header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

Robotic Assisted Spinal Surgery - 2 Years of Clinical Experience - Gains and Disadvantages

The International Society for Technology in Arthroplasty (ISTA)



Abstract

Introduction

Our clinic has started to use MAZOR's Spine-Assist(r) robotic device in routine spinal surgery practice since 2006. The use of this system is diverse and now applicable for Vertebroplasty, Biopsy procedures and different techniques of Spinal fusion. During this time our clinic performed near 150 robotic assisted surgeries. Amongst its benefits the system allows the reduction of the duration of fluoroscopic exposure in the OR, better accuracy due to computerized assisted planning and navigation, avoidance of human caused complications and a less traumatic procedure for the patient. On the other hand, the duration of the procedure is prolonged, the wound is subdued to a longer exposure in cases of the open surgery, and the operational cost is higher and requires a good trained medical staff.

Materials and Methods

In the last 2 years we have performed 56 robotic assisted Vertebroplasty procedures (research group). At the same time we have performed 44 non assisted Vertebroplasty procedures. There was a significant difference in the fluoroscopic time and subsequent exposure time to radiation between the groups: in the research group we used only an average of 3 seconds of staff fluoroscopic exposure (an average of 5 fluoroscopic images) compared to an average of 11 seconds of exposure (an average of 24 fluoroscopic images). Furthermore, we have successfully inserted more than 400 pedical screws with less than 1mm accuracy from planning, out which only 8 were misplaced. Subsequently we have also performed 16 biopsies, which were effective as CT based biopsies. The average duration of a surgical procedure without the use of the system in 1 level fusion was 82 min. With the use of the system the average time was 106 min. The operational cost with the use of the system was about 1,000 ∊ more expensive. Furthermore, the use of the system required performing of an additional CT scan with 1 mm slices, which caused an additional exposure to patient radiation.

Results

Robotic assisted spinal surgery is a new and safe approach aiming to dramatically shorten the duration of fluoroscopic exposure of the staff and surgeon thus reducing the exposure to radiogenic dose. This novel procedure, promotes a better accuracy with regard to Vertebroplasty, Spinal fusion, insertion of Pedical Screws and also for biopsies procedures. We continue to broaden the usage of the robotic assisted device to other fields of spinal surgery and to general orthopaedic surgery. However, we have to resolve some issues such as cost, operation time and less fluoroscopic exposure for the patient.


Email: