header advert
Results 1 - 23 of 23
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 38 - 45
1 Jan 2024
Leal J Mirza B Davies L Fletcher H Stokes J Cook JA Price A Beard DJ

Aims

The aim of this study was to estimate the incremental use of resources, costs, and quality of life outcomes associated with surgical reconstruction compared to rehabilitation for long-standing anterior cruciate ligament (ACL) injury in the NHS, and to estimate its cost-effectiveness.

Methods

A total of 316 patients were recruited and randomly assigned to either surgical reconstruction or rehabilitation (physiotherapy but with subsequent reconstruction permitted if instability persisted after treatment). Healthcare resource use and health-related quality of life data (EuroQol five-dimension five-level health questionnaire) were collected in the trial at six, 12, and 18 months using self-reported questionnaires and medical records. Using intention-to-treat analysis, differences in costs, and quality-adjusted life years (QALYs) between treatment arms were estimated adjusting for baseline differences and following multiple imputation of missing data. The incremental cost-effectiveness ratio (ICER) was estimated as the difference in costs divided by the difference in QALYs between reconstruction and rehabilitation.


Bone & Joint Research
Vol. 12, Issue 10 | Pages 624 - 635
4 Oct 2023
Harrison CJ Plessen CY Liegl G Rodrigues JN Sabah SA Beard DJ Fischer F

Aims

To map the Oxford Knee Score (OKS) and High Activity Arthroplasty Score (HAAS) items to a common scale, and to investigate the psychometric properties of this new scale for the measurement of knee health.

Methods

Patient-reported outcome measure (PROM) data measuring knee health were obtained from the NHS PROMs dataset and Total or Partial Knee Arthroplasty Trial (TOPKAT). Assumptions for common scale modelling were tested. A graded response model (fitted to OKS item responses in the NHS PROMs dataset) was used as an anchor to calibrate paired HAAS items from the TOPKAT dataset. Information curves for the combined OKS-HAAS model were plotted. Bland-Altman analysis was used to compare common scale scores derived from OKS and HAAS items. A conversion table was developed to map between HAAS, OKS, and the common scale.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 941 - 949
1 Jul 2020
Price AJ Kang S Cook JA Dakin H Blom A Arden N Fitzpatrick R Beard DJ

Aims

To calculate how the likelihood of obtaining measurable benefit from hip or knee arthroplasty varies with preoperative patient-reported scores.

Methods

Existing UK data from 222,933 knee and 209,760 hip arthroplasty patients were used to model an individual’s probability of gaining meaningful improvement after surgery based on their preoperative Oxford Knee or Hip Score (OKS/OHS). A clinically meaningful improvement after arthroplasty was defined as ≥ 8 point improvement in OHS, and ≥ 7 in OKS.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 652 - 659
1 Jun 2019
Abram SGF Beard DJ Price AJ

Aims

The aim of the British Association for Surgery of the Knee (BASK) Meniscal Consensus Project was to develop an evidence-based treatment guideline for patients with meniscal lesions of the knee.

Materials and Methods

A formal consensus process was undertaken applying nominal group, Delphi, and appropriateness methods. Consensus was first reached on the terminology relating to the definition, investigation, and classification of meniscal lesions. A series of simulated clinical scenarios was then created and the appropriateness of arthroscopic meniscal surgery or nonoperative treatment in each scenario was rated by the group. The process was informed throughout by the latest published, and previously unpublished, clinical and epidemiological evidence. Scenarios were then grouped together based upon the similarity of clinical features and ratings to form the guideline for treatment. Feedback on the draft guideline was sought from the entire membership of BASK before final revisions and approval by the consensus group.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 55 - 62
1 Jan 2019
Rombach I Merritt N Shirkey BA Rees JL Cook JA Cooper C Carr AJ Beard DJ Gray AM

Aims

The aims of this study were to compare the use of resources, costs, and quality of life outcomes associated with subacromial decompression, arthroscopy only (placebo surgery), and no treatment for subacromial pain in the United Kingdom National Health Service (NHS), and to estimate their cost-effectiveness.

