header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

OXFORD PHASE III UNICOMPARTMENTAL KNEE REPLACEMENT – PATIENTS SATISFACTION AND SHORT TERM RESULTS FROM THE TRENT ARTHROPLASTY AUDIT GROUP.



Abstract

Aim: To analyze early clinical outcome and patients satisfaction following Oxford phase 3 Unicompartmental Knee arthroplasty at a mean follow up of 30 months from a single centre in the Trent arthroplasty register.

Methods: Between 1999 and 2002, 180 Oxford phase 3-unicompartmental knees were implanted in 173 patients. Average age at operation was 66 years. All patients were assessed pre and post-operatively using Oxford Knee questionnaire. At a mean follow up of 30 months (range 12–48 months); ninety knees in 83 patients were assessed using Oxford and EuroQol health questionnaire. Subjective patient’s satisfaction was also assessed.

Results: Seven knees out of 180 were revised early in the series giving a failure rate of 4%. Three patients had died due to unrelated causes. 90 knees were assessed at recent follow-up. The mean Oxford knee score improved from 48 preoperatively to 28 post-operatively. Subjectively 76% of the patients felt that the operation was successful and 74% were able to resume their leisure activities with out any pain.

Conclusion: This study shows that the short-term results following minimally invasive Oxford phase 3-unicompartmental knee implantation technique can yield satisfactory clinical and functional results. Using stringent selection criteria, Oxford phase 3-unicompartmental knee offers a good alternative to total knee arthroplasty.

Honorary Secretary – Mr Roger Smith. Correspondence should be addressed to BASK at the Royal College of Surgeons, 35 - 43 Lincoln’s Inn Fields, London WC2A 3PN