Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 44 - 44
1 Apr 2019
Ogawa T Ando W Yasui H Hashimoto Y Koyama T Tsuda T Ohzono K
Full Access

Introduction

The anatomic abnormalities are observed in developmental dysplasia of the hip (DDH) and it is challenging to perform the total hip arthroplasty (THA) for some DDH patients. If acetabular cup was placed at the original acetabular position in patients with high hip dislocation, it may be difficult to perform reduction of hip prosthesis because of soft tissue contracture. The procedures resolving this problem were to use femoral shortening osteotomy, or to place the acetabular cup at a higher cup position than the original hip center. Femoral shortening osteotomy has some concerns about its complicated procedure, time consuming, and risk of non-union. Conversely, implantation of the acetabular cup at the higher cup position may eliminate these shortcomings and this procedure is considered to be preferred if possible. However, the criteria of cases without femoral shortening osteotomy are not clear. In this study, we retrospectively analysed the clinical outcomes of patients performed THAs for high hip dislocation, and clarified the adaptation of THA with or without femoral shortening osteotomy.

Methods

We included a total of 65 hip joints from 57 patients who underwent primary THA using Modulus stem for high hip dislocation from November 2007 to December 2015 at our institution. The mean follow up period was 5.2 years (2 – 10 years). The mean age at surgery was 65.4 years (Table 1). Thirty seven hips were classified as Crowe III, and twenty eight hips as Crowe IV based on Crowe classification.

We classified patients into two groups based on the use of femoral osteotomy. Then, we compared the surgical time, blood loss, Japanese Orthopaedic Association (JOA) Score as clinical outcomes, preoperative position of the greater trochanter, the cup position, and complications between two groups. The position of the greater trochanter was measured the height of the tip of greater trochanter from the inter teardrop line. The cup center position was assessed by measuring the distance between the cup center and ipsilateral tear drop. Receiver operating characteristic (ROC) curves were plotted for deciding the cut-off value for the height of the greater trochanter. The cut-off value presented the maximum sensitivity and specificity was determined.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 23 - 23
1 Mar 2017
Sugano N Nakahara I Hamada H Takao M Sakai T Ohzono K
Full Access

The purposes of this study were to review retrospectively the 25-year survival of cemented and cementless THA for hip dysplasia and to compare the effect of fixation methods on the long-term survival in patients with DDH. We retrospectively reviewed all patients with OA secondary to hip dysplasia treated with a cemented Bioceram hip system between 1981 and 1987, and a cementless cancellous metal Lübeck hip system between 1987 and 1991. The studied subjects were 76 hips of cemented THA (Group-C) and 57 hips of cementless THA (Group-UC). Both hip implants had a 28-mm alumina head on polyethylene articulation. The mean age at operation was 50.5 years (range, 36–60 years) in Group-C and 50.0 years (range, 29–60 years) in Group-UC. The survival at 25 years regarding any revision as the endpoint was 46% in Group-C and 76% in Group-UC. These difference was significant using Log-rank test (P=0.008). The cup survival at 25 years was 47% in Group-C and 83% in Group-UC (P= 0.0003). The stem survivals at 25 years were 95% in Group-C and 92% in Group-UC. (P= 0.416). Cementless THA in patients with DDH showed a higher survival rate at 25 years than cemented THA because of the excellent survival of the acetabular component without cement. We conclude that cementless THA with the cancellous metal Lübeck hip system led to better longevity at 25 years than cemented THA with the Bioceram in patients with OA secondary to DDH.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 88 - 88
1 May 2016
Tsujimoto T Ando W Hashimoto Y Koyama T Yamamoto K Ohzono K
Full Access

INTRODUCTION

To obtain appropriate joint gap and soft tissue balance, and to correct the lower limb alignment are important factor to achieve success of total knee arthroplasty (TKA). A variety of computer-assisted navigation systems have been developed to implant the component accurately during TKA. Although, the effects of the navigation system on the joint gap and soft tissue balance are unclear. The purpose of the present study was to investigate the influence of accelerometer-based portable navigation system on the intraoperative joint gap and soft tissue balance.

