header advert
Results 101 - 120 of 4366
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 17 - 17
2 Jan 2024
Ramos-Díez S Camarero-Espinosa S
Full Access

Articular cartilage is a multi-zonal tissue that coats the epiphysis of long bones and avoids its wear during motion. An unusual friction could micro-fracture this connective membrane and progress into an osteochondral defect (OD), where the affected cartilage suffers inflammation, fibrillation, and forfeiture of its anisotropic structure.

Clinical treatment for ODs has been focused on micro-fracture techniques, where the defect area is removed and small incisions are performed in the subchondral bone, which allows the exudation of mesenchymal stem cells (hMSCs) to the abraded zone. However, hMSCs represent less than 0.01% of the total cell population and are not able to self-organise coherently, so the treatments fail in the long term. To select, support and steer hMSCs from the bone marrow into a specific differentiation stage, and recreate the cartilage anisotropic microenvironment, multilayer dual-porosity 3D-printed scaffolds were developed.

Dual-porosity scaffolds were printed using prepared inks, containing specific ratios of poly-(d,l)lactide-co-caprolactone copolymer and gelatine microspheres of different diameters, which acted as sacrificial micro-pore templates and were leached after printing. The cell adhesion capability was investigated showing an increased cell number in dual-porosity scaffolds as compared to non-porous ones. To mimic the stiffness of the three cartilage zones, several patterns were designed, printed, and checked by dynamic-mechanical analysis under compression at 37 ºC. Three patterns with specific formulations were chosen as candidates to recreate the mechanical properties of the cartilage layers. Differentiation studies in the selected scaffolds showed the formation of mature cartilage by gene expression, protein deposition and biomolecular analysis. Given the obtained results, designed scaffolds were able to guide hMSC behaviour.

In conclusion, biocompatible, multilayer and dual-porosity scaffolds with cell entrapment capability were manufactured. These anisotropic scaffolds were able to recreate the physical microenvironment of the natural cartilage, which in turn stimulated cell differentiation and the formation of mature cartilage.

Acknowledgments: This work was supported by the EMAKIKER grant.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 118 - 118
2 Jan 2024
Stroobant L Verstraete M Onsem S Victor J Chevalier A
Full Access

Numerous papers present in-vivo knee kinematics data following total knee arthroplasty (TKA) from fluoroscopic testing. Comparing data is challenging given the large number of factors that potentially affect the reported kinematics. This paper aims at understanding the effect of following three different factors: implant geometry, performed activity and analysis method.

A total of 30 patients who underwent TKA were included in this study. This group was subdivided in three equal groups: each group receiving a different type of posterior stabilized total knee prosthesis. During single-plane fluoroscopic analysis, each patient performed three activities: open chain flexion extension, closed chain squatting and chair-rising. The 2D fluoroscopic data were subsequently converted to 3D implant positions and used to evaluate the tibiofemoral contact points and landmark-based kinematic parameters.

Significantly different anteroposterior translations and internal-external rotations were observed between the considered implants. In the lateral compartment, these differences only appeared after post-cam engagement. Comparing the activities, a significant more posterior position was observed for both the medial and lateral compartment in the closed chain activities during mid-flexion. A strong and significant correlation was found between the contact-points and landmarks-based analyses method. However, large individual variations were also observed, yielding a difference of up to 25% in anteroposterior position between both methods.

In conclusion, all three evaluated factors significantly affect the obtained tibiofemoral kinematics. The individual implant design significantly affects the anteroposterior tibiofemoral position, internal-external rotation and timing of post-cam engagement. Both kinematics and post-cam engagement additionally depend on the activity investigated, with a more posterior position and associated higher patella lever arm for the closed chain activities. Attention should also be paid to the considered analysis method and associated kinematics definition: analyzing the tibiofemoral contact points potentially yields significantly different results compared to a landmark-based approach.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 61 - 61
2 Jan 2024
Graziani G
Full Access

