header advert
Results 1 - 40 of 40
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_5 | Pages 2 - 2
1 Mar 2021
Higuera-Rueda C Emara A Nieves-Malloure Y Klika AK Cooper H Cross M Guild G Nam D Nett M Scuderi G Cushner F Silverman R
Full Access

Aim

This was a multicenter, randomized, clinical trial to compare the 90-day 1) incidence of surgical site complications (SSC); 2) health care utilization (the number of dressing changes, readmission, and reoperation); and 3) the patient-reported outcomes (PRO) in high-risk patients undergoing revision total knee arthroplasty (rTKA) with postoperative closed incision negative pressure wound therapy (ciNPT) versus a standard of care (SOC) silver-impregnated occlusive dressing.

Method

A total of 294 rTKA patients (15 centers) at high-risk for wound complications were prospectively randomized to receive either SOC or ciNPT (n = 147 each). The ciNPT system was adjusted at 125 mmHg of suction. Investigated outcomes were assessed weekly up to 90 days after surgery. A preset interim analysis was conducted at 50% of the intended sample size, with planned discontinuation for clear efficacy/harm if a significance of p < 0.005 was attained.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 57 - 57
1 Feb 2021
Elmasry S Chalmers B Sculco P Kahlenberg C Mayman D Wright T Westrich G Cross M Imhauser C
Full Access

Introduction

Surgeons commonly resect additional distal femur during primary total knee arthroplasty (TKA) to correct a flexion contracture to restore range of motion and knee function. However, the effect of joint line elevation on the resulting TKA kinematics including frontal plane laxity is unclear. Thus, our goal was to quantify the effect of additional distal femoral resection on passive extension and mid-flexion laxity.

Methods

Six computational knee models with capsular and collateral ligament properties specific to TKA were developed and implanted with a contemporary posterior-stabilized TKA. A 10° flexion contracture was modeled by imposing capsular contracture as determined by simulating a common clinical exam of knee extension and accounting for the length and weight of each limb segment from which the models were derived (Figure 1). Distal femoral resections of 2 mm and 4 mm were simulated for each model. The knees were then extended by applying the measured knee moments to quantify the amount of knee extension. The output data were compared with a previous cadaveric study using a two-sample two-tailed t-test (p<0.05) [1]. Subsequently, varus and valgus torques of ±10 Nm were applied as the knee was flexed from 0° to 90° at the baseline, and after distal resections of 2 mm, and 4 mm. Coronal laxity, defined as the sum of varus and valgus angulation in response to the applied varus and valgus torques, was measured at 30° and 45°of flexion, and the flexion angle was identified where the increase in laxity was the greatest with respect to baseline.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 63 - 63
1 Oct 2020
Wright TM Kahlenberg C Elmasry S Mayman D Cross M Pearle A Westrich G Imhauser C Sculco P
Full Access

Introduction

In total knee arthroplasty (TKA), tibial insert thickness is determined intraoperatively by applying forces that generate varus-valgus moments at the knee and estimating the resulting gaps. However, how the magnitude of applied moments and the surgeon's perception of gaps affect the thickness selection is unclear. We determined this relationship using an in vitro human cadaveric model.

Methods

Six pelvis-to-toe specimens (72±6 years old, four females) were implanted by an expert surgeon with a PS TKA using measured resection. Pliable sensors were wrapped around medial and lateral aspects of the foot and ankle to measure the applied forces. The forces were scaled by limb length to obtain the moments generated at the knee. Six surgeons with different experience levels independently assessed balance by applying moments in extension and 90° of flexion and choosing the insert they believed fit each knee. Peak moments and the accompanying extension and flexion gap openings as perceived by surgeons were recorded. The two measures were then related to insert choice using a generalized estimating equation.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 7 - 7
1 Oct 2020
Goswami K Clarkson S Dennis DA Klatt BA O'Malley M Smith EL Pelt CE Gililland J Peters C Malkani AL Palumbo B Minter J Goyal N Cross M Prieto H Lee G Hansen E Ward D Bini S Higuera C Levine B Nam D Della Valle CJ Parvizi J
Full Access

Introduction

Surgical management of PJI remains challenging with patients failing treatment despite the best efforts. An important question is whether these later failures reflect reinfection or the persistence of infection. Proponents of reinfection believe hosts are vulnerable to developing infection and new organisms emerge. The alternative hypothesis is that later failure is a result of an organism that was present in the joint but was not picked up by initial culture or was not a pathogen initially but became so under antibiotic pressure. This multicenter study explores the above dilemma. Utilizing next-generation sequencing (NGS), we hypothesize that failures after two stage exchange arthroplasty can be caused by an organism that was present at the time of initial surgery but not isolated by culture.

Methods

This prospective study involving 15 institutions collected samples from 635 revision total hip (n=310) and knee (n=325) arthroplasties. Synovial fluid, tissue and swabs were obtained intraoperatively for NGS analysis. Patients were classified per 2018 Consensus definition of PJI. Treatment failure was defined as reoperation for infection that yielded positive cultures, during minimum 1-year follow-up. Concordance of the infecting pathogen cultured at failure with NGS analysis at initial revision was determined.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 48 - 48
1 Oct 2020
Alamanda VK Sapountzis N Joseph A Chiu Y Cross M Windsor RE Rodriguez JA
Full Access

Introduction

Instability following total knee arthroplasty is a leading cause of failure and is often treated with component revision. The goal of this study was to determine if isolated tibial polyethylene insert exchange (ITPIE) to a higher-level constraint would afford similar outcomes to component revision in the properly selected patient.

Methods

We retrospectively evaluated 176 consecutive patients between 2016–2017 who were revised for symptomatic instability at a single institution. Demographic information and level of constraint preoperatively and postoperatively were documented. Radiographic parameters were also recorded for patients undergoing ITPIE. Outcome measures included all cause re-revision rates as well as patient reported outcome measures (PROMs) obtained preoperatively and at minimum 1-yr follow up. Descriptive analysis including sample t-test and chi square test were performed with statistical significance set at p <0.05.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 31 - 31
1 May 2019
Cross M
Full Access

The management of bone loss in revision total knee replacement (TKA) remains a challenge. To accomplish the goals of revision TKA, the surgeon needs to choose the appropriate implant design to “fix the problem,” achieve proper component placement and alignment, and obtain robust short- and long-term fixation. Proper identification and classification of the extent of bone loss and deformity will aid in preoperative planning. Extensive bone loss may be due to progressive osteolysis (a mechanism of failure), or as a result of intraoperative component removal. The Anderson Orthopaedic Research Institute (AORI) is a useful classification system that individually describes femoral and tibial defects by the appearance, severity, and location of bone defects. This system provides a guideline to treatment and enables preoperative planning on radiographs.

In Type 1 defects, femoral and tibial defects are characterised by minor contained deficiencies at the bone-implant interface. Metaphyseal bone is intact and the integrity of the joint line is not compromised. In this scenario, the best reconstruction option is to increase the thickness of bone resection and to fill the defect with cancellous bone graft or cement. Type 2 defects are characterised by deficient metaphyseal bone involving one or more femoral condyle(s) or tibial plateau(s). The peripheral rim of cortical bone may be intact or partially compromised, and the joint line is abnormal. Reconstruction options for a Type 2A defect include impaction bone grafting, cement, or more commonly, prosthetic augmentation (e.g. sleeves, augments or wedges). In Type 2B defects, metaphyseal bone of both femoral condyles or both tibial plateaus is deficient. The peripheral rim of cortical bone may be intact or partially compromised, and the joint line is abnormal. Options for a Type 2B defect include impaction grafting, bulk structural allograft, prosthetic augmentation, metaphyseal sleeves (in some cases), or metaphyseal cones. Finally, in the presence of a Type 3 deficiency, both metaphyseal and cortical bone is deficient and there is partial or complete disruption of the collateral ligament attachments. In this case, the most commonly used reconstruction options include hinged implants or megaprostheses with or without bulk structural allograft, prosthetic augmentation, and/or metaphyseal/diaphyseal sleeves or cones.

