header advert
Results 1 - 47 of 47
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 31 - 31
1 Dec 2022
Sheridan G Clesham K Greidanus NV Masri B Garbuz D Duncan CP Howard L
Full Access

To date, the literature has not yet revealed superiority of Minimally Invasive (MI) approaches over conventional techniques. We performed a systematic review to determine whether minimally invasive approaches are superior to conventional approaches in total hip arthroplasty for (1) clinical and (2) functional outcomes. We performed a meta-analysis of level 1 evidence to determine whether (3) minimally invasive approaches are superior to conventional approaches for clinical outcomes.

All studies comparing MI approaches to conventional approaches were eligible for analysis. The PRISMA guidelines were adhered to throughout this study. Registries were searched using the following MeSH terms: ‘minimally invasive’, ‘muscle-sparing’, ‘THA’, ‘THR’, ‘hip arthroplasty’ and ‘hip replacement’. Locations searched included PubMed, the Cochrane Library, ClinicalTrials.gov, the EU clinical trials register and the International Clinical Trials Registry Platform (World Health Organisation).

Twenty studies were identified. There were 1,282 MI THAs and 1,351 conventional THAs performed.

There was no difference between MI and conventional approaches for all clinical outcomes of relevance including all-cause revision (p=0.959), aseptic revision (p=0.894), instability (p=0.894), infection (p=0.669) and periprosthetic fracture (p=0.940).

There was also no difference in functional outcome at early or intermediate follow-up between the two groups (p=0.38).

In level I studies exclusively, random-effects meta-analysis demonstrated no difference in the rate of aseptic revision (p=0.461) between both groups.

Intermuscular MI approaches are equivalent to conventional THA approaches when considering all-cause revision, aseptic revision, infection, dislocation, fracture rates and functional outcomes. Meta-analysis of level 1 evidence supports this claim.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 99 - 99
1 Jul 2020
El-Husseiny M Masri BA Duncan CP Garbuz D
Full Access

High complication rates and poor outcomes have been widely reported in patients undergoing revision of large head metal-on-metal arthroplasty. A previous study from our centre showed high rates of dislocation, nerve injury, early cup loosening and pseudotumor recurrence. After noting these issues, we implemented the following changes in surgical protocol in all large head MOM revisions: One: Use of highly porous shells in all cases. Two: Use of largest femoral head possible. Three: Low threshold for use of dual mobility and constrained liners when abductors affected or absent posterior capsule. Four: Use of ceramic head with titanium sleeve in all cases. Five: Partial resection of pseudotumor adjacent to sciatic and femoral nerves.

The purpose of the present study is to compare the new surgical protocol above to our previously reported early complications in this group of patients

We specifically looked at (1) complications including reoperations, (2) radiologic outcomes, and (3) functional outcomes. Complication rates after (Group 1), and before (Group 2) modified surgical protocol were compared using Chi-square test, assuming statistical significance p < 0 .05.

Major complications occurred in 4 (8.3%) of 48 patients who had modified surgical technique, compared to 12 (38%) of 32 revisions prior to modification (p < 0 .05). Two hips of 48 (4.17%) endured dislocations in Group 1, compared to 9 of 32 (28%) in Group 2 (p < 0 .05). Four patients of 48 had repeat revision in Group 1: 2 for recurrence of pseudotumor, 1 for dislocation, and 1 for infection, compared to 6 patients who had 7 repeat revisions of 32 patients in Group 2: 3 for acetabular loosening, 3 for dislocation, and 1 for recurrence of pseudotumor (p=0.1). None of 48 revisions in Group 1 had acetabular loosening, compared to 4 of 32 in Group 2 (p=0.02). Two patients had nerve injury in Group 2, compared to none in Group 1 (p=0.16). The mean WOMAC pain score was 87.1 of 100 and the function score was 88.4 of 100 in Group 1, compared to a mean WOMAC pain score of 78 of 100 (p=0.6) and a function score of 83 of 100 in Group 2 (p=0.8).

Modification of the surgical techniques described in the introduction has resulted in a significant decrease in complications in revision of large head MOM total hips. We continue to use this protocol and recommend it for these difficult cases.


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 112 - 115
1 Jul 2020
Waly FJ Garbuz DS Greidanus NV Duncan CP Masri BA

Aims

The practice of overlapping surgery has been increasing in the delivery of orthopaedic surgery, aiming to provide efficient, high-quality care. However, there are concerns about the safety of this practice. The purpose of this study was to examine the safety and efficacy of a model of partially overlapping surgery that we termed ‘swing room’ in the practice of primary total hip (THA) and knee arthroplasty (TKA).

Methods

A retrospective review of prospectively collected data was carried out on patients who underwent primary THA and TKA between 2006 and 2017 in two academic centres. Cases were stratified as partially overlapping (swing room), in which the surgeon is in one operating room (OR) while the next patient is being prepared in another, or nonoverlapping surgery. The demographic details of the patients which were collected included operating time, length of stay (LOS), postoperative complications within six weeks of the procedure, unplanned hospital readmissions, and unplanned reoperations. Fisher's exact, Wilcoxon rank-sum tests, chi-squared tests, and logistic regression analysis were used for statistical analysis.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 20 - 20
1 Oct 2019
Masri BA Waly F Duncan CP Greidanus NV Garbuz DS
Full Access

Introduction

The practice of overlapping surgery has been increasing in the delivery of orthopaedic care, aiming to provide efficient, high-quality care. However, there have been concerns about the safety of this practice. The purpose of this study is to examine safety and efficacy of a model of partially overlapping surgery that we termed “the swing room” in practice in primary hip and knee arthroplasty.

Methods

A retrospective review of prospectively collected data using an administrative database was carried out on patients who underwent primary unilateral total hip and total knee arthroplasty from 2006 to 2017 at two sites of one academic center staffed by four arthroplasty surgeons. All revisions and bilateral primary procedures were excluded. Cases were stratified as overlapping or non-overlapping. Overlapping was defined when a surgeon had access to two operating rooms with two teams, and non-overlapping was defined as when a surgeon only had access to a single operating room on a particular day. Patient demographic characteristics, operating room time, procedure time, length of stay, Postoperative complications within 30 days of the procedure, unplanned hospital readmissions, unplanned reoperations, and emergency department visits were collected. The Fisher's exact Wilcoxon rank-sum test and logistic regression analysis were used for statistical analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 72 - 72
1 Oct 2018
El-Husseiny M Masri BA Duncan CP Garbuz DS
Full Access

Background

Fully constrained liners are used to treat recurrent dislocations or patients at high risk after total hip replacements. However, they can cause significant morbidities including recurrent dislocations, infections, aseptic loosening and fractures. We examine long term results of 111 patients with tripolar constrained components to assess their redislocation and failure rate.