Functionalization of biomimetic nanomaterials allows to reproduce the composition of native bone, permitting better regeneration, while nanoscale surface morphologies provide cues for cell adhesion, proliferation and differentiation. Functionalization of 3D printed and bioprinted constructs, by plasma-assisted deposition of calcium phosphates-based (CaP) nanostructured coatings and by nanoparticles, respectively, will be presented. Stoichiometric and ion doped CaP- based nanocoatings, including green materials (mussel seashells and cuttlefish bone), will be introduced to guide tissue regeneration. We will show interactions between biomimetic surfaces and MSCs to address bone regeneration and SAOS-2 cells for bone tumor models. Our results show that combining AM and nanostructured biomimetic films permits to reproduce the architecture and the mechanical and compositional characteristics of bone. Stability behavior of the coatings, as well as MSCs behavior strongly depend on the starting CaP material, with more soluble CaPs and ion-doped ones showing better biological behavior. Green materials appear promising, as biomimetic films can be successfully obtained upon conversion of the marine precursors into hydroxyapatite. Last-not-least, nanoparticles-loaded scaffolds could be bioprinting without loss of cell viability, but ink characteristics depend on ion-doping as demonstrated for SAOS-2 cells over 14 days of culture. Biomimetic nanomaterials for functionalization in AM is a promising approach for bone modelling and regeneration.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 62 - 62
2 Jan 2024
Platania V Tavernaraki N Gontika I Fragiadaki E Triantopoulou N Papadaki H Alpantaki K Vidaki M Chatzinikolaidou M
Full Access

Biofabrication is a popular technique to produce personalized constructs for tissue engineering. In this study we combined laponite (Lap), gellan gum (GG) with platelet-rich plasma (PRP) aiming to enhance the endothelial regeneration through the synergistic effects of their individual properties. Laponite has the ability to form porous three-dimensional networks mimicking the extracellular matrix structure, and PRP delivery of growth factors stimulates the endothelial cell proliferation and migration, offering a composite bioink for cell growth and support. The sustained release of these growth factors from the GG-laponite-PRP composite material over time provides a continuous source of stimulation for the cells, leading to more effective tissue engineering strategies for endothelial tissue regeneration. Four blend compositions comprising 1% w/v GG and 0.5 or 1% w/v Lap and 25% v/v PRP were combined with Wharton jelly mesenchymal stem cells (WJ-MSCs) and bioprinted into vessel-like structures with an inner diameter of 3 mm and a wall thickness of 1 mm. Stress/strain analysis revealed the elastomeric properties of the hydrogels with Young modulus values of 10 MPa. Increasing the Lap concentration led to a non-significant decrease of swelling ratio from 93 to 91%. Live/dead assay revealed cell viability of at least 76%, with the 0.5%Lap-GG viability exceeding 99% on day 21. Gradual increase of glycosaminoglycans accumulation and collagen production indicate promotion of ECM formation. The expression and membranous localization of PECAM-1 from day 7 and the granular intracellular localization of vWF after 2 weeks demonstrate in vitro endothelial functionality. In vivo subcutaneous implantation indicated the absence of any adverse immunological reactions. The results reveal the expression of both vWF and PECAM-1 by WJ-MSCs entrapped in all four construct compositions with significantly higher expression of vWF in the presence of PRP.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 63 - 63
2 Jan 2024
Charbonnier B Guyon L Touya N Dutilleul M Véziers J Maitre P Gauthier O Corre P Weiss P
Full Access

Developments in the field of additive manufacturing have allowed significant improvements in the design and production of scaffolds with biologically relevant features to treat bone defects. Unfortunately, the workflow to generate personalized scaffolds is source of inaccuracies leading to a poor fit between the implant and patients' bone defects. In addition, scaffolds are often brittle and fragile, uneasing their handling by surgeons, with significant risks of fracture during their insertion in the defect. Consequently, we developed organo-mineral cementitious scaffolds displaying evolutive mechanical properties which are currently being evaluated to treat maxillofacial bone deformities in veterinary clinics. Treatment of dog patients was approved by ethic and welfare committees (CERVO-2022-14-V). To date, 8 puppies with cleft palate/lip deformities received the following treatment. Two weeks prior surgery, CT-scan of patient's skull was performed to allow for surgical planning and scaffold designing. Organo-mineral printable pastes were formulated by mixing an inorganic cement precursor (α-Ca3(PO4)2) to a self-reticulating hydrogel (silanized hyaluronic acid) supplemented with a viscosifier (hydroxymethylpropylcellulose). Scaffolds were produced by robocasting of these pastes. Surgical interventions included the reconstruction of soft tissues, and the insertion of the scaffold soaked with autologous bone marrow. Bone formation was monitored 3 and 6 months after reconstruction, and a biopsy at 6 months was performed for more detailed analyses. Scaffolds displayed great handling properties and were inserted within bone defects without significant issue with a relevant bone edges/scaffold contact. Osteointegration of the scaffolds was observed after 3 months, and regeneration of the defect at 6 months seemed quite promising. Preliminary results have demonstrated a potential of the set-up strategy to treat cleft lip/palate deformities in real, spontaneous clinical setting. Translation of these innovative scaffolds to orthopedics is planned for a near future.