Today, we are fortunate to have a wide variety of options available to aid in reconstruction of a revision TKA with massive bone loss. Historically, use of cement, bone grafting, or use of a tumor-type or hinged implant were considered the main options for reconstruction. The development and adoption of highly porous sleeves and cones has given the surgeon a new and potentially more durable option for reconstruction of previously difficult to treat defects. Using radiographs and computed tomography, surgeons are able to preoperatively classify bone loss and anticipate a reconstruction plan based upon the classification; however, it is always important to have several back-up options on hand during revision surgery in the event bone loss is worse than expected.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 89 - 89
1 Feb 2017
Dai Y Angibaud L Rueff M Cross M Swanson K Crozier M Williams B Jung A
Full Access

INTRODUCTION

While multiple factors contribute to the variability of prosthesis placement during total knee arthroplasty (TKA), the accuracy of the surgeon's resection planning (positioning of the cutting block) is arguably the most critical. One may postulate that proper training, including enabling the surgeon to passively receive quantitative feedback on the cutting block position, may help him/her improve resection accuracy. The purpose of this study was to test the hypothesis that passive reception of feedback on cutting block position improves the accuracy of the successive TKA resection planning.

Materials and Methods

Five cadaveric knees (tibia and foot only) were studied. After arthrotomy, the tracker of an imageless navigation system (ExactechGPS®, Blue-Ortho, Grenoble, FR) was attached to the tibia. A navigated TKA procedure was initiated starting with registration of anatomical landmarks. Four surgeons then positioned the tibial cutting block (without pinning) on each knee using standard extramedullary mechanical instruments. The planned target resection was neutral varus/valgus, 3° posterior slope, and 10mm resection depth referencing the lateral plateau. Each surgeon performed 3 planning trials on each of the 5 knees, removing the cutting block between attempts. The planned resections were measured using an instrumented checker provided with the navigation system, referencing the cutting block. Surgeons were informed of the resection parameters measured by the navigation system after each planning trial. The deviations in resection parameters between the resection target and the cutting block position were calculated for each planning trial. The effect of receiving passive feedback on the accuracy of successive placement of the cutting block was assessed by comparing the deviations between each surgeon's 3 trials on the same cadaver (paired-t test). Statistical significance was defined as p<0.05.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 15 - 15
1 Feb 2017
Angibaud L Dai Y Rueff M Cross M Swanson K Crozier M Williams B Jung A
Full Access

INTRODUCTION

The alignment of components in total knee arthroplasty (TKA) is perceived to be one of the most influential factors in determining the long-term outcomes. A contemporary debate exists regarding the choice of the alignment method. As a vast majority of the surgeons support the basis of the mechanical alignment philosophy (MA), others believe in the concept of anatomical alignment theory (AA) to closely match the anatomy of the femur and the tibia of the native knee [1]. This study was intended to evaluate the accuracy of achieving a planned tibial resection target using either the MA or AA methods.

Materials and Methods

Five healthy cadaveric knees (tibia and foot only) were studied. Four surgeons were independently asked to position a tibial cutting block (without pinning) using conventional extramedullary mechanical instrumentation (Exactech LPI instrumentation, Gainesville, FL, USA). Surgeons were asked to target a predefined proximal tibial cut according to MA (Varus= 0°, posterior slope= 3°, resection level= 10 mm) or to AA (Varus= 3°, posterior slope= 6°, resection level= 9 mm). Once the surgeon expressed satisfaction with the achieved position of the tibial cutting block, the planned resection was recorded using an imageless guidance system (ExactechGPS®, Blue-Ortho, Grenoble, FR). Surgeons completed at least three positioning trial for each alignment method on each cadaver. The accuracy and outliers (deviated more than 2°/mm from the target [2]) of resection planning were compared between the MA and AA methods. Statistical significance was defined as p< 0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 19 - 19
1 May 2016
Angibaud L Dai Y Jenny J Cross M Hamad C Jung A
Full Access

Introduction

Total knee arthroplasty (TKA) can effectively treat end-stage knee osteoarthritis. For cruciate-retaining (CR) TKA, the posterior tibial slope (PTS) of the reconstructed proximal tibia plays a significant role in restoring normal knee kinematics as it directly affects the tension of the posterior cruciate ligament (PCL) [1]. However, conventional cadaveric testing of the impact of PTS on knee kinematics may damage/stretch the PCL, therefore impact the test reproducibility. The purpose of this study was to assess the reproducibility of a novel method for the evaluation of the effects of PTS on knee kinematics.

Materials and Methods

Cemented CR TKAs (Logic CR, Exactech, Gainesville, FL, USA) were performed using a computer-assisted surgical guidance system (ExactechGPS®, Blue-Ortho, Grenoble, FR) on six fresh frozen non-arthritic knees (PCL presumably intact). The tibial baseplate was specially designed (Fig. 1) with a mechanism to modify the PTS in-situ. Knee kinematics, including anteroposterior (AP) translation, internal/external (IE) rotation, and hip-knee-ankle angles, were evaluated by performing a passive range of motion from extension up to ∼110° of flexion, three separate times at 5 PTSs: 10°, 7°, 4°, 1°, and then 10° again. The repeatability of the test was investigated by comparing the kinematics between the first and the last 10° tests. Any clinically relevant deviation (1.5° for the hip knee ankle angle, 1.5mm for anterior-posterior translation and 3° for internal-external rotation) would reflect damage to the soft-tissue envelope or the PCL during the evaluation. Potential damage of PCL was investigated by comparing the kinematic parameters from the first and last 10° slope tests at selected flexion angles (Table 1) by paired t-test, with statistical significance defined as p<0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 23 - 23
1 May 2016
Schwarzkopf R Cross M Huges D Laster S Lenz N
Full Access

Introduction

Achieving proper ligament tension in knee flexion within cruciate retaining (CR) total knee arthroplasty (TKA) has long been associated with clinical success. The distal femoral joint line (DFJL) is routinely used as a variable to assist in achieving proper flexion-extension gap balancing. No prior study has observed the possible effects of properly restoring the DFJL may have on ligament tension in flexion. The purpose of this computational analysis was to determine what effect the DFJL may have on ligament strains and tibiofemoral kinematics of CR knee designs in flexion.

Methods

A computational analysis was performed utilizing a musculoskeletal modeling system with ligaments modeled as non-linear elastic. Tibiofemoral kinematics, contact points estimated from the femoral condyle low points, and ligament strain, change in length relative to the unloaded length, were measured at 90° knee flexion during a deep knee bend activity. Two different knee implants, a High Flexion CR (HFCR) and a Guided Motion CR (GMCR) design were used. Simulations were completed for changes in superior-inferior (SI) positioning of the femoral implant relative to the femur bone, in 2mm increments to simulate over and under resection of the DFJL.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 72 - 72
1 May 2016
Carroll K Levack A Schnaser E Potter H Cross M
Full Access

Introduction

The current recommendation by the AAOS in the 2010 clinical practice guidelines for the use of MRI to diagnose a periprosthetic joint infection (PJI) is “inconclusive” given the lack of evidence to support its use. The purpose of this study was to determine the utility of MRI with metal reduction artifact sequencing in diagnosing a periprosthetic joint infection (PJI) after total hip arthroplasty (THA).

