header advert
Results 1 - 27 of 27
Results per page:
Bone & Joint Open
Vol. 3, Issue 5 | Pages 441 - 447
23 May 2022
Mikkelsen M Wilson HA Gromov K Price AJ Troelsen A

Aims

Treatment of end-stage anteromedial osteoarthritis (AMOA) of the knee is commonly approached using one of two surgical strategies: medial unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA). In this study we aim to investigate if there is any difference in outcome for patients undergoing UKA or TKA, when treated by high-volume surgeons, in high-volume centres, using two different clinical guidelines. The two strategies are ‘UKA whenever possible’ vs TKA for all patients with AMOA.

Methods

A total of 501 consecutive AMOA patients (301 UKA) operated on between 2013 to 2016 in two high-volume centres were included. Centre One employed clinical guidelines for the treatment of AMOA allowing either UKA or TKA, but encouraged UKA wherever possible. Centre Two used clinical guidelines that treated all patients with a TKA, regardless of wear pattern. TKA patients were included if they had isolated AMOA on preoperative radiographs. Data were collected from both centres’ local databases. The primary outcome measure was change in Oxford Knee Score (OKS), and the proportion of patients achieving the patient-acceptable symptom state (PASS) at one-year follow-up. The data were 1:1 propensity score matched before regression models were used to investigate potential differences.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 830 - 839
1 May 2021
Ahmed I Chawla A Underwood M Price AJ Metcalfe A Hutchinson CE Warwick J Seers K Parsons H Wall PDH

Aims

Many surgeons choose to perform total knee arthroplasty (TKA) surgery with the aid of a tourniquet. A tourniquet is a device that fits around the leg and restricts blood flow to the limb. There is a need to understand whether tourniquets are safe, and if they benefit, or harm, patients. The aim of this study was to determine the benefits and harms of tourniquet use in TKA surgery.

Methods

We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled trials, and trial registries up to 26 March 2020. We included randomized controlled trials (RCTs), comparing TKA with a tourniquet versus without a tourniquet. Outcomes included: pain, function, serious adverse events (SAEs), blood loss, implant stability, duration of surgery, and length of hospital stay.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 828 - 829
1 May 2021
Ahmed I Chawla A Underwood M Price AJ Metcalfe A Hutchinson CE Warwick J Seers K Parsons H Wall PDH


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 941 - 949
1 Jul 2020
Price AJ Kang S Cook JA Dakin H Blom A Arden N Fitzpatrick R Beard DJ

Aims

To calculate how the likelihood of obtaining measurable benefit from hip or knee arthroplasty varies with preoperative patient-reported scores.

Methods

Existing UK data from 222,933 knee and 209,760 hip arthroplasty patients were used to model an individual’s probability of gaining meaningful improvement after surgery based on their preoperative Oxford Knee or Hip Score (OKS/OHS). A clinically meaningful improvement after arthroplasty was defined as ≥ 8 point improvement in OHS, and ≥ 7 in OKS.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 652 - 659
1 Jun 2019
Abram SGF Beard DJ Price AJ

Aims

The aim of the British Association for Surgery of the Knee (BASK) Meniscal Consensus Project was to develop an evidence-based treatment guideline for patients with meniscal lesions of the knee.

Materials and Methods

A formal consensus process was undertaken applying nominal group, Delphi, and appropriateness methods. Consensus was first reached on the terminology relating to the definition, investigation, and classification of meniscal lesions. A series of simulated clinical scenarios was then created and the appropriateness of arthroscopic meniscal surgery or nonoperative treatment in each scenario was rated by the group. The process was informed throughout by the latest published, and previously unpublished, clinical and epidemiological evidence. Scenarios were then grouped together based upon the similarity of clinical features and ratings to form the guideline for treatment. Feedback on the draft guideline was sought from the entire membership of BASK before final revisions and approval by the consensus group.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 22 - 27
1 Oct 2016
Bottomley N Jones LD Rout R Alvand A Rombach I Evans T Jackson WFM Beard DJ Price AJ

Aims

The aim of this to study was to compare the previously unreported long-term survival outcome of the Oxford medial unicompartmental knee arthroplasty (UKA) performed by trainee surgeons and consultants.

Patients and Methods

We therefore identified a previously unreported cohort of 1084 knees in 947 patients who had a UKA inserted for anteromedial knee arthritis by consultants and surgeons in training, at a tertiary arthroplasty centre and performed survival analysis on the group with revision as the endpoint.