In osteoarthritis, chondrocytes acquire a hypertrophic phenotype that contributes to matrix degradation. Inflammation is proposed as trigger for the shift to a hypertrophic phenotype. Using in vitro culture of human chondrocytes and cartilage explants we could not find evidence for a role of inflammatory signalling activation. We found, however, that tissue repair macrophages may contribute to the onset of hypertrophy (doi: 10.1177/19476035211021907) Intra-articularly injected triamcinolone acetonide to inhibit inflammation in a murine model of collagenase-induced osteoarthritis, increased synovial macrophage numbers and osteophytosis, confirming the role of macrophages in chondrocyte hypertrophy occurring in osteophyte formation (doi: 10.1111/bph.15780).

In search of targets to inhibit chondrocyte hypertrophy, we combined existing microarray data of different cartilage layers of murine growth plate and murine articular cartilage after induction of collagenase-induced osteoarthritis. We identified common differentially expressed genes and selected those known to be associated to inflammation. This revealed EPHA2, a tyrosine kinase receptor, as a new target. Using in silico, in vitro and in vivo models we demonstrated that inhibition of EPHA2 might be a promising treatment for osteoarthritis.

Recently, single cell RNA-seq. has revealed detailed information about different populations of chondrocytes in articular cartilage during osteoarthritis. We re-analysed a published scRNA-seq data set of healthy and osteoarthritic cartilage to obtain the differentially expressed genes in the population of hypertrophic chondrocytes compared to the other chondrocytes, applied pathway analyses and then used drug databases to search for upstream inhibitors of these pathways. This drug repurposing approach led to the selection of 6 drugs that were screened and tested using several in vitro models with human chondrocytes and cartilage explants.

In this lecture I will present this sequence of studies to highlight different approaches and models that can be used in the quest for a disease modifying drug for osteoarthritis.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 140 - 140
2 Jan 2024
van der Weegen W Warren T Agricola R Das D Siebelt M
Full Access

Artificial Intelligence (AI) is becoming more powerful but is barely used to counter the growth in health care burden. AI applications to increase efficiency in orthopedics are rare. We questioned if (1) we could train machine learning (ML) algorithms, based on answers from digitalized history taking questionnaires, to predict treatment of hip osteoartritis (either conservative or surgical); (2) such an algorithm could streamline clinical consultation.

Multiple ML models were trained on 600 annotated (80% training, 20% test) digital history taking questionnaires, acquired before consultation. Best performing models, based on balanced accuracy and optimized automated hyperparameter tuning, were build into our daily clinical orthopedic practice. Fifty patients with hip complaints (>45 years) were prospectively predicted and planned (partly blinded, partly unblinded) for consultation with the physician assistant (conservative) or orthopedic surgeon (operative). Tailored patient information based on the prediction was automatically sent to a smartphone app. Level of evidence: IV.

Random Forest and BernoulliNB were the most accurate ML models (0.75 balanced accuracy). Treatment prediction was correct in 45 out of 50 consultations (90%), p<0.0001 (sign and binomial test). Specialized consultations where conservatively predicted patients were seen by the physician assistant and surgical patients by the orthopedic surgeon were highly appreciated and effective.

Treatment strategy of hip osteoartritis based on answers from digital history taking questionnaires was accurately predicted before patients entered the hospital. This can make outpatient consultation scheduling more efficient and tailor pre-consultation patient education.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 37 - 37
2 Jan 2024
Mineiro J
Full Access

In March 2020, COVID-19 was declared a pandemic by the World Health Organization. The pandemic imposed drastic changes in our social and professional routine. Professionally at all levels our hospital tasks were changed and prioritized. Surgeons and residents were deployed on rotations to fields other than their expertise in orthopaedics. Health-care education received major changes in these challenging times, and students did face difficulties in receiving education, as well as training due to limited clinical and surgical exposure.

In response to the WHO regulations, most of the teaching centres and hospitals worldwide have adopted the web-based teaching and learning model to continue the education and training of orthopaedic residents. These results brought significant changes to the training experience in orthopaedic surgery in combination with the fact that clinical duty hours and case volume were substantially reduced.

In what concerns orthopaedic journal publications, the Covid-19 pandemic resulted in a decline in the annual publication rate for the first time in over 20 years. Although not uniform, the reduction was most likely due to multifactorial causes.