METHODS

Between March 2014 and March 2015, 36 consecutive primary TKAs were performed using a mobile-bearing posterior stabilized (PS) TKA (Vanguard RP; Biomet) for varus osteoarthritis. Of the 36 knees, 26 knees using the accelerometer-based portable computer navigation system (KneeAlign2; OrthAlign) (N group), and 10 knees using conventional alignment guide (femur side; intramedullary rod, tibia side; extramedullary guide) (C group). The intraoperative joint gap and soft tissue balance were measured using tensor device throughout a full range of motion (0°, 30°, 45°, 60°, 90°, 120°and full flexion) at 120N of distraction force. The postoperative component coronal alignment was measured with standing anteroposterior hip-to-ankle radiographs.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 56 - 56
1 May 2016
Sugano N Takao M Sakai T Nishii T Ohzono K
Full Access

Introduction

Metal on metal hip resurfacing (MoM HR) is attractive for young active patients. Patients with osteonecrosis of the femoral head (ONFH) are relatively young. HR can be an option of treatment, however, long-term stability of the femoral component is a concern because of the necrotic lesion in the femoral head. There is also a concern of ARMD for MoM implants. The purpose of this study is review a 10 year outcome of a consecutive patients with ONFH who underwent MoM HR.

Methods

The subjects of this study were 30 hips of 26 patients with ONFH who underwent HR between 1998 and 2004. There were 21 hips of 18 males and 9 hips of 8 females. The average age at operation was 40 years (range, 20–63 years). 19 ONFHs were induced by steroid and 11 ONFHs were alcohol related. According to the Japanese Investigation Committee classification, there were 8 hips with Type C1 and 22 hips with Type C2. There were 16 hips in stage 3A, 7 hips in Stage 3B, and 7 hips in Stage 4. Operation was performed through a posterior approach. A fragile necrotic bone was curettage thoroughly and the defect was filled with cement.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 79 - 79
1 Jan 2016
Tsujimoto T Hashimoto Y Ando W Koyama T Yamamoto K Ohzono K
Full Access

INTRODUCTION

The concept of anatomical stam is fit-and-fill in the proximity of the femur and to expect wall fixation, following to reduce thigh pain and stress shielding. Although the femoral medullary form and size are different in each races. CentPillar TMZF stem (stryker ®) is anatomical stem designed based on computer-tomography of Japanese femurs. The purpose of this study was to evaluate clinical and radiographic outcomes of CentPillar TMZF stem at a mean of 3.6 years postoperatively.

METHODS

We asseses the results of 98 primary total hip arthroplasty (THA) performed using a CentPillar TMZF stem in 91 Japanese patients (4 males, 94 females) undergoing surgery between August 2007 and June 2011, the mean age at the time of surgery was 62.0 (41–81) years old. The Diagnosis were osteoarthritis (OA) in 91 hips, rapidly destructive coxopathy (RDC) in 4 hips, rheumatoid arthritis (RA) in 3 hips. Clinical and radiographic assessments were performed for every patient for every follow up using Japan Orthopaedic Association (JOA) Score, thigh pain, revision surgery and complications. Radiographic assessments were including stem alignment on anteroposterior radiograph, stress shielding, bone remodeling, radiolucent line, osteolysis, loosening and subsidence.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 136 - 136
1 Jan 2016
Yamamoto K Ando W Koyama T Ohzono K
Full Access

The Taperloc Microplasty stem design was based on that of the Taperloc stem with flat tapered wedge and the distal portion of the Taperloc stem was shortened by 35mm.

We report the minimum two-year follow up (mean, 26 months) of 68 primary total hip arthroplasty using the Taperloc Microplasty stem. 39 Magnum acetabular cups and 29 M2a Taper acetabular cups were inserted with metal on metal articulation. The series comprised 67 patients (20 men, 47 women) with a mean age at operation of 65 years (31 to 85). The principal diagnosis was osteosrthritis.