Patients and Methods

The use of resources, costs, and quality-adjusted life-years (QALYs) were assessed in the trial at six months and one year. Results were extrapolated to two years after randomization. Differences between treatment arms, based on the intention-to-treat principle, were adjusted for covariates and missing data were handled using multiple imputation. Incremental cost-effectiveness ratios were calculated, with uncertainty around the values estimated using bootstrapping.


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 22 - 27
1 Oct 2016
Bottomley N Jones LD Rout R Alvand A Rombach I Evans T Jackson WFM Beard DJ Price AJ

Aims

The aim of this to study was to compare the previously unreported long-term survival outcome of the Oxford medial unicompartmental knee arthroplasty (UKA) performed by trainee surgeons and consultants.

Patients and Methods

We therefore identified a previously unreported cohort of 1084 knees in 947 patients who had a UKA inserted for anteromedial knee arthritis by consultants and surgeons in training, at a tertiary arthroplasty centre and performed survival analysis on the group with revision as the endpoint.


Bone & Joint Research
Vol. 3, Issue 11 | Pages 305 - 309
1 Nov 2014
Harris KK Price AJ Beard DJ Fitzpatrick R Jenkinson C Dawson J

Objective

The objective of this study was to explore dimensionality of the Oxford Hip Score (OHS) and examine whether self-reported pain and functioning can be distinguished in the form of subscales.

Methods

This was a secondary data analysis of the UK NHS hospital episode statistics/patient-reported outcome measures dataset containing pre-operative OHS scores on 97 487 patients who were undergoing hip replacement surgery.


Bone & Joint Research
Vol. 3, Issue 11 | Pages 321 - 327
1 Nov 2014
Palmer AJR Ayyar-Gupta V Dutton SJ Rombach I Cooper CD Pollard TC Hollinghurst D Taylor A Barker KL McNally EG Beard DJ Andrade AJ Carr AJ Glyn-Jones S

Aims

Femoroacetabular Junction Impingement (FAI) describes abnormalities in the shape of the femoral head–neck junction, or abnormalities in the orientation of the acetabulum. In the short term, FAI can give rise to pain and disability, and in the long-term it significantly increases the risk of developing osteoarthritis. The Femoroacetabular Impingement Trial (FAIT) aims to determine whether operative or non-operative intervention is more effective at improving symptoms and preventing the development and progression of osteoarthritis.

Methods

FAIT is a multicentre superiority parallel two-arm randomised controlled trial comparing physiotherapy and activity modification with arthroscopic surgery for the treatment of symptomatic FAI. Patients aged 18 to 60 with clinical and radiological evidence of FAI are eligible. Principal exclusion criteria include previous surgery to the index hip, established osteoarthritis (Kellgren–Lawrence ≥ 2), hip dysplasia (centre-edge angle < 20°), and completion of a physiotherapy programme targeting FAI within the previous 12 months. Recruitment will take place over 24 months and 120 patients will be randomised in a 1:1 ratio and followed up for three years. The two primary outcome measures are change in hip outcome score eight months post-randomisation (approximately six-months post-intervention initiation) and change in radiographic minimum joint space width 38 months post-randomisation. ClinicalTrials.gov: NCT01893034.

Cite this article: Bone Joint Res 2014;3:321–7.


Bone & Joint Research
Vol. 3, Issue 5 | Pages 155 - 160
1 May 2014
Carr AJ Rees JL Ramsay CR Fitzpatrick R Gray A Moser J Dawson J Bruhn H Cooper CD Beard DJ Campbell MK

This protocol describes a pragmatic multicentre randomised controlled trial (RCT) to assess the clinical and cost effectiveness of arthroscopic and open surgery in the management of rotator cuff tears. This trial began in 2007 and was modified in 2010, with the removal of a non-operative arm due to high rates of early crossover to surgery.

Cite this article: Bone Joint Res 2014;3:155–60.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 20 - 20
1 Apr 2013
Sonanis SV Kumar S Deshmukh N Wray C Beard DJ
Full Access

Introduction

A prospective study was done using Kirschner (K) wires to internally fix capitellum fractures and its results were analysed.

