to match rates as quoted in the literature.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 49 - 49
1 Mar 2010
Cusick L Beverland D
Full Access

Following the recent publication in April 2007 of NICE guidelines on venous thromboembolism, we report our practice and experience of VTE in adult hip and knee arthroplasty.

It is generally agreed that the 2 major complications of VTE are sudden death as a result of pulmonary embolism and post thrombotic syndrome. NICE guide-lines make 2 assumptions:

That chemical and mechanical prophylaxis can reduce these complications

That Orthopaedic surgery, in particular elective Primary Joint Replacements are particularly high risk procedures with respect to these 2 complications.

Methods and Results: We have studied a large cohort of patients who had Aspirin only as chemical prophylaxis to determine the incidence of clinical thromboembolism before and after discharge and the mortality from PE at 90 days.

We performed a retrospective analysis of consecutive patients undergoing primary total knee and hip replacement from November 2002 to November 2007. In total 2050 patients had total knee replacement and 2203 patients had total hip replacement. All patients were treated at one specialist centre under the care of one surgeon. Data was complete and accurate for all patients at 90 days post-operatively.

Standard practice was the use of 150mg Aspirin from Day 1 post-operatively for a total of six weeks combined with spinal anaesthesia and early mobilisation.

The overall rate for Fatal Pulmonary embolism 0.07% (3/4253), overall death rate 0.31%(13/4253), for treated non-fatal PE 0.66% (28/4253) and for treated above knee DVT was 0.33%(14/4253).

Conclusion: Our data suggests that fatal pulmonary embolism is not common and does not account for most deaths following total hip and knee arthroplasty. We suggest there is no evidence that chemical/mechanical prophylaxis reduces the risk of sudden death from PE following elective primary joint replacement and with modern surgical practice elective hip and knee replacement should no longer be considered high risk procedures.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 290 - 290
1 May 2009
Hanratty B Wilson R Thompson N Beverland D
Full Access

Purpose: The study objective was to measure ‘posterior condylar offset’ (PCO), and tibial slope (TS) following cruciate-sacrificing total knee arthroplasty (TKA), and determine any influence on one-year flexion values following cruciate-sacrificing Total Knee Arthroplasty.

The term ‘posterior condylar offset’ (PCO) is defined as the distance from a line projected along the posterior cortex of the femur to the maximum convexity of the posterior condyles. Its magnitude has been found to correlate with final flexion following PCL-retaining TKA, if reduced by more than 3mm post-operatively. (1)

Tibial slope is the angle between a line drawn parallel to the articular surface and a line drawn perpendicular to the long axis of the tibia on a lateral radiograph. Increasing the tibial slope in PCL-retaining TKA has been shown to improve maximal flexion of an average 1.7 degrees flexion for every extra degree on the tibial slope. (2)

Method: We reviewed the pre and post-operative radiographs of 69 patients who had undergone cruciate-sacrificing TKA. All cases were performed by a single surgeon using the same operative technique. Preoperative and postoperative true lateral radiographs were used to measure the change in PCO and the TS. Pre-operative and one-year flexion was measured using a goniometer.

Results: There were 26 males and 43 females. Mean age was 68 years (range 38 – 87). 67 of the patients had a primary diagnosis of OA, the remaining 2 patients RA.

The mean pre-operative PCO was 25.9 mm (21 – 35), whilst the mean post-operative PCO was 26.9 mm (21 – 34). The difference in preoperative and postoperative PCO ranged from −6 mm to + 5 mm (average, +1mm).

Three patients 4% had more than 3mm reduction in their PCO following TKA (range −4mm to −6mm). 16% had their post-operative PCO increased by more than 3mm (range 4mm – 5mm). The remaining 80% had their PCO restored to within 3mm either way.

The mean post operative tibial slope was 6.6° with a range of 5–9°, 38% measuring 6°, 21% at 7°, 17% at 8°and 5° and the remaining 7% at 9°.

Of the three patients whose PCO was reduced by more than 3mm, one had the same flexion 1 year postoperatively, one had an increase of 14 degrees, and unfortunately the third died before their 1 year review.

