Periprosthetic fractures are an increasingly
common complication following joint replacement. The principles
which underpin their evaluation and treatment are common across
the musculoskeletal system. The Unified Classification System proposes
a rational approach to treatment, regardless of the bone that is
broken or the joint involved. Cite this article:
Tapered, fluted, modular, titanium stems are
increasingly popular in the operative management of Vancouver B2 and
selected B3 peri-prosthetic femoral fractures. We have reviewed
the results at our institution looking at stem survival and clinical
outcomes and compared this with reported outcomes in the literature.
Stem survival at a mean of 54 months was 96% in our series and 97%
for combined published cases. Review of radiology showed maintenance
or improvement of bone stock in 89% of cases with high rates of
femoral union. Favourable clinical outcome scores have reported
by several authors. No difference in survival or clinical scores
was observed between B2 and B3 fractures. Tapered stems are a useful
option in revision for femoral fracture across the spectrum of femoral
bone deficiency. Cite this article:
Hip arthrodesis remains a viable surgical technique
in well selected patients, typically the young manual labourer with
isolated unilateral hip disease. Despite this, its popularity with
patients and surgeons has decreased due to the evolution of hip
replacement, and is seldom chosen by young adult patients today.
The surgeon is more likely to encounter a patient who requests conversion
to total hip replacement (THR). The most common indications are
a painful pseudarthrosis, back pain, ipsilateral knee pain or contralateral
hip pain. Occasionally the patient will request conversion because
of difficulty with activities of daily living, body image and perceived
cosmesis. The technique of conversion and a discussion of the results
are presented. Cite this article:
Tapered, fluted, modular, titanium stems have
a long history in Europe and are increasing in popularity in North America.
We have reviewed the results at our institution looking at stem
survival and clinical outcomes. Radiological outcomes and quality
of life assessments have been performed and compared to cylindrical
non-modular cobalt chromium stems. Survival at five years was 94%.
This fell to 85% at ten years due to stem breakage with older designs.
Review of radiology showed maintenance or improvement of bone stock
in 87% of cases. Outcome scores were superior in tapered stems despite
worse pre-operative femoral deficiency. Tapered stems have proved
to be a useful alternative in revision total hip arthroplasty across
the spectrum of femoral bone deficiency.
Antibiotic impregnated articulating spacers are
used in two-stage revision total knee arthroplasty to deliver local antibiotic
therapy while preserving function. We have observed infection control
in greater than 95% of cases with functional outcomes approaching
those seen in revision for aseptic loosening. Higher failure has
been observed with methicillin resistant organisms.
Dislocation after revision total hip is a common complication. The purpose of this study was to assess whether a large femoral head (36/40mm) would result in a decreased dislocation rate compared to a standard head (32mm). A randomized clinical trial was undertaken to assess the effect of large femoral heads on dislocation after revision total hip. Patients undergoing revision hip arthroplasty at seven centers were randomized to 32mm head or 36/40mm head. Patients were stratified according to surgeon. Primary endpoint was dislocation. Rates were compared with Fishers exact test. Secondary outcome measures were quality of life: WOMAC, SF-36 and satisfaction. One hundred eighty four patients were randomized: 92 in the 32mm head group and 92 in the large head group. Baseline demographics were similar in the two groups. Patients were followed from two to five years postoperativelyPurpose
Method
There is a postulated association between increased serum metal ions and pseudotumour formation in patients with metal-on-metal hip replacements. The primary aim of this study was to assess the prevalence of pseudotumour in 31 asymptomatic patients with a large femoral head (LFH) metal-on-metal hip implant. This was compared to the prevalence of pseudotumour in 20 matched asymptomatic patients with a hip resurfacing (HRA) and 24 matched asymptomatic patients with a standard metal-on-polyethylene (MOP) total hip. A secondary objective was to assess possible correlation between increased serum metal ions and pseudotumour formation Ultrasound examination of the three groups was performed at a minimum follow up of two years. Serum metal ions were measured in the metal-on-metal LFH and HRA groups at a minimum of two years.Purpose
Method
