header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

PAPER 141: GAP FILLING AND ENHANCED OSTEOCONDUCTION ASSOCIATED WITH ALENDRONATE COATED POROUS TANTALUM



Abstract

Purpose: Porous tantalum has been shown to be very effective in achieving bone ingrowth. However, in some circumstances, bone quality or quantity is insufficient to allow adequate bone ingrowth. We hypothesized that the addition of alendronate to porous tantalum would enhance the ability of porous tantalum to achieve bone ingrowth in these challenging situations, such as when a gap exists between the implant and bone. We evaluated the effect of alendronate coated porous tantalum on new bone formation in an animal model incorporating a gap between implant and bone.

Method: Thirty-six cylindrical porous tantalum implants were bilaterally implanted into the distal femur of 18 rabbits for 4 weeks. There were 3 groups of implants inserted; a control group of porous tantalum with no coatings, porous tantalum with micro-porous calcium phosphate coating, and porous tantalum coated with micro-porous calcium phosphate and alendronate. Subcutaneous fluorescent labeling was used to track new bone formation. Bone formation was analyzed by backscattered electron microscopy and fluorescent microscopy on undecalcified samples.

Results: The relative increase in mean volume of gap filling, bone ingrowth and total bone formation was 143% (p< 0.001), 259% (p< 0.001) and 193% (p< 0.001) respectively in the alendronate coated porous tantalum compared with the uncoated porous tantalum controls. The relative increase in the percentage of new bone-implant contact length was increased by 804% on average in the alendronate coated porous tantalum compared with the uncoated tantalum controls.

Conclusion: This study demonstrated the significant enhancement of bone-implant gap filling and bone ingrowth which can be achieved by coating porous tantalum with alendronate. It is proposed that, when faced with the clinical problem of revision joint replacement in the face of bone loss (at the hip, knee or elsewhere), the addition of an alendronate-delivery surface coating would enhance biological fixation of the implant and promote the healing of bone defects.

Correspondence should be addressed to Meghan Corbeil, Meetings Coordinator Email: meghan@canorth.org