Regarding the appraisal at the end of training, at the Orthopaedic European Board Examination we were able to verify that the outcome at the written part 1 exam was good, equivalent to the outcome prior to the pandemic. However the oral viva was much worse, probably due to the fact that residents skipped much of the clinical and surgical teaching and exposure during 2020 and 2021. At the end of training, theoretical/factual knowledge was good but poor from the clinical practical experience.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 43 - 43
2 Jan 2024
Lipreri M Cortini M Baldini N Avnet S
Full Access

Osteosarcoma is a highly malignant primary tumor of bone tissue. The 5-year survival rate of patients with metastasis is below 20% and this scenario is unchanged in the last two decades, despite great efforts in pre-clinical and clinical research. Traditional preclinical models of osteosarcoma do not consider the whole complexity of its microenvironment, leading to poor correlation between in vitro/in vivo results and clinical outcomes. Spheroids are a promising in vitro model to mimic osteosarcoma and perform drug-screening tests, as they (i) reproduce the microarchitecture of the tumor, (ii) are characterized by hypoxic regions and necrotic core as the in vivo tumor, (iii) and recapitulate the chemo-resistance phenomena. However, to date, the spheroid model is scarcely used in osteosarcoma research.

Our aim is to develop a customized culture dish to grow and characterize spheroids and to perform advanced drug-screening tests. The resulting platform must be adapted to automated image acquisition systems, to overcome the drawbacks of commercial spheroids platforms.

To this purpose, we designed and developed a micro-patterned culture dish by casting agarose on a 3D printed mold from a CAD design. We successfully obtained viable and reproducible homotypic osteosarcoma spheroids, with two different cells lines from osteosarcoma (i.e., 143b and MG-63). Using the platform, we performed viability assays and live fluorescent stainings (e.g., Calcein AM) with low reagent consumption. Moreover, the culture dish was validated as drug screening platform, administrating Doxorubicin at different doses, and evaluating its effect on OS spheroids, in terms of morphology and viability. This platform can be considered an attractive alternative to the highly expensive commercial spheroid platforms to obtain homogeneous and reproducible spheroids in a high-throughput and cost effective mode.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 5 - 5
2 Jan 2024
Huyghe M Peiffer M Cuigniez F Tampere T Ashkani-Esfahani S D'Hooghe P Audenaert E Burssens A
Full Access

One-fourth of all ankle trauma involve injury to the syndesmotic ankle complex, which may lead to syndesmotic instability and/or posttraumatic ankle osteoarthritis in the long term if left untreated. The diagnosis of these injuries still poses a deceitful challenge, as MRI scans lack physiologic weightbearing and plain weightbearing radiographs are subject to beam rotation and lack 3D information. Weightbearing cone-beam CT (WBCT) overcomes these challenges by imaging both ankles during bipedal stance, but ongoingdebate remains whether these should be taken under weightbearing conditions and/or during application of external rotation stress. The aim of this study is study therefore to compare both conditions in the assessment of syndesmotic ankle injuries using WBCT imaging combined with 3D measurement techniques.

In this retrospective study, 21 patients with an acute ankle injury were analyzed using a WBCT. Patients with confirmed syndesmotic ligament injury on MRI were included, while fracture associated syndesmotic injuries were excluded. WBCT imaging was performed in weightbearing and combined weightbearing-external rotation. In the latter, the patient was asked to internally rotate the shin until pain (VAS>8/10) or a maximal range of motion was encountered. 3D models were developed from the CT slices, whereafter. The following 3D measurements were calculated using a custom-made Matlab® script; Anterior tibiofibular distance (AFTD), Alpha angle, posterior Tibiofibular distance (PFTD) and Talar rotation (TR) in comparison to the contralateral non-injured ankle.

The difference in neutral-stressed Alpha angle and AFTD were significant between patients with a syndesmotic ankle lesion and contralateral control (P=0.046 and P=0.039, respectively). There was no significant difference in neutral-stressed PFTD and TR angle.

Combined weightbearing-external rotation during CT scanning revealed an increased AFTD in patients with syndesmotic ligament injuries. Based on this study, application of external rotation during WBCT scans could enhance the diagnostic accuracy of subtle syndesmotic instability.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 6 - 6
2 Jan 2024
Orellana F Grassi A Wahl P Nuss K Neels A Zaffagnini S Parrilli A
Full Access

A comprehensive understanding of the self-repair abilities of menisci and their overall function in the knee joint requires three-dimensional information. However, previous investigations of the meniscal blood supply have been limited to two-dimensional imaging methods, which fail to accurately capture tissue complexity. In this study, micro-CT was used to analyse the 3D microvascular structure of the meniscus, providing a detailed visualization and precise quantification of the vascular network.

A contrast agent (μAngiofil®) was injected directly into the femoral artery of cadaver legs to provide the proper contrast enhancement. First, the entire knee joint was analysed with micro-CT, then to increase the applicable resolution the lateral and medial menisci were excised and investigated with a maximum resolution of up to 4 μm. The resulting micro-CT datasets were analysed both qualitatively and quantitatively. Key parameters of the vascular network, such as vascular volume fraction, vessel radius, vessel length density, and tortuosity, were separately determined for the lateral and medial meniscus, and their four circumferential zones defined by Cooper.

In accordance with previous literature, the quantitative micro-CT data confirm a decrease in vascular volume fraction along the meniscal zones. The highest concentration of blood vessels was measured in the meniscocapsular region 0, which is characterized by vascular segments with a significantly larger average radius. Furthermore, the highest vessel length density observed in zone 0 suggests a more rapid delivery of oxygen and nutrients compared to other regions. Vascular tortuosity was detected in all circumferential regions, indicating the occurrence of vascular remodelling in all tissue areas.

In conclusion, micro-CT is a non-invasive imaging technique that allows for the visualization of the internal structure of an object in three dimensions. These advanced 3D vascular analyses have the potential to establish new surgical approaches that rely on the healing potential of specific areas of the meniscus.

Acknowledgements: The authors acknowledge R. Hlushchuk, S. Halm, and O. Khoma from the University of Bern for their help with contrast agent perfusions.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 46 - 46
2 Jan 2024
Wehrle E
Full Access

Fracture healing is a spatially controlled process involving crosstalk of multiple tissues. To precisely capture and understand molecular mechanism underlying impaired healing, there is a need to integrate spatially-resolved molecular analyses into preclinical fracture healing models. I will present our recent data obtained by spatial transcriptomics of musculoskeletal samples from fracture healing studies in mice. Subsequently, I will show how spatial transcriptomics can be integrated into multimodal approaches in preclinical fracture healing models. In combination with established in vivo imaging and emerging omics techniques, spatially-resolved analyses have the potential to elucidate the molecular mechanisms underlying impaired healing with optimization of treatments.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 106 - 106
2 Jan 2024
Shin H
Full Access

Recently, technologies to culture one or more cell types in three dimensions have attracted a great deal of attention in tissue engineering. Particularly, the improved viability, self-renewal capacity, and differentiation potential have been reported for stem cell spheroids. However, it is crucial to modulate spheroid functions with instructive signals to use multi-cellular spheroids in tissue engineering. We have been developing ECM-mimicking fibrous materials decorated with cell-instructive cues, which were incorporated within 3D stem cell spheroids to fine-tune their functions as modular building blocks for bottom-up tissue-engineering applications. In particular, we created composite spheroids of human adipose-derived stem cells (hADSCs) incorporating nanofibers coated with instructive signal of either transforming growth factor-β3 or bone morphogenetic growth factor-2 for chondrogenesis or osteogenesis of stem cells, respectively. The bilayer structure of osteochondral tissue was subsequently mimicked by cultivating each type of spheroid inside 3D-printed construct. The in vitro chondrogenic or osteogenic differentiation of hADSCs within the biphasic construct under general media was locally regulated by each inductive component. More importantly, hADSCs from each spheroid proliferated and sprouted to form the integrated tissue with interface of bone and cartilage tissue. This approach may be applied to engineer complex tissue with hierarchically organized structure.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 10 - 10
2 Jan 2024
Tian X Vater C Raina DB Findeisen L Matuszewski L Tägil M Lidgren L Schaser K Disch A Zwingenberger S
Full Access

Although bone morphogenetic protein 2 (BMP-2) has been FDA-approved for spinal fusion for decades, its disadvantages of promoting osteoclast-based bone resorption and suboptimal carrier (absorbable collagen sponge) leading to premature release of the protein limit its clinical applications. Our recent study showed an excellent effect on bone regeneration when BMP-2 and zoledronic acid (ZA) were co-delivered based on a calcium sulphate/hydroxyapatite (CaS/HA) scaffold in a rat critical-size femoral defect model. Therefore, the aim of this study was to evaluate whether local application of BMP-2 and ZA released from a CaS/HA scaffold is favorable for spinal fusion. We hypothesized that CaS/HA mediated controlled co-delivery of rhBMP-2 and ZA could show an improved effect in spinal fusion over BMP-2 alone. 120, 8-week-old male Wistar rats (protocol no. 25-5131/474/38) were randomly divided into six groups in this study (CaS/HA, CaS/HA + BMP-2, CaS/HA + systemic ZA, CaS/HA + local ZA, CaS/HA + BMP-2 + systemic ZA, CaS/HA + BMP-2 + local ZA). A posterolateral spinal fusion at L4 to L5 was performed bilaterally by implanting group-dependent scaffolds. At 3 weeks and 6 weeks, 10 animals per group were euthanized for µCT, histological staining, or mechanical testing. µCT and histological results showed that the CaS/HA + BMP-2 + local ZA group significantly promoted bone regeneration than other treated groups. Biomechanical testing showed breaking force in CaS/HA + BMP + local ZA group was significantly higher than other groups at 6 weeks. In conclusion, the CaS/HA-based biomaterial functionalized with bioactive molecules rhBMP-2 and ZA enhanced bone formation and concomitant spinal fusion outcome

Acknowledgements: Many thanks to Ulrike Heide, Anna-Maria Placht (assistance with surgeries) as well as Suzanne Manthey & Annett Wenke (histology).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 75 - 75
2 Jan 2024
Silva J Udangawa R Cabral JS Ferreira F Linhardt R
Full Access

Electrospinning is an advantageous technique for cartilage tissue engineering (CTE) applications due to its ability to produce nanofibers recapitulating the size and alignment of the collagen fibers present within the articular cartilage superficial zone. Moreover, coaxial electrospinning allows the fabrication of core-shell fibers able to encapsulate and release bioactive molecules in a sustained manner. Kartogenin (KTG) is a small heterocyclic molecule, which was demonstrated to promote the chondrogenic differentiation of human bone marrow-derived mesenchymal stem/stromal cells(hBMSCs)[1].

In this work, we developed and evaluated the biological performance of core-shell poly(glycerol sebacate)(PGS)/poly(caprolactone)(PCL) aligned nanofibers (core:PGS/shell:PCL) mimicking the native articular cartilage extracellular matrix(ECM) and able to promote the sustained release of the chondroinductive drug KTG[2].

The produced coaxial aligned PGS/PCL scaffolds were characterized in terms of their structure and fiber diameter, chemical composition, thermal properties, mechanical performance under tensile testing and in vitro degradation kinetics, in comparison to monoaxial PCL aligned fibers and respective non-aligned controls. KTG was incorporated into the core PGS solution to generate core-shell PGS-KTG/PCL nanofibers and its release kinetics was studied by HPLC analysis. KTG-loaded electrospun aligned scaffolds capacity to promote hBMSCs chondrogenic differentiation was evaluated by assessing cell proliferation, typical cartilage-ECM production (sulfated glycosaminiglycans(sGAG)) and chondrogenic marker genes expression in comparison to non-loaded controls. All the scaffolds fabricated showed average fiber diameters within the nanometer-scale and the core-shell structure of the fibers was clearly confirmed by TEM. The coaxial PGS-KTG/PCL nanofibers evidenced a more sustained drug release over 21 days. Remarkably, in the absence of the chondrogenic cytokine TGF-β3, KTG-loaded nanofibers promoted significantly the proliferation and chondrogenic differentiation of hBMSCs, as suggested by the increased cell numbers, higher sGAG amounts and up-regulation of the chondrogenic genes COL2A1, Sox9, ACAN and PRG4 expression. Overall, our results highlight the potential of core-shell PGS-KTG/PCL aligned nanofibers for the development of novel MSC-based CTE strategies.

Acknowledgements: The authors thank FCT for funding through the project InSilico4OCReg (PTDC/EME-SIS/0838/2021) and to institutions iBB (UID/BIO/04565/2020) and Associate Laboratory I4HB (LA/P/0140/2020).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 77 - 77
2 Jan 2024
Khiabani A Kovrlija I Locs J Loca D Gasik M
Full Access

Titanium alloys are one of the most used for orthopaedic implants and the fabrication of them by 3D printing technology is a raising technology, which could effectively resolve existing challenges. Surface modification of Ti surfaces is often necessary to improve biocorrosion resistance, especially in inflammatory conditions. Such modification can be made by coatings based on hydrogels, like alginate (Alg) - a naturally occurring anionic polymer. The properties of the hydrogel can be further enhanced with calcium phosphates like octacalcium phosphate (OCP) as a precursor of biologically formed hydroxyapatite. Formed Alg-OCP matrices have a high potential in wound healing, delivery of bioactive agents etc. but their effect on 3D printed Ti alloys performance was not well known.

In this work, Alg-OCP coated 3D printed samples were studied with electrochemical measurements and revealed significant variations of corrosion resistance vs. composition of the coating. The potentiodynamic polarization test showed that the Alg-OCP-coated samples had lower corrosion current density than simple Alg-coated samples. Electrochemical impedance spectroscopy indicated that OCP incorporated hydrogels had also a high value of the Bode modulus and phase angle. Hence Alg-OCP hydrogels could be highly beneficial in protecting 3D printed Ti alloys especially when the host conditions for the implant placement are inflammatory.

AcThis work was supported by the European Union Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie Actions GA860462 (PREMUROSA). The authors also acknowledge the access to the infrastructure and expertise of the BBCE – Baltic Biomaterials Centre of Excellence (European Union Horizon 2020 programme under GA857287).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 78 - 78
2 Jan 2024
Larrañaga-Jaurrieta G Abarrategui A Camarero-Espinosa S
Full Access

In the native articular cartilage microenvironment, chondrocytes are constantly subjected to dynamic physical stimuli that maintains tissue homeostasis. They produce extra cellular matrix (ECM) components such as collagens (type II mainly, 50-75%), proteoglycans (10-30%) and other type of proteins1 . While collagen offers a large resistance in tension, proteoglycans are the responsible of the viscoelastic response under compression due to the negative charge they confer to the ECM allowing it to entrap a large amount of interstitial fluid. In pathologic states (e.g. osteoarthritis), this ECM is degenerated and the negative charge becomes unbalanced, losing the chondroprotective properties and resulting on an overloaded chondrocytes that further degenerate the matrix.

Low-Intensity Pulsed Ultrasound Stimulation (LIPUS) has been used to generate acoustic (pressure) waves that create bubbles that collapse with cells, inducing a stimulus that can modulate cell response2. This mechanical stimulation promotes the expression of type II collagen, type X collagen, aggrecan and TGF-β, appearing as a great strategy to regenerate cartilage. However, current strategies make use of extrinsic forces to stimulate cartilage formation overlooking the physico-chemical properties of the degenerated cartilage, resulting in an excessive load-transfer to chondrocytes and the consequent hypertrophy and degeneration.

Here, interpenetrated networks (IPNs) with different compositions were created using methacrylated gelatin (GelMA), to mimic the collagen, and alginate functionalized with tyramine (Alg-tyr) to mimic glycosaminoglycans and to introduce a negative charge in the model. Within the matrix chondrocytes where encapsulated and stimulated under different conditions to identify the ultrasound parameters that enhance tissue formation. Samples with and without stimulation were compared analysing the expression and deposition of collagen II, aggrecan, collagen X and TGF-β. The results suggested that the chondrogenic marker expression of the samples stimulated for 10 minutes per day for 28 days, was two times higher overall in all of the cases, which was correlated to the tissue formation detected.

Acknowledgments: The authors would like to thank the Basque Government for the “Predoctoral Training Program for Non-Doctoral Research Staff 2021-2022” (Grant ref.: PRE_2021_1_0403). This work was supported by the RETOS grant PID2020-114901RA-I00 of the Ministry of Science and Innovation (MICINN).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 15 - 15
2 Jan 2024
Costa B Alves P Fonseca D Campos F Monteiro AC Pereira R Costa F Gomes P Martínez-de-Tejada G Monteiro C Martins M
Full Access

Orthopedic Device-Related Infections (ODRIs) are a major medical challenge, particularly due to the involvement of biofilm-encased and multidrug-resistant bacteria. Current treatments, based on antibiotic administration, have proven to be ineffective. Consequently, there is a need for antibiotic-free alternatives. Antimicrobial peptides (AMPs) are a promising solution due to their broad-spectrum of activity, high efficacy at very low concentrations, and low propensity to induce resistance. We aim to develop a new AMP-based chitosan nanogel to be injected during orthopedic device implantation to prevent ODRIs. Chitosan was functionalized with norbornenes (NorChit) through the reaction with carbic anhydride and then, a cysteine-modified AMP, Dhvar5, a peptide with potent antibacterial activity, even against methicillin-resistant Staphylococcus aureus (MRSA), was covalently conjugated to NorChit (NorChit- Dhvar5), through a thiol-norbornene photoclick chemistry (UV= 365 nm). For NorChit-Dhvar5 nanogels production, the NorChit-Dhvar5 solution (0.15% w/v) and Milli-Q water were injected separately into microfluidic system. The nanogels were characterized regarding size, concentration, and shape, using Transmission Electron Microscopy (TEM), Nanoparticle Tracking Analysis (NTA) and Dynamic light scattering (DLS). The nanogels antibacterial properties were assessed in Phosphate Buffer (PBS) for 6 h, against four relevant microorganisms (Pseudomonas aeruginosa, S. aureus and MRSA, and in Muller- Hinton Broth (MHB), 50% (v/v) in PBS, supplemented with human plasma (1% (v/v)), for 6 and 24 h against MRSA. The obtained NorChit-Dhvar5 nanogels, presented a round-shaped and ∼100 nm. NorChit- Dhvar5 nanogels in a concentration of 1010 nanogels/mL in PBS were capable of reducing the initial inoculum of P. aeruginosa by 99%, S. aureus by 99%, and MRSA by 90%. These results were corroborated by a 99% MRSA reduction, after 24 h in medium. Furthermore, NorChit-Dhvar5 nanogels do not demonstrate signs of cytotoxicity against MC3T3-E1 cells (a pre-osteoblast cell line) after 14 days, having high potential to prevent antibiotic-resistant infection in the context of ODRIs.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 81 - 81
2 Jan 2024
van Griensven M
Full Access

Bone regeneration is pivotal for the healing of fractures. In case this process is disturbed a non-union can occur. This can be induced by environmental factors such as smoking, overloading etc. Co-morbidities such as diabetes, osteoporosis etc. may be more intrinsic factors besides other disturbances in the process. Those pathways negatively influence the bone regeneration process. Several intrinsic signal transduction pathways (WNT, BMP etc.) can be affected. Furthermore, on the transcriptional level, important mRNA expression can be obstructed by deregulated miRNA levels. For instance, several miRNAs have been shown to be upregulated during osteoporotic fractures. They are detrimental for osteogenesis as they block bone formation and accelerate bone resorption. Modulating those miRNAs may revert the physiological homeostasis. Indeed, physiological fracture healing has a typical miRNA signature. Besides using molecular pathways for possible treatment of non-union fractures, providing osteogenic cells is another solution. In 5 clinical cases with non-union fractures with defects larger than 10 cm, successful administration of a 3D printed PCL-TCP scaffold with autologous bone marrow aspirate concentrate and a modulator of the pathogenetic pathway has been achieved. All patients recovered well and showed a complete union of their fractures within one year after start of the regenerative treatment.

Thus, non-union fractures are a diverse entity. Nevertheless, there seem to be common pathogenetic disturbances. Those can be counteracted at several levels from molecular to cell. Compositions of those may be the best option for future therapies. They can also be used in a more personalized fashion in case more specific measurements such as miRNA signature and stem cell activity are applied.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 128 - 128
2 Jan 2024
Ackerman J
Full Access

Tendon injuries present a major clinical challenge, as they necessitate surgical intervention and are prone to fibrotic progression. Despite advances in physical therapy and surgical technique, tendons fail to return to full native functioning, underlining the need for a biological therapeutic to improve tendon healing. Myofibroblasts are activated fibroblasts that participate in the proliferative and remodeling phases of wound healing, and while these matrix-producing cells are essential for proper healing, they are also linked to fibrotic initiation. A subset of tenocytes has been shown to give rise to the myofibroblast fate, and potentially contribute to fibrotic tendon healing. A viable anti-fibrotic therapy in other tissues has been reprogramming the fibroblast-myofibroblast differentiation route, avoiding a more pro-fibrotic myofibroblast phenotype. Thus, defining the molecular programs that underlie both physiological and pathological tendon healing is critical for the development of potential pharmacologic treatments. Towards that end, we have taken advantage of spatial transcriptomics, using the tenocyte marker Scleraxis as a tool, and have outlined three major spatiotemporally distinct tenocyte differentiation trajectories (synthetic, proliferative, and reactive) following acute tendon injury in mouse FDL. We have further outlined key transcriptional controls that may be manipulated to alter the differentiation process and influence the resulting myofibroblast phenotype, thereby promoting regenerative tendon healing.