Bone & Joint Research
Vol. 3, Issue 11 | Pages 305 - 309
1 Nov 2014
Harris KK Price AJ Beard DJ Fitzpatrick R Jenkinson C Dawson J

Objective

The objective of this study was to explore dimensionality of the Oxford Hip Score (OHS) and examine whether self-reported pain and functioning can be distinguished in the form of subscales.

Methods

This was a secondary data analysis of the UK NHS hospital episode statistics/patient-reported outcome measures dataset containing pre-operative OHS scores on 97 487 patients who were undergoing hip replacement surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 33 - 33
1 Jul 2012
Weston-Simons JS Pandit H Halikar V Price AJ Dodd CAF Popat M Murray DW
Full Access

STUDY PURPOSES

To evaluate the role of “top up” intra-articular local anaesthetic injection in patients who have had UKR.

METHOD AND RESULTS

43 patients scheduled to have a cemented Oxford UKR were prospectively recruited and randomised. All patients had the same initial anaesthetic regime of general anaesthesia, femoral nerve block and intra-operative intra-articular infiltration. All patients had a multi-holed epidural catheter placed intra-articularly prior to wound closure. Patients had the same operative technique, post operative rehabilitation and rescue analgesia.

An independent, blinded observer recorded post-operative pain scores using a visual analogue score every 6 hours and any rescue analgesia. On the morning after surgery, 22 patients, (Group I), received 20 mls of 0.5% bupivicaine through the catheter whilst 21, (Group II), patients had 20 mls of normal saline by the same observer, after which the catheter was removed.

No statistical difference was found in pain scores on the day of operation between the groups. However, patients in Group I had a significantly better pain score initially post top up and at 6 hours (2.4 (0-8) vs 5.7 (2-9), p<0.001). This cohort of patients required less rescue analgesia (p<0.001). In addition, Group I had statistically significant higher patient satisfaction outcome scores after the infiltration, (p<0.001).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 74 - 74
1 Jul 2012
Al-Ali S Alvand A Gill HS Beard DJ Jackson W Price AJ Rees JL
Full Access

Rheumatology and Musculoskeletal Sciences, NIHR Biomedical Research Unit, University of Oxford and the Nuffield Orthopaedic Hospital, Oxford

Purpose

The aim of this study was to use motion analysis to objectively study the learning curve of surgical trainees performing arthroscopic meniscal repair on a training model in a skills laboratory.

Background

With improving technology and an appreciation of its likely chondroprotective effects, meniscal repair surgery is becoming more common. It remains a difficult procedure and is not routinely learnt during surgical training.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 12 - 12
1 May 2012
Simpson DJ Kendrick B Price AJ Murray D Gill H
Full Access

Introduction

Unicompartmental Knee Replacement (UKR) is an appealing alternative to Total Knee Replacement (TKR) when the patient has isolated compartment osteoarthritis (OA). A common observation post-operatively is radiolucency between the tibial tray wall and the bone. In addition, some patients complain of persistent pain following implantation with a UKR; this may be related to elevated bone strains in the tibia. The aim of this study was to investigate the mechanical environment of the tibia bone adjacent to the tray wall, following UKR, to determine whether this region of bone resorbs, and how altering the mechanical environment affects tibia strains.

Materials and methods

A finite element (FE) model of a cadaver tibia implanted with an Oxford UKR was used in this study, based on a validated model. A single static load, measured in-vivo during a step-up activity was used. There was a 1 mm layer of cement surrounding the keel in the cemented UKR, and the cement filled the cement pocket. In accordance with the operating procedure, no cement was used between the tray wall and bone. For the cementless UKR a layer of titanium filled the cement pocket. An intact tibia was used to compare to the cemented and cementless UKR implanted tibiae. The tibia was sectioned by the tray wall, defining the radiolucency zone (parallel to the vertical tray wall, 2 mm wide with a volume of 782.5 mm3), corresponding to the region on screened x-rays where radiolucencies are observed. Contact mechanics algorithms were used between all contacting surfaces; bonded contact was also introduced between the tray wall and adjacent bone, simulating a mechanical tie between them. Strain energy density (SED), was compared between the intact and implanted tibia for the radiolucency zone. Equivalent strains were compared on the proximal tibia between the intact and implanted tibia models. Forty patients (20 cemented, 20 cementless) who had undergone UKR were randomly selected from a database, and assessed for radiolucency.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 18 - 18
1 May 2012
Snelling SJ Davidson RK Swingler TE Price AJ Clark IM
Full Access

Purpose

To identify genes showing altered expression in osteoarthritic (OA) cartilage and synovium. Dkk3, a member of the Dickoppf family of Wnt signalling inhibitors was overexpressed and this work highlights the potential function of Dkk3 in OA.

