Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 14 - 14
1 May 2012
Accardi M Dini D Lim N Yamamoto K Cann P
Full Access

INTRODUCTION

Osteoarthritis (OA) can be artificially simulated ex vivo on healthy articular cartilage (AC) samples by use of proteolytic enzymes. In this article we will present preliminary analyses of the physical degradation of AC when subjected to alternating mechanical stresses. Since AC damage due to OA is believed to be mechanically induced, the first step towards the realisation of an improved understanding of degenerative behaviour of AC under physiological loading conditions is to perform ex vivo tests which mimic such conditions at best.

METHODS

Porcine AC was subjected to biochemical stimulation or left as native AC. Biochemical degradation was performed using combinations of trypsin and Matrix Metalloproteinases (MMPs) to induce the loss of proteoglycan and collagen. A comparison of the biochemical and mechanical properties, topography and difference in response to mechanical damage between the digested AC and healthy AC was made using White Light Interferometry (WLI), Atomic Force Microscopy (AFM) and mechanical testing. The mechanical damage was induced by subjecting AC to shear under physiological and non physiological conditions. The AC was mechanically tested in a Phosphate Buffered Saline (PBS) bath. After mechanical testing, biochemical analysis of the collagen and aggrecan content of the tissue and PBS present in the bath during the mechanical test was performed. Collagen content was determined by measurement of the amount of hydroxyproline (HPRO), and aggrecan content by the amount of glycosaminoglycans (GAG). The mechanical test was either performed on healthy (native) AC or on AC which had first been digested.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 438 - 438
1 Nov 2011
Hamada D Okubo Y Yamamoto K Mori S Ikeuchi K Tomita N
Full Access

It have been reported that the wear volume of vitamin E-containing UHMWPE tested with a knee joint simulator was approximately 30% lower than that of virgin UHMWPE at 5 million cycles. However, the wear resistance mechanism of vitamin E-containing UHMWPE has not yet been clarified. The present study examines the effects of the addition of vitamin E on the frictional properties of ultra-high molecular weight polyethylene (UHMWPE) under several different load and serum conditions.

Friction tests were carried out using a computer-controlled pin-on-disk friction test apparatus. The UHMWPE pin was mounted vertically at the tip of the leaf spring and linear reciprocating sliding motion for 2,000 cycles with an amplitude of 1 mm and a frequency of 1 Hz, was applied under 3 MPa or 30 MPa loading against Co-28Cr-6Mo alloy disk. The lubricant bath was filled with 5 ml of ultrapure water, fresh serum, post-friction (PF) serum or diluted-PF (DPF) which were kept at a temperature of 37°C. The friction force between the UHMWPE pin and the Co-28Cr-6Mo alloy disk was calculated from the displacement of the leaf spring during the sliding motion.

Vitamin E-containing UHMWPE showed a significantly higher friction force than that of virgin UHMWPE in fresh serum lubricant at 30 MPa loading, while there were little differences in either ultrapure water or PF serum or DPF serum. And vitamin E-containing UHMWPE tends to exhibit a lower dynamic friction force within the first few hundred cycles in the case of all serum lubricants at 30 MPa loading. These results suggest that some interaction between the UHMWPE surface and the native conformation proteins was specifically affected by the addition of vitamin E and that some weeping of vitamin E might occur at early stage of sliding. Our results also suggest the importance of the conformational changes of serum proteins for the wear testing.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1194 - 1200
1 Sep 2011
Akiyama H Yamamoto K Tsukanaka M Kawanabe K Otsuka H So K Goto K Nakamura T

We retrospectively reviewed 40 hips in 36 patients who had undergone acetabular reconstruction using a titanium Kerboull-type acetabular reinforcement device with bone allografts between May 2001 and April 2006. Impacted bone allografts were used for the management of American Academy of Orthopaedic Surgeons Type II defects in 17 hips, and bulk bone allografts together with impacted allografts were used for the management of Type III defects in 23 hips. A total of five hips showed radiological failure at a mean follow-up of 6.7 years (4.5 to 9.3), two of which were infected. The mean pre-operative Merle d’Aubigné score was 10 (5 to 15) vs 13.6 (9 to 18) at the latest follow-up. The Kaplan-Meier survival rate at ten years, calculated using radiological failure or revision of the acetabular component for any reason as the endpoint, was 87% (95% confidence interval 76.3 to 97.7). A separate experimental analysis of the mechanical properties of the device and the load-displacement properties of bone grafts showed that a structurally hard allograft resected from femoral heads of patients with osteoarthritis should be preferentially used in any type of defect. If impacted bone allografts were used, a bone graft thickness of < 25 mm was acceptable in Type II defects.