Their mean JOA Hip Score improved significantly from 36 points preoperatively to 96 points at two-year follow up. Radiological asseement showed good bony stability in all implants. There was one case of post operative anterior dislocation. We did not see intra-operative fracture previously reported for this implant. There were no clinical and radiological complications related to MOM articulation.

This short-term follow up study demonstrates that the clinical outcome of the Tapeloc Microplasty stem is comparable with that of standard Taperloc stem and other flat taper wedge stems.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 33 - 33
1 Jan 2016
Hashimoto Y Tsujimoto T Ando W Koyama T Yamamoto K Ohzono K
Full Access

Modulus femoral prosthesis is a modular cementless femoral system which consists of 5 degree tapered conical stem made of a titanium alloy with 8 fins of 1mm and modular neck. Modular neck enables to control any ideal stem anteversion as a surgeon prefers. This system is considered to be useful in severe hip deformity, for example developmental dysplasia of the hip (DDH). In this study, clinical and radiographic outcomes of the Modulus femoral prosthesis were evaluated at a mean of 3.6 (2–6) years postoperatively.

We assessed the results of 193 primary total hip arthroplasty using a Modulus femoral prosthesis in 169 patients (15 males, 154 females) undergoing surgery between September 2007 and December 2011. The mean age at the time of surgery was 65.6 (31–86) years old. The diagnoses were osteoarthritis (OA) in 178 hips (including 167 hips of DDH), rapidly destructive coxopathy (RDC) in 6 hips, rheumatoid arthritis (RA) in 6 hips, osteonecrosis in 2 hips, and subchondral insufficiency fracture in one hip. Clinical outcomes were assessed using Japan Orthopedic Association (JOA) hip scores and complications. Radiographic assessments were including stem alignment, bone on-growth, cortical hypertrophy, stress shielding and stem subsidence.

43.8 points of the preoperative mean JOA score was significantly improved to 93.1 points postoperatively. In one case intraoperative femoral fracture was occurred. One dislocation had occurred and thigh pain was observed in one hip. No revision surgery was required. In 192 hips of 193 hips (99.5%), stem was implanted in neutral position (within ±2 degrees). Bone on-growth was observed in all cases (94.3% in zone 3; 73.1% in zone 5; 30.6% in zone 2; 22.3% in zone 6). Cortical hypertrophy was observed in 66 hips (34.2%) at zone 3 and 5. Reduction of bone density due to stress shielding was observed (1st degree was 58.5%; 2nd degree was 29.5%; 3rd degree was 11.9%; 4th degree was 0%). In 22 cases (11.4%), more than 2mm of stem subsidence was observed, however the subsidence was stopped within 6 months in all cases.

Modulus femoral prosthesis showed good clinical results and radiographic findings up to 6 years postoperatively.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 17 - 17
1 Jan 2016
Ando W Yamamoto K Aihara M Koyama T Hashimoto Y Tsujimoto T Ohzono K
Full Access

Metal on metal total hip arthroplasty (MoM THA) provides the potential improvement in articular wear. However, several adverse events including pseudotumor had been reported. Magnetic resonance imaging (MRI) was considered to be the proposal tool for detection of pseudotumor after MoM THA. In this study, we performed the screening of pseudotumor after MoM THA using the MRI.

We studied 43 patients with M2a Magnum® (Biomet) and 34 patients with M2a Taper® (Biomet) of MoM THA from December 2009 to December 2011 with follow-up of 2.5 years (2.0–4.0 years) after surgery. MRI assessments were performed at a mean of 2.1 years postoperatively. Pseudotumor findings were graded using Anderson classification (Skeletal Radiol, 2011: 40; 303). Age, sex, height, weight, Harris Hip Score, EQ5D satisfaction score, UCLA activity score, and blood metal ion levels were evaluated.