Methods

Real-time PCR was used to compare the expression of 270 cytokines, chemokines and their receptors in cartilage and synovium from OA and non-OA patients. Expression of Dkk3 was also measured in ATDC5 cells and in bovine nasal cartilage (BNC) explants treated with inflammatory cytokines. The effect of Dkk3 on hydroxyproline and GAG release was measured in BNC explant cultures.

To assess the distribution of Dkk3 in OA cartilage immunohistochemistry was carried out on anteromedial gonarthrosis specimens. The level of Dkk3 in synovial fluid tricompartmental and unicompartmental cartilage lesions was measured using ELISA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 26 - 26
1 Mar 2012
Gulati A Pandit H Gill HS Price AJ Dodd CAF Murray DW
Full Access

INTRODUCTION

Mobile bearing unicompartmental knee replacement (UKR) is an accepted treatment for patients with isolated medial unicompartmental knee osteoarthritis (OA) with a full thickness cartilage loss. The aim of this study was to determine if this recommendation was correct and if the procedure could be used for partial-thickness cartilage loss.

METHODS

1053 Oxford medial UKRs were studied prospectively. The knees were divided into two groups; partial-thickness cartilage loss (PTCL) group and the full thickness-cartilage loss (FTCL) group. The primary outcome measure was the total Oxford Knee Score (OKS, 0 to 48) at the time of final follow up. The groups were also compared for the change in OKS (?OKS) and the proportion of patients that were considered to have benefited substantially from surgery (?OKS >5).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 16 - 16
1 Mar 2012
Rout R Mcdonnell SM Jayadev C Xia Z Murray D Hulley PA Price AJ
Full Access

Aim

This aim of this study was to investigate apoptosis, reactive oxygen species (ROS), and their upstream markers in Anteromedial Gonarthrosis (AMG).

Methods

Ten resection specimens, from patients undergoing unicompartmental knee replacement for AMG, and ten control specimens, collected from vascular disease patients undergoing above knee amputation, were used. Routine histology and immunohistochemical studies were conducted for Terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL), Active Caspase 3, Cytochrome C, Active Bax, Bim, 3-Nitrotyrosine and Forkhead box O3A (FOXO 3A).


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 411 - 411
1 Jul 2010
Kendrick BJL Simpson D Bottomley NJ Marks B Pandit H Beard D Gill HS Dodd CA Murray DW Price AJ
Full Access

Purpose: This study was designed to establish the poly-ethylene wear rates in the Oxford medial unicompert-mental knee replacement.

Introduction: The Oxford meniscal bearing knee was introduced as a design to reduce polyethylene wear. There has been one previous retrieval study of the Oxford UKA, which reported very low wear rates in some specimens, but abnormal patterns of wear in others, including impingement. There has been no further investigation of these abnormal wear patterns.

Methods: Forty-seven bearings were retrieved from patients who had received a medial Oxford UKA for anteromedial osteoarthritis of the knee, none of which had previously been studied. Mean time to revision was 8.4 years (SD 4.1) and 20 had been implanted for over 10 years. The macroscopic pattern of polyethylene wear and the linear penetration (dial gauge measurement) was recorded for each bearing.

Results: The mean linear penetration rate (LPR) was 0.07mm/year. The patterns of wear fell into 4 categories, each with a different LPR; 1) No abnormal macroscopic appearance, n=16 (LPR = 0.01mm/year), 2) Abnormal macroscopic wear with extra-articular impingement, n=16 (LPR = 0.05mm/year), 3) Abnormal macroscopic wear with intra-articular impingement, n=6 (LPR = 0.10mm/year), 4) Abnormal macroscopic wear with impingement and signs of incongruous articulation, n=9 (LPR = 0.14mm/year). The differences in LPR were statistically significant (p< 0.05).

Conclusion: The results show that very low polyethylene wear rates are possible if the device functions normally. However if the bearing displays abnormal function (extra-articular, intra-articular impingement or incongruous articulation) wear rates increase significantly.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 421 - 421
1 Jul 2010
Monk AP Simpson DJ Ostlere S Dodd CAF Doll H Price AJ Beard DJ Gill HS Murray DW Gibbons CLMH
Full Access

Introduction: Patellofemoral joint subluxation is associated with pain and dysfunction. The causes of patel-lofemoral subluxation are poorly understood and multi-factorial, arising from abnormalities of both bone and soft tissues. This study aims to identify which anatomical variables assessed on Magnetic Resonance (MR) images are most relevant to patellofemoral subluxation.