Questions/purposes

The purpose of this study was to assess survivorship, complications and functional outcomes at a minimum 10 years after the constrained tripolar liners used in our institute.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 73 - 73
1 Oct 2018
El-Husseiny M Masri BA Duncan CP Garbuz DS
Full Access

Background

High complication rates and poor outcomes have been widely reported in patients undergoing revision of large head metal-on-metal arthroplasty. A previous study from our center showed high rates of dislocation, nerve injury, early cup loosening and pseudotumor recurrence. After noting these issues, we implemented the following changes in surgical protocol in all large head MOM revisions: 1. Use of highly porous shells in all cases 2. Use of largest femoral head possible 3. Low threshold for use of dual mobility and constrained liners when abductors affected or absent posterior capsule 4. Use of ceramic head with titanium sleeve in all cases 5. Partial resection of pseudotumor adjacent to sciatic and femoral nerves.

Questions/purposes

The purpose of the present study is to compare the new surgical protocol above to our previously reported early complications in this group of patients

We specifically looked at (1) complications including reoperations; (2) radiologic outcomes; and (3) functional outcomes. Complication rates after (Group 1), and before (Group 2) modified surgical protocol were compared using Chi-square test, assuming statistical significance p<0.05.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 720 - 724
1 Jun 2018
Waterson HB Whitehouse MR Greidanus NV Garbuz DS Masri BA Duncan CP

Aims

Fretting and corrosion at the modular head/neck junction, known as trunnionosis, in total hip arthroplasty (THA) is a cause of adverse reaction to metal debris (ARMD). We describe the outcome of revision of metal-on-polyethylene (MoP) THA for ARMD due to trunnionosis with emphasis on the risk of major complications.

Patients and Methods

A total of 36 patients with a MoP THA who underwent revision for ARMD due to trunnionosis were identified. Three were excluded as their revision had been to another metal head. The remaining 33 were revised to a ceramic head with a titanium sleeve. We describe the presentation, revision findings, and risk of complications in these patients.


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 44 - 49
1 Jan 2018
Berstock JR Whitehouse MR Duncan CP

Aims

To present a surgically relevant update of trunnionosis.

Materials and Methods

Systematic review performed April 2017.


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 17 - 21
1 Jan 2018
Konan S Duncan CP

Patients with neuromuscular imbalance who require total hip arthroplasty (THA) present particular technical problems due to altered anatomy, abnormal bone stock, muscular imbalance and problems of rehabilitation.

In this systematic review, we studied articles dealing with THA in patients with neuromuscular imbalance, published before April 2017. We recorded the demographics of the patients and the type of neuromuscular pathology, the indication for surgery, surgical approach, concomitant soft-tissue releases, the type of implant and bearing, pain and functional outcome as well as complications and survival.

Recent advances in THA technology allow for successful outcomes in these patients. Our review suggests excellent benefits for pain relief and good functional outcome might be expected with a modest risk of complication.

Cite this article: Bone Joint J 2018;100-B(1 Supple A):17–21.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1489 - 1496
1 Nov 2016
Konan S Sandiford N Unno F Masri BS Garbuz DS Duncan CP

Fractures around total knee arthroplasties pose a significant surgical challenge. Most can be managed with osteosynthesis and salvage of the replacement. The techniques of fixation of these fractures and revision surgery have evolved and so has the assessment of outcome. This specialty update summarises the current evidence for the classification, methods of fixation, revision surgery and outcomes of the management of periprosthetic fractures associated with total knee arthroplasty.

Cite this article: Bone Joint J 2016;98-B:1489–96.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 767 - 771
1 Jun 2016
Konan S Duncan CP Masri BA Garbuz DS

Aims

Reconstruction of the acetabulum after failed total hip arthroplasty (THA) can be a surgical challenge in the presence of severe bone loss. We report the long-term survival of a porous tantalum revision acetabular component, its radiological appearance and quality of life outcomes.

Patients and Methods

We reviewed the results of 46 patients who had undergone revision of a failed acetabular component with a Paprosky II or III bone defect and reconstruction with a hemispherical, tantalum acetabular component, supplementary screws and a cemented polyethylene liner.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 187 - 193
1 Feb 2016
Lash NJ Whitehouse MR Greidanus NV Garbuz DS Masri BA Duncan CP

Aims

We present a case series of ten metal-on-polyethylene total hip arthroplasties (MoP THAs) with delayed dislocation associated with unrecognised adverse local tissue reaction due to corrosion at the trunnion and pseudotumour formation.

Methods

The diagnosis was not suspected in nine of the ten patients (six female/four male; mean age 66 years), despite treatment in a specialist unit (mean time from index surgery to revision was 58 months, 36 to 84). It was identified at revision surgery and subsequently confirmed by histological examination of resected tissue. Pre-operative assessment and culture results ruled out infection. A variety of treatment strategies were used, including resection of the pseudotumour and efforts to avoid recurrent dislocation.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 50 - 53
1 Jan 2016
Konan S Garbuz DS Masri BA Duncan CP

Tapered fluted titanium stems are increasingly used for femoral revision arthroplasty. They are available in modular and non-modular forms. Modularity has advantages when the bone loss is severe, the proximal femur is mis shapen or the surgeon is unfamiliar with the implant, but it introduces the risk of fracture of the stem at the junction between it and the proximal body segment. For that reason, and while awaiting intermediate-term results of more recently introduced designs of this junction, non-modularity has attracted attention, at least for straightforward revision cases.

We review the risks and causes of fracture of tapered titanium modular revision stems and present an argument in favour of the more selective use of modular designs.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):50–3.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 27 - 30
1 Jan 2016
Whitehouse MR Parry MC Konan S Duncan CP

Periprosthetic joint infection (PJI) complicates between 0.5% and 1.2% primary total hip arthroplasties (THAs) and may have devastating consequences. The traditional assessment of patients suffering from PJI has involved the serological study of inflammatory markers and microbiological analysis of samples obtained from the joint space. Treatment has involved debridement and revision arthroplasty performed in either one or two stages.

We present an update on the burden of PJI, strategies for its diagnosis and treatment, the challenge of resistant organisms and the need for definitive evidence to guide the treatment of PJI after THA.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):27–30.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1024 - 1030
1 Aug 2015
Whitehouse MR Endo M Zachara S Nielsen TO Greidanus NV Masri BA Garbuz DS Duncan CP

Adverse reaction to wear and corrosion debris is a cause for concern in total hip arthroplasty (THA). Modular junctions are a potential source of such wear products and are associated with secondary pseudotumour formation.

We present a consecutive series of 17 patients treated at our unit for this complication following metal-on-highly cross-linked polyethylene (MoP) THA. We emphasise the risk of misdiagnosis as infection, and present the aggregate laboratory results and pathological findings in this series.

The clinical presentation was pain, swelling or instability. Solid, cystic and mixed soft-tissue lesions were noted on imaging and confirmed intra-operatively. Corrosion at the head–neck junction was noted in all cases. No bacteria were isolated on multiple pre- and intra-operative samples yet the mean erythrocyte sedimentation rate was 49 (9 to 100) and C-reactive protein 32 (0.6 to 106) and stromal polymorphonuclear cell counts were noted in nine cases.

Adverse soft–tissue reactions can occur in MoP THA owing to corrosion products released from the head–neck junction. The diagnosis should be carefully considered when investigating pain after THA. This may avoid the misdiagnosis of periprosthetic infection with an unidentified organism and mitigate the unnecessary management of these cases with complete single- or two-stage exchange.

Cite this article: Bone Joint J 2015;97-B:1024–1030.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1669 - 1673
1 Dec 2014
Van der Merwe JM Haddad FS Duncan CP

The Unified Classification System (UCS) was introduced because of a growing need to have a standardised universal classification system of periprosthetic fractures. It combines and simplifies many existing classification systems, and can be applied to any fracture around any partial or total joint replacement occurring during or after operation. Our goal was to assess the inter- and intra-observer reliability of the UCS in association with knee replacement when classifying fractures affecting one or more of the femur, tibia or patella.

We used an international panel of ten orthopaedic surgeons with subspecialty fellowship training and expertise in adult hip and knee reconstruction (‘experts’) and ten residents of orthopaedic surgery in the last two years of training (‘pre-experts’). They each received 15 radiographs for evaluation. After six weeks they evaluated the same radiographs again but in a different order.

The reliability was assessed using the Kappa and weighted Kappa values.

The Kappa values for inter-observer reliability for the experts and the pre-experts were 0.741 (95% confidence interval (CI) 0.707 to 0.774) and 0.765 (95% CI 0.733 to 0.797), respectively. The weighted Kappa values for intra-observer reliability for the experts and pre-experts were 0.898 (95% CI 0.846 to 0.950) and 0.878 (95% CI 0.815 to 0.942) respectively.

The UCS has substantial inter-observer reliability and ‘near perfect’ intra-observer reliability when used for periprosthetic fractures in association with knee replacement in the hands of experienced and inexperienced users.

Cite this article: Bone Joint J 2014;96-B:1669–73.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 56 - 59
1 Nov 2014
Konan S Garbuz DS Masri BA Duncan CP

Non-modular tapered fluted, titanium stems are available for use in femoral revision. The combination of taper and flutes on the stem provides axial and rotational stability, respectively. The material and surface properties of the stem promotes bone on-growth. If the surgeon is confident and reasonably experienced in the surgical use of this sort of design and the case is relatively straightforward, a non-modular design is effective. It also potentially reduces implant inventory, and circumvents the potential problems of taper junction corrosion and fatigue fracture. There are reports of excellent survival, good clinical and functional results and evidence of subsequent increase in proximal bone stock.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):56–9.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1472 - 1477
1 Nov 2014
Vioreanu MH Parry MC Haddad FS Duncan CP

The Unified Classification System (UCS) emphasises the key principles in the assessment and management of peri-prosthetic fractures complicating partial or total joint replacement.

We tested the inter- and intra-observer agreement for the UCS as applied to the pelvis and femur using 20 examples of peri-prosthetic fracture in 17 patients. Each subtype of the UCS was represented by at least one case. Specialist orthopaedic surgeons (experts) and orthopaedic residents (pre-experts) assessed reliability on two separate occasions.

For the pelvis, the UCS showed inter-observer agreement of 0.837 (95% confidence intervals (CI) 0.798 to 0.876) for the experts and 0.728 (95% CI 0.689 to 0.767) for the pre-experts. The intra-observer agreement for the experts was 0.861 (95% CI 0.760 to 0.963) and 0.803 (95% 0.688 to 0.918) for the pre-experts. For the femur, the UCS showed an inter-observer kappa value of 0.805 (95% CI 0.765 to 0.845) for the experts and a value of 0.732 (95% CI 0.690 to 0.773) for the pre-experts. The intra-observer agreement was 0.920 (95% CI 0.867 to 0.973) for the experts, and 0.772 (95% CI 0.652 to 0.892) for the pre-experts. This corresponds to a substantial and ‘almost perfect’ inter- and intra-observer agreement for the UCS for peri-prosthetic fractures of the pelvis and femur.

We hope that unifying the terminology of these injuries will assist in their assessment, treatment and outcome.

Cite this article: Bone Joint J 2014;96-B:1472–7.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 60 - 65
1 Nov 2014
Parry MC Duncan CP

Advances in the treatment of periprosthetic joint infections of the hip have once more pushed prosthesis preserving techniques into the limelight. At the same time, the common infecting organisms are evolving to become more resistant to conventional antimicrobial agents. Whilst the epidemiology of resistant staphylococci is changing, a number of recent reports have advocated the use of irrigation and debridement and one-stage revision for the treatment of periprosthetic joint infections due to resistant organisms. This review presents the available evidence for the treatment of periprosthetic joint infections of the hip, concentrating in particular on methicillin resistant staphylococci.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):60–5.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 711 - 712
1 Jun 2014
Duncan CP


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 713 - 716
1 Jun 2014
Duncan CP Haddad FS

Periprosthetic fractures are an increasingly common complication following joint replacement. The principles which underpin their evaluation and treatment are common across the musculoskeletal system. The Unified Classification System proposes a rational approach to treatment, regardless of the bone that is broken or the joint involved.

Cite this article: Bone Joint J 2014;96-B:713–16.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 17 - 20
1 Nov 2013
Munro JT Masri BA Garbuz DS Duncan CP

Tapered, fluted, modular, titanium stems are increasingly popular in the operative management of Vancouver B2 and selected B3 peri-prosthetic femoral fractures. We have reviewed the results at our institution looking at stem survival and clinical outcomes and compared this with reported outcomes in the literature. Stem survival at a mean of 54 months was 96% in our series and 97% for combined published cases. Review of radiology showed maintenance or improvement of bone stock in 89% of cases with high rates of femoral union. Favourable clinical outcome scores have reported by several authors. No difference in survival or clinical scores was observed between B2 and B3 fractures. Tapered stems are a useful option in revision for femoral fracture across the spectrum of femoral bone deficiency.

Cite this article: Bone Joint J 2013;95-B, Supple A:17–20.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 114 - 119
1 Nov 2013
Whitehouse MR Duncan CP

Hip arthrodesis remains a viable surgical technique in well selected patients, typically the young manual labourer with isolated unilateral hip disease. Despite this, its popularity with patients and surgeons has decreased due to the evolution of hip replacement, and is seldom chosen by young adult patients today. The surgeon is more likely to encounter a patient who requests conversion to total hip replacement (THR). The most common indications are a painful pseudarthrosis, back pain, ipsilateral knee pain or contralateral hip pain. Occasionally the patient will request conversion because of difficulty with activities of daily living, body image and perceived cosmesis. The technique of conversion and a discussion of the results are presented.

Cite this article: Bone Joint J 2013;95-B, Supple A:114–19.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 58 - 60
1 Nov 2012
Munro JT Garbuz DS Masri BA Duncan CP

Tapered, fluted, modular, titanium stems have a long history in Europe and are increasing in popularity in North America. We have reviewed the results at our institution looking at stem survival and clinical outcomes. Radiological outcomes and quality of life assessments have been performed and compared to cylindrical non-modular cobalt chromium stems. Survival at five years was 94%. This fell to 85% at ten years due to stem breakage with older designs. Review of radiology showed maintenance or improvement of bone stock in 87% of cases. Outcome scores were superior in tapered stems despite worse pre-operative femoral deficiency. Tapered stems have proved to be a useful alternative in revision total hip arthroplasty across the spectrum of femoral bone deficiency.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 123 - 125
1 Nov 2012
Munro JT Garbuz DS Masri BA Duncan CP

Antibiotic impregnated articulating spacers are used in two-stage revision total knee arthroplasty to deliver local antibiotic therapy while preserving function. We have observed infection control in greater than 95% of cases with functional outcomes approaching those seen in revision for aseptic loosening. Higher failure has been observed with methicillin resistant organisms.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 109 - 109
1 Sep 2012
Masri BA Williams DH Greidanus NV Duncan CP Garbuz DS
Full Access

Purpose

There is a postulated association between increased serum metal ions and pseudotumour formation in patients with metal-on-metal hip replacements. The primary aim of this study was to assess the prevalence of pseudotumour in 31 asymptomatic patients with a large femoral head (LFH) metal-on-metal hip implant. This was compared to the prevalence of pseudotumour in 20 matched asymptomatic patients with a hip resurfacing (HRA) and 24 matched asymptomatic patients with a standard metal-on-polyethylene (MOP) total hip. A secondary objective was to assess possible correlation between increased serum metal ions and pseudotumour formation

Method

Ultrasound examination of the three groups was performed at a minimum follow up of two years. Serum metal ions were measured in the metal-on-metal LFH and HRA groups at a minimum of two years.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 106 - 106
1 Sep 2012
Masri BA Garbuz DS Duncan CP VGreidanus N Bohm E Valle CJD Gross AE
Full Access

Purpose

Dislocation after revision total hip is a common complication. The purpose of this study was to assess whether a large femoral head (36/40mm) would result in a decreased dislocation rate compared to a standard head (32mm).

Method

A randomized clinical trial was undertaken to assess the effect of large femoral heads on dislocation after revision total hip. Patients undergoing revision hip arthroplasty at seven centers were randomized to 32mm head or 36/40mm head. Patients were stratified according to surgeon. Primary endpoint was dislocation. Rates were compared with Fishers exact test. Secondary outcome measures were quality of life: WOMAC, SF-36 and satisfaction. One hundred eighty four patients were randomized: 92 in the 32mm head group and 92 in the large head group. Baseline demographics were similar in the two groups. Patients were followed from two to five years postoperatively


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 113 - 113
1 Sep 2012
Greidanus NV Garbuz DS Masri BA Duncan CP Gross AE Tanzer M Aziz A Anis A
Full Access

Purpose

The purpose of this study was to compare and evaluate the cost-effectiveness of the MIS Anterolateral Approach to that of the MIS Posterolateral and MIS Direct Lateral Approach.

Method

A prospective randomized control trial was designed and conducted to compare the MIS Anterolateral Approach to that of the MIS Posterolateral and MIS Direct Lateral Approach. Contemporary methods for economic evaluation were used to ascertain direct and indirect costs (in Canadian dollars) along with clinical effectiveness outcomes (SF6D and Pat5D utility measures). University and hospital ethics was obtained and patients were recruited and consented to participate in the RCT resulting in the assignment of 130 patients MIS hip arthroplasty procedures. Baseline patient demographics, comorbidity, quality of life, and utility were obtained for all patients. In-hospital costing data was obtained including operating room and patient room costs as well as medication, rehab and complications. Post-discharge costs were calculated from direct and indirect costs of medication, rehab, medical costs and complications until one year post-operatively. Clinical effectiveness measures were administered at intervals until one year post-operatively.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 567 - 567
1 Nov 2011
Greidanus NV Garbuz D Masri BA Gross A Tanzer M Duncan CP
Full Access

Purpose: The purpose of this study was to evaluate the clinical effectiveness and outcomes of the ‘abductor sparing’ MIS Anterolateral approach (MIS Watson Jones/G3) in comparison to the MIS Direct Lateral and MIS Posterolateral approaches in primary total hip arthroplasty.

Method: A multicentre, prospective, randomized controlled trial was designed to evaluate for the superiority of the new MIS Anterolateral approach (MIS Watson Jones/ G3). The sample size calculation was performed for alpha .05, power .90, to evaluate for effect size 0.5 in WOMAC using repeated measures analyses with baseline WOMAC as covariate. A total of 156 patients consented to participate in the trial and patients were assigned to MIS Antero-lateral approach or alternate MIS approach (MIS Direct Lateral or MIS Posterolateral). Patients were subjected to standardized anaesthetic and perioperative management protocols and were evaluated at standardized intervals to evaluate endpoints of early recovery (3 months) as well as endpoints of 12 and 24 months respectively. The primary outcome of interest was WOMAC, however secondary outcomes included SF-36, as well as parameters of health resource utilization and complications. Univariate and multivariate analyses were perfomed.

Results: Patient groups were found to be similar at baseline with regards to demographics and baseline quality of life outcomes (p> .05). Multivariate and repeated measures analyses demonstrated no superiority of the MIS Anterolateral approach on outcomes of WOMAC and other quality of life measures in comparison to MIS Direct Lateral and MIS Posterolateral approaches (p> .05). Health care resource utlization was also similar with length of stay, blood transfusion requirements and complications (p> .05).

Conclusion: Our multicentre, prospective, randomized clinical trial demonstrates that the MIS Anterolateral approach is not superior to alternate MIS surgical approaches when evaluating outcomes of quality of life, complications, and health resource utilization. Surgeons should consider these outcomes, complications, and other relevant advantages and disadvantages of select surgical approaches when deciding on a technique for use in their orthopaedic practice.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 250 - 250
1 Jul 2011
Leung F Duncan CP Burt H Jackson J
Full Access

Purpose: This study investigates the synergistic use of fusidic acid with vancomycin, and linezolid in poly-methylmethacrylate (PMMA) cement for the treatment of orthopedic MRSA and MRSE infections. Alone, Vancomycin is typically eluted in limited quantities from cement. The purpose of this study was to

combine FA and Vancomycin, and Linezolid alone in PMMA cement and characterize antibiotic elution, and

to improve drug release using polyethylene glycol (PEG) and NaCl in PMMA cement.

Method: Standardized 1g pellets of Palacos cement were manufactured containing Vancomycin and FA or Linezolid at increasing concentrations in three batches: without additive, with increasing concentrations of PEG, and with increasing concentrations of NaCl. The pellets were incubated in phosphate buffered saline and sampled at regular intervals. Drug analysis was performed with high pressure liquid chromatograpy.

Results: Total drug release at 2.5% loading of Vancomycin alone was 0.84% and of FA was 2.35%. Linezolid showed comparable release profiles. Vancomycin and FA combined yeilded Vancomycin release of 6.2% and FA of 8.4%. The addition of 30% PEG increased release of Vancomycin and Fusidic Acid by six-fold. The addition of 18% NaCl increased total Vancomycin release by 11-fold but had no effect on FA release.

Conclusion: Linezolid, Vancomycin and FA can be combined in PMMA and have favorable release profiles. The addition of PEG and NaCl dramatically increases the release of antibiotics, with the exception of FA and NaCl. These strategies may be useful in the management of MRSA/MRSE infections.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 4 - 4
1 Mar 2010
Greidanus NV Siegmeth A Rahman W Garbuz D Masri BA Duncan CP
Full Access

Purpose: The purpose of this study was to prospectively evaluate a consecutive series of patients receiving metal on metal hip resurfacing arthroplasty with regards to outcomes and complications at minimum of 2 years follow-up.

Method: A prospective evaluation of all patients receiving hip resurfacing was performed including baseline evaluation (demographics, WOMAC, SF12, Oxford Hip Score) and minimum 2 year follow-up assessment (WOMAC, SF12, Oxford Hip Score, UCLA activity score, Patient Satisfaction, Complications). No patients were lost to follow-up.

Results: 143 hips in 127 patients received metal-on-metal hip resurfacing arthroplasty. The mean age was 52 years and the primary diagnosis was osteoarthritis or avascular necrosis, Significant improvements were noticed across all baseline quality of life instruments (p< .05) with final mean WOMAC and Oxford Scores 95 (normalized 0–100). Final post-op satisfaction was mean 95 out of 100. Two patient sustained post-operative femoral neck fractures and required revision. An additional two patients required revision for ongoing hip pain. One patient sustained a sciatic nerve palsty and one additional patient required acetabular component repositioning on the same day as the index procedure. Revision procedures involved conversion of resurfacing femoral component to cementless total hip stem with large diameter metal head and preservation of acetabular component. Acetabular component survivorship is 99% and femoral component survivorship is 97% at 2 year follow-up.

Conclusion: Our short to midterm data, from an independant center, suggests excellent improvement in quality of life with high levels of patient satisfaction and postop acitivity level. Our comprehensive post-operative quality of life assessment demonstrates restoration of the hip to rival that of the normal non-arthritic hip joint. Complications unique to resurfacing arthroplasty occur and were not predictable based on pre-operative or intra-operative patient-specific features.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 30 - 30
1 Mar 2010
Kim W Garbuz DS Hu Y Duan K Masri BA Rizhi W Duncan CP
Full Access

Purpose: Porous tantalum has been shown to be very effective in achieving bone ingrowth. However, in some circumstances, bone quality or quantity is insufficient to allow adequate bone ingrowth. We hypothesized that the addition of alendronate to porous tantalum would enhance the ability of porous tantalum to achieve bone ingrowth in these challenging situations, such as when a gap exists between the implant and bone. We evaluated the effect of alendronate coated porous tantalum on new bone formation in an animal model incorporating a gap between implant and bone.

Method: Thirty-six cylindrical porous tantalum implants were bilaterally implanted into the distal femur of 18 rabbits for 4 weeks. There were 3 groups of implants inserted; a control group of porous tantalum with no coatings, porous tantalum with micro-porous calcium phosphate coating, and porous tantalum coated with micro-porous calcium phosphate and alendronate. Subcutaneous fluorescent labeling was used to track new bone formation. Bone formation was analyzed by backscattered electron microscopy and fluorescent microscopy on undecalcified samples.