The prevalence of pseudotumor was 27.2%; 56 normal (Type A), 13 mild (C1), 8 moderate (C2) and none were graded severe (C3). Weight and BMI in the mild group was significantly higher than those in normal. There was no significant difference in age, sex and height among these groups. With regard to Harris Hip score, pain and ROM score in moderate group was significantly lower than that in normal and mild group. EQ5D satisfaction score and UCLA activity score showed not significant differences among groups. 3.01±3.32 μg/L of blood cobalt ion levels in the moderate groups was significantly higher than 0.97±0.64 μg/L in normal group. Blood cobalt ion levels of 1 mild and 2 moderate were over the threshold of 7 μg/L. These patients were implanted with M2a Taper, not M2a Magnum. 14% of the prevalence in the patients with M2a Magnum was significantly lower than 41% in the patients with M2a Taper. No revision surgeries were required.

The patients with no pseudotumor did not show the increase of blood metal ion. Contrarily, several patients showed the increase of blood metal ion in case of detecting pseudotumor. MRI assessments were useful for screening of pseudotumor after MoM THA and blood metal ion should be investigated for patients with mild and moderate pseudotumor in MoM THA.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 228 - 228
1 Dec 2013
Ando W Yamamoto K Koyama T Fudo K Tsujimoto T Aihara M Ohzono K
Full Access

Metal on metal total hip arthroplasty provides the potential improvement in articular wear and the use of large-diameter femoral heads following the prospect for reduction in the risk of dislocation. The purpose of this study was to compare the clinical and radiographic outcomes as well as serum metal ion level between the two different component designs with small and large femoral heads in metal on metal total hip arthroplasty.

We studied 39 patients with large head (Magnum®, Biomet; cup size minus 6 mm) and 37 patients with small head (M2a taper®, Biomet; 28 or 32 mm head) of metal on metal total hip arthroplasty between December 2009 to October 2011 with follow-up of 2.1 years (1.0–3.3 years) after surgery. Harris Hip Score, UCLA activity score, EQ-5D, radiographic assessment, and serum cobalt and chromium ion levels were evaluated.

Harris Hip Score, UCLA activity score, and EQ-5D were improved after surgery in small and large head groups, however, no significant differences were observed between both groups. Cup inclination was below 50 degree in all prosthesis. No loosening and no osteolysis were observed. Cobalt and chromium ion was not detected before surgery; however, metal ion levels of both groups were increased after surgery in time dependent manner. There was no significant difference between two groups at one year after surgery. One patient in each group showed the increase of cobalt ion level over 7 ppb (15.4 ppb, 12.9 ppb) without any clinical symptom including pain. Cup inclination was 29 degree in both patients and cup anteversion was 38 and 41 degree, respectively.

There was no significant difference of ion levels between both groups. No dislocation was observed in large head group while one dislocation occurred in small head group. No patients required the revision surgery.

This metal on metal component, especially with large femoral heads, showed the good clinical results at the maximum follow up of 3.3 year after surgery. However, the ion level of two patients increased over 7 ppb and longer follow-up will be needed.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 130 - 131
1 Mar 2010
Minoda Y Aihara M Sakawa A Fukuoka S Umeda N Tomita M Hayakawa K Tada K Ohzono K
Full Access

The range of motion (ROM) after total knee arthroplasty (TKA) is one of the most important factors for patient satisfaction, especially in Asian countries. To enhance the knee flexion angle, “high-flexion” designs have been introduced in total knee prostheses. One of such design was a new design of femoral prosthesis, which increased the posterior cut on the bone by 2 mm and thickened the posterior condyle, allowing the posterior condylar radius to continue further. There were several reports on postoperative ROM of such “high-flexion” posterior-stabilized (PS) total knee prosthesis. However, there was no report on the postoperative ROM of “high-flexion” cruciate ligament retaining (CR) total knee prosthesis. The purpose of this study was to compare the ROM associated with standard and high-flexion posterior CR total knee prostheses.