Method: A retrospective analysis of MR studies of 60 patients with suspected patellofemoral subluxation was performed. All patients were graded for the severity/ magnitude of radiological subluxation using a dynamic MR scan (Grade 0 [nil] to Grade 3 [subluxed]. The patient scans were assessed using a range of anatomical variables, these included:

Patella alta,

Patella type (Wiberg classification),

Trochlea sulcus angles for bone and cartilage,

The shortest horizontal distance between the most distal part of the vastus medialis obliquis (VMO) muscle to the supra-medial aspect of the patella,

Trochlea and patella cartilage thickness (maximum depth),

The horizontal distance between the tibial tubercle and the midpoint of the femoral trochlea (TTD),

Patella Engagement – represented as the percentage of the patella height that is captured in the trochlea groove when the knee is in full extension,

A Discriminant Analysis test for multi-variant analysis was applied to establish the relationship between each bony/soft tissue anatomical variable and the severity/magnitude of patellofemoral subluxation.

Results: The distance of the VMO from the patella (p < 0.001), TTD (p < 0.001) and Patella Engagement (p < 0.001) showed highly significant relationships with patellofemoral subluxation.

Conclusions: The following three anatomical variables are associated with patellofemoral subluxation: the distance of the VMO muscle from the patella, TTD and Patella Engagement.

This is the first study to establish that patella engagement is related to PFJ subluxation showing that the lower the percentage engagement of the patella in the trochlea, the greater the severity/magnitude of patellofemoral subluxation. The finding provides greater insight into the aetiology and understanding of the mechanism of symptomatic PFJ subluxation.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 60 - 61
1 Mar 2010
McDonnell* SM Rout R Hollander AP Clark IM Murray DW Gill HS Hulley PA Price AJ
Full Access

Anteromedial Osteoarthritis of the Knee (AMOA) is a distinct phenotype of OA. Within this pattern of disease, the anterior third of the medial tibial plateau exhibits full thickness cartilage loss. The middle third has damaged partial thickness cartilage, and the posterior third has retained cartilage, which is seen on macroscopic visual assessment to be normal. This study investigates the molecular features of progressive severities of cartilage damage within this phenotype.

Ten medial tibial plateau specimens were collected from patients undergoing unicompartmental knee replacements. The cartilage within the area of macroscopic damage was divided into equal thirds: T1(most damaged), to T3 (least damaged). The area of macroscopically undamaged cartilage was taken as a 4th sample, N. The specimens were prepared for histological (Safranin-O) and immunohistochemical analysis (Type I and II Collagen, proliferation and apoptosis). Immunoassays were undertaken for Collagens I and II and GAG content. Real time PCR compared gene expression between areas T and N.

There was a decrease in OARSI grade across the four areas, with progressively less fibrillation between areas T1, T2 and T3. Area N had a grade of 0 (normal). The GAG immunoassay showed decreased levels with increasing severity of cartilage damage (p< 0.0001). Proliferation and apoptosis, as expected, were increased in the more damaged areas. There was no significant difference in the Collagen II content or gene expression between areas. The Collagen I immunohistochemistry showed increased staining within chondrocyte pericellular areas in the undamaged region (N) and immunoassays showed that the Collagen I content of this macroscopically and histologically normal cartilage, was significantly higher than the damaged areas (p< 0.0001). Furthermore, real time PCR showed a significant increase in Collagen I expression in the macroscopically normal areas compared to the damaged areas (p=0.04).

We conclude that in this phenotype the Collagen I increase, in areas of macroscopically and histologically normal cartilage, may represent very early changes of the cartilage matrix within the osteoarthritic disease process. This may be able to be used as an assay of early disease and as a therapeutic target for disease modification or treatment.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 412 - 412
1 Sep 2009
Gulati A Jenkins C Chau R Pandit HG Dodd CAF Price AJ Simpson DJ Beard DJ Gill HS Murray DW
Full Access

Purpose: Varus deformity after total knee replacement (TKR) is associated with poor outcome. This aim of this study was to determine whether the same is true for medial unicompartmental arthroplasty (UKA).