Results: The relative increase in mean volume of gap filling, bone ingrowth and total bone formation was 143% (p< 0.001), 259% (p< 0.001) and 193% (p< 0.001) respectively in the alendronate coated porous tantalum compared with the uncoated porous tantalum controls. The relative increase in the percentage of new bone-implant contact length was increased by 804% on average in the alendronate coated porous tantalum compared with the uncoated tantalum controls.

Conclusion: This study demonstrated the significant enhancement of bone-implant gap filling and bone ingrowth which can be achieved by coating porous tantalum with alendronate. It is proposed that, when faced with the clinical problem of revision joint replacement in the face of bone loss (at the hip, knee or elsewhere), the addition of an alendronate-delivery surface coating would enhance biological fixation of the implant and promote the healing of bone defects.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1431 - 1437
1 Nov 2009
Biring GS Kostamo T Garbuz DS Masri BA Duncan CP

We report the outcome at ten to 15 years of two-stage revision for hip infection in 99 patients using the Prostalac articulated hip spacer system.

All the patients were contacted to determine their current functional and infection status using the Oxford-12, Short form-12, and Western Ontario and McMaster University Osteoarthritis Index questionnaires. A total of 11 of the 99 patients had a further infection, of whom seven responded to repeat surgery with no further sequelae. The mean interval between the stages was five months (1 to 36). We were able to review 48 living patients, with a mean age of 72 years (46 to 86), 34 (71%) of whom provided health-related quality-of-life outcome scores.

The mean follow-up was 12 years (10 to 15). The long-term success rate was 89% and with additional surgery this rose to 96%. The mean global Western Ontario and McMaster University Osteoarthritis Index score was 80.6 (sd 18.3). The mean Oxford-12 score was 74.0 (sd 22.3), and the mean Short form-12 score was 53.1 (sd 9.4) (mental) and 33.5 (sd 13.5) (physical). The mean satisfaction score was 90.5 (sd 15.3).

Two-stage revision for hip infection using a Prostalac interim spacer offers a predictable and lasting solution for patients with this difficult problem.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 541 - 541
1 Aug 2008
Kim WY Hu Y Duan K Wang R Garbuz DS Masri BA Duncan CP
Full Access

Introduction: Achieving durable implant–host bone fixation is the major challenge in uncemented revision hip arthroplasty when significant bone stock deficiencies are encountered. The purpose of this study was 1) to develop an experimental model which would simulate the clinical revision hip scenario and 2) determine the effects of alendronate coating on porous tantalum on gap filling and bone ingrowth in the experimental model.

Methods: Thirty-six porous tantalum plugs were implanted into the distal femur, bilaterally of 18 rabbits for four weeks. There were 3 groups of plugs inserted; control groups of porous tantalum plugs (Ta) with no coating, a 2nd control group of porous tantalum plugs with micro-porous calcium phosphate coating, (Ta-CaP) and porous tantalum plugs coated with alendronate (Ta-CaP-ALN). Subcutaneous fluorochrome labelling was used to track new bone formation. Bone formation was analysed by backscattered electron microscopy and fluorescence microscopy on undecalcified histological sections.

Results: The relative increase in mean volume of gap filling, bone ingrowth and total bone formation was 124 %, 232 % and 170 % respectively in Ta-CaP-ALN compared with the uncoated porous tantalum (Ta) controls, which was statistically significant. The contact length of new bone formation on porous tantalum implants in Ta-CaP-ALN was increased by 700% (8-fold) on average compared with the uncoated porous tantalum (Ta) controls.

Discussion: Alendronate coated porous tantalum significantly modulated implant bioactivity compared with controls. This study has demonstrated the significant enhancement of bone-implant gap filling and bone ingrowth, which can be achieved by coating porous tantalum with alendronate. It is proposed that, when faced with the clinical problem of revision joint replacement in the face of bone loss, the addition of alendronate as a surface coating would enhance biological fixation of the implant and promote the healing of bone defects.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 535 - 535
1 Aug 2008
Kim WY Greidanus NV Masri BA Duncan CP Garbuz DS
Full Access

Revision of a failed acetabular reconstruction in total hip arthroplasty (THA) can be challenging when associated with significant bone loss. In cementless revision THA, achieving initial implant stability and maximising host bone contact is key to the success of reconstruction. Porous tantalum acetabular shells may represent an improvement from conventional porous coated uncemented cups in revision acetabular reconstruction associated with severe acetabular bone defects.

Methods: We reviewed the clinical and radiographic results of 46 acetabular revisions with Paprosky 2 and 3 acetabular bone defects done with a hemispheric, tantalum acetabular shell (Trabecular Metal Revision Shell, Zimmer, Warsaw, USA) and multiple supplementary screws for fixation.

Results: At a mean follow-up of 40 (24–51) months, one acetabular shell had been revised in a patient with a Paprosky 3B defect. Two liner revisions were performed for recurrent instability, without porous tantalum shell revision. The clinical outcome showed significant postoperative improvement in all measured sub-scales, compared with baseline pre-operative scores (mean improvement in Oxford Hip Score of 40.0, p < 0.001, in WOMAC of 36.7, p < 0.001, Physical component SF-12 of 12.3, p =0.0003, mental component of SF-12 of 6.8, p = 0.006). Radiographic evidence of osseointegration using validated criteria (Moore’s criteria) was demonstrated in 39 of the 40 hips available for radiographic analysis at a mean of 30.9 months, by two independent observers. Of the remaining six hips, five hips were lost to follow-up and one radiograph demonstrated failure of the hip reconstruction secondary to loss of fixation and superior migration of the component.

Discussion: Cementless acetabular revision with the porous tantalum acetabular shell demonstrated excellent early clinical and radiographic results in a series of complex revision acetabular reconstruction associated with severe bone defects. The evidence of radiographic osseointegration suggests that outcome should remain favourable, however, further longer-term evaluation is warranted.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 534 - 534
1 Aug 2008
Biring GS Kostamo T Masri BA Garbuz DS Duncan CP
Full Access

Introduction: Deep infection in total hip replacement can be devastating. We report the outcomes 10–15 years after two stage revision for hip infection in 103 patients using the PROSTALAC (prosthesis of antibiotic-loaded acrylic cement) hip.

Methods: All patients or their next of kin were contacted to determine their current functional status and whether they had required repeat surgery or had recurrent infection. The Oxford-12, SF-12, and WOMAC questionnaires were administered. A comprehensive chart review was undertaken to review the infective organisms, surgery, approach, complications, and need for further revision surgery.