Materials/Methods

Since 1989, unstable displaced 17 capitellum fractures were anatomically reduced and internally fixed by inserting K wires in coronal plane from the capitellum into trochlea. The lateral end of wires were bent in form of a staple behind the fracture plane and anchored into the lateral humeral condyle with pre-drilled holes. Additional screws were used in 2 cases to stabilise the lateral pillar comminution. The capitellum was exposed with a limited modified lateral elbow approach between anconeus and extensor carpi ulnaris. The capsule was reflected anteriorly to expose the capitellum and trochlea. The deeper dissection was limited anterior to lateral collateral ligament (LCL) keeping it intact. The capitellum fragment was reposition under the radial head and anatomically reduced by full flexion of elbow and then internally fixed. Total 17 patients (7 males and 10 females) with average ages 34.8 years(14 to 75) had fractures, Type I: (Hans Steinthal #) 12, Type II: (Kocher Lorez #) 1, and Type III: (Broberg and Morrey #) 4. Post-operatively the patients were not given any immobilisation and were mobilised immediately.


Bone & Joint Research
Vol. 2, Issue 2 | Pages 33 - 40
1 Feb 2013
Palmer AJR Thomas GER Pollard TCB Rombach I Taylor A Arden N Beard DJ Andrade AJ Carr AJ Glyn-Jones S

Objectives

The number of surgical procedures performed each year to treat femoroacetabular impingement (FAI) continues to rise. Although there is evidence that surgery can improve symptoms in the short-term, there is no evidence that it slows the development of osteoarthritis (OA). We performed a feasibility study to determine whether patient and surgeon opinion was permissive for a Randomised Controlled Trial (RCT) comparing operative with non-operative treatment for FAI.

Methods

Surgeon opinion was obtained using validated questionnaires at a Specialist Hip Meeting (n = 61, 30 of whom stated that they routinely performed FAI surgery) and patient opinion was obtained from clinical patients with a new diagnosis of FAI (n = 31).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 74 - 74
1 Jul 2012
Al-Ali S Alvand A Gill HS Beard DJ Jackson W Price AJ Rees JL
Full Access

Rheumatology and Musculoskeletal Sciences, NIHR Biomedical Research Unit, University of Oxford and the Nuffield Orthopaedic Hospital, Oxford

Purpose

The aim of this study was to use motion analysis to objectively study the learning curve of surgical trainees performing arthroscopic meniscal repair on a training model in a skills laboratory.

Background

With improving technology and an appreciation of its likely chondroprotective effects, meniscal repair surgery is becoming more common. It remains a difficult procedure and is not routinely learnt during surgical training.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 80 - 80
1 May 2012
Thomas GER Simpson DJ Gill HS Glyn-Jones S Beard DJ Murray DW EPOS study group
Full Access

Femoral stem varus has been associated with poorer results. We report the incidence of varus/valgus malalignment of the Exeter polished, double taper design in a multicentre prospective study. The surgical outcomes at a minimum of five year and complication rates are also reported.

A multicentre prospective study of 987 total hip replacements was undertaken to investigate whether there is an association between surgical outcome and femoral stem malalignment. The primary outcome measure was the change in the Oxford hip score (OHS) at five years. Secondary outcomes included the rate of dislocation and revision.

The incidence of varus and valgus malignment were 7.1% and 2.6% respectively. There was no significant difference in OHS between neutral and malaligned femoral stems at 5 years (neutral, mean = 40.2; varus, mean 39.3, p = 0.465; valgus, mean = 40.9, p = 0.605). There was no significant difference in dislocation rate between the groups (p = 0.66). There was also no significant difference in revision rate (p = 0.34).

This study provides evidence that the Exeter stem is extremely tolerant of varus and valgus malalignment, both in terms of outcome and complication rate.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 421 - 421
1 Jul 2010
Monk AP Simpson DJ Ostlere S Dodd CAF Doll H Price AJ Beard DJ Gill HS Murray DW Gibbons CLMH
Full Access

Introduction: Patellofemoral joint subluxation is associated with pain and dysfunction. The causes of patel-lofemoral subluxation are poorly understood and multi-factorial, arising from abnormalities of both bone and soft tissues. This study aims to identify which anatomical variables assessed on Magnetic Resonance (MR) images are most relevant to patellofemoral subluxation.