Methods: 158 patients implanted with the Oxford UKA, using a minimally invasive approach, were studied prospectively for five years. Leg alignment was measured with a long-arm goniometer referenced from Anterior Superior Iliac Spine, centre of patella and centre of ankle. Patients were grouped according to the American Knee Society Score (AKSS). Group A: > 0° varus (n=13, 8.2%); Group B: 0 to 4° valgus (n=39, 24.7%); Group C: 5–10° valgus (normal alignment, n=106, 67.12%). Comparisons were made between the three groups in terms of the absolute and the change in Oxford Knee Score (OKS) and AKSS over the five year period, and the presence of radiolucency.

Results: There was no significant difference in any outcome measure except for Objective-AKSS (p< 0.001). The means and standard deviations of the ΔOKS for the groups were:

24 ± 5,

22 ± 10, and

22 ± 9 and for Objective-AKSS were 84 ± 12, 82 ± 15 and 91 ± 11 respectively.

The frequency of five year radiolucency for the groups A, B, and C were 42%, 35%, and 45% respectively.

Conclusion: The aim of the Oxford UKA is to restore knee kinematics and thus knee alignment to the pre-disease state. Therefore, as demonstrated by this study, about 30% of patients have varus alignment. This study also demonstrates that post-operative varus alignment does not compromise the outcome. The only score which did show worse outcome was the Objective-AKSS. This is because 10 or 20 points are deducted for varus alignment, which is not appropriate following UKA. Therefore, AKSS in its present form is not a reliable tool for assessment of UKA.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 421 - 421
1 Sep 2009
Chau R Pandit HG Gulati A Gray H Beard DJ Gill HS Dodd CAF Price AJ Murray DW
Full Access

Purpose: To identify associative factors for radiolucency (RL) under the tibial component following the Oxford unicompartmental arthroplasty (UKA), and to evaluate its effect on clinical outcome scores.

Method: One hundred and sixty-one knees which had undergone primary Phase 3 medial Oxford UKA were included. Fluoroscopic radiography films were assessed at five years post-operatively for areas of tibial RL. The two groups of patients, with and without RL, were compared to

patients’ pre-operative demographics for age, weight, height, BMI,

intra-operative variables such as the operating surgeon (n=2), insert and component sizes,

post-operative varus/valgus deformity, and

clinical outcome, assessed by the change in Oxford knee (OKS) and Tegner (TS) scores, from before surgery to five-year post-operatively.

Results: 101 (62%) knees were found to have tibial RL. All RL were categorised as physiological or they were < 1mm thick, with sclerotic margins and non-progressive. No statistical difference was found between knees with RL and those without, in terms of pre-operative demographics, intra- or post-operative factors, and clinical outcome scores (p> 0.1 in all variables).

Discussion: Radiolucency (RL) under the tibial component is a common finding following the Oxford UKA. Many theories have been proposed to explain the cause of RL, such as poor cementing, osteonecrosis, micromotion, and thermal necrosis. However, the true aetiology and clinical significance remain unclear. We attempted to address this.

We found no significant relationship between physiological RL, pre-operative demographics, intra-operative variables and clinical outcome scores in this study. Tibial RL remains a common finding following the Oxford UKA yet we do not know why it occurs but in the medium term, clinical outcome is not influenced by RL. In particular, it is not a sign of loosening. Physiological RL can therefore be ignored even if associated with adverse symptoms following the Oxford UKA.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 415 - 415
1 Sep 2009
McDonnell SM Rout R Hollander AP Clark IM Simms T Davidson R Dickinson S Waters J Gill HS Murray DW Hulley PA Price AJ
Full Access

Aim: To investigate the molecular features of progressive severities of cartilage damage, within the phenotype of Anteromedial Osteoarthritis of the Knee (AMOA).

Methods: Ten medial tibial plateau specimens were collected from patients undergoing unicompartmental knee replacements.

The cartilage within the area of macroscopic damage was divided into equal thirds: T1(most damaged), to T3 (least damaged). The area of macroscopically undamaged cartilage was taken as a 4th sample, N. The specimens were prepared for histological (Safranin-O and H& E staining) and immunohistochemical analysis (Type I and II Collagen, proliferation and apoptosis).

Immunoassays were undertaken for Collagens I and II and GAG content. Real time PCR compared gene expression between areas T and N.

Results: There was a decrease in OARSI grade across the four areas, with progressively less fibrillation between areas T1, T2 and T3. Area N had an OARSI grade of 0 (normal).

The GAG immunoassay showed decreased levels with increasing severity of cartilage damage (ANOVA P< 0.0001).

There was no significant difference in the Collagen II content or gene expression between areas.