This clinical study indicates that revision total hip replacement using the Kerboull-type acetabular reinforcement device with bone allografts yielded satisfactory mid-term results.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 146 - 146
1 Mar 2010
Kubo K Clarke I Lazennec J Catonne Y Smith E Halim C Yamamoto K Donaldson T
Full Access

While there are many variation laboratory and clinical studies using metal-on-metal (MOM) bearings after introduction of the 28mm MOM THR in 1988, the mapping of wear phenomena in such retrieval cases has been mimimal. In laboratory study, 28mm MOM bearing’s wear-rate was low with “run-in” and “steady-state” than large diameter MOM without theory of fluid-filum lubrication. In clinical results were not superior to the same way of laboratory study. We present a detailed analysis of 33 retrieved MOM hip bearings with 1–11 years follow-up,

We compiled 33 retrieval cases (MetasulTM: Zimmer/CenterPulse Inc., Austin, TX) including clinical information, ion concentrations from ball diameters, cup designs and stripe wear damage. The bearing surfaces were mapped using reflected light microscope (RLM), white light interferometer (Zygo Newview 600, Zygo.) and SEM(XL-30 FEG). Wear maps were constructed according to types of surface wear identified.

Patients ranged from 36 to 76 years of age (Means: 56.9 years); 54% were males. Main causes for revision were progressive radiographic lines around the cups, osteolysis and pain. The 28mm ball diameter was used in 86% of cases (largest = 52mm ball). The CoCr liner incorporated a polyethylene adaptor in 75% of cases. Cup diameter > 50mm was present in 75% of cases. Eight femoral stems were recovered and all showed major impingement marks around the neck and five also had a metallosis (Mode-4A). Stripe wear was evident on 71% of CoCr balls with medial stripes twice as common as lateral. Stripe wear was identified in 25% of CoCr liners and extended 25–160° circumference around the liners. Clear liner rim damage was present in 10 (30%) and 3 demostrated severe damage of polyethelene adaptors.

There are many limitations to such retrieval studies. These data are biased to cases that failed due to hip pain, radiographic signs of progressive osteolysis and some with high levels of metal ions. There was also the bias of having predominantly a CoCr sandwich design (polyethylene adaptor in 75% of cases). In early 1980s, the thin walled UHMWPE cup was introduced and used larger diameter balls for decreased risk of dislocation. However, unfortunally these big-ball cups produced significant PE wear debris, and diameter trends were returned to the Chanley’s small-ball paradigm again. In the same time (late of 1980’s), these second-generation MOM (28,32mm) was introduced for low wear characteristics alternate THR bearings, with sacrificing of joint stability and motion range. However, use of the small ball added well-known risks of impingement, subluxation and dislocation with rigid cups. In this study, using the ‘damage modes’ from McKellop, normal mode-1 wear occurred in only 14% of cases whereas modes 2–4 had an incidence approaching 30% each and signs of cup impingement were evident in 64% of cases. Thus summarizing MOM wear phenomena in “small” 28mm sandwich cup designs, there was retrieval evidence showing that damage modes 2–4 likely placed these patients at risk for adverse wear effects.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 103 - 103
1 Mar 2010
Kubo K Clarke I Williams P Sorimachi T Halim T Gustafson A Yamamoto K
Full Access

Wear in polyethylene liners appears to be exacerbated by 3rd-body abrasion effects with the CoCr ball combinations used for total hip replacements. This has implications for various wear modes encountered in patients. Yet clinical and laboratory studies have offered weak and sometimes contradictory wear relationships with respect to crosslinking, ball diameter and roughness, and 3rd-body wear effects. Our hip simulator model investigated the effect of severe wear challenges by 3rd-body cement particles, using large diameter CoCr and alumina balls, with highly-crosslinked polyethylene liners (HXPE) irradiated to 75kGy compared to contemporary controls (CXPE 35kGy).

The polyethylene liners were gamma-irradiated to 35/75kGy under N2 (CXPE/HXPE). We used 32 and 44mm CoCr balls (ENCORE, Austin, TX) and 44mm alumina-ceramic (Biolox-forte, CeramTecAG) as ‘scratch-resistant’ standard of comparison. We compared 5 bearings pairs with different roughness characteristics using both new and pre-worn polyethylene liners. A 12-station orbital hip simulator with a physiological load profile (0.2kN–3kN load, frequency 1Hz) with cups mounted in “Inverted- position”. Diluted bovine serum (Hyclone Inc., Logan, UT) was used as lubricant (20mg/ml protein, 400ml volume). In phase I, all cups were run in standard (‘clean’) lubricant for 1.5 million cycles (1.5Mc). In phase II, the liners were run in a PMMA slurry of serum (5mg/ml) for 2Mc. In phase III, implants were run ‘clean’ for 1.5Mc. Wear-rate was measured each 0.25Mc event, and surface roughness measured by SEM (XL-30FEG) and white light interferometry (Newview600, Zygo) every 0.5Mc.

In phase I, Wear withnew CXPE and HXPE liners averaged 182mm3/Mc and 30mm3/Mc. Thus the HXPE liners averaged a 6.0-fold wear reduction compared to controls. Compared to new liners, the pre-worn CXPE and HXPE liners showed 10% and 25%, greater wear respectively. Here it was noted that CoCr balls maintained similar roughness (Sa:8–12nm). And alumina balls showed small, gradual increase (Sa: 2 to 2.5nm). The HXPE maintained a superior finish to CXPE controls. Roughness revealed a gradual decrease with time, pre-worn CXPE from 0.28 to 0.15um and pre-worn HXPE from 0.18 to 0.04um (Sa). In contrast, new HXPE showed a dramatic smoothing (0.8 to 0.1um) 92.8% decreased in first 0.5Mc. These effects have not been previously quantified. In phase II with abrasive mode, the liner wear-rates increased dramatically by 6 and 80-fold for CXPE and HXPE, respectively. These data confirmed that HXPE was sensitive to ‘severe’ wear against CoCr and alumina balls. In phase III, the polyethylene roughness dropped by > 90% and wear decreased to phase-I values. The wear-ratio was now 2:1 for CXPE:HXPE as predicted by the ‘diameter’ and ‘crosslinking’ algorithms.

It was clear that surface roughness was not a confounding factorfor either the CoCr or alumina balls. It was the polyethylene surface roughness that appeared to influence wear rates. Our analysis showed that there was a transient due to patches of abrasive cement transferring onto CoCr ball surfaces. Overall the actual roughness of the CoCr balls did not change and was therefore not a factor in increased polyethylene wear.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 24 - 25
1 Jan 2003
Yamamoto K Williams P Kawanabe K Good V Clarke I Masaoka T Imakiire A Oonishi H
Full Access

The objective of this study was to compare the wear mode of 100 Mrad PE cups run in a hip simulator to retrieved 100 Mrad PE cups, and to evaluate the efficacy of the PE wear model.

15 In-vitro PE cups: 3 each 0,2.5.50,100 and 150 Mrad (9 channel hip simulator, 6.2 million cycle duration, physiological load profile by Paul, 2000N maximum load at 1Hz using 30% bovine serum). 5 Retrieved PE cups: three SOM cups (Mizuho Medical Instrument Co., COP alloy 28 mm head)-0 Mrad after 8 years of clinical use, two 100 Mrad cups after 15 years of clinical use, two T28 PE 2.5 Mrad cups (Zimmer): 18 years and 13 years of clinical use. The cups were examined using a SEM (Philip XL30 FEG) for wear scar locations and PE wear-topography.

Original machine marks were observed in the weight-bearing areas of the highly cross-linked in-vitro PE. No machine marks were observed for the 0 and 2.5 Mrad in-vitro cups and none were seen in any of the retrieved cups. The formation of more nodules and fibrils in the 0Mrad cups compared to the extensivley cross-linked cups (in-vitro and retrieved) was striking. The frequency of occurrence and length of the fibrils and nodules was dependent on the dose of gamma irradiation. More ripples were formed in the 2.5 Mrad and higher cups compared to the non-irradiated cups (in-vitro and retrieved). The in-vitro cups formed more ripples than the retrieved cups. In general, the SEM features for in-vitro Mrad cups appeared similar to those of the retrieved Mrad cups.

The in-vitro Mrad cups accurately reflected the conditions of the artificial joint in living body. Therefore, comparisons of retrieved PE cups with simulator PE cups appeared to be a very powerful research tool.

(2) SEM observation demonstrated far less wear damage in the extensively cross-linked cups than in the non-extensively cross-linked PE. Thus the extensive cross-linked PE cups appeared to be a significant improvement over conventional PE cups in terms of wear resistance.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 223 - 223
1 Nov 2002
Koshino T Mochida Y Yamamoto K Hirakawa K Saito T
Full Access

Wear of UHMWPE and Clinical results of bioceramic total knee replacement have not been well reported yet. The ultra high molecular weight polyethylene surfaces of the tibial components were examined in 3 retrieved knees with non-infectious loosening, and were almost normal in appearance with only minor scratch lines 33 to 59 months after the initial arthroplasty. Bioceramic total knee arthroplasty was concluded to show satisfactory results except for the initial several cases done with rather poor surgical techniques. The wear of UHMWPE surface in ceramic knee was observed to be much less and milder than that of metal prosthesis.

Total knee arthroplasty (cementless) using Yokohama Medical Ceramic Knee was performed in 64 knees and, excluding 4 knees with the prostheses retrieved, was evaluated in 60 knees of 47 patients.

There ware 1 man (1 knee) and 31 women (44 knees) who had rheumatoid arthritis with a mean age of 56.8±11.9 years, and 2 men (2 knees) and 11 women (13 knees) with osteoarthritis with a mean age of 70.6±6.9 years. The mean follow-up duration was 48.1±9.2 months ranging from 33 to 60 months.

The maximum knee flexion was 115±24 degrees before and 104±20 degrees after arthroplasty in the rheumatoid group, and 107±40 degrees before and 101±26 degrees after arthroplasty in the osteoarthritis group.

Clinical evaluation using The Hospital for Special Surgery Knee Criteria showed 7 knees as Excellent, 34 as Good, 7 as Fair and 12 as Poor after surgery. Complications consisted of infection (1 case), tibial plateau fracture (1), avulsion fracture of the tibial tuberosity (1) and patellar dislocation (1)


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 460 - 464
1 May 1995
Teshima R Otsuka T Takasu N Yamagata N Yamamoto K

We studied the most superficial layer of macroscopically normal articular cartilage obtained from human femoral heads, using polarising microscopy and SEM. The most superficial layer, 4 to 8 microns thick, was acellular consisting of collagen fibrils. This layer could be peeled away as a thin film, with no broken collagen fibrils on its inferior surface or on the surface of subjacent cartilage layers. The orientation and diameter of collagen fibrils were different on these two surfaces. Our findings suggest that the most superficial layer is an independent one which is only loosely connected to the fibrous structure in the layer deep to it.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 829 - 831
1 Nov 1988
Kawai H Yamamoto K

Delayed union or non-union of the scaphoid was treated by a bone graft on a pronator quadratus pedicle in eight cases. This produced earlier union than the Russe procedure. The procedure is simple and is recommended for old un-united scaphoid fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 287 - 292
1 Mar 1988
Kawai H Yamamoto K Yamamoto T Tada K Kaga K

Excision of the lunate was performed for 18 patients with Kienbock's disease; 14 were followed up for an average of almost 12 years. Carpal collapse progressed with time, but rearrangement of the remaining carpal bones preserved a satisfactory range of movement and grip strength. Degenerative changes were not severe. All the patients had relief of pain, were able to carry out their normal activities, and all but two could perform strenuous activities.