header advert
Results 1 - 5 of 5
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Bone & Joint Open
Vol. 2, Issue 3 | Pages 191 - 197
1 Mar 2021
Kazarian GS Barrack RL Barrack TN Lawrie CM Nunley RM

Aims

The purpose of this study was to compare the radiological outcomes of manual versus robotic-assisted medial unicompartmental knee arthroplasty (UKA).

Methods

Postoperative radiological outcomes from 86 consecutive robotic-assisted UKAs (RAUKA group) from a single academic centre were retrospectively reviewed and compared to 253 manual UKAs (MUKA group) drawn from a prior study at our institution. Femoral coronal and sagittal angles (FCA, FSA), tibial coronal and sagittal angles (TCA, TSA), and implant overhang were radiologically measured to identify outliers.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 24 - 24
1 Oct 2020
Kazarian GS Barrack RL Barrack TN Lawrie CM Nunley RM
Full Access

Introduction

The purpose of this study was to compare the radiographic outcomes of manual versus robotic-assisted medial unicompartmental knee arthroplasty (UKA).

Materials & Methods

Postoperative radiographic outcomes from 86 consecutive robotic-assisted UKAs (RAUKA group) from a single academic center were retrospectively reviewed and compared to 253 manual UKAs (MUKA group) drawn from a prior study at our institution. Femoral coronal and sagittal angles (FCA, FSA), tibial coronal and sagittal angles (TCA, TSA), and implant overhang were radiographically measured to identify outliers. Clinical results at 4–6 weeks postoperative were compared to a control cohort of total knee arthroplasty (TKA) patients from our institution.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 4 - 4
1 Oct 2019
Lawrie CM Okafor LC Kazarian GS Barrack TN Barrack RL Nunley RM
Full Access

Background

The purpose of this study was to assess the overall clinical and radiographic outcomes of unicompartmental knee arthroplasty (UKA) in the 2–10 year postoperative period. The secondary goal was to compare outcomes between fixed- (FB) and mobile-bearing (MB) implant designs.

Methods

We performed a retrospective analysis of 237 consecutive primary medial UKAs from a single academic center. All cases were performed by high-volume fellowship-trained arthroplasty surgeons, though UKA comprised <10% of their overall knee arthroplasty practice (<20 medial UKAs per surgeon per year). Clinical outcomes included the Oxford Knee Scores (OKS) and revision rates. Femoral and tibial coronal and sagittal angles (FCA, FSA, TCA, TSA) were radiographically measured. FCA (>±10º deviation from the neutral axis), FSA (>15º flexion), TCA (>±5º deviation from the neutral axis), and TSA (>±5º deviation from 7º) outliers were defined. Far outliers were defined as measurements that fell an additional >±2º outside of these ranges. Outcomes were compared between the FB and MB groups.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 8 - 8
1 Oct 2019
Lawrie CM Schloemann D Kazarian GS Barrack TN Barrack RL
Full Access

Background

The aim of this study was to determine the change in standing pelvic sagittal alignment and associated impact on functional acetabular component position at follow-up after total hip arthroplasty (THA).

Patients and Methods

A retrospective review was performed on 91 consecutive patients who had undergone primary THA by a single surgeon via a posterior approach in the lateral decubitus position. Of these, 41 patients had high quality standing AP pelvis radiographs preoperatively, at six weeks postoperatively, and at one year postoperatively available for analysis. Pelvic ratio was defined as the ratio between the vertical distance from the inferior sacroiliac (SI) joints to the superior pubic symphysis and the horizontal distance between the inferior SI joints. Apparent changes in the functional acetabular component position were determined from the change in pelvic ratio between the preoperative and one year postoperative standing AP pelvic radiograph. A change of at least five degrees was considered clinically meaningful.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 19 - 19
1 Oct 2018
Kazarian GS Barrack TN Donaldson MJ Lawrie CM Miller GA Haddad FS Barrack RL
Full Access

Introduction

Implant malalignment is an important predictor of prosthetic failure following total knee arthroplasty (TKA). The purpose of this study was to determine the incidence of outliers for common alignment targets and the impact of surgeon volume and experience on the accuracy of implant alignment with current generation manual instrumentation.

Methods

This study was a retrospective, multi-center, radiographic analysis of 1675 consecutive primary uncomplicated TKAs from seven surgeons at three academic and state-funded centers in the US and UK. Surgeons were categorized as “high-volume” (≥50 TKAs/year) and “high-experience” (≥5 years post-fellowship). Femorotibial, tibial varus/valgus, and posterior tibial slope angles were digitally measured using postoperative radiographs. Femorotibial (<2° or >8° valgus), tibial (> ±3° deviation from the neutral axis), and tibial slope (<0° or >7° of flexion for cruciate retaining, <0° or >5° of flexion for posterior stabilized) angle outliers were identified. The proportion of outliers among surgeons in each subgroup was compared.