The Collagen I immunohistochemistry showed increased staining within chondrocyte pericellular areas in the undamaged region (N) and immunoassays showed that the Collagen I content of this macroscopically and histologically normal cartilage, was significantly higher than the damaged areas (ANOVA P< 0.0001). Furthermore, real time PCR showed that there was a significant difference in Collagen I expression between the damaged and macroscopically normal areas (p=0.04).

Conclusion: In AMOA there are distinct areas, demonstrating progressive cartilage loss. We conclude that in this phenotype the Collagen I increase, in areas of macroscopically and histologically normal cartilage, may represent very early changes of the cartilage matrix within the osteoarthritic disease process. This may be able to be used as an assay of early disease and as a therapeutic target for disease modification or treatment.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 258 - 258
1 May 2006
Langdown AJ Pandit H Price AJ Dodd CAF Murray DW Svärd UCG Gibbons CLMH
Full Access

Introduction: This study assesses the outcome of medial unicompartmental knee arthroplasty (UKA) using the Oxford prosthesis for end-stage focal spontaneous osteonecrosis of the knee (SONK, Ahlback grades III & IV).

Methods: A total of 29 knees (27 patients) with SONK were assessed using the Oxford Knee Score. Twenty-six had osteonecrosis of the medial femoral condyle; 3 had osteonecrosis of the medial tibial plateau. This group was compared to a similar group who had undergone Oxford Medial UKA for primary osteoarthritis. Patients were matched for age, sex and time since operation.

Results: Mean length of follow-up was 5.2 years (range 1–13 years). There were no implant failures in either group, but there was one death 9 months post-arthroplasty from unrelated causes in the group with osteonecrosis. The mean Oxford Knee Score in the group with osteonecrosis was 37.8 (± 7.6) and 40.0 (± 6.6) in the group with osteoarthritis. There was no significant difference between the two groups using Student’s t-test (p=0.31).

Interpretation: Use of the Oxford Medial UKA for focal spontaneous osteonecrosis of the knee is reliable in the short to medium term, and gives similar results to when used for patients with primary osteoarthritis.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 439 - 439
1 Apr 2004
Rees JL Price AJ Beard DJ McLardy-Smith P Dodd CAF Murray DW
Full Access

Introduction: A new procedure has been recently adopted to implant the Oxford medial unicompartmental arthroplasty (UCA). All cases are now implanted through a short incision without dislocation of the patella. The aims of this study were to assess the one-year results using this new technique and to determine if the outcome is dependent on surgical experience.

Method: The first 104 Oxford UCA’s (Phase 3) implanted by six surgeons under the care of two consultants were reviewed at one year. All operations were performed using the new technique. The average age at surgery was 68 years. All knees were scored pre-operatively and at review with the American Knee Society score. The cohort was divided into two groups; the first ten cases for each surgeon were included in a ‘learning’ group, whilst the remaining cases were included in an ‘experienced’ group.

Results: Overall the average ‘knee score’ improved from 37 points to 94 and the average ‘functional score’ from 50 points to 92. Average maximum flexion improved from 117° to 131°. The ‘knee score’ for the ‘learning’ group was 91 points. This was significantly less (p = 0.008) than the score of the ‘experienced’ group (96 points).

Conclusions: These results are significantly better than the best historical results of the Oxford (UCA), performed through an open approach with dislocation of the patella.

Despite impressive overall results at one year, lower knee scores were associated with a surgeons ‘learning curve’. After this ‘learning curve’, increased surgical experience led to further improvement with 90% achieving an excellent result, 8% a good, 2% a fair and 0% a poor result.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 55 - 55
1 Jan 2003
Rees JL Beard DJ Price AJ Gill HS Dodd CAF Murray DW
Full Access

Introduction: In conjunction with a bilateral randomised control trial comparing the clinical outcome of two total knee arthroplasties (TKA), we carried out an in-vivo fluoroscopic analysis of both knees in the trial. Knee A, is a new mobile bearing posterior cruciate retaining TKA and Knee B, an established fixed bearing posterior cruciate retaining TKA.

Method: In an ethically approved study, video fluoroscopy was taken of both knees of seven patients performing three exercises; extension against gravity, flexion against gravity and a step up exercise. Ten images at ten-degree intervals over the flexion range were frame grabbed and digitised. The relationship of patella tendon angle (PTA) to knee flexion angle (KFA) was assessed using a newly developed computer system. Five normal knees in fit volunteers were also fluoroscoped and assessed.

Results: A similar pattern of results was obtai ed for all three exercises. Knee A behaved in a linear, more consistent fashion than Knee B, which behaved non-linearly. Analysis of variance showed this difference was significant for all three exercises (p < 0.039).