Using regression analysis, the strongest predictor of one-year flexion for this study group was the preoperative flexion value. The change in PCO and angle of the tibial slope had no significant influence on one-year flexion.

Conclusion: It would appear that the LCS technique permits satisfactory restoration of PCO and consistent tibial slope as only 4% of patients in this study had a decrease in PCO of more than 3mm and the range of tibial slope was within 5°. We feel these parameters are important however in this study it did not have significant influence on final flexion.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 296 - 296
1 Jul 2008
Archbold HAP Mockford B Molloy D McConway J Ogonda L Beverland D
Full Access

Introduction: A critical determinant of early dislocation following total hip arthroplasty (THA) is correct positioning of the acetabular component. This challenging aspect of THA has not been lessened by the introduction of more minimally invasive techniques. In this paper we introduce a simple and reproducible technique, which uses the transverse acetabular ligament (TAL) to determine cup orientation. We have used this technique as the sole method of cup orientation in our last 1000 consecutive primary total hips.

Methods: One thousand consecutive patients were studied in order to determine the prevalence of early dislocation (within 3 months) following acetabular component placement determined by reference to the transverse ace-tabular ligament. All patients underwent primary total hip arthroplasty via a posterolateral approach with a posterior repair.

Results: At a minimum follow-up of 9 months (range 9–39 months) 6 of the 1000 hips (0.6%) had dislocated.

Conclusion: Although multiple factors are known to contribute to this rate correct placement of the acetabular component is critical. As our results compare favourably with other published series where a posterior repair has been performed by extrapolation we feel that that the TAL does provide an acceptable method of determining cup orientation. The fact that it is independent of patient position on the table and is easy to locate with a minimally invasive approach makes it an attractive method.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1581 - 1585
1 Dec 2007
McConway J O’Brien S Doran E Archbold P Beverland D

Between April 1992 and July 2005, 310 posterior lip augmentation devices were used for the treatment of recurrent dislocation of the hip in 307 patients who had received primary total hip replacements (THRs) using Charnley/Charnley Elite components with a cemented acetabulum. The mean number of dislocations before stabilisation with the device was five (1 to 16) with a mean time to this intervention from the first dislocation of 3.8 years (0 days to 22.5 years). The mean age of the patients at this reconstruction was 75.4 years (39 to 96).

A retrospective clinical and radiological review was carried out at a mean follow-up of six years and nine months (4.4 months to 13 years and 7 months). Of the 307 patients, 53 had died at the time of the latest review, with a functioning THR and with the posterior lip augmentation device in situ. There were four revisions (1.3%), one for pain, two for deep infection and one for loosening of the acetabular component. Radiolucent lines around the acetabular component increased in only six cases after insertion of the device which was successful in eliminating instability in 302 patients, with only five further dislocations (1.6%) occurring after its insertion.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 883 - 886
1 Jul 2006
Archbold HAP Mockford B Molloy D McConway J Ogonda L Beverland D

Ensuring the accuracy of the intra-operative orientation of the acetabular component during a total hip replacement can be difficult. In this paper we introduce a reproducible technique using the transverse acetabular ligament to determine the anteversion of the acetabular component. We have found that this ligament can be identified in virtually every hip undergoing primary surgery. We describe an intra-operative grading system for the appearance of the ligament. This technique has been used in 1000 consecutive cases. During a minimum follow-up of eight months the dislocation rate was 0.6%. This confirms our hypothesis that the transverse acetabular ligament can be used to determine the position of the acetabular component. The method has been used in both conventional and minimally-invasive approaches.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 255 - 255
1 May 2006
Mockford B Thompson N Humphreys P Beverland D
Full Access

Objective: To determine if a standard course of outpatient physiotherapy improves the range of knee motion following primary total knee arthroplasty.

