Functional Relevance of Patellofemoral Thickness Before and After Unicompartmental Patellofemoral Replacement

The International Society for Technology in Arthroplasty (ISTA)



Abstract

The aim of this study was to assess the increase in the anterior diameter of the knee and the impact of this increase on the range of motion and function of the knee.

Twenty-eight patients (34 knees) who underwent Patello-femoral replacement with FPV (Wright Medical) prosthesis between 2005 and 2009 who were identified retrospectively and analyzed using chart and radiological review. Oxford and AKSS knee-scores were gathered prospectively pre-operative and at follow-up.

Trochlear height was measured using lateral radiograph. Trochlear height was compared pre and postoperatively. Patellar height was also measured in preoperative and postoperative skyline view and was compared. The range of movement at six weeks and the Oxford and American knee society knee scores at six months postoperatively were noted. Association between increased anterior height and improved range of motion was studied.

All but three-knees regained full knee extension. Postoperative mean range of flexion of the knee joint was 116 degrees. The mean Oxford knee and the mean American Knee Society Knee Scores significantly improved post-operatively

The trochlear height was increased by 4mms. Patellar height was also increased by 3 mms resulting in average total increase of 7 mms in the anterior-posterior diameter of the knee. We found no relationship between range of motion of the knee and the increase in the anterior-posterior diameter. We found a negative correlation between increase in the antero-posterior and preoperative trochlear and patellar height.

We conclude that FPV Patello-femoral replacement results in correct anatomical reconstruction of the trochlear height rather than ‘overstuffing’ of the patellofemoral joint which can lead to stiffness and failure of resolution of pain post-operatively. This should in turn result in durable improvements in pain and function.