One hundred and fifty-one consecutive patients (176 knees) had CR total knee prosthesis. 89 knees had standard CR TKA (NexGen CR, Zimmer, Warsaw, IL), and 87 knees had high-flexion CR knee prostheses (NexGen CR-Flex, Zimmer, Warsaw, IL). Differences in the age, diagnosis, preoperative Knee Society Score (KSS), and preoperative ROM of the knee between two groups were not significant. At one year postoperatively, the patients were assessed clinically and radiographically.

The mean postoperative KSS knee score was 96.2 points for the standard CR prosthesis group and 96.7 points for the high-flexion CR prosthesis group (p=0.464). The mean postoperative KSS function score was 83.4 points for the standard CR prosthesis group and 84.8 points for the high-flexion CR prosthesis group (p=0.446). The mean postoperative ROM was 110.8 degrees in the standard CR prosthesis group, and 114.0 degrees in high-flexion prosthesis group (p=0.236). No knee had aseptic loosening, revision, or osteolysis.

Previous report showed that “high-flexion” PS design did not increase postoperative ROM compared to standard design. However, there was no report on the postoperative ROM of “high-flexion” CR total knee prosthesis. We found no significant differences between the standard CR group and “high-flexion” CR group with regard to ROM or clinical and radiographic parameters. However, in the cases which achieved high flexion, “high-flexion” design, which chamfered posterior femoral edge, can reduce the possibility of deformation from posterior contacts under lord. Therefore, the results of the current study suggested that “high-flexion” CR design is not the design that increase ROM significantly, but might be the safe design even when the knee achieved deep flexion.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 167 - 167
1 Mar 2010
Sugano N Nishii T Miki H Sakai T Takao M Ohzono K
Full Access

To analyze the long term results of a third generation ceramic on ceramic bearing in cementless total hip arthroplasty (THA), we reviewed the clinical and radiological results of 100 consecutive THAs performed in 86 patients (68 females, 80 hips; 18 males, 20 hips) between 1996 and 1998. The average age at operation was 55 years with a range of 26 to 73 years. The diagnoses were osteoarthritis in 83 hips, osteonecrosis in 10 hips and rheumatoid arthritis in 7 hips. The articulation was composed of a hemispherical titanium porous bead-coated cup (AnCA), a Biolox Forte alumina ceramic cup liner and a ball with a diameter of 28-mm. The modular ceramic liner was fixed directly to the metal cup without polyethylene sandwich or metal rim. A press-fit technique of 1 mm under-reaming without screws was used for cup fixation. The ceramic head was fixed to a 12/14 taper cone of a modular neck which allowed changes in neck-shaft angle, anteversion, and offset. All operations were performed via a posterolateral approach under general anesthesia. To measure the cup orientation, an ellipse was fitted to the acetabular component rim on the early postoperative AP radiographs using computer software. The average cup inclination and anteversion in the radiographic definition were 41 (range 28 to 63) and 17 (range 3 to 34) degrees, respectively. 22 cups were outside the Lewinnek safe zone. All patients were radiographically evaluated in term of implant stability at two years using Engh’s criteria. All of the acetabular components radiologically were judged to be bone-ingrown stable at two years except one cup. 98 stems were judged to be bone-ingrown stable and the remaining two stems were judged to be fibrous stable at two years. After two years, all patients except for two were followed up clinically and radiologically for at least 10 years or until revision or death. One unstable cup was revised at 2.5 years. This case had a previous Chiari’s pelvic osteotomy and insufficient press-fit of the cup was assumed to have led to loosening. One of the two fibrous stable stems was revised at six years due to aseptic loosening. One rheumatoid arthritis hip with stable bone ingrown fixation developed late infection at six years and was revised. One stable cup showed chipping of the acetabular liner at 8 years and required revision. The orientation of this cup was 55 degrees of inclination and 17 degrees of anteversion and the high inclination was thought to be related to the ceramic liner chipping. The remaining hips showed no osteolysis or loosening at the final follow-up. There were no squeaking hips. The 10-year survivorships with the endpoint of mechanical loosening or revision were 96.7% and 95.6%, respectively. We conclude that the third generation ceramic on ceramic hip bearing without polyethylene sandwich provided long term stability and eliminated periprosthetic osteolysis.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 409 - 409
1 Apr 2004
Sakai T Sugano N Ohzono K Lee S Nishii T Miki H Haraguchi K Yoshikawa H
Full Access