Methods

176 patients who underwent MRI with multi-acquisition variable resonance image combination (MAVRIC) to reduce metal artifact for a painful THA between the years of 2009–2013 were retrospectively evaluated. All MRIs were read by one of four radiologists with extensive experience in interpreting MRIs after THA. All MRIs were performed using a 1.5 Tesla magnet. Of the 176 patients examined, 16 patients were found to have a deep periprosthetic joint infection using Musculoskeletal Infection Society (MSIS) criteria after the MRI was performed. MRI reads were classified as either positive (read as “evidence of active infection” or “suspicious for infection”) or negative (read as no evidence of infection). Only one patient who had a positive MRI read was excluded because of loss to followup after the MRI was performed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 22 - 22
1 May 2016
Schwarzkopf R Huges D Laster S Lenz N Cross M
Full Access

Introduction

Achieving proper ligament tension in knee flexion within posterior cruciate retaining (CR) total knee arthroplasty (TKA) has long been associated with clinical success. Ligament balance has been achieved through specific surgical technique steps. No prior study evaluated the possible effects of varying levels of posterior cruciate ligament (PCL) release on femorotibial contact location and PCL ligament strain. The purpose of this computational analysis was to determine what effect-varying levels of PCL release may have on the tibiofemoral kinematics and PCL strain.

Methods

A computational analysis was performed utilizing a musculoskeletal modeling system with ligaments modeled as non-linear elastic structures and ligament insertions. A single CR knee system with two different tibial insert designs was tested, a Guided Motion (GM) and an ultra-congruent, Deep Dished (DD) design. Varying levels of PCL release were simulated by setting the stiffness of both bundles of the PCL to a percentage, ranging from 0–100% in 25% increments. Tibiofemoral kinematics was evaluated by measuring the contact points estimated from the femoral condyle low points, and ligament strain of the anterior-lateral (AL) and posterior-medial (PM) bundles. The maximum PCL strain was determined for each bundle to evaluate the risk of PCL rupture based on the PCL failure strain.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 21 - 21
1 May 2016
Hamad C Jung A Jenny J Cross M Angibaud L Hohl N Dai Y
Full Access

Introduction

While total knee arthroplasty (TKA) improves postoperative function and relieves pain in the majority of patients with end stage osteoarthritis, its ability to restore normal knee kinematics is debated. Cadaveric studies using computer-assisted orthopaedic surgery (CAOS) system [1] are one of the most commonly used methods in the assessment of post-TKA knee kinematics. Commonly, these studies are performed with an open arthrotomy; which may impact the knee kinematics. The purpose of this cadaveric study was to compare the knee kinematics before and after (open or closed) arthrotomy.

Materials and Methods

Kinematics of seven non-arthritic, fresh-frozen cadaveric knees (PCL presumably intact) was evaluated using a custom software application in an image-free CAOS system (ExactechGPS, Blue-Ortho, Grenoble, FR). Prior to the surgical incision, one tracker was attached to the diaphysis of each tibia and femur. Native intact knee kinematics was then assessed by performing passive range of motion (ROM) three separate times, from full extension to at least 110 degrees of flexion, with the CAOS system measuring and recording anatomical values, including flexion angle, internal-external (IE) rotation and anterior-posterior (AP) translation of the tibia relatively to the femur, and the hip-knee-ankle (HKA) angle. Next, an anterior incision with a medial parapatellar arthrotomy was performed, followed by acquisition of the anatomical landmarks used for establishing an anatomical coordinate system in which all the anatomical values were evaluated [2]. The passive ROM test was then repeated with closed and then open arthrotomy (patella manually maintained in the trochlea groove). The anatomical values before and after knee arthrotomy were compared over the range of knee flexion using the native knee values as the baseline.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 135 - 135
1 May 2016
Kia M Imhauser C Warth L Lipman J Westrich G Cross M Mayman D Pearle A Wright T
Full Access

Introduction

Medial unicompartmental knee arthroplasty (UKA) restores mechanical alignment and reduces lateral subluxation of the tibia. However, medial compartment translation remains abnormal compared to the native knee in mid-flexion Intra-operative adjustment of implant thickness can modulate ligament tension and may improve knee kinematics. However, the relationship between insert thickness, ligament loads, and knee kinematics is not well understood. Therefore, we used a computational model to assess the sensitivity of knee kinematics, and cruciate and collateral ligament forces to tibial component thickness with fixed bearing medial UKA.

Methods

A computational model of the knee with subject-specific bone geometries, articular cartilage, and menisci was developed using multibody dynamics software (Fig 1a). The ligaments were represented with multiple non-linear, tension-only force elements, and incorporated mean structural properties. The 3D geometries of the femoral and tibial components of the Stryker Triathlon fixed-bearing UKA were captured using a laser scanner. An arthroplasty surgeon aligned the femoral and tibial components to the articular surfaces within the model (Fig 1b). The intact and UKA models were passively flexed from 0 to 90° under a 10 N compressive load. The tibial polyethylene insert was modeled by the orthopaedic surgeon to create a “balanced” knee. The modeled polyethylene insert thickness was then increased by 2 mm and decreased 2mm (in increments of 1mm) to simulate over- and under-stuffing, respectively. Outcomes were anterior-posterior (AP) translation of the femur on the tibia in the medial compartment, and forces seen by the ACL and MCL during mid-flexion (from 30 to 60° flexion). The mean differences between the intact knee model and all other experimental conditions for each outcome were calculated across mid-flexion.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 20 - 20
1 May 2016
Dai Y Angibaud L Hamad C Jung A Jenny J Cross M
Full Access

INTRODUCTION

Cemented total knee arthroplasty (TKA) is a widely accepted treatment for end-stage knee osteoarthritis. During this procedure, the surgeon targets proper alignment of the leg and balanced flexion/extension gaps. However, the cement layer may impact the placement of the component, leading to changes in the mechanical alignment and gap size. The goal of the study was to assess the impact of cement layer on the tibial mechanical alignment and joint gap during cemented TKA.

MATERIAL

Computer-assisted TKAs (ExactechGPS®, Blue-Ortho, Grenoble, FR) were performed by two fellowship trained orthorpaedic surgeons on five fresh-frozen non-arthritic pelvis-to-ankle cadaver legs. All the surgeries used a cemented cruciate retaining system (Optetrak Logic CR, Exactech, Gainesville, FL). After the bony resection, the proximal tibial resection plane was acquired by manually pressing an instrumented checker onto the resected tibial surface (resection plane). Once the prosthesis was implanted through standard cementing techniques, the top surface of the implanted tibial component was probed and recorded using an instrumented probe. A best fit plane was then calculated from the probed points and offset by the thickness of the prosthesis, representing the bottom plane of the component (component plane).

The deviation of component alignment caused by the cement layer was calculated as the coronal and sagittal projection of the three-dimensional angle between the resection plane and the component plane. The deviation of the component height, reflecting a change in the joint gap, was assessed as the distance between the two planes calculated at the lowest points on the medial and lateral compartments of the proximal tibial surface. Statistical significance was defined as p≤0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 27 - 27
1 May 2016
Carroll K Patel A Carli A Cross M Jerabek S Mayman D
Full Access

Introduction

While implant designs and surgical techniques have improved in total knee arthroplasty (TKA), approximately 20% of patients remain dissatisfied. The purpose of this study was to determine if reproduction of anatomic preoperative measurements correlated to improved clinical outcomes in TKA.

Methods

We retrospectively reviewed95 patients (106 knees) who underwent a TKA between 2012 −2013 with a minimum of one year follow-up. All patients had a pre and post-operative SF-12 and WOMAC scores. Pre and 6 week post-operative radiographs were reviewed to compare restoration of coronal plane alignment, maintenance of joint line obliquity, and maintenance of tibial varus. Coronal alignment was defined as the angle formed between the mechanical axis of the femur and the the tibia. Joint line obliquity was defined as the angle between the mechanical axis of the limb and the line which best parallels the joint space at the knee. Tibial varus was compared between the preoperative proximal lateral tibial angle and the angle formed by the mechanical axis of the tibia and tibial component postoperatively.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 65 - 65
1 May 2016
Jenny J Cross M Hamad C Bertrand F Angibaud L Dai Y
Full Access

INTRODUCTION

Total knee arthroplasty (TKA) is an effective technique to treat end-stage osteoarthritis of the knee. One important goal of the procedure is to restore physiological knee kinematics. However, fluoroscopy studies have consistently shown abnormal knee kinematics after TKA, which may lead to suboptimal clinical outcomes. Posterior slope of the tibial component may significantly impact the knee kinematics after TKA. There is currently no consensus about the most appropriate slope. The goal of the present study was to analyze the impact of different prosthetic slopes on the kinematics of a PCL-preserving TKA. The tested hypothesis was that the knee kinematics will be different for all tested tibial slopes.

MATERIAL

PCL-retaining TKAs (Optetrak Logic CR, Exactech, Gainesville, FL) were performed by fellowship trained orthopedic surgeons on six fresh frozen cadaver with healthy knees and intact PCL. The TKA was implanted using a computer-assisted surgical navigation system (ExactechGPS®, Blue-Ortho, Grenoble, FR). The implanted tibial baseplate was specially designed (figure 1) to allow modifying the posterior slope without repeatedly removing/assembling the tibial insert with varying posterior slopes, avoiding potential damages to the soft-tissue envelope.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 34 - 34
1 Feb 2016
Hamad C Bertrand F Jenny J Cross M Angibaud L Hohl N Dai Y
Full Access

Although total knee arthroplasty (TKA) is a largely successful procedure to treat end-stage knee osteoarthritis (OA), some studies have shown postoperative abnormal knee kinematics. Computer assisted orthopaedic surgery (CAOS) technology has been used to understand preoperative knee kinematics with an open joint (arthrotomy). However, limited information is available on the impact of arthrotomy on the knee kinematics. This study compared knee kinematics before and after arthrotomy to the native knee using a CAOS system.

Kinematics of a healthy knee from a fresh frozen cadaver with presumably intact PCL were evaluated using a custom software application in an image-free CAOS system (ExactechGPS, Blue-Ortho, Grenoble, FR). At the beginning of the test, four metal hooks were inserted into the knee away from the joint line (one on each side of the proximal tibia and the distal femur) for the application of 50N compressive load to simulate natural knee joint. Prior to incision, one tracker was attached to each tibia and femur on the diaphysis. Intact knee kinematics were recorded using the CAOS system by performing passive range of motion 3 times. Next, a computer-assisted TKA procedure was initiated with acquisition of the anatomical landmarks. The system calculated the previously recorded kinematics within the coordinate system defined by the landmarks. The test was then repeated with closed arthrotomy, and again with open arthrotomy with patella maintained in the trochlea groove. The average femorotibial AP displacement and rotation, and HKA angle before and after knee arthrotomy were compared over the range of knee flexion. Statistical analysis (ANOVA) was performed on the data at ∼0° (5°), 30°, 60°, 90° and 120° flexion.

The intact knee kinematics were found to be similar to the kinematics with closed and open arthrotomy. Differences between the three situations were found, in average, as less than 0.25° (±0.2) in HKA, 0.7mm (±0.4) in femorotibial AP displacement and 2.3° (±1.4) in femorotibial rotation. Although some statistically significant differences were found, especially in the rotation of the tibia for low and high knee flexion angles, the majority is less than 1°/mm, and therefore clinically irrelevant.

This study suggested that open and closed arthrotomy do not significantly alter the kinematics compared to the native intact knee (low RMS). Maintaining the patella in the trochlea groove with an open arthrotomy allows accurate assessment of the intact knee kinematics.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 12 - 12
1 Feb 2016
Jenny J Cross M Hamad C Bertrand F Angibaud L Dai Y
Full Access

Total knee arthroplasty (TKA) is an effective technique to treat end-stage knee osteoarthritis, targeting the restore a physiological knee kinematics. However, studies have shown abnormal knee kinematics after TKA which may lead to suboptimal clinical outcomes. Posterior slope of the tibial component may significantly impact the knee kinematics. There is currently no consensus about the most appropriate slope. The goal of the present study was to analyse the impact of different prosthetic slopes on the kinematics of a PCL-preserving TKA, with the hypothesis that posterior slopes can alter the knee kinematics.

A PCL-retaining TKA (Optetrak CR, Exactech, Gainesville, FL) was performed by a board-certified orthopaedic surgeon on one fresh frozen cadaver that had a non arthritic knee with an intact PCL. Intact knee kinematic was assessed using a computer-assisted orthopaedic surgery (CAOS) system (ExactechGPS®, Blue-Ortho, Grenoble, FR) Then, TKA components were implanted using the guidance of the CAOS system. The implanted tibial baseplate was specially designed to allow modifying the posterior slope without repeatedly removing/assembling the tibial insert with varying posterior slopes, avoiding potential damages to the soft-tissue envelope. Knee kinematic was evaluated by performing a passive range of motion 3 separate times at each of the 4 posterior slopes: 10°, 7°, 4° and 1°, and recorded by the navigation system. Femorotibial rotation, antero-posterior (AP) translation and hip-knee-ankle (HKA) angle were plotted with regard to the knee flexion angle.

Tibial slopes of 1° and 4° significantly altered the normal rotational kinematics. Tibial slopes of 7° and 10° led to a kinematics close to the original native knee. All tibial slopes significantly altered the changes in HKA before 90° of knee flexion, without significant difference between the different slopes tested. The magnitude of change was small. There was no significant change in the AP kinematics between native knee and all tested tibial slopes.

Changing the tibial slope significantly impacted the TKA kinematics. However, in the implant studied, only the rotational kinematics were significantly impacted by the change in tibial slope. Tibial slopes of 7° and 10° led rotational kinematics that were closest to that of a normal knee. Alterations in knee kinematics related to changing tibial slope may be related to a change in the PCL strain. However, these results must be confirmed by other tests involving more specimens.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 27 - 27
1 Feb 2015
Cross M
Full Access

Background:

Failed metal-on-metal (MOM) bearings and corrosion reactions are being increasingly encountered with little to guide evaluation for periprosthetic joint infection (PJI). Our purpose was to determine the utility of the erythrocyte sedimentation rate (ESR), C-Reactive Protein (CRP), synovial fluid white blood cell (WBC) count and differential (%PMN) in diagnosing PJI in failed hips with a MOM bearing or corrosion.

Methods:

150 revision hips (92 MOM total hip arthroplasties, 19 MOM hip resurfacings, 30 non-MOM bearings with corrosion and 9 full-thickness bearing surface wear with metallosis) were retrospectively evaluated. Nineteen patients were diagnosed as infected using MSIS criteria. Mean laboratory values were compared between groups and receiver operator characteristic curves (ROC) generated with an area under the curve (AUC) to determine test performance and optimal cutoffs.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 63 - 63
1 Aug 2013
Klingenstein G Cross M Plaskos C Li A Nam D Lyman S Pearle AD Mayman D
Full Access

Introduction

The aim of this study was to quantify mid-flexion laxity in a total knee arthroplasty with an elevated joint line, as compared to a native knee and a TKA with joint line maintained. Our hypothesis was joint line elevation of 4mm would increase coronal plane laxity throughout mid-flexion in a pattern distinct from the preoperative knee or in a TKA with native joint line.

Methods

Six fresh-frozen cadaver legs from hip-to-toe underwent TKA with a posterior stabilised implant (APEX PS, OMNIlife Science, Inc.) using a computer navigation system equipped with a robotic cutting-guide, in this controlled laboratory cadaveric study. After the initial tibial and femoral resections were performed, the flexion and extension gaps were balanced using navigation, and a 4mm recut was made in the distal femur. The remaining femoral cuts were made, the femoral component was downsized by resecting an additional 4mm of bone off the posterior condyles, and the polyethylene was increased by 4mm to create a situation of a well-balanced knee with an elevated joint line. The navigation system was used to measure overall coronal plane laxity by measuring the mechanical alignment angle at maximum extension, 30, 45, 60 and 90(of flexion, when applying a standardised varus/valgus load of 9.8Nm across the knee using a 4kg spring-load located at 25cm distal to the knee joint line. Laxity was also measured in the native knee, as well as the native knee after a standard approach during TKA which included a medial release. Coronal plane laxity was defined as the absolute difference (in degrees) between the mean mechanical alignment angle obtained from applying a standardised varus and valgus stress at 0, 30, 45, 60 and 90(.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 97 - 97
1 Oct 2012
Hammoud S Suero E Maak T Rozell J Inra M Jones K Cross M Pearle A
Full Access

Controversies about the management of injuries to the soft tissue structures of the posteromedial corner of the knee and the contribution of such peripheral structures on rotational stability of the knee are of increasing interest and currently remain inadequately characterised. The posterior oblique ligament (POL) is a fibrous extension off the distal aspect of the semimembranosus that blends with and reinforces the posteromedial aspect of the joint capsule. The POL is reported to be a primary restraint to internal rotation and a secondary restraint to valgus translation and external rotation. Although its role as a static stabiliser to the medial knee has been previously described, the effect of the posterior oblique ligament (POL) injuries on tibiofemoral stability during Lachman and pivot shift examination in the setting of ACL injury is unknown.

The objective of this study was to quantify the magnitude of tibiofemoral translation during the Lachman and pivot shift tests after serial sectioning of the ACL and POL.

Eight knees were used for this study. Ligamentous constraints were sequentially sectioned in the following order: ACL first, followed by the POL. Navigated mechanised pivot shift and Lachman examinations were performed before and after each structure was sectioned, and tibiofemoral translation was recorded.

Lachman test: There was a mean 6.0 mm of lateral compartment translation in the intact knee (SD = 3.3 mm). After sectioning the ACL, translation increased to 13.8 mm (SD = 4.6; P<0.05). There was a nonsignificant 0.7 mm increase in translation after sectioning the POL (mean = 14.5 mm; SD = 3.9 P>0.05).

Mechanised pivot shift: Mean lateral compartment translation in the intact knee was −1.2 mm (SD = 3.2 mm). Sectioning the ACL caused an increase in anterior tibial translation (mean = 6.7 mm; SD = 3.0 mm; P<0.05). No significant change in translation was seen after sectioning the POL (mean = 7.0 mm, SD = 4.0 mm; P>0.05).

Sectioning the POL did not significantly alter tibiofemoral translation in the ACL deficient knee during the Lachman and pivot shift tests. This study brings into question whether injuries to the POL require reconstruction in conjunction with ACL reconstruction. More studies are needed to further characterise the role of the injured POL in knee stability and its clinical relevance in the ACL deficient and reconstructed knee.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 101 - 101
1 Oct 2012
Hammoud S Suero E Maak T Rozell J Inra M Jones K Cross M Pearle A
Full Access

Controversies about the management of injuries to the soft tissue structures of the posteromedial corner of the knee and the contribution of such peripheral structures on rotational stability of the knee are of increasing interest and currently remain inadequately characterised. The posterior oblique ligament (POL) is a fibrous extension off the distal aspect of the semimembranosus that blends with and reinforces the posteromedial aspect of the joint capsule. The POL is reported to be a primary restraint to internal rotation and a secondary restraint to valgus translation and external rotation. Although its role as a static stabiliser to the medial knee has been previously described, the effect of the posterior oblique ligament (POL) injuries on tibiofemoral stability during Lachman and pivot shift examination in the setting of ACL injury is unknown.

The objective of this study was to quantify the magnitude of tibiofemoral translation during the Lachman and pivot shift tests after serial sectioning of the ACL and POL.

Eight knees were used for this study. Ligamentous constraints were sequentially sectioned in the following order: ACL first, followed by the POL. Navigated mechanised pivot shift and Lachman examinations were performed before and after each structure was sectioned, and tibiofemoral translation was recorded.

Lachman test: There was a mean 6.0 mm of lateral compartment translation in the intact knee (SD = 3.3 mm). After sectioning the ACL, translation increased to 13.8 mm (SD = 4.6; P<0.05). There was a nonsignificant 0.7 mm increase in translation after sectioning the POL (mean = 14.5 mm; SD = 3.9 P>0.05).

Mechanised pivot shift: Mean lateral compartment translation in the intact knee was −1.2 mm (SD = 3.2 mm). Sectioning the ACL caused an increase in anterior tibial translation (mean = 6.7 mm; SD = 3.0 mm; P<0.05). No significant change in translation was seen after sectioning the POL (mean = 7.0 mm, SD = 4.0 mm; P>0.05).

Sectioning the POL did not significantly alter tibiofemoral translation in the ACL deficient knee during the Lachman and pivot shift tests. This study brings into question whether injuries to the POL require reconstruction in conjunction with ACL reconstruction. More studies are needed to further characterise the role of the injured POL in knee stability and its clinical relevance in the ACL deficient and reconstructed knee.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 94 - 94
1 Oct 2012
Suero E Rozell J Inra M Cross M Ranawat A Pearle A
Full Access

Unicompartmental knee replacement (UKR) has good outcomes for the treatment of compartmental osteoarthritis of the knee. Mechanical alignment overcorrection is associated with early failure of the femoral and tibial components. Preoperative mechanical alignment is the most important predictor of postoperative alignment. However, most studies do not take into consideration the magnitude of preoperative deformity when reporting on mechanical alignment outcomes after UKR.

We aimed to determine the magnitude of postoperative mechanical alignment achieved based on the magnitude of preoperative alignment; and to compare the number of cases of overcorrection into valgus to historical data.

This was a radiographic review of patients who underwent robotic medial UKR by a single surgeon between 2007 and 2011. Two examiners measured pre- and postoperative mechanical alignment for all patients on long-leg radiographs. Patients were classified into three groups of preoperative mechanical alignment: mild varus (0–5®); moderate varus (5–10®); and severe varus (>10®). Patients with valgus alignment (<0®) were excluded. Linear regression was used to estimate the magnitude of postoperative alignment for each group, adjusting for age, BMI, gender, side, implant type, and polyethylene thickness.

89 patients were included. Mean preoperative alignment was 7.3® varus (95% CI = 6.6®–8®; range, 0.1–15® varus). Mean postoperative alignment was 2.8® varus (95% CI = 1.9®–3.8®; range, 1.4® valgus–9.7® varus). There was a significant difference in postoperative mechanical alignment between the three groups (Table 1) (P<0.05). Four overcorrections (4.5%) were detected, all under 1.5® valgus. This percentage of overcorrection was significantly better than previous conventional UKR reports (mean = 12.6%; P = 0.04).

The magnitude of postoperative alignment in medial UKR depends on the severity of the preoperative deformity. Reports on radiographic outcomes of UKR should be stratified by the magnitude of preoperative alignment. The risk of overcorrection is reduced when using robotic assistance compared to using the conventional manual technique.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 119 - 119
1 Mar 2012
Murray J Sherlock M Hogan N Palmer S Servant C Cross M
Full Access

The anterior femoral cortical line (AFCL) is an anatomical landmark which has been used by the senior author for 20 years to assess femoral rotation in over 4000 TKR's. The AFCL describes the alignment of the anterior cortex of the distal femur proximal to the trochlear articular cartilage.

The AFCL was compared with the surgical epicondylar (SEA), anteroposterior (Whiteside's line) and posterior condylar (PC) axes using 50 dry-bone cadaveric femora, 16 wet cadaveric specimens, 50 axial MRI's and 58 TKR patients intra-operatively.

In the dry-bone/cadaveric femora (measuring relative to the SEA the AFCL and Whiteside's AP axis were 1° externally rotated and the PC axis was 1° internally rotated. By MRI (relative to the SEA) the AFCL was 8° internally rotated, Whiteside's was 2° externally rotated and the PC axis was 3° internally rotated. In the clinical study (measuring relative to a perpendicular to Whiteside's line alone) the AFCL was 4° degrees internally rotated, which equates to 2-3° of internal rotation relative to the SEA.

The AFCL is another axis, completing the ‘compass points’ around the knee. It may prove particularly useful when one or all of the other reference axes are disturbed such as in revision TKR, lateral condylar hypoplasia or where there has been previous epicondylar trauma. We suggest building in 5° external rotation with respect to the anterior femoral cortical line for femoral component rotation.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 32 - 32
1 Mar 2009
Murray J Sherlock M Hogan N Servant C Palmer S Parish E Cross M
Full Access

Background: The purpose of this study was to assess the anterior femoral cortical line (AFCL) as an additional anatomical landmark for determining intraoperative femoral component rotation in total knee arthroplasty. The AFCL was compared with the Epicondylar axis, the anteroposterior (AP) axis (Whiteside’s line), and the posterior condylar axis. Dry bone, cadaver, MRI and intra-operative measurements were compared.

Methods: Fifty dry bone femora, and 16 wet cadaveric specimens were assessed to identify the AFCL and this was compared against the 3 reference axes discussed above. Photographs were taken of the specimens with K-wires/marker pins secured to the reference axes and then a digital on-screen goniometer was used to determine the mean angular variations with respect to the Epipcondylar axis.

In the clinical trial, 58 consecutive patients undergoing total knee arthroplasty were included. After a routine exposure the AP axis was marked on each distal femur. The AFCL was then identified and the anterior femoral cortical cut was made parallel to this line. The angle between this cortical cut and the perpendicular to the AP axis was measured using a sterile goniometer.

In the MRI study, 50 axial knee images were assessed and the most appropriate slice/s determined in order to identify the AFCL and the other 3 reference axes and then their relationship was measured by an on-screen goniometer.

Results: In the cadaveric study the AFCL was a mean 1° externally rotated to the epicondylar axis (SD = 5°), White-side’s line was 1° externally rotated (SD = 4°) and the posterior condylar axis was 1° internally rotated (SD = 2°)

By MRI and with respect to the epicondylar axis, the AFCL was a mean 5° externally rotated (SD= 3), White-side’s Line was 1° externally rotated (SD = 2) and the posterior condylar axis was 3° internally rotated (SD = 2).

In the clinical study in 8 patients it was impossible to draw the AP axis because of dysplasia or destruction of the trochlea by osteoarthrosis. In the remainder the mean difference between the anterior femoral cortical line and Whiteside’s AP axis was 4.1 degrees internally rotated (SD = 3.8°). The lateral release rate for this cohort was 4%.

Conclusion: The anterior femoral cortical line provides an additional reference point, completing the ‘compass points’ around the knee. It has been shown in this study to be reliable in the laboratory, on MRI and in a clinical setting for assessing rotation of the femoral component. It may prove particularly useful when one or all of the other reference axes are disturbed such as in revision TKR, lateral condylar hypoplasia or where there has been previous epicondylar trauma.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 572 - 572
1 Aug 2008
Murray J Sherlock M Hogan N Servant C Palmer S Cross M
Full Access

Purpose: To assess the anterior femoral cortical line (AFCL) as an additional anatomical landmark for determining intraoperative femoral component rotation in total knee arthroplasty. The anterior femoral cortical line (AFCL) is an anatomical landmark which has been used by the senior author for 20 years to assess femoral rotation in over 4000 TKRs. The AFCL describes the alignment of the anterior cortex of the distal femur proximal to the trochlear articular cartilage.

Methods: The AFCL was compared with the surgical epicondylar axis (SEA), anteroposterior axis (Whiteside’s line) and posterior condylar (PC) axis using 50 dry-bone cadaveric femora, 16 wet cadaveric specimens, 50 axial MRI scans and 58 TKR patients intra-operatively.

Results: In the dry-bone and cadaveric femora (measuring relative to the SEA) the AFCL and Whiteside’s AP axis were 1° externally rotated and the PC axis was 1° internally rotated. With MRI (relative to the SEA) the AFCL was 8° internally rotated, Whiteside’s was 2° externally rotated and the PC axis was 3° internally rotated. In the clinical study (measuring relative to a perpendicular to Whiteside’s line alone) the AFCL was 4° degrees internally rotated, which equates to 2–3° of internal rotation relative to the SEA.

Conclusion: The AFCL is another axis, completing the ‘compass points’ around the knee. It may prove particularly useful when one or all of the other reference axes are disturbed such as in revision TKR, lateral condylar hypoplasia or where there has been previous epicondylar trauma. We suggest building in 5° external rotation with respect to the anterior femoral cortical line when judging femoral component rotation.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 255 - 255
1 May 2006
Hutchinson J Parish E Cross M
Full Access

Introduction: Stiffness following Total Knee Arthroplasty is a serious and debilitating complication. There are many different patient and surgical factors implicated in it cause. Previous studies have suggested that it will occur in approximately 1% of TKR patients. Arthrofibrosis is an uncommon but potentially debilitating cause in an otherwise well positioned implant. The cause of this abnormal scar formation is as yet unknown. The treatment of this condition remains difficult and controversial. Revision of the TKR has been suggested as the gold standard treatment as other operative strategies have had limited success. Our approach to this problem has been to conserve the prosthesis and try to release the scar tissue.

Aim: The aim of this study is to assess the results of open arthrolysis in the treatment of established arthrofibrosis.

Method: 1522 patients undergoing primary uncemented TKR have been prospectively followed up (2022 TKR’s) using the International Knee Society Scores. 13 patients underwent open Arthrolysis for stiffness post-op (Incidence 0.64%). The average age was 65 (range 50–78). 6 cases were simultaneous bilateral procedures (Incidence 1.2% of simultaneous bilateral procedures). The average time between TKR and arthrolysis was 14 months. Our average follow-op was 7.2 years (range 2 – 10 years)

Results: The average ROM just prior to Arthrolysis was 58°. The average ROM six months after surgery had improved to 91° (p< 0.05). The average ROM at last follow-up was 95° (p< 0.05) with an average Knee Society score of 155 (pain 83, function 72).

No patients have required revision of their components.

Conclusions: We have found open arthrolysis a successful approach to post-op arthrofibrosis. Although a large procedure it has been well tolerated by our patients. They have had an improvement in range of movement by six months which has been maintained up to 10 years.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 86 - 86
1 Mar 2006
Hutchinson J Parish E Cross M
Full Access

Introduction The efficacy of total knee replacement (TKR) surgery is well documented throughout the literature. Results from cemented and cementless series reveal similar long-term reliable results in terms of function and survival. Less, however, is known of the long-term results of uncemented TKR with the use of hydroxyapatite (HA). The purpose of this paper is to present the long-term results of a series of TKR using an uncemented, HA-coated, PCL retaining prosthesis.