Design: One hundred and fifty patients undergoing primary total knee arthroplasty were recruited and randomly assigned into two groups. Group 1 received a course of physiotherapy with a standard protocol over a six week period within 4 weeks of hospital discharge. Group 2 received no outpatient physiotherapy. All patients received inpatient physiotherapy for the length of their hospital stay. Range of knee motion was measured using a goniometer by members of the outcome team blinded to the randomisation. Validated knee scores (Oxford knee and Bartlet patellar) were collected. An SF12 health questionnaire was used as a generic outcome measure.

Results: Both groups were equally matched by age and sex. Although patients in Group 1 achieved greater range of knee motion than those in Group 2 this was not statistically significant. No difference was also noted in any of the outcome measures used.

Conclusion: We conclude that in patients undergoing primary total knee arthroplasty, inpatient physiotherapy with good instructions and a well-structured home exercise regime can dispense with the need for outpatient physiotherapy.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 254 - 254
1 May 2006
Molloy D Ogonda L Beverland D
Full Access

Objective: To examine the impact of aspirin and non-steroidal anti-inflammatory drugs (NSAIDs) on preoperative haemoglobin levels and perioperative transfusion rates in patients undergoing total knee arthroplasty (TKA).

Methods: We examined the pre-operative haemoglobin (Hb) and haematocrit (Hct) of a consecutive series of 81 patients, looking at the relationship between the pre-operative use of Aspirin/NSAIDs on preoperative Hb, postoperative Hb deficit and the perioperative transfusion rate. A single surgeon performed all procedures using an LCS TKR (Depuy, Leeds UK). A standardised transfusion protocol was used.

Results: The patients were grouped according to their pre-operative use of aspirin or a NSAID, singly or in combination. The patient groups are as shown in the table below. All groups were comparable for age, BMI and ASA grade.

Results show a significantly higher transfusion rate (p=0.048) in the group of patients who received a combination of aspirin and a NSAID compared to the other groups. The patients on aspirin or a NSAID alone also had an increased transfusion rate but the increase was not statistically significant (p=0.12 and p=0.07 respectively).

Conclusion: The use of both aspirin and an NSAID in combination leads to a lower preoperative Hb and an increased post-operative transfusion requirement following total knee arthroplasty.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 281 - 281
1 May 2006
Archbold P Mohammed M O’Brien S Molloy D Beverland D
Full Access

Current methods for restoring or preserving limb length following total hip arthroplasty are anatomically inaccurate, as they do not consider acetabular and femoral height independently. In order to address this, we present and evaluate a technique that uses the transverse acetabular ligament to control the vertical height of the acetabular component and a caliper that controls the vertical placement of the femoral component within the femoral canal. Limb lengths were measured in 200 patients who had undergone primary total hip arthroplasty using this technique. Using this method, 94% had a post-operative limb length inequality that was 6 mm or less when compared to the normal side (average +0.38 mm). The maximum measured limb length inequality was ± 8 mm.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 281 - 281
1 May 2006
Archbold P Slomczykowski M Beverland D
Full Access

Background: The positioning of the acetabular component is of critical importance in total hip arthroplasty. Due to the orientation of the acetabulum and limitations of observation imposed at the operative site mal-positioning is common. We believe that by utilising the transverse acetabular ligament (TAL) and acetabular labrum, we are able to anatomically position our cup. In this study, we evaluate the correlation between placement of the acetabular component by reference to the TAL and the acetabular labrum with the taught safe zones for cup placement.

Method: 7 embalmed hips were studied. Following disarticulation the labrum and TAL were digitised and their plane was calculated. Orientation of cup placement in this plane was calculated from a pre-dissection pelvic CT.

Results: The plane of the labrum/TAL varied between 5–26° of anteversion and 32–59° of inclination. Interob-server differences in acetabular cup placement based on the TAL/labral plane indicate reasonable coherence. Almost all components were inside the documented “safe zone” 0–40° of anteversion and 30–55° of inclination of placement.

Conclusion: The acetabular labrum and TAL form a plane that reflects the documented “safe zones” for acetabular component placement. We feel that this plane allows a surgeon to determine optimal patient specific acetabular component placement, irrespective of patient position.