Method: A retrospective analysis of MR studies of 60 patients with suspected patellofemoral subluxation was performed. All patients were graded for the severity/ magnitude of radiological subluxation using a dynamic MR scan (Grade 0 [nil] to Grade 3 [subluxed]. The patient scans were assessed using a range of anatomical variables, these included:

Patella alta,

Patella type (Wiberg classification),

Trochlea sulcus angles for bone and cartilage,

The shortest horizontal distance between the most distal part of the vastus medialis obliquis (VMO) muscle to the supra-medial aspect of the patella,

Trochlea and patella cartilage thickness (maximum depth),

The horizontal distance between the tibial tubercle and the midpoint of the femoral trochlea (TTD),

Patella Engagement – represented as the percentage of the patella height that is captured in the trochlea groove when the knee is in full extension,

A Discriminant Analysis test for multi-variant analysis was applied to establish the relationship between each bony/soft tissue anatomical variable and the severity/magnitude of patellofemoral subluxation.

Results: The distance of the VMO from the patella (p < 0.001), TTD (p < 0.001) and Patella Engagement (p < 0.001) showed highly significant relationships with patellofemoral subluxation.

Conclusions: The following three anatomical variables are associated with patellofemoral subluxation: the distance of the VMO muscle from the patella, TTD and Patella Engagement.

This is the first study to establish that patella engagement is related to PFJ subluxation showing that the lower the percentage engagement of the patella in the trochlea, the greater the severity/magnitude of patellofemoral subluxation. The finding provides greater insight into the aetiology and understanding of the mechanism of symptomatic PFJ subluxation.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 411 - 412
1 Sep 2009
Chau R Gulati A Pandit HG Beard DJ Gill HS Dodd CAF Simpson DJ Murray DW
Full Access

Purpose: To evaluate the effects of underhanging/overhanging tibial components on clinical outcome following the Oxford unicompartmental knee arthroplasty (UKA), and to identify an acceptable sizing limit.

Method: One hundred and sixty-three knees which had undergone the Phase 3 medial Oxford UKA (Biomet, Swindon) were measured. Based on five-year post-operative radiographs, they were divided into groups with tibial component underhang (n=38), none or minimal overhang of less than three millimetres (n=121), and a group with overhang equal to or in excess of three millimetres (n=13). Clinical outcome was assessed by changes in the twelve-question Oxford Knee Score (ΔOKS) and pain score (ΔPS) component (questions 1,4,5,8,9) from pre-operative assessment to five years following surgery.

Results: At five years after surgery, ΔOKS was significantly worse in the overhang group compared to both the neutral and underhang groups (p=0.015, and p=0.028 respectively). ΔPS was also shown to be significantly worse between the overhang and the neutral group (p=0.026 respectively).

Conclusion: Appropriate sizing of the tibial component is essential to optimise load bearing in total knee arthroplasty. In UKA such sizing is critical due to halving of the bony support for the tibial component and the lack of room for a large stem. Excessive undersizing of the prosthesis may lead to subsidence and loosening, whilst excessive overhanging may cause local soft tissue irritation and pain.

This study demonstrates that medial overhang of less than three millimetres for the tibial component is acceptable in the Oxford UKA. Excessive overhang equal to this or more results in significantly worse ΔOKS and ΔPS. However, no difference in the five year ΔOKS and ΔPS was demonstrated between underhang and the other two groups in this study.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 412 - 412
1 Sep 2009
Gulati A Jenkins C Chau R Pandit HG Dodd CAF Price AJ Simpson DJ Beard DJ Gill HS Murray DW
Full Access

Purpose: Varus deformity after total knee replacement (TKR) is associated with poor outcome. This aim of this study was to determine whether the same is true for medial unicompartmental arthroplasty (UKA).

Methods: 158 patients implanted with the Oxford UKA, using a minimally invasive approach, were studied prospectively for five years. Leg alignment was measured with a long-arm goniometer referenced from Anterior Superior Iliac Spine, centre of patella and centre of ankle. Patients were grouped according to the American Knee Society Score (AKSS). Group A: > 0° varus (n=13, 8.2%); Group B: 0 to 4° valgus (n=39, 24.7%); Group C: 5–10° valgus (normal alignment, n=106, 67.12%). Comparisons were made between the three groups in terms of the absolute and the change in Oxford Knee Score (OKS) and AKSS over the five year period, and the presence of radiolucency.

