header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

Restoration of Vertical and Horizontal Offset Using Dual Offset Stem in Korean

The International Society for Technology in Arthroplasty (ISTA)



Abstract

Purpose

The ultimate goal in total hip arthroplasty is not only to relieve the pain but also to restore original hip joint biomechanics. The average femoral neck-shaft angle(FNSA) in Korean tend to have more varus pattern. Since most of conventional femoral stems have relatively high, single, fixed neck shaft angle, it's not easy to restore vertical and horizontal offset exactly especially in Korean people. This study demonstrates the advantages of dual offset(especially high-offset) stem for restoring original biomechanics of hip joint during the total hip arthroplasty in Korean.

Materials and Methods

180 hips of 155 patients who underwent total hip arthroplasty using one of the standard(132°) or extended(127°) offset Accolade cementless stems were evaluated retrospectively. Offset of stem was chosen according to the patient's own FNSA in preoperative templating. In a morphometric study, neck-shaft angle of proximal femur, vertical offset and horizontal offset, abductor moment arm were measured on preoperative and postoperative both hip AP radiographs and the differences and correlation of each parameters, between operated hip and original non-operated hip which had no deformity (preoperative ipsilateral or postoperative contralateral hip), were analyzed.

Results

The standard stems were used in 34 hips and extended offset stems were used in 146 hips. The FNSA of non-operated hip was an average of 129.8°(127.2°□135.8°) in standard group and mean 125.4°(122.7°□129.9°) in extended offset group. The FNSA of operated hip was an average of 131.6° and 127.1° in each group. In the statistical analysis, there was no significant difference of mean horizontal and abductor moment arm between operated hip and non-operated hip in both groups and the restoration of horizontal offset and abductor moment arm showed(p=0.217, p=0.093) significant positive correlation(R=0.870, R=0.851) to the original value. However, vertical offset was increased an average of 1.4mm in operated hip and there was statistical significance. Restoration of vertical offset showed positive correlation to original value (R=0.845).

Conclusion

Dual- or multi-offset stem, especially extended offset stem can provide easy restoration of hip biomechanics and soft tissue tension without significant alteration of leg length especially in Korean with more varus femoral neck compared to Caucacian. Precise radiographic measurements of original hip and application of proper-offset stem should be taken in order to restore ideal hip biomechanics successfully and easily. A use of a proper offset stem can afford to enhance joint stability and implant longevity by improving soft-tissue tension and reducing resultant force, and it will guarantee a successful results after total hip arthroplasty in the aspect of function and longevity.


Email: