header advert
Results 21 - 40 of 60
Results per page:
Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 98 - 98
1 May 2011
Kuzyk P Zdero R Shah S Olsen M Higgins G Waddell J Schemitsch E
Full Access

Minimizing tip-apex distance has been shown to reduce clinical failure of sliding hip screws used to fix peritro-chanteric fractures. The purpose of this study was to determine if such a relationship exists for the position of the lag screw in the femoral head using a cephalomedullary device.

Methods: Thirty intact synthetic femur specimens (Model #3406, Pacific Research Laboratories, Vashon, WA) were potted into cement blocks distally for testing on an Instron 8874 (Instron, Canton, MA). A long cephalomedullary nail (Long Gamma 3 Nail, Stryker, Mahwah, NJ) was inserted into each of the femurs. An unstable four-part fracture was created, anatomically reduced, and repaired using one of 5 lag screw placements in the femoral head:

Superior (N=6),

Inferior (N=6),

Anterior (N=6),

Posterior (N=6),

Central (N=6).

Mechanical tests were repeated for axial, lateral and torsional stiffness. All specimens were radiographed in the anterioposterior and lateral planes and tip-apex (TAD) distance was calculated. A calcar referenced tip-apex distance (CalTAD) was also calculated.

ANOVA was used to compare means of the five treatment groups. Linear regression analysis was used to compare axial, lateral and torsional stiffness (dependant variables) to both TAD and CalTAD (independent variables).

Results: ANOVA testing proved that the mean axial (p< 0.01) and torsional stiffness (p< 0.01) between the 5 groups was significantly different, but lateral stiffness was not statistically different (p=0.494). Post hoc analysis showed that the inferior lag screw position provided significantly higher mean axial stiffness (568.14±66.9N/ mm) than superior (428.0±45.6N/mm; p< 0.01), anterior (443.2±45.4N/mm; p=0.02) and posterior (456.7±69.3N/ mm; p=0.04) lag screw positions. There was no significant difference in mean axial stiffness between inferior (568.14±66.9N/mm) and central (525.4±81.7N/mm) lag screw positions (p=0.77). Post hoc analysis revealed significantly less mean torsional stiffness for the superior lag screw position compared to other lag screw positions (p< 0.01 all 4 pairings). There were no significant correlations between TAD and axial (r=−0.33, p=0.08), lateral (r=−0.22, p=0.24) or torsional (r=0.08, p=0.69) stiffness. There were significant correlations between CalTAD and axial (r=−0.66, p< 0.01), lateral (r=−0.38, p=0.04) and torsional (r=−0.38, p=0.04) stiffness.

Discussion: Our results suggest that placement of the lag screw inferiorly in the femoral head when using a cephalomedullary nail to treat an unstable peritrochanteric fracture results in the stiffest construct in axial and torsional biomechanical testing. A simple radiographic measurement, CalTAD, provides an intraoperative method of determining optimal cephalomedullary nail lag screw position to achieve greatest construct stiffness.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 524 - 524
1 Oct 2010
Lewis P Bogoch E Olsen M Schemitsch E Waddell J
Full Access

The use of metal on polyethylene articulations was a key development in establishing total hip arthroplasty as a successful and reproducible treatment for end stage osteoarthritis. In order to ensure implant durability in relatively younger populations, there is a need for alternative, wear resistant bearing surfaces. Oxidized Zirconium (Oxinium, Smith & Nephew, Inc., Memphis, TN) is a relatively new material that features an oxidized ceramic surface chemically bonded to a tough metallic substrate. This material has demonstrated the reduced polyethylene wear characteristics of a ceramic, without the increased risk of implant fracture. The purpose of the current investigation was to assess early clinical outcomes following primary total hip arthroplasty with Oxinium versus Cobalt Chrome femoral heads.

One-hundred primary THA procedures were prospectively performed in 100 patients. There were 52 males and 48 females. Using a process of sealed envelope randomization, patients were divided into 2 groups. Group 1 consisted of fifty patients, each receiving primary THA implants with an Oxinium femoral head (OX). The mean age of each patient was 51 years (SD 10.8, Range 22–74) with 26 males and 24 females. Group 2 also consisted of 50 patients. Within this group again each patient received primary THA implants however with a cobalt-chrome femoral head (CC). Demographics were similar with mean age 51 years (SD 11.0, Range 19–76) and again 26 males and 24 females.

The current study reports clinical outcome measures for both the OX and CC groups at a minimum follow-up of 2 years postoperatively. At the time of latest follow-up, stem survival for both groups was 98%. There was a significant improvement in all clinical outcome scores between preoperative and 2 year postoperative time periods for both bearing groups (p< 0.003). There were no significant differences between bearing groups for any of the clinical outcome scores at final follow-up (p> 0.159). Mean Harris Hip Scores at 2 years postoperatively were 92 and 92.5 for OX and CC, respectively (range; 65–100 OX, 60–100 CC). For SF-12, both the Physical Component Summary Scale (PCS) and the Mental Component Summary Scale (MCS) are reported. Mean PCS scores at final follow-up were 45.2 and 49.21 for OX and CC (range; 27.1–56.7 OX, 26.3–61.8 CC). Mean MCS scores were 53.8 and 52.57 for OX and CC (range; 39.2–65.5 OX, 34.3–64 CC). Mean final WOMAC scores are reported as 84.9 and 87 for OX and CC, respectively.

The current data suggest that total hip arthroplasty utilizing Oxinium femoral heads is safe and effective. Additional follow-up of the current cohort will be performed in order to fully assess mid- to long-term clinical outcomes.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 353 - 353
1 May 2010
Keast-Butler O Lutz M Lash N Escott B Waddell J Schemitsch E
Full Access

Introduction: This study aimed to determine the accuracy of computer navigation in simulated fixation of femoral neck and supracondylar femoral fractures using different sizes of guidewires and drills from commercially available cannulated screw systems.

Methods: Simulated fracture fixation was performed with 2.5mm, 2.8mm and 3.2mm threaded guidewires and 3.2mm and 5mm drill bits using 20 4th generation synthetic femurs. The drill or guide wire was inserted in the synthetic femurs, using fluoroscopy based computer navigation (24 drills/guidewires in each group). Pre and postoperative fluoroscopy images were acquired with the C-arm and synthetic bone in the same orientations. Virtual and real wire/drill positions were compared, and errors calculated for each diameter of drill/guidewire (sum AP + Lateral error (mm)). Errors were compared using a general linear model with Tukey adjustment for multiple comparisons. Statistical significance at a two-tailed p-value < 0.05.

Results: The mean error for the 5.0mm drill (3.20mm) was significantly less than all the threaded wires (p< 0.05). The mean error for the 3.2mm drill (5.68mm) was significantly less than the 2.5mm guidewire (9.27mm) p< 0.05, and less than the 2.8mm (8.19mm) and 3.2mm (7.14mm) threaded wires.

Discussion: For cannulated screws, the 3.2mm drill was the most accurate size tested. The most accurate drill, 5mm, would allow solid screw insertion. However, its large size may preclude screw repositioning, and unlike a cannulated screw, would not maintain fracture position whilst the screw was being inserted.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 95 - 95
1 Mar 2010
Lewis P Al-Belooshi A Olsen M Schemitsh E Waddell J
Full Access

Total hip replacement in the young active patient remains one of the major challenges in orthopaedics today. The use of ultra high molecular weight (UHMW) polyethylene acetabular liners is known to cause polyethylene wear related osteolysis, the major limiting factor in its use in the younger active patient. Modern alumina ceramic articulations have been developed in order to reduce wear and avoid polyethylene debris. This prospective randomized long-term study aims to compare the outcome between an alumina ceramic-on-ceramic (CC) articulation with a ceramic on UHMW polyethylene articulation (CP). In the younger active patient, is one option superior to the other with regard to patient satisfaction, osteolysis and implant longevity?

56 hips in 55 patients with mean age 42.2 (range 19–56) each received uncemented components (Wright Medical) and a 28mm alumina head with acetabular liner selected via sealed envelope randomization following anesthetic induction. Subsequent regular clinical and radiologic follow up measured patient outcome scores and noted any radiological changes.

26 CP hips and 30 CC hips were evaluated. One failure required revision in each group. Mean St Michael’s outcome score for each group with up to 10 years follow-up (median 8 years, range 1–10) was 22.8 and 22.9 respectively (p=0.057). Radiographs with a minimum 5 years post-operative follow-up were analyzed in 42 hips (23 CC and 19 CP). Radiolucency of all 3 acetabular zones was identified in one of the CP hips. There was no evidence of osteolysis or loosening identified in the remaining hips. The mean time of wear measurement for the CC group was 8.3 years (SD 1.3, Range 4.8–10.1 years) and for the CP group was 8.1 years (SD 0.9, Range 6.1–9.2 years)(p=0.471). Wear was identified in all but one of the CP replacements but only 12 of 23 CC articulations. The mean wear for the CC group was 0.14 mm (SD 0.16, Range 0–0.48 mm) and for the CP group was 0.89 mm (SD 0.6, Range 0–2.43 mm)(p< 0.001). Extrapolating the annual wear rate from these figures, the respective wear is 0.02mm for the CC group compared to 0.11mm per year for the CP group.

To our knowledge this is the first long term randomized trial comparing in vivo ceramic-on-ceramic with ceramic-on-conventional polyethylene hip articulations. Other than significantly greater wear in the polyethylene group there was no significant difference in long-term outcome scores between the two groups with up to 10 years of follow-up. The use of a ceramic-on-ceramic bearing is a safe and durable option in the young patient avoiding the concerns of active metal ions and osteolytic polyethylene debris. These patients remain under review.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 182 - 182
1 Mar 2010
Lutz M Keast-Butler O Ma J Escott B Schemitsch E Waddell J
Full Access

The effect of cup geometry in uncemented Total Hip Arthroplasty has not been investigated. We reviewed the radiological and clinical results of 527 primary total hip arthroplasties. We assessed the bone ingrowth potential of two geometric variations of an uncemented cup and compared hydroxyappetite and porous coated shells.

Patients undergoing primary hip arthroplasty between 1997 and 2004 were prospectively entered into an arthroplasty database. Patients were reviewed at 1,2,4,5,8 and 10 years post surgery. Three acetabular shell types were used. These included hemispherical cups with porous or hydroxyapatite coating, and cups with peripheral expansion with porous coating. Radiographs with minimum 1-year follow-up were examined in 542 cases, using digital templating software. Radiographs were assessed for signs of bone in-growth, lucent lines, migration and polyethylene wear. Survivorship analysis was performed using Kaplan-Meier analysis with 95% confidence intervals. Radiological findings and cup type were analysed using Fishers exact test.

Radiological evidence of bone ingrowth was seen in 82% of hemispherical cups, compared with 59% of peripherally expanded cups, which was significant (p,0.05). Bone ingrowth was not affected by the presence of HA coating. The most common diagnoses were osteoarthritis (67%) and avascular necrosis (12%). The mean age was 56 years. Survivorship with revision or impending revision for aseptic loosening was 95.6% at 7 years (95%CI 1.0134-0.8987). The 3 revisions and 1 impending revision for loosening were in patients with avascular necrosis (3) or previous acetabular and femoral osteotomies for DDH (1), with a mean age of 44 years.

Hemispherical shells have improved radiographic outcome in comparison with peripherally expanded components. At 7 years, clinical results are similar for both components.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 184 - 184
1 Mar 2010
Gallie P Davis E James S Waddell J Schemitsch E
Full Access

In perfroming hip resurfacing arthroplasty, concern has been expressed as to the proximity of the femoral neurovascular bundle during the anterior capsulotomy and the risk of damage during this maneuver. We therefore aimed to identify the proximity of the femoral nerve, artery and vein during an anterior capsulotomy done during a hip resurfacing procedure using the posterior approach.

A standard posterior approach was performed in 5 fresh frozen cadavic limbs. An anterior incision was then used to measure the distance of the femoral neurovascular structures to the anterior capsule. Measurements from the most posterior aspect of the vessels and nerves to the most anterior aspect of the anterior capsule were taken prior to hip dislocation. The femoral head was then dislocated, and measurements were made with the hip in both flexion and extension. In a separate group of eleven patients that underwent routine MR imaging of the hip, measurements were taken to assess the proximity of the anterior joint capsule to the femoral neurovascular bundle, by a specialist musculoskeletal radiologist who had no prior knowledge of the results obtained during the cadaveric dissection

All 5 cadaveric limbs were utilised. 3 were male and 2 were female. The average age was 72.4 years (range 56–84). The patients whom underwent routine MR imaging incorporated 6 males and 5 females with a mean age of 43.7 years (age range 18–64 years). There was no significant difference between the mean distances to the nerve (p=0.21), artery (p=0.21) or vein (p=0.65) between the MR and cadaveric groups. Prior to dislocation the femoral artery and vein were closest to the anterior capsule (mean distance of 21mm) and the femoral nerve was the furthest away (mean distance 25mm). Following dislocation there was a significant increase (25mm to 31mm) in mean distance to the femoral nerve when the superior capsule was cut with the hip in a flexed position (p=0.01) and to the femoral artery in flexion (increase mean distance from 21mm to 35mm) (p< 0.0001) and in extension(increase mean distance from 21mm to 31mm) (p=0.005). When the inferior capsule was cut, there was a significant increase (25mm to 31mm) in mean distance to the femoral nerve and femoral artery when the hip was dislocated and the capsule cut with the hip in flexion (increase mean distance from 21mm to 27mm) (p=0.019) and in extension(increase mean distance from 21mm to 28mm) (p=0.015).

This study suggests that the neurovascular structures are relatively well protected during an anterior capsulotomy performed during hip resurfacing. The procedure may be safer if the capsulotomy is performed with the hip dislocated and the hip in a flexed position while cutting the antero-superior aspect and in an extended position while cutting the antero-inferior aspect.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 249 - 249
1 May 2009
Davis E Gallie P Macgroarty K Schemitsch E Waddell J
Full Access

The purpose of this study was to assess the accuracy of clinical assessment compared to imageless computer navigation in determining the amount of fixed flexion during knee arthroplasty.

In fourteen cadaver knees, a medial para-patella approach was performed and the navigation anatomy registration process performed. The knees were held in various degrees of flexion with two crossed pins. The degree of flexion was first recorded on the computer and then on lateral radiographs. The cadaver knees were draped as for a knee arthroplasty and nine examiners (three arthroplasty surgeons, three fellows, and three residents) were asked to clinically assess the amount of fixed flexion. Three examiners repeated the process one week later.

The mean error from the radiograph in the navigation group was 2.18 degrees (95%CI 2.18+/−0.917) compared to 5.57 degrees (CI 5.57+/− 0.715) in the observer group. The navigation was more consistent with a range of error of only 5.5 degrees (standard deviation 1.59). The observers had a range of error of 18.5 degrees (S.D. = 4.06). When analysing the observers’ error with respect to flexion (+) and extension (−), they tended to under-estimate the amount of knee flexion (median error=−4) whereas the navigation was more evenly distributed (median error=0). The highest correlation was found between navigation and the radiograph r=0.96. The highest observer correlation with the radiograph was a consultant surgeon (r=0.91) and the worst was from a resident (r=0.74). The intra-class correlation coefficient was 0.88 for the three surgeons who repeated the measurements; their mean error was 3.5 degrees with a range of fifteen degrees.

The use of computer navigation appears to be more accurate in assessing the degree of knee flexion, with a reduced range of error when compared to clinical assessment. It is therefore less likely to leave the patient with residual fixed flexion after knee arthroplasty.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 231 - 231
1 May 2009
Aslim N Schemitsch E Tokunaga K Waddell J
Full Access

The purpose of this study was to evaluate the effect of previous femoral osteotomy on the outcome of total hip replacement performed for degenerative arthritis secondary to developmental dysplasia of the hip.

Eighty three primary total hip arthroplasties were performed in sixty-nine patients with osteoarthritis secondary to developmental hip dysplasia (DDH) with a minimum three year follow up. Twenty six hips had undergone previous femoral osteotomy (eleven hips, femoral osteotomy alone (FO); fifteen hips, combined femoral and pelvic osteotomy and fifty-seven hips, no previous surgery. The non operative patients with DDH served as an age and sex matched control group (control). Cementless arthroplasty was performed in seventy-eight hips. The mean duration from femoral osteotomy to primary THA was 22.9 years. The mean follow up was 7.6 years (FO) and 7.2 years (control).

The overall revision rate was 15.4 % (FO) and 21.1 % in the Control group (p> 0.05). Twenty-one hips had one or more complications during or after surgery. The FO group had a higher femoral fracture rate (23.1%) compared to controls (10.5%) (p< 0.05). At latest mean follow-up (7.4 yrs (range, two to sixteen)), the mean Harris hip score was eighty-five (FO) and eighty-five (control group) (p> 0.05). The function and pain scores in the femoral osteotomy group were similar to the controls (p> 0.05). The requirement for bone grafting was similar and operative time significantly greater (FO) compared to controls. The frequency of radiolucent lines around the femoral component in the FO group (36%) was significantly higher than the control group (12.2%) (p< 0.05). Survival analysis was performed with the Kaplan-Meier method. At ten years, the survival of the acetabular component was 84.6%/73.6% and for the femoral component 92.2%/96% in the FO/control group.

Patients with a prior femoral osteotomy have no significant difference in functional outcome, overall complication rate or revision rate compared to controls. However, there is a significant increase in femoral fracture and operative time. Previous femoral osteotomy does not compromise the functional outcome of subsequent total hip arthroplasty.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 222 - 222
1 May 2009
Davis E Gallie P Olsen M Schemitsch E Waddell J
Full Access

To assess the accuracy of plain digitised radiographic images for measurement of neck-shaft and stem-shaft angles in hip resurfacing arthroplasty.

Fifteen patients having undergone hip resurfacing arthroplasty with the Birmingham Hip Resurfacing (BHR) were selected at random. Digital radiographs were analyzed by three observers. Each observer measured the femoral neck-shaft angles (NSA) of the pre-operative and stem-shaft angles (SSA) of the postoperative radiographs on two separate occasions spanning one week. The effect of femur position on SSA measured by digital radiographs was also analyzed. A BHR prosthesis was cemented into a third generation Sawbone composite femur. Radiographs were taken with the synthetic specimen positioned in varying angles of both flexion and external rotation in increments of 10° ranging from 0° to 90°.

The mean intraobserver difference in measured angle was 3.13° (SD 2.37°, 95% CI +/−4.64°) for the NSA group and 1.49° (SD 2.28°, 95% CI +/−4.47°) for the SSA group. The intraclass correlation coefficient for the NSA group was 0.616 and for the SSA group was 0.855. Flexion of the synthetic femur of twenty degrees resulted in a five degree discrepancy in measured SSA and flexion of forty degrees resulted in a thirteen degree discrepancy. External rotation of the synthetic specimen of twenty and forty degrees resulted in a three and nine degree discrepancy in measured SSA, respectively.

Patient malposition during radiographic imaging can contribute to erroneous NSA and SSA results. Significant intra- and inter-observer variation was noted in the measurement of neck shaft angle however, variation was less marked for measurement of stem shaft angle.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 241 - 241
1 May 2009
Ward S Escott B Beaton D Kovacs E Aslam N Abughaduma R McKee M Waddell J Kreder H Schemitsch E
Full Access

The purpose of this study was to evaluate functional outcome following supracondylar femur fractures using patient-based outcome measures.

Patients having sustained supracondylar femur fractures between 1990 and 2004 were identified from the fracture databases of two level-one trauma centres. Three patient-based outcome measures, the Short Form-36 (SF-36) Version two, the Short Musculoskeletal Functional Scale (SMFA), and the Lower Extremity Functional Scale (LEFS) were used to evaluate functional outcome. Each patient’s medical record was also reviewed to obtain information regarding potential predictors of outcome, including age, gender, fracture type (AO classification), presence of comorbidities, smoking status, open vs. closed fracture, and occurrence of complications. Univariate and multivariate models were then used to identify significant predictors of outcome, as reflected in the SMFA bother and dysfunction scores.

Sixty-one patients (thirty-five males and twenty-six females) with an average age (at time of injury) of 53 ± 18 years consented to participate. The average length of follow-up was 64 ± 34 months from the time of injury. Mean SF-36 V2 scores were lower than Canadian population norms indicating decreased function or greater pain, while mean SMFA scores were higher than published population norms indicating greater impairment and bother. The mean LEFS score was 40.78 ± 15.90 out of a maximum score of eighty. At the univariate level, the presence of complications was a significant predictor of both the SMFA bother (p=0.002) and dysfunction scores (p=0.015), while positive smoking status was a significant predictor of the bother score (p=0.002). Based on a multivariate linear regression model, the presence of complications (p=0.013) and positive smoking status (p=0.011) were both significant predictors of a higher SMFA bother score. In the multivariate model for SMFA dysfunction score, the presence of complications (p=0.014) and the presence of comorbidities (p=0.017) were significant predictors of a higher score.

Comparing SF-36 and SMFA scores with published population norms, supracondylar femur fractures were associated with residual impact. Based on our analysis, smoking, the presence of medical comorbidities at the time of fracture, and the occurrence of complications following fracture repair were the main predictors of poorer patient outcomes following supracondylar femur fracture.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 222 - 222
1 May 2009
Davis E Olsen M Schemitsch E Waddell J Webber C
Full Access

We aimed to establish if radiological parameters, dual energy x-ray absorbtiometry (DEXA) and quantitative CT (qCT) could predict the risk of sustaining a femoral neck fracture following hip resurfacing.

Twenty-one unilateral fresh frozen femurs were used. Each femur had a plain AP radiograph, DEXA scan and quantitative CT scan. Femurs were then prepared for a Birmingham Hip Resurfacing femoral component with the stem shaft angle equal to the native neck shaft angle. The femoral component was then cemented onto the prepared femoral head. No notching of the femoral neck occurred in any specimens. A repeat radiograph was performed to confirm the stem shaft angle. The femurs were then potted in a position of single leg stance and tested in the axial direction to failure using an Instron mechanical tester. The load to failure was then analysed with the radiological, DEXA and qCT parameters using multiple regression.

The strongest correlation with the load to failure values was the total mineral content of the femoral neck at the head/neck junction using qCT r= 0.74 (p< 0.001). This improved to r=0.76 (p< 0.001) when neck width was included in the analysis. The total bone mineral density measurement from the DEXA scan showed a correlation with the load to failure of r=0.69 (p< 0.001). Radiological parameters only moderately correlated with the load to failure values; neck width (r=0.55), head diameter (r= 0.49) and femoral off-set (r=0.3).

This study suggests that a patient’s risk of femoral neck fracture following hip resurfacing is most strongly correlated with total mineral content at the head/neck junction and bone mineral density. This biomechanical data suggests that the risk of post-operative femoral neck fracture may be most accurately identified with a pre-operative quantitative CT scan through the head/neck junction combined with the femoral neck width.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 49 - 49
1 Mar 2009
Aslam N Saito J Tokunaga K Schemitsch E Waddell J
Full Access

Purpose: To determine the differences in bone remodelling between a metaphyseal and a diaphyseal fixed stem in uncemented total hip arthroplasty.

Methods: Twenty-three patients undergoing uncemented total hip arthroplasty (28 hips) utilizing a metaphyseal fit stem were matched to 27 patients (32 hips) undergoing uncemented total hip arthroplasty utilizing a diaphyseal fit stem. Patients were matched for age, gender and follow-up. All patients were assessed by clinical and radiographic examination at 6 weeks, 3 months, 6 months and yearly thereafter. Radiographs were assessed for periprosthetic bone remodelling, canal fill, canal shape and bone quality using the cortical index and the Singh index. At latest follow-up all radiographs were assessed for frequency and time of appearance of spot welds, cortical hypertrophy and development of pedestal formation. All patients were assessed clinically utilizing the modified Harris hip score.

Results: At one year there was no difference in the clinical results between the two groups of patients utilizing the modified Harris hip score 90.6 + 1.5 in metaphyseal fit stems versus 91.7 + 1.7 for diaphyseal fit stems (p> 0.05). There was no statistical difference between the two groups in either femoral canal shape or bone quality–canal-to-calcar ratio 0.49 versus 0.45 (p> 0.05); cortical index 0.45 versus 0.44 (p> 0.05); Singh index 3.44 versus 3.70 (p> 0.05). In assessing canal fill proximal canal fill was statistically greater in metaphyseal fit stems and distal canal fill was significantly greater in diaphyseal fit stems (p< 0.01). There was a statistically significant increase in the frequency and timing of spot welds in metaphyseal stems at 3 months and 6 months (p< 0.05) but no difference in the frequency of spot welds at 1 year and 2 years. Cortical hypertrophy was significantly increased at 6 months, 1 year and 2 years in metaphyseal fit stems as compared to diaphyseal fit stems (p< 0.05). There was no difference in pedestal formation at 1 year or 2 years between the two stem groups (p> 0.05).

Conclusions: After one year the only significant difference between these two groups of patients is increased cortical hypertrophy in those patients undergoing metaphyseal versus diaphyseal stem insertion. Both stem designs demonstrated bone remodelling with no differences in spot welds or pedestal formation. At two years there was no functional difference between these two patient groups.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 43 - 44
1 Mar 2009
Davis E Lingard E Schemitsch E Waddell J
Full Access

We aimed to identify whether patients in lower socioeconomic groups had worse function prior to total knee arthroplasty and to establish whether these patients had worse post-operative outcome following total knee arthroplasty. Data was obtained from the Kinemax outcome study, this was a prospective observational study of 974 patients undergoing primary total knee arthroplasty for osteoarthritis. The study was undertaken in thirteen centers, four in the United States, six in the United Kingdom, two in Australia and one in Canada. Pre-operative data was collected within six weeks of surgery and patients were followed for two years post-operatively. Pre-operative details of the patient’s demographics, socioeconomic status (education and income), height, weight and co-morbid conditions were obtained. The WOMAC and SF-36 scores were also obtained. Multivariate regression was utilised to analyse the association between socioeconomic status and the patient’s pre-operative scores and post-operative outcome. During the analysis, we were able to control for variables that have previously been shown to effect pre-operative scores and post-operative outcome. Patients with a lower income had a significantly worse pre-operative WOMAC pain (p=0.021) and function score (p=0.039) than those with higher incomes. However, income did not have a significant impact on outcome except for WOMAC Pain at 12-months (p=0.014). At all the other post-operative assessment times, there was no correlation between income and WOMAC Pain and WOMAC Function. Level of education did not correlate with pre-operative scores or with outcome at any time during follow-up. This study demonstrates that across all four countries, patients with lower incomes appear to have a greater need for total knee arthroplasty. However, level of income and educational status did not appear to effect the final outcome following total knee arthroplasty. Patients with lower incomes appear able to compensate for their worse pre-operative score and obtain similar outcomes post-operatively.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 17 - 17
1 Mar 2009
Davis E Gallie P Macgroarty K Waddell J Schemitsch E
Full Access

Alignment of the femoral component during hip resurfacing has been implicated in the early failure of this device. Techniques to facilitate a more accurate placement of the femoral component may help prevent these early failures. We aim to establish whether the use of imageless computer navigation can improve the accuracy in alignment of the femoral component during hip resurfacing.

6 pairs of cadaveric limbs were randomized to the use of computer navigation or standard instrumentation. All hips had radiographs taken prior to the procedure to facilitate accurate templating. All femoral components were planned to be implanted with a stem shaft angle of 135 degrees. The initial guide wire was placed using either the standard jig with a pin placed in the lateral cortex or with the use of an imageless computer navigation system. The femoral head was then prepared in the same fashion for both groups. Following the procedure radiographs were taken to assess the alignment of the femoral component.

The mean stem shaft angle in the computer navigation group was 133.3 degrees compared to 127.7 degrees in the standard instrumentation group (p=0.03). The standard instrumentation group had a range of error of 15 degrees with a standard deviation of 4.2 degrees. The computer navigated group had a range of error of only 8 degrees with a standard deviation of 2.9 degrees.

Our results demonstrated that the use of standard alignment instrumentation consistently placed the femoral component in a more varus position when compared to the computer navigation group. The computer navigation was also more consistent in its placement of the femoral component when compared to standard instrumentation. We suggest that imageless computer navigation appears to improve the accuracy of alignment of the femoral component during hip resurfacing.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 134 - 134
1 Mar 2009
Aslam N pan J Schemitsch E Waddell J
Full Access

Purpose: The purpose of this study was to evaluate total hip arthroplasty (THA) in the treatment of posttraumatic arthritis following acetabular fracture and to compare the long-term outcome of THA after previous open reduction and internal fixation (ORIF) or conservative treatment of the acetabular fracture.