Results: 11 patients had re-infection, 7 of whom responded to repeat surgery with no further sequelae. Two patients required resection arthroplasty, one patient underwent hip disarticulation after eventual failure of treatment and bone loss, and one immuno-compromised patient developed osteomyelitis and was subsequently lost to follow-up. Long-term success rate for two stage-revision is thus 89%, or 96% with additional surgery. Since then, 3 patients required revisions for aseptic loosening, 1 for recurrent dislocation. We were able to follow up 45 patients, 75 % of whom provided health-related quality of life outcome scores. 39 patients were deceased, with their outcome confirmed via their last follow-up or with family members, for a total follow-up rate of 85 %. 15 patients were lost to follow-up, but did not undergo further surgery or have reinfections treated at our centre.

Discussion: Two-stage revision for hip infection, which includes an interim prosthesis of antibiotic loaded cement, offers a predictable and lasting solution for patients with this difficult problem.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 535 - 535
1 Aug 2008
Biring GS Masri BA Greidanus NV Duncan CP Garbuz DS
Full Access

Introduction: The aims of this study were to

determine predictors of pain, function and activity level 1–2 years after revision hip arthroplasty and

define quality of life outcomes after revision total hip replacement.

Methods: A prospective cohort of 222 patients who underwent revision hip arthroplasty were evaluated. Predictive models were developed and proportional odds regression analyses were performed to identify factors that predict quality of life outcomes at 1 and 2 years post surgery. The dependent outcome variables were WOMAC function, pain and UCLA activity. The independent variables included patient demographic, surgery specific and objective parameters including baseline Western Ontario McMaster Universities (WOMAC) osteoarthritis index, and the Short Form-12 mental component. The Loess method was used to plot the change of WOMAC and SF-12 scores over time.

Results: There was a significant improvement (p< 0.001) in all patient quality of life scores from baseline with results plateauing at 1 year. UCLA activity remained static between 1 and 2 years. In the predictive model, higher baseline WOMAC function (p < 0.001), age between 60–70 (p< 0.037), male gender (0.017), lower Charnley class (p < 0.001) and diagnosis of aseptic loosening (p < 0.003) were significant predictors of improved function.

When considering WOMAC pain as an outcome variable, factors predictive of improving category outcome included baseline WOMAC function (p= 0.001), age between 60–70 (p< 0.004), male gender (p= 0.005), lower Charnley class (p< 0.001) and no previous revisions (p < 0.023). Baseline WOMAC pain did not predict final pain outcome. Baseline WOMAC function (p=0.001), the indication for the operation (p=0.007), and the operating surgeon were significant predictors of UCLA activity at follow up. Peri or post-operative complications were not an adverse predictor of physical function, pain or activity.

Conclusions: Predictors of quality of life outcomes after revision hip replacement-showed that although some patient specific and surgical specific variables were important, age, gender, Charnley class and baseline WOMAC function had the most robust associations with outcomes.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 546 - 546
1 Aug 2008
Biring GS Masri BA Garbuz DS Greidanus NV Duncan CP
Full Access

Introduction: This single incision, anterolateral intermuscular approach (AL-IM) utilizes the interval between gluteus medius and tensor fascia lata. The aims of the study were to compare the quality of life, satisfaction and complications of this approach with two of the most commonly used limited incision transmuscular (TM) approaches, namely the mini-posterior (P-TM) and the mini-direct lateral (L-TM).

Methods: 199 patients receiving MIS THA surgical procedures were evaluated prospectively (63 AL-IM, 68 P-TM and 68 L-TM). The outcome variables were WOMAC function, pain, stiffness, SF-12 (physical & mental), Oxford-12, satisfaction and radiological outcome. Parametric and non-parametric analyses were performed.

Results: There were no significant differences between groups in baseline characteristics including age, sex, BMI, co-morbidity, or pre-op WOMAC, SF-12, Oxford-12 (p> .05). However, the AL-IM group was associated with superior outcomes (p< .05) in WOMAC function, WOMAC pain, global WOMAC, Oxford-12 and SF-12 physical component.

Conclusion: In the short term the AL-IM approach provides significant improvements in quality of life scores over other limited incision approaches. It provides minimal soft tissue disruption and maintains the abductor musculature and posterior soft tissue envelope, with similar complications and radiological outcomes.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1446 - 1451
1 Nov 2007
Biring GS Masri BA Greidanus NV Duncan CP Garbuz DS

A prospective cohort of 222 patients who underwent revision hip replacement between April 2001 and March 2004 was evaluated to determine predictors of function, pain and activity level between one and two years post-operatively, and to define quality of life outcomes using validated patient reported outcome tools. Predictive models were developed and proportional odds regression analyses were performed to identify factors that predict quality of life outcomes at one and two years post-operatively. The dependent outcome variables were the Western Ontario and McMaster Osteoarthritis Index (WOMAC) function and pain scores, and University of California Los Angeles activity scores. The independent variables included patient demographics, operative factors, and objective quality of life parameters, including pre-operative WOMAC, and the Short Form-12 mental component score.

There was a significant improvement (t-test, p < 0.001) in all patient quality of life scores. In the predictive model, factors predictive of improved function (original regression analyses, p < 0.05) included a higher pre-operative WOMAC function score (p < 0.001), age between 60 and 70 years (p < 0.037), male gender (p = 0.017), lower Charnley class (p < 0.001) and aseptic loosening being the indication for revision (p < 0.003). Using the WOMAC pain score as an outcome variable, factors predictive of improvement included the pre-operative WOMAC function score (p = 0.001), age between 60 and 70 years (p = 0.004), male gender (p = 0.005), lower Charnley class (p = 0.001) and no previous revision procedure (p = 0.023). The pre-operative WOMAC function score (p = 0.001), the indication for the operation (p = 0.007), and the operating surgeon (p = 0.008) were significant predictors of the activity assessment at follow-up.

Predictors of quality of life outcomes after revision hip replacement were established. Although some patient-specific and surgery-specific variables were important, age, gender, Charnley class and pre-operative WOMAC function score had the most robust associations with outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 149 - 155
1 Feb 2006
Toms AD Davidson D Masri BA Duncan CP


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 771 - 776
1 Jul 2004
Frei H Mitchell P Masri BA Duncan CP Oxland TR

We studied various aspects of graft impaction and penetration of cement in an experimental model. Cancellous bone was removed proximally and local diaphyseal lytic defects were simulated in six human cadaver femora. After impaction grafting the specimens were sectioned and prepared for histomorphometric analysis.