Results: There was no significant difference in any outcome measure except for Objective-AKSS (p< 0.001). The means and standard deviations of the ΔOKS for the groups were:

24 ± 5,

22 ± 10, and

22 ± 9 and for Objective-AKSS were 84 ± 12, 82 ± 15 and 91 ± 11 respectively.

The frequency of five year radiolucency for the groups A, B, and C were 42%, 35%, and 45% respectively.

Conclusion: The aim of the Oxford UKA is to restore knee kinematics and thus knee alignment to the pre-disease state. Therefore, as demonstrated by this study, about 30% of patients have varus alignment. This study also demonstrates that post-operative varus alignment does not compromise the outcome. The only score which did show worse outcome was the Objective-AKSS. This is because 10 or 20 points are deducted for varus alignment, which is not appropriate following UKA. Therefore, AKSS in its present form is not a reliable tool for assessment of UKA.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 421 - 421
1 Sep 2009
Chau R Pandit HG Gulati A Gray H Beard DJ Gill HS Dodd CAF Price AJ Murray DW
Full Access

Purpose: To identify associative factors for radiolucency (RL) under the tibial component following the Oxford unicompartmental arthroplasty (UKA), and to evaluate its effect on clinical outcome scores.

Method: One hundred and sixty-one knees which had undergone primary Phase 3 medial Oxford UKA were included. Fluoroscopic radiography films were assessed at five years post-operatively for areas of tibial RL. The two groups of patients, with and without RL, were compared to

patients’ pre-operative demographics for age, weight, height, BMI,

intra-operative variables such as the operating surgeon (n=2), insert and component sizes,

post-operative varus/valgus deformity, and

clinical outcome, assessed by the change in Oxford knee (OKS) and Tegner (TS) scores, from before surgery to five-year post-operatively.

Results: 101 (62%) knees were found to have tibial RL. All RL were categorised as physiological or they were < 1mm thick, with sclerotic margins and non-progressive. No statistical difference was found between knees with RL and those without, in terms of pre-operative demographics, intra- or post-operative factors, and clinical outcome scores (p> 0.1 in all variables).

Discussion: Radiolucency (RL) under the tibial component is a common finding following the Oxford UKA. Many theories have been proposed to explain the cause of RL, such as poor cementing, osteonecrosis, micromotion, and thermal necrosis. However, the true aetiology and clinical significance remain unclear. We attempted to address this.

We found no significant relationship between physiological RL, pre-operative demographics, intra-operative variables and clinical outcome scores in this study. Tibial RL remains a common finding following the Oxford UKA yet we do not know why it occurs but in the medium term, clinical outcome is not influenced by RL. In particular, it is not a sign of loosening. Physiological RL can therefore be ignored even if associated with adverse symptoms following the Oxford UKA.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 439 - 439
1 Apr 2004
Rees JL Price AJ Beard DJ McLardy-Smith P Dodd CAF Murray DW
Full Access

Introduction: A new procedure has been recently adopted to implant the Oxford medial unicompartmental arthroplasty (UCA). All cases are now implanted through a short incision without dislocation of the patella. The aims of this study were to assess the one-year results using this new technique and to determine if the outcome is dependent on surgical experience.

Method: The first 104 Oxford UCA’s (Phase 3) implanted by six surgeons under the care of two consultants were reviewed at one year. All operations were performed using the new technique. The average age at surgery was 68 years. All knees were scored pre-operatively and at review with the American Knee Society score. The cohort was divided into two groups; the first ten cases for each surgeon were included in a ‘learning’ group, whilst the remaining cases were included in an ‘experienced’ group.

Results: Overall the average ‘knee score’ improved from 37 points to 94 and the average ‘functional score’ from 50 points to 92. Average maximum flexion improved from 117° to 131°. The ‘knee score’ for the ‘learning’ group was 91 points. This was significantly less (p = 0.008) than the score of the ‘experienced’ group (96 points).

Conclusions: These results are significantly better than the best historical results of the Oxford (UCA), performed through an open approach with dislocation of the patella.