Method During the period from August 1992 to December 1994 all patients undergoing TKR surgery were prospectively recorded in a consecutive series. Results were recorded pre- and post-surgery at regular intervals (both clinically and radiographically). The combined clinical Knee Society Score was used to evaluate outcome with routine radiographic evaluation done at 10 years.

Results 217 patients (126 female, 91 male) were included in the study with 322 knees in total (75 simultaneous bilateral, 23 staged bilateral and 126 unilateral). The mean age was 70 years (range 34–88 years) with a mean follow-up of 11 years (range 10–12 years). 47 (21.7%) patients were deceased at 10 years. The principle indication for surgery was osteoarthritis. There has been 1 revision (0.3%) for infection in this series to date. There have been 7 (2.2%) deep infections requiring surgical intervention and 4 (1.2%) supracondylar fractures.

At 10 years, mean knee score was 174 with range of movement 0–111 degrees. 95.4% of the series has currently been successfully followed up. 9 patients were unable to be contacted and lost to follow up. With revision as an end point, the rate of survival for the prosthesis at 10 years is 99.4%. Assuming worst case scenario for patients lost to follow up, survivorship is 95.4%.

Conclusion The survival of this prosthesis has shown to compare favourably to other published results. A low rate of revision and infection combined with excellent clinical and functional outcomes suggests the use of HA with an uncemented TKR produces reliable long-term results.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 339 - 339
1 Sep 2005
Cross M Parish E
Full Access

Introduction and Aims: Use of bioceramic coatings to enhance fixation of joint arthroplasties is a relatively new concept that has yet to prove long-term, reliable results in knee arthroplasty. The purpose of this study was to prospectively report on the medium- to long-term outcomes of an uncemented, hydroxyapatite coated total knee replacement (TKR).

Method: Between August 1992 and 2002 all patients in a consecutive series requiring primary TKR were treated with an uncemented, hydroxyapatite coated, posterior cruciate ligament retaining prosthesis implanted by the senior author. A combined Knee Society Clinical rating score (producing a maximum score of 200) was prospectively collected prior to surgery and post-operatively at three and six months and one, two, five and 10 years thereafter. Fluoroscopically controlled interface images were obtained from the first 161 knees immediately and again at two years post-operatively to evaluate the progression of osseointergration.

Results: One thousand two hundred and thirty-five patients (M:F; 605:630) with a mean age of 67 years (range 34–97 years) underwent TKR mainly for osteoarthritis (94%) and inflammatory arthropathies (3%). Mean follow-up was 78 months (range 20–145 months). There were 720 unilateral and 1030 bilateral replacements (824 simultaneous, 206 staged) with 1750 replacements in total. Mean pre-operative knee score was 97 with a range of movement (ROM) from seven to 114 degrees. At five and 10 years, scores were 182 and 178 with a ROM of one to 114 and zero to 112 degrees respectively. Sixty-one (4.9%) patients have died since surgery including two peri-operative deaths for MI. There have been 12 (0.7%) cases requiring revision, primarily for septic loosening (six cases). There have been 16 deep infections (0.9%), 29 proven pulmonary emboli (1.7%) and five periprosthetic fractures (0.3%). There has been one (0.06%) case of aseptic loosening requiring revision.

Conclusion: These results reveal with an adequately designed prosthesis the use of hydroxyapatite in TKR produces reliable osseointergration that is comparable to other methods of fixation as demonstrated with minimal revision rate and incidence of loosening. The clinical results produce excellent ROM with good medical and functional outcomes in the long term.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1221 - 1221
1 Nov 2004
DIXON P PARISH E CROSS M


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 468 - 468
1 Apr 2004
Cross M Parish E
Full Access

Introduction The decision to perform bilateral total knee replacement (TKR) either simultaneously or as a staged procedure is made depending on the level of disease severity, comorbidities, total anaesthetic time and cost. We compared the outcomes of these two bilateral groups of patients with unilateral TKR.

Methods Between August 1992 and December 2002 all patients requiring primary TKR received an uncemented, hydroxyapatite-coated, posterior cruciate ligament retaining prosthesis implanted by the senior author. All peri-operative complications were recorded prospectively, as were pre-operative and post-operative knee scores (Knee Society Clinical Rating Score) at three and six months, and one, two, five, and 10 years thereafter. Patients were divided into three groups being; simultaneous bilateral TKR (SIM), staged bilateral TKR (STA), and unilateral TKR (SIN) with the outcomes of each group compared for statistical significance. One thousand one hundred and forty patients (1638 knees) were included in the study. The majority of patients were female in the STA and SIN groups (60% and 53% respectively) and males in the SIM group (57%). There were 790 (SIM), 206 (STA), and 642 (SIN) knees with mean ages of 67 (SIM), 65 (STA), and 67 years (SIN). The primary diagnosis was OA in each of the groups (> 93%).

Results Pre-operative and post-operative scores revealed no significant differences (p> .05) between the groups. Mean scores ranged from 94 to 98 pre-operatively and increased up to 182 to 187 at five years. Post-operative complications were significantly higher (p< .01) in both bilateral groups. There were 68 (17.2%) and 16 (15.5%) cases of thrombi in the SIM and STA groups respectively compared to 60 (9.3%) cases in the SIN group. Pulmonary emboli were also significantly higher in the bilateral groups compared to the unilateral group (p< .01). The rate of deep infection was higher (p=.09) in the STA group compared to the SIM and SIN groups (2.9% of patients compared to 1.1% and 1.4% respectively). There have been 10 revisions (four SIM, one STA, and five SIN) and two cases of peri-operative death (one STA, one SIM) both due to MI.

Conclusions While simultaneous TKR has higher rates of post-operative complication compared to unilateral TKR, it is less than staged TKR. Therefore simultaneous bilateral knee replacements, when indicated, are the ideal treatment of choice compared to staged procedures.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 5 - 5
1 Jan 2004
Chitnavis J Dixon P Parish E Cross M
Full Access

Although hydroxyapatite (HA) coating is known to enhance fixation in THR, its role in the fixation of Total Knee Replacements is less well appreciated. This study was performed to assess the medium-term results of an HA-coated TKR.

Between August 1992 and 1998 all patients requiring a primary TKR were treated with a hydroxyapatite-coated, PCL-retaining prosthesis implanted by the senior author. The HA coating used was 70 microns thick with 75% crystallinity and 20% porosity. It is deposited on a beaded heat-sintered surface. A combined Hospital for Special Surgery and Knee Society Score was recorded pre-operatively and at three, six, 12, 24 and 60 months post-operatively. Fluoroscopically-controlled interface views were performed on the first 161 knees immediately post-operatively and repeated 24 months postoperatively.

Six hundred and ninety two patients (Male:Female 335:357) with a mean age of 68 years (31–88 years) underwent 1 000 TKR mainly for OA (93%) and inflammatory arthropathies (RA 3%, psoriasis 1%). The mean follow up was 75 months (40–115). There were 461 unilateral (R:L 256:205) and 539 bilateral replacements (462 simultaneous and 77 staged).

The pre-operative knee score was 95/200, ROM 6–115 degrees and at latest review was 182/200, ROM 1–113 degrees.

Forty four patients have died (mean age 73 years, range 54 to 88). There have been 14 deep infections (1.4%), 22 proven pulmonary emboli (2.2%) and five periprosthetic fractures (0.5%). Six revisions have been performed. Visible gaps between bone and implant were present in 91% of femora and 58% of tibiae initially and in 6% of femora and 8% of tibiae at two years on interface views. There have been no cases of clinical loosening.