Conclusions: This bilateral study provides a powerful way of assessing the kinematics of two different knee implants. Knee A behaves in a linear predictable fashion that is nearer normal than Knee B. These results will be used in conjunction with a clinical outcome study and an RSA study to provide a complete assessment of a new TKA.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 52 - 52
1 Jan 2003
Price AJ Svard U
Full Access

The purpose of this study was to establish the long-term clinical outcome of the Oxford Medial Unicompartmental Knee Arthroplasty (UKA).

Methods: A continuous series of 420 patients underwent medial Oxford UKA. Indications were anteromedial osteoarthritis with full thickness lateral compartment cartilage, a functioning anterior cruciate ligament and correctable varus deformity. Survival analysis with all cause revision as the endpoint was carried out for the entire group. At the time of this study 121 were still alive at 10 years and pre/post-operative 10-year clinical data had been prospectively recorded for them from which the AKS and HSS scores were calculated. Results: Seventeen patients required revision (4%) and the fifteen year survival rate was 94.3% (95% CI 85.6 - 100%). At ten years AKS and HSS scores were: AKSS (Knee) pre 30 / post 90, AKSS (Function): pre 42/ post 69 and HSS pre 56/ post 86. The differences were statistically significant (p< 0.01).

Discussion and Conclusion: We conclude that providing careful patient selection is maintained, meniscal bearing medial unicompartmental knee arthroplasty has clinical and survival results comparable to modern total knee arthroplasty. The advantages of lower morbidity and earlier return to function, enhanced by the introduction of minimally invasive techniques may make this the treatment of choice for suitable patients with anteromedial osteoarthritis of the knee.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 52 - 53
1 Jan 2003
Rees JL Price AJ Beard DJ Robinson BJ Dodd CAF Murray DW
Full Access

Introduction: The Oxford medial unicompartmental arthroplasty (UCA) is now routinely performed through a short incision without Dislocation of the patella. The aim of this study was to assess the one-year results of this new technique to determine whether it enhances the quality of outcome, as well as the speed of its achievement.

Method: The first 88 consecutive Oxford UCA’s (Phase 3) implanted into 75 patients by two consultant surgeons were scored pre-operatively and at review with the American Knee Society Score. The average age of the patients was 68.1 years; the male to female ratio was 0.9 to 1.

Results: At review, one patient (one knee) had died and one knee had been revised for infection. The other patients (86 knees) were examined at a mean of 1.3 years from surgery. The average ‘knee score’ improved from 37 points to 95 and the average ‘functional score’ from 51 points to 93. Average maximum flexion improved from 117° to 132°. The ‘knee score’ outcome categories at review were 87% excellent, 8% good, 2.5% fair and 2.5% poor.

Conclusions: Historical comparison of these results with the best results of the Oxford UCA, performed through an open approach with dislocation of the patella, suggest that the minimally invasive approach, in addition to faster recovery, improves the quality of outcome at one year.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 320 - 320
1 Nov 2002
Isaac DL Beard DJ Price AJ Murray D
Full Access

Aim: This study was designed to investigate the nature and extent of tibial translation (TT) during open kinetic chain (OKC) and closed kinetic chain (CKC) activity; recent reports have suggested that the anterior cruciate ligament (ACL) may be strained to an equal amount during CKC and OKC exercise.

Method: Fifteen unilaterally ACL deficient (ACLD) patients and six control subjects underwent fluoroscopic assessment while performing a passive extension exercise, an OKC resisted extension exercise, and a weight-bearing CKC exercise designed to reflect knee motion experienced during dynamic daily activity. Measurements of the patella tendon angle (the angle between the long axis of the tibia and the patella tendon) were obtained to calculate relative TT.

Results: The results show that in ACL intact (ACLI) knees the CKC exercise caused greater anterior TT than the OKC exercise from 0 to 60° of knee flexion (p< 0.05). No difference between ACLI and ACLD knees was detected during the CKC exercise. Maximum weight-bearing (CKC) TT was 8±3 mm. The ACLD tibia during the OKC exercise translated more than the ACLI tibia, and to the same extent as the CKC exercise at 10 to 200 of knee flexion. The ACLI tibia during OKC exercise translated to a maximum of 3±4 mm at 1 0° knee flexion.