Despite impressive overall results at one year, lower knee scores were associated with a surgeons ‘learning curve’. After this ‘learning curve’, increased surgical experience led to further improvement with 90% achieving an excellent result, 8% a good, 2% a fair and 0% a poor result.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 55 - 55
1 Jan 2003
Rees JL Beard DJ Price AJ Gill HS Dodd CAF Murray DW
Full Access

Introduction: In conjunction with a bilateral randomised control trial comparing the clinical outcome of two total knee arthroplasties (TKA), we carried out an in-vivo fluoroscopic analysis of both knees in the trial. Knee A, is a new mobile bearing posterior cruciate retaining TKA and Knee B, an established fixed bearing posterior cruciate retaining TKA.

Method: In an ethically approved study, video fluoroscopy was taken of both knees of seven patients performing three exercises; extension against gravity, flexion against gravity and a step up exercise. Ten images at ten-degree intervals over the flexion range were frame grabbed and digitised. The relationship of patella tendon angle (PTA) to knee flexion angle (KFA) was assessed using a newly developed computer system. Five normal knees in fit volunteers were also fluoroscoped and assessed.

Results: A similar pattern of results was obtai ed for all three exercises. Knee A behaved in a linear, more consistent fashion than Knee B, which behaved non-linearly. Analysis of variance showed this difference was significant for all three exercises (p < 0.039).

Conclusions: This bilateral study provides a powerful way of assessing the kinematics of two different knee implants. Knee A behaves in a linear predictable fashion that is nearer normal than Knee B. These results will be used in conjunction with a clinical outcome study and an RSA study to provide a complete assessment of a new TKA.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 52 - 53
1 Jan 2003
Rees JL Price AJ Beard DJ Robinson BJ Dodd CAF Murray DW
Full Access

Introduction: The Oxford medial unicompartmental arthroplasty (UCA) is now routinely performed through a short incision without Dislocation of the patella. The aim of this study was to assess the one-year results of this new technique to determine whether it enhances the quality of outcome, as well as the speed of its achievement.

Method: The first 88 consecutive Oxford UCA’s (Phase 3) implanted into 75 patients by two consultant surgeons were scored pre-operatively and at review with the American Knee Society Score. The average age of the patients was 68.1 years; the male to female ratio was 0.9 to 1.

Results: At review, one patient (one knee) had died and one knee had been revised for infection. The other patients (86 knees) were examined at a mean of 1.3 years from surgery. The average ‘knee score’ improved from 37 points to 95 and the average ‘functional score’ from 51 points to 93. Average maximum flexion improved from 117° to 132°. The ‘knee score’ outcome categories at review were 87% excellent, 8% good, 2.5% fair and 2.5% poor.

Conclusions: Historical comparison of these results with the best results of the Oxford UCA, performed through an open approach with dislocation of the patella, suggest that the minimally invasive approach, in addition to faster recovery, improves the quality of outcome at one year.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 53 - 53
1 Jan 2003
Beard DJ Isaac DL Webb JM Dodd CAF
Full Access

A randomised controlled trial was performed to compare the clinical outcome for the two commonest types of anterior cruciate ligament (ACL) reconstruction. Methods: Patients undergoing elective anterior cruciate reconstruction were randomised into one of two groups. Group PT underwent reconstruction using a patella tendon autograft (n=14), whereas Group SG had a semitendinosus/gracilis autograft (n=18). The same surgeon performed all operations. IKDC self reported function and activity scores were recorded pre-operatively and at one and five years post operation. KT1000 values and muscle strength were recorded pre-operatively and one year post operation.

Results: No significant difference between groups was found for any measurement at one year despite adequate study power. At five year follow up patients in the PT group had superior scores in every category of the IKDC self reported function score (mean IKDC score for PT group = 83, mean IKDC score for SG = 75). The activities of squatting and kneeling revealed the greatest difference between groups. It was found that 71% of patients in the PT group achieved IKDC scores of 80 or over whereas only 61% of patients in the SG group achieved 1 KDC scores of 80 or over.