Currently, this study comprises the largest known series of HA-coated total knee replacements. These results demonstrate that HA appears to enhance fixation of uncemented knee prostheses which maintain good clinical outcomes.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 176 - 176
1 Feb 2003
Servant C Bradbury N Holt M Cross M
Full Access

Arthrofibrosis following ACL reconstruction prevents the patient from regaining full knee movement postoperatively.

Our aim was to determine whether acute reconstruction (performed within 3 weeks of injury) is associated with an increased risk of arthrofibrosis compared with chronic reconstruction (performed more than 8 weeks after injury).

We performed a prospective study of 114 patients who underwent a patellar tendon ACL reconstruction: 62 patients underwent acute reconstruction and 52 patients underwent chronic reconstruction. All patients were operated on by a single surgeon using a standardised arthroscopic technique and accelerated rehabilitation programme. All patients were assessed independently by an experienced physiotherapist at an average of 7 months post-operatively. Range of motion, stability, muscle strength and functional scores were measured.

There was no significant difference in the incidence of arthrofibrosis between the acute and chronic groups. Flexion of less than 125° or a loss of extension of more than 10° occurred in 8 (12.9%) of the acute group and in 9 (17.3%) of the chronic group.

All knees were clinically stable, but the mean KT1000 difference was 1.21mm in the acute group and 1.89mm in the chronic group (p< 0.05). There were no significant differences in muscle strength or functional scores between the two groups.

There were significantly more meniscal injuries (65% versus 31%) and chondral lesions (31% versus 18%) in the chronic group.

Acute ACL reconstruction is not associated with an increased risk of arthrofibrosis. However, it is associated with increased stability and less meniscal and chondral pathology. This study suggests that the optimum time for ACL reconstruction is within the first 3 weeks after injury.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 119 - 119
1 Feb 2003
Palmer SH Machan S Cross M
Full Access

The purpose of this study was to assess whether there was significant variation in distal femoral morphology between individuals. In the first part of this study we analysed the distal femoral morphology of 100 consecutive patients undergoing routine total knee replacement for osteoarthritis. In the second part we reviewed the morphology of 50 cadaveric distal femoral specimens without osteoarthritis. There was considerable variability in distal femoral morphology.

Our findings suggest that: 1, use of the posterior condylar axis for femoral component alignment should be used cautiously; 2, problems in balancing flexion and extension gaps on both sides of the knee can be predicted; 3, a greater range of femoral component shapes should be available.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 269 - 269
1 Nov 2002
Cross M Roger G Morgan-Jones R Machan S Parish E
Full Access

Introduction: The Motus (Osteo) total knee replacement design is an uncemented, stemless, hydroxyapatite-coated prosthesis designed as a low profile resurfacing implant.

Aim: To review the results after five to eight years of the use of this prosthesis by one surgeon and to discuss the perceived advantages of its design.

Methods: Between 1992 and 1996 the Motus (Osteo) prosthesis was used in 606 primary total knee replacements in 409 patients. The evaluation was undertaken using a clinical knee score based on the Knee Society Score and the Hospital for Special Surgery (HSS) score, which produces a maximum score of 200/200.

Results: The mean age was 69 years (range: 31 to 88 years) with 53% of the patients being female. Osteoarthritis was the underlying pathology in the majority of the cases. The minimum time to follow up was 60 months (mean: 79, range: 60 to 104 months). The mean pre-operative knee score was 98/200 with a range of movement from six degrees to 122 degrees. After five years, the mean knee score was 180/200 with a range of movement from one degree to 113 degrees. To date only two patients have required a revision procedure, both for deep infection. Twenty-six patients have died and six have been lost to follow-up as they are overseas.

Conclusion: At a minimum five-year review, the Motus (Osteo) total knee replacement prosthesis produced excellent functional and clinical results with a low rate of complications.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 251 - 251
1 Nov 2002
Palmer S Machan S Cross M
Full Access

Introduction: Dysfunction of the patellofemoral mechanism presents as patella dislocation or subluxation with or without anterior knee pain. Causes are numerous and include ligamentous deficiency, muscular deficiency, anomlies of bony alignment and patellofemoral joint abnormalities. The 130 different procedures described to treat this condition reflect the multiple pathologies responsible. No single procedure has gained widespread acceptance. We present a surgical technique that attempts to correct as many of these deficiencies of the patellofemoral mechanism as possible.

Method: The procedure consists of a lateral release, a vastus medialis tendon advancement and a tibial tubercle osteotomy. The ‘Q’ angle is corrected by medialisation of the tubercle, patella alta is corrected by a distalisation technique and joint reaction forces through the patellofemoral joint are reduced by placing the tibial tuberosity in a more anterior position.

100 patients who have undergone this procedure have been identified. 81 percent initially presented with patella subluxation or dislocation. The remainder complained of anterior knee pain with evidence of abnormal patella tracking on examination. 52 percent of our patients had undergone at least one previous patellofemoral realignment procedure which had failed. 43 percent of the patients had generalised ligamentous laxity.

Results: The mean follow-up was 2.6 years from the index operation. 81 percent of the patients stated the operation had improved or abolished their symptoms. Generalised ligamentous laxity was present in the remaining 19 percent and seemed to correlate with a poor outcome. 66 percent of patients stated they were satisfied with the outcome of the surgery. Two patients developed recurrent subluxation after surgery and one of these has undergone a revision distal realignment procedure.

Using the functional category described by Crosby and Insall for patellofemoral symptoms 66 percent had a good-to-excellent outcome, 23 percent had a fair outcome and 10 percent of the patients stated they were worse following the procedure with increased anterior knee pain. 100 percent of these patients had grade 3 or 4 cartilage defects on retropatella surface. 57% of patients returned to sporting activity. 14% of the remainder had not returned to sporting activity because of persisting symptoms in the knee.

57 percent of patients had lost a mean 12.5 degrees of flexion of the knee at follow-up [range 5–30]. 5 percent of patients developed minor complications following surgery. No radiological deterioration was seen in any patients although coexistent patellofemoral osteoarthritis was seen in 25 percent of patients. There was no loss of fixation in any of the patients.

Discussion: A multifaceted approach to the complex problem of patellofemoral dysfunction appears to achieve satisfactory functional results in patients even when previous surgical realignment has failed. The procedure appears to be associated with low morbidity although a loss of flexion of the knee is to be expected. Generalised ligamentous laxity and cartilage defects on the retropatella surface appear to be associated with poor results and anterior knee pain in the absence of instability may be a cause for persisting symptoms.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 242 - 244
1 Mar 1995
Nakhostine M Perko M Cross M

We report four patients with a mean age of 17 years (14 to 22) with external rotation injuries of the knee in slight flexion. Radiographs showed a small fragment in the area of the lateral femoral condyle. At operation, the fragment, consisting of the femoral insertion of the popliteus, was anatomically reduced and fixed. At a mean follow-up of 35 months all the knees had an excellent function score. An isolated lesion of the popliteus often presents as a tendon avulsion whereas major damage to the posterolateral corner of the knee involves combined ligamentous injuries. In patients with an acute haemarthrosis and lateral pain in a stable knee, the diagnosis of isolated avulsion of the popliteus tendon should be suspected. Arthroscopy with special attention to the lateral gutter is indicated. We advise anatomical reduction and fixation of the fragment to prevent possible long-term effects on other posterolateral structures.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 625 - 627
1 Jul 1990
Wootton Cross M Holt K

We report three cases of avulsion of the ischial tuberosity with marked chronic disability after delay in diagnosis and non-union of the fracture. All were treated by open reduction and internal fixation with return to full function, allowing in one case, athletic performances of Olympic standard. We also report one patient with an acute apophyseal avulsion treated by early reduction and internal fixation with restoration of full function.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 300 - 300
1 Mar 1987
Cross M Schmidt D Mackie I