Introduction: The purpose of this study is to evaluate the clinical and radiogra phic outcome of patients with secondary osteoarthritis of the hip, who underwent custom-made cementless THA.

Methods: Between January 1994 and June 1997, 98 prim ary cementless custom-made THA’s were performed in 76 patients with secondary osteoarthritis and reviewed at mean 6 years follow-up (range: 4 – 7.5 years). Nine patients had a previous femoral osteotomy. There were 69 females and seven males. The mean age at operation was 54 years (40 – 73 years). Custom-made, 125 mm-long, titanium femoral components with blasted surface were fabricated based on the computerized tomography.

Results: The mean Harris Hip Score improved from 43 to 95 points. 97 patients (99%) had more than 80 points for total score, and 2 patients (2%) had thigh pain at the latest follow-up. Radiographically, 86 hips (87%) showed obviously extensive bone ongrowth onto the middle part of the stem while 8 hips (9%) showed stable fibrous fixation. Four hips (4%) were unstable: more than 2 mm subsidence in 2 hips and more than 2 degrees varus migration in 2 hips. Of these 4 hips, 2 had intraoperative cracks of the poximal femur and 2 had varus positioning of the stem.

Discussion and conclusion: Cementless THA has been advocated to enhance fit and fill of variable hip geometry. However, some clinical studies failed to show that custom implants significantly improve clinical success or implant longevity because their surface finish was not optimal. Custom-made titanium femoral components with blasted surface showed good clinical results. The reasons for radiolographical failures were because of intraoperative technical errors and these might be derived from 125 mm-long stem with maximum canal fill. A shorter stem may be an option because it may improve the feasibility of stem insertion and the distal fill.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 145 - 145
1 Feb 2004
Sakai T Ohzono K Lee S Sugano N Nishii T Miki H Takao M Koyama T Morimoto D Yoshikawa H
Full Access

Introduction: In order to investigate the relationship between the degeneration of the acetabular cartilage and the radiological staging of osteonecrosis of the femoral head, the following study was performed.

Materials and Methods: Acetabular cartilage with sub-chondral bone was taken from the superior dome from 34 hips from 30 patients undergoing total hip arthroplasty due to osteonecrosis of the femoral head. The specimens were stained with hematoxylineosin and safranin-O, and were evaluated as to the thinning of cartilage, fibrillation, clefts, and proliferation of chondrocytes. There were 18 females and 12 males with an average age of 49 years. We used the radiological staging system proposed by the working group of the Specific Disease Investigation Committee under the auspices of the Japanese Ministry of Health, Labor and Welfare. There were eight hips in stage IIIA disease (collapse of the femoral head less than 3 mm), 19 hips in stage IIIB disease (collapse 3 mm or greater), and seven stage IV disease hips.

Results: All 34 specimens showed histological abnormalities. In eight stage IIIA hips, six hips were mild and two were moderate histological degeneration. In 19 stage IIIB hips, five hips were mild, six were moderate, and eight had severe arthrosis. Seven stage IV hips had severe arthrosis.

Discussion: Although the radiographs cannot demonstrate early degeneration of cartilage, degenerative changes were present in all stage III hips. Histological degenerative changes in stage IIIB hips were more severe than those in stage IIIA hips. These findings should be kept in mind in treating patients with osteonecrosis of the femoral head.