Conclusion: The study indicates that both techniques produce acceptable outcome for anterior cruciate ligament reconstruction but use of the patella tendon autograft may provide slightly more favourable results, especially for activities involving squatting and kneeling.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 320 - 320
1 Nov 2002
Isaac DL Beard DJ Price AJ Murray D
Full Access

Aim: This study was designed to investigate the nature and extent of tibial translation (TT) during open kinetic chain (OKC) and closed kinetic chain (CKC) activity; recent reports have suggested that the anterior cruciate ligament (ACL) may be strained to an equal amount during CKC and OKC exercise.

Method: Fifteen unilaterally ACL deficient (ACLD) patients and six control subjects underwent fluoroscopic assessment while performing a passive extension exercise, an OKC resisted extension exercise, and a weight-bearing CKC exercise designed to reflect knee motion experienced during dynamic daily activity. Measurements of the patella tendon angle (the angle between the long axis of the tibia and the patella tendon) were obtained to calculate relative TT.

Results: The results show that in ACL intact (ACLI) knees the CKC exercise caused greater anterior TT than the OKC exercise from 0 to 60° of knee flexion (p< 0.05). No difference between ACLI and ACLD knees was detected during the CKC exercise. Maximum weight-bearing (CKC) TT was 8±3 mm. The ACLD tibia during the OKC exercise translated more than the ACLI tibia, and to the same extent as the CKC exercise at 10 to 200 of knee flexion. The ACLI tibia during OKC exercise translated to a maximum of 3±4 mm at 1 0° knee flexion.

Summary: This study has demonstrated that fluoroscopic analysis may be used to detect differences in the kinematics of ACLI and ACLD limbs during activity. It validates recent data demonstrating that the ACL may be strained during CKC exercise to an equal or greater amount than during OKC exercise, and shows that the ACLD knee kinematics are similar to the ACLI knee during CKC exercise. Factors other than the ACL may control the extent of maximal TT during weightbearing activity. This has important consequences for the development of rehabilitation regimes after ACL reconstruction. The commonly held assumption that CKC exercise will protect an ACL graft may not be valid.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 156 - 157
1 Jul 2002
Beard DJ Murray DW Rees JL Price AJ Hambly PR Dodd CAF
Full Access

A pilot study was performed to assess the feasibility of discharging patients undergoing unicompartmental knee replacement (UKR) within a day of surgery; both clinical and administrative issues were examined.

Logistics and responsibilities were organised prior to the study. Representatives of anaesthetics, pain team, orthopaedics, admissions, bed management, nursing, theatres, physiotherapy, radiology and outpatients were involved. Patients with medial compartment osteoarthritis undergoing unicompartmental knee replacement who passed strict exclusion criteria were recruited. Factors included; unsuitable home situation (no phone, excessive stairs, no support person), low tolerance to NSAIDS, and not living within a 25 mile radius of the hospital. To date seven NHS patients (mean age 60 years) have been recruited. All patients underwent preoperative assessment and counselling. The mean preoperative Oxford Knee Score was 24/48, the mean Knee Society Score (KSS) was 43/100 and average pain score was 14/50 indicating all patients had significant dysfunction and pain before operation. Average knee flexion was 111° and the average flexion deformity was 5°.

Each patient had a medial UKR using the minimally invasive approach and then underwent the accelerated recovery program. The program included pain control, accelerated rehabilitation, dedicated instructions and self assessment. Post operative pain was controlled by an intra-operative infiltration of local anaesthetic around the knee and large doses of NSAIDs. All patients were mobilised on the day of surgery and all except one who was delayed for administrative reasons) were discharged the following day. Patients were discharged in an extension splint and provided with post operative instructions including an emergency back up telephone number. A designated clinician made regular contact with the patient at home to assess progress. Patients were then assessed in clinic at 6 days, 13 days, and 6 weeks after surgery.

Patients average pain scores at 7 days and 14 days were 2/10 and 2.2/10 respectively. At 6 week follow up the average knee flexion was 124° and average flexion deformity was 1°. All patients were walking independently and painfree. No complications were encountered except one patient required further manipulation for limited knee flexion.

The new pain control protocol permits early mobilisation and discharge for patients undergoing UKR. Potential benefits include increased patient comfort, functional rehabilitation, avoidance of hospital induced infection and substantial cost benefits to the NHS. The pilot study demonstrates that, provided adequate communication is maintained between involved personnel, the program is both practical and safe. It now is planned to implement the accelerated recovery program for UKR as routine.