Method: Thirty-four patients (thirty-six hips) underwent total hip arthroplasty for arthritis resulting from acetabular fractures. There were twenty-six males (27 hips) and eight females (9 hips). The mean age at the time of hip arthroplasty was 49 years (range, 25–78 years). The mean follow-up was eight years and nine months (range, 4–17 years). The mean interval from fracture to arthroplasty was 7.5 years (range, 5 months-29 years). Two patients died of unrelated causes and two patients were lost to follow up. Thirty patients (32 hips) were available for latest follow up. Twenty-one hips had been previously treated by open reduction internal fixation and 11 hips had conservative treatment.

Results: Sixteen patients achieved and maintained a good to excellent result over the course of the follow-up. There was no difference in improvement of mean Harris Hip Score between both groups (p> 0.05).

Ten out of 32 hips required revision; 9 acetabular components were revised because of aseptic loosening (3), osteolysis/excessive wear (4), instability (1) and infection (1) with a total revision rate of 28%. Eight patients needed acetabular revision alone, one femoral revision alone and one revision of both components. There was no significant difference in bone grafting, heterotopic bone formation, revision rate, operative time and blood loss between the two groups (p> 0.05).

Conclusions: Those patients initially treated conservatively had similar long term results compared to those treated primarily by open reduction internal fixation. At long term follow-up the main problem identified was osteolysis and acetabular wear.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 146 - 146
1 Mar 2009
Davis E Webber C Olsen M Zdero R Waddell J Schemitsch E
Full Access

We aimed to establish if radiological parameters, dual energy x-ray absorbtiometry (DEXA) and quantitative CT (qCT) could predict the risk of sustaining a femoral neck fracture following hip resurfacing. 21 unilateral fresh frozen femurs were used. Each femur had a plain AP radiograph, DEXA scan and quantitative CT scan. Femurs were then prepared for a Birmingham Hip Resurfacing femoral component with the stem shaft angle equal to the native neck shaft angle. The femoral component was then cemented onto the prepared femoral head. No notching of the femoral neck occurred in any specimens. A repeat radiograph was performed to confirm the stem shaft angle. The femurs were then potted in a position of single leg stance and tested in the axial direction to failure using an Instron mechanical tester. The load to failure was then analysed with the radiological, DEXA and qCT parameters using multiple regression. The strongest correlation with the load to failure values was the total mineral content of the femoral neck at the head/neck junction using qCT r= 0.74 (p< 0.001). This improved to r=0.76 (p< 0.001) when neck width was included in the analysis. The total bone mineral density measurement from the DEXA scan showed a correlation with the load to failure of r=0.69 (p< 0.001). Radiological parameters only moderately correlated with the load to failure values; neck width (r=0.55), head diameter (r= 0.49) and femoral off-set (r=0.3). This study suggests that a patient’s risk of femoral neck fracture following hip resurfacing is most strongly correlated with total mineral content at the head/neck junction and bone mineral density. This biomechanical data suggests that the risk of post-operative femoral neck fracture may be most accurately identified with a pre-operative quantitative CT scan through the head/neck junction combined with the femoral neck width.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 15 - 15
1 Mar 2009
Davis E Olsen M Zdero R Papini M Waddell J Schemitsch E
Full Access

Introduction: We aimed to examine the effect of neck notching during hip resurfacing on the strength of the proximal femur.

Methods: Third generation composite femurs that have been shown to replicate the biomechanical properties of human bone were utilised. Imageless computer navigation was used to position the initial guide wire during head preparation. Six specimens were prepared without a superior notch being made in the neck of the femur, six were prepared in an inferiorly translated position to cause a 2mm notch in the superior femoral neck and six were prepared with a 5mm notch. All specimens had radiographs taken to ensure that the stem shaft angle was kept constant. The specimens were then loaded to failure in the axial direction with an Instron mechanical tester.

A three dimensional femoral finite element model was constructed and molded with a femoral component constructed from the dimensions of a Birmingham Hip Resurfacing. The model was created with a superior femoral neck notch of increasing depths.

Results: The 2mm notched group (mean load to failure 4034N) were significantly weaker than the un-notched group (mean load to failure 5302N) when tested to failure (p=0.017). The 5mm notched group (mean load to failure 3121N) were also significantly weaker than the un-notched group (p=0.0003) and the 2mm notched group (p=0.046). All fractures initiated at the superior aspect of the neck, at the component bone interface. The finite element model revealed increasing Von Mises stresses with increasing notch depth.

Discussion: A superior notch of 2mm in the femoral neck weakens the proximal femur by 24% and a 5mm notch weakens it by 41%. This study provides biomechanical evidence that notching of the femoral neck may lead to an increased risk of femoral neck fracture following hip resurfacing due to increasing stresses in the region of the notch.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 305 - 305
1 Jul 2008
Davis E Olsen M Zdero R Waddell J Schemitsch E
Full Access

Introduction: It has been suggested that femoral component alignment in the coronal plane affects the risk of sustaining femoral neck fracture following hip resurfacing. Previous literature suggests that increasing the stem shaft angle to an extreme valgus position produces the most favourable biomechanical properties following femoral component insertion. We examined the effects of femoral component alignment during hip resurfacing on proximal femur strength.

Methods: 3rd generation composite femurs shown to replicate biomechanical properties of human bone were used. The bones were secured in a position of single leg stance and tested with an Instron mechanical tester. Imageless computer navigation was used to position the guide wire during femoral head preparation. Specimens were placed in 115, 125 and 135 degrees of stem shaft angulation. No notching was made in the femoral neck during head preparation. The femoral components were cemented in place. Radiographs were taken ensuring that stem shaft angles were correct. Specimens were loaded to failure in the axial direction.

Results: A component position of 115 degrees compared to 125 degrees reduced load to failure from 5475N to 3198N (p=0.009). A position of 135 degrees (5713N) compared to 125 degrees (5475N) did not significantly alter the load to failure (p=0.347). Component positioning at a stem shaft angle below 125 degrees resulted in a significant reduction in strength of the proximal femur. Placement of the component at 115 degrees reduced the load to failure by 42%.

Discussion: Our findings suggest that a varus orientation may be at risk for causing femoral neck fracture. The advantages of increasing valgus angle beyond 125 degrees may not provide as much reduction in the incidence of femoral neck fracture as previously suggested, particularly when considering the inherent risk of femoral neck notching in these positions.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 315 - 315
1 Jul 2008
Davis E Gallie P Waddell J Schemitsch E
Full Access

Introduction: When performing a hip resurfacing procedure through the postero-lateral approach, concern has been expressed as to the proximity of the femoral neurovascular bundle during the anterior capsulotomy. We aimed to identify the proximity of the femoral nerve, artery and vein during an anterior capsulotomy.

Methods: 5 fresh frozen cadaveric limbs were used. A standard postero-lateral approach was performed. An anterior incision was then made to identify the femoral neurovascular bundle. Measurements were taken prior to hip dislocation. The femoral head was dislocated, capsulotomy scissors were inserted though the posterior incision and positioned to cut the superior and then inferior aspects of the anterior capsule. The distance from the scissors to each of the neurovascular structures were recorded. Measurements were made with the hip in flexion and extension.

Results: Prior to dislocation the mean distance from the capsule was 25mm for the femoral nerve, 21mm for the artery and 21mm for the vein. Following dislocation, with the hip in extension the distance during cutting of the antero-superior capsule to the nerve, artery and vein was 31mm. With the hip in a flexed position, the distance from all three neurovascular structures increased by a mean of 5mm. When the scissors were positioned to cut the antero-inferior capsule in extension, the mean distances to the nerve, artery and vein were 31mm, 28mm and 28mm. When the hip was flexed, the distance to the nerve decreased by 2mm.

Discussion: Our study suggests that the neurovascular structures are relatively well protected during an anterior capsulotomy performed during hip resurfacing. The procedure may be safer if the capsulotomy is performed with the hip dislocated and the hip in a flexed position while cutting the antero-superior aspect and in an extended position while cutting the antero-inferior aspect.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 306 - 306
1 Jul 2008
Davis E Kureshi S Olsen M Papini M Zdero R Waddell J Schemitsch E
Full Access

Introduction: Notching of the femoral neck during preparation of the femur during hip resurfacing has been associated with an increased risk of femoral neck fracture. We aimed to evaluate this with the use of a finite element model.

Methods: A three dimensional femoral model was used and molded with a femoral component constructed from the dimensions of a Birmingham Hip Resurfacing. Multiple constructs were made with the component inferiorly translated in order to cause a notch in the superior femoral neck. The component angulation was kept constant. Once constructed the model was imported into the Ansys finite element model software for analysis. Elements within the femoral model were assigned different material properties depending on cortical and cancellous bone distributions. Von Misses stresses were evaluated near the notches and compared in each of the cases.

Results: In the un-notched case the maximum Von Mises stress was only 40MPa. However, with the formation of a 1mm notch the stress rose to 144MPa and in the 4 mm notch the stress increased to 423MPa. These values demonstrated that a 1mm notch increased the maximum stress by 361% while a 4mm notch increased the maximum stress by 1061%.

Discussion: This study demonstrated that causing a notch in the superior femoral neck dramatically increases the stress within the femoral neck. This may result in the weakening of the femoral neck and potentially predispose it to subsequent femoral neck fracture. The data suggests that even a small notch of 1mm may be detrimental in weakening the femoral neck by dramatically increasing the stress in the superior neck. This study suggests that any femoral neck notching should be avoided during hip resurfacing.