The porosity of the graft was lowest in Gruen zone 4 (52%) and highest in Gruen zone 1 (76%). At the levels of Gruen zones 6 and 2 the entire cross-section was almost filled with cement. Cement sometimes reached the endosteal surface in other Gruen zones. The mean peak impaction forces exerted with the impactors were negatively correlated with the porosity of the graft.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 949 - 952
1 Sep 2003
Mitchell PA Masri BA Garbuz DS Greidanus NV Wilson D Duncan CP

Removal of well-fixed, cementless, acetabular components during revision arthroplasty remains a challenging problem. Further damage to host bone may limit options for reconstruction and compromise the long-term result of the revision operation. We report the results of 31 hips with well-fixed, cementless sockets which were removed using a new cup extraction system. In all hips the socket was removed without difficulty and with minimal further bone loss.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 830 - 836
1 Aug 2000
Haddad FS Garbuz DS Masri BA Duncan CP

There are few medium- and long-term data on the outcome of the use of proximal femoral structural allografts in revision hip arthroplasty. This is a study of a consecutive series of 40 proximal femoral allografts performed for failed total hip replacements using the same technique with a minimum follow-up of five years (mean 8.8 years; range 5 to 11.5 years). In all cases the stem was cemented into both the allograft and the host femur. The proximal femur of the host was resected in 37 cases.

There were four early revisions (10%), two for infection, one for nonunion of the allograft-host junction, and one for allograft resorption noted at the time of revision of a failed acetabular reconstruction. Junctional nonunion was seen in three patients (8%), two of whom were managed successfully by bone grafting, and bone grafting and plating respectively. Instability was observed in four (10%). Trochanteric nonunion was seen in 18 patients (46%) and trochanteric escape in ten of these (27%). The mean Harris hip score improved from 39 to 79. Severe resorption involving the full thickness of the allograft was seen in seven patients (17.5%). This progressed rapidly and silently, but has yet to cause failure of any of the reconstructions.

Profound resorption of the allograft may be related to a combination of factors, including a slow form of immune rejection, stress shielding and resorption due to mechanical disuse with solid cemented distal fixation, and the absence of any masking or protective effect which may be provided by the retention of the bivalved host bone as a vascularised onlay autograft. Although continued surveillance is warranted, the very good medium-term clinical results justify the continued use of structural allografts for failed total hip replacements with severe loss of proximal femoral bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 807 - 812
1 Aug 2000
Haddad FS Masri BA Campbell D McGraw RW Beauchamp CP Duncan CP

The PROSTALAC functional spacer is made of antibiotic-loaded acrylic cement but has a small metal-on-polythene articular surface. We have used it as an interim spacer in two-stage exchange arthroplasty for infected total knee replacement. PROSTALAC allows continuous rehabilitation between stages as it maintains good alignment and stability of the knee and a reasonable range of movement. It also helps to maintain the soft-tissue planes, which facilitates the second-stage procedure.

We reviewed 45 consecutive patients, treated over a period of nine years. The mean follow-up was for 48 months (20 to 112). At final review, there was no evidence of infection in 41 patients (91%); only one had a recurrent infection with the same organism. There was improvement in the Hospital for Special Surgery knee score between stages and at final review. The range of movement was maintained between stages. Complications were primarily related to the extensor mechanism and stability of the knee between stages. Both of these problems decreased with refinement of the design of the implant.

The rate of cure of the infection in our patients was similar to that using other methods. Movement of the knee does not appear to hinder control of infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 526 - 531
1 May 2000
Haddad FS Garbuz DS Duncan CP Janzen DL Munk PL

We have previously described a simple and reproducible three-dimensional technique of CT for the measurement of the cover of the femoral head in acetabular dysplasia in adults. We now describe the application of this technique in ten patients with symptomatic dysplasia to assess the degree and direction of dysplasia and to measure the cover obtained at acetabular osteotomy.

The indices obtained gave a useful indication of the degree and direction of the dysplasia and confirmed which components had been used most efficiently to achieve cover. The information is easily presented in graphical form and gives a clearer indication of the cover obtained than the indices derived from plain radiographs.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 485 - 487
1 May 1999
Kerry RM Masri BA Beauchamp CP Duncan CP

We describe a U-shaped approach to the distal femur which, having divided the extensor mechanism and elevated the entire quadriceps muscle, gives excellent exposure and allows a number of reconstructive options. It was used in 14 patients, 13 of whom were followed up for a mean of 3.5 years (1 to 11). There was no case of flap necrosis, and complications related to the reconstruction were acceptable.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 908 - 913
1 Nov 1997
Masterson EL Masri BA Duncan CP Rosenberg A Cabanela M Gross M

An analysis of the cement mantle obtained with the Exeter impaction allografting system at one centre showed that it was either deficient or absent in almost 47% of Gruen zones. We therefore examined the mantle obtained using this system at another hospital and compared the results with those from the CPT and Harris Precoat Systems at other centres.

The surgical indications for the procedure and the patient details were broadly similar in all four hospitals. There was some variation in the frequency of use of cortical strut allografts, cerclage wires and wire mesh to supplement the impaction allograft. Analysis of the cement mantles showed that when uncertain Gruen zones were excluded, the incidence of zones with areas of absence or deficiency of the cement was 47% and 50%, respectively, for the two centres using the Exeter system, 21% for the CPT system and 18% for the Harris Precoat system.

We measured the difference in size between the proximal allograft impactors and the definitive prosthesis for each system. The Exeter system impactors are shorter than the definitive prosthesis and taper sharply so that the cavity created is inadequate, especially distally. The CPT proximal impactors are considerably longer than the definitive prosthesis and are designed to give a mantle of approximately 2 mm medially and laterally and 1.5 mm anteriorly and posteriorly. The Harris Precoat proximal impactors allow for a mantle with a circumference of 0.75 mm in the smaller sizes and 1 mm in the larger.

Many reports link the longevity of a cemented implant to the adequacy of the cement mantle. For this reason, femoral impaction systems require careful design to achieve a cement mantle which is uninterrupted in its length and adequate in its thickness. Our results suggest that some current systems require modification.