The purpose of this study was to compare and evaluate the cost-effectiveness of the MIS Anterolateral Approach to that of the MIS Posterolateral and MIS Direct Lateral Approach. A prospective randomized control trial was designed and conducted to compare the MIS Anterolateral Approach to that of the MIS Posterolateral and MIS Direct Lateral Approach. Contemporary methods for economic evaluation were used to ascertain direct and indirect costs (in Canadian dollars) along with clinical effectiveness outcomes (SF6D and Pat5D utility measures). University and hospital ethics was obtained and patients were recruited and consented to participate in the RCT resulting in the assignment of 130 patients MIS hip arthroplasty procedures. Baseline patient demographics, comorbidity, quality of life, and utility were obtained for all patients. In-hospital costing data was obtained including operating room and patient room costs as well as medication, rehab and complications. Post-discharge costs were calculated from direct and indirect costs of medication, rehab, medical costs and complications until one year post-operatively. Clinical effectiveness measures were administered at intervals until one year post-operatively.Purpose
Method
combine FA and Vancomycin, and Linezolid alone in PMMA cement and characterize antibiotic elution, and to improve drug release using polyethylene glycol (PEG) and NaCl in PMMA cement.
We report the outcome at ten to 15 years of two-stage revision for hip infection in 99 patients using the Prostalac articulated hip spacer system. All the patients were contacted to determine their current functional and infection status using the Oxford-12, Short form-12, and Western Ontario and McMaster University Osteoarthritis Index questionnaires. A total of 11 of the 99 patients had a further infection, of whom seven responded to repeat surgery with no further sequelae. The mean interval between the stages was five months (1 to 36). We were able to review 48 living patients, with a mean age of 72 years (46 to 86), 34 (71%) of whom provided health-related quality-of-life outcome scores. The mean follow-up was 12 years (10 to 15). The long-term success rate was 89% and with additional surgery this rose to 96%. The mean global Western Ontario and McMaster University Osteoarthritis Index score was 80.6 ( Two-stage revision for hip infection using a Prostalac interim spacer offers a predictable and lasting solution for patients with this difficult problem.
determine predictors of pain, function and activity level 1–2 years after revision hip arthroplasty and define quality of life outcomes after revision total hip replacement.
When considering WOMAC pain as an outcome variable, factors predictive of improving category outcome included baseline WOMAC function (p= 0.001), age between 60–70 (p<
0.004), male gender (p= 0.005), lower Charnley class (p<
0.001) and no previous revisions (p <
0.023). Baseline WOMAC pain did not predict final pain outcome. Baseline WOMAC function (p=0.001), the indication for the operation (p=0.007), and the operating surgeon were significant predictors of UCLA activity at follow up. Peri or post-operative complications were not an adverse predictor of physical function, pain or activity.
Revision of a failed acetabular reconstruction in total hip arthroplasty (THA) can be challenging when associated with significant bone loss. In cementless revision THA, achieving initial implant stability and maximising host bone contact is key to the success of reconstruction. Porous tantalum acetabular shells may represent an improvement from conventional porous coated uncemented cups in revision acetabular reconstruction associated with severe acetabular bone defects.
A prospective cohort of 222 patients who underwent revision hip replacement between April 2001 and March 2004 was evaluated to determine predictors of function, pain and activity level between one and two years post-operatively, and to define quality of life outcomes using validated patient reported outcome tools. Predictive models were developed and proportional odds regression analyses were performed to identify factors that predict quality of life outcomes at one and two years post-operatively. The dependent outcome variables were the Western Ontario and McMaster Osteoarthritis Index (WOMAC) function and pain scores, and University of California Los Angeles activity scores. The independent variables included patient demographics, operative factors, and objective quality of life parameters, including pre-operative WOMAC, and the Short Form-12 mental component score. There was a significant improvement ( Predictors of quality of life outcomes after revision hip replacement were established. Although some patient-specific and surgery-specific variables were important, age, gender, Charnley class and pre-operative WOMAC function score had the most robust associations with outcome.