Summary: This study has demonstrated that fluoroscopic analysis may be used to detect differences in the kinematics of ACLI and ACLD limbs during activity. It validates recent data demonstrating that the ACL may be strained during CKC exercise to an equal or greater amount than during OKC exercise, and shows that the ACLD knee kinematics are similar to the ACLI knee during CKC exercise. Factors other than the ACL may control the extent of maximal TT during weightbearing activity. This has important consequences for the development of rehabilitation regimes after ACL reconstruction. The commonly held assumption that CKC exercise will protect an ACL graft may not be valid.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 156 - 156
1 Jul 2002
Price AJ Beard D Rees J Carter S White S de Steiger R Gibbons M McLardy-Smith P Gundle R Dodd D Murray D O’Connor J Goodfellow J
Full Access

Purpose: As part of the step-wise introduction of a meniscal-bearing total knee replacement (Oxford TMK) we needed to know, before proceeding to longer term studies, whether its early clinical results were at least as good as those of an established fixed bearing device (AGC).

Material and Methods: With ethical approval, patients requiring bilateral knee replacement for osteoarthritis consented to have the operations under one anaesthetic using one of each prosthesis; to accept random choice of knee; and to remain ignorant which side was which. American Knee Society Scores, Oxford Knee Scores, ROM and pain scores were to be recorded preoperatively and at one year. By January 2001, 40 patients had reached one year and data is available for 36.

Results: Preoperatively there was no difference between the two knees. One patient died in the peri-operative period.

Results at one year (TMK first): AKSS(Knee) 91.6 / 84.1 (p=0.003), OKS 39.8 / 37.6 (p=0.006), ROM 104 / 104 (p=0.364), Pain (AKSS) 47.3 / 41.7 (p=0.01), Pain (OKS) 3.5 / 2.9 (p=0.006).

Conclusion: The TMK performed as well as the AGC. Its AKSS, OKS and pain scores were significantly better. We believe this controlled, blinded trial is the first to have compared the function of a new knee prosthesis with a standard implant before marketing; and the first to have demonstrated a significant clinical advantage for a meniscal-bearing over a fixed bearing TKR. The comparison of bilateral implants in the same patient can reveal significant differences while putting at risk many fewer subjects than would be needed for a classical twocohort RCT.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 156 - 157
1 Jul 2002
Beard DJ Murray DW Rees JL Price AJ Hambly PR Dodd CAF
Full Access

A pilot study was performed to assess the feasibility of discharging patients undergoing unicompartmental knee replacement (UKR) within a day of surgery; both clinical and administrative issues were examined.

Logistics and responsibilities were organised prior to the study. Representatives of anaesthetics, pain team, orthopaedics, admissions, bed management, nursing, theatres, physiotherapy, radiology and outpatients were involved. Patients with medial compartment osteoarthritis undergoing unicompartmental knee replacement who passed strict exclusion criteria were recruited. Factors included; unsuitable home situation (no phone, excessive stairs, no support person), low tolerance to NSAIDS, and not living within a 25 mile radius of the hospital. To date seven NHS patients (mean age 60 years) have been recruited. All patients underwent preoperative assessment and counselling. The mean preoperative Oxford Knee Score was 24/48, the mean Knee Society Score (KSS) was 43/100 and average pain score was 14/50 indicating all patients had significant dysfunction and pain before operation. Average knee flexion was 111° and the average flexion deformity was 5°.

Each patient had a medial UKR using the minimally invasive approach and then underwent the accelerated recovery program. The program included pain control, accelerated rehabilitation, dedicated instructions and self assessment. Post operative pain was controlled by an intra-operative infiltration of local anaesthetic around the knee and large doses of NSAIDs. All patients were mobilised on the day of surgery and all except one who was delayed for administrative reasons) were discharged the following day. Patients were discharged in an extension splint and provided with post operative instructions including an emergency back up telephone number. A designated clinician made regular contact with the patient at home to assess progress. Patients were then assessed in clinic at 6 days, 13 days, and 6 weeks after surgery.

Patients average pain scores at 7 days and 14 days were 2/10 and 2.2/10 respectively. At 6 week follow up the average knee flexion was 124° and average flexion deformity was 1°. All patients were walking independently and painfree. No complications were encountered except one patient required further manipulation for limited knee flexion.

The new pain control protocol permits early mobilisation and discharge for patients undergoing UKR. Potential benefits include increased patient comfort, functional rehabilitation, avoidance of hospital induced infection and substantial cost benefits to the NHS. The pilot study demonstrates that, provided adequate communication is maintained between involved personnel, the program is both practical and safe. It now is planned to implement the accelerated recovery program for UKR as routine.