Aims: Leg length discrepancy is a well-recognised complication after total hip arthroplasty. However, the effect of using a cemented or uncemented femoral component on leg length has not been previously investigated. The aim of our study was to assess leg length discrepancy following total hip arthroplasty using a cemented femoral component and to compare this with an uncemented femoral component.

Patients and method: We included 140 patients who had undergone a primary total hip arthroplasty in our study. All patients received an uncemented Duraloc acetabular cup (Depuy, Leeds, UK). Our uncemented group consisted of 70 consecutive patients who had received an uncemented Accolade femoral prosthesis (Depuy, Leeds, UK). Our cemented group included 70 patients who had received a cemented Ultima femoral prosthesis (Depuy, Leeds, UK). Leg lengths were measured from radiographs by two independent observers using a validated assessment method, pre-operatively and at six months post-operatively. Clinical outcome was assessed using Harris hip scores.

Results: The mean age of the patients was 68 years for the uncemented group and 56 years for the cemented group. The overall leg length discrepancy was mean 5.7mm (range 0 to 26mm). The uncemented group had an increase in leg length discrepancy post-operatively compared to the cemented group (6.4mm vs 4.2mm), p< 0.05. There was no significant difference in Harris hip scores between the uncemented and cemented groups either pre-operatively (37.4 vs 38.7) or at 6 months postoperatively (77.9 vs 78.7 respectively).

Conclusion: We found a significant increase in leg length discrepancy after total hip arthroplasty using an uncemented femoral prosthesis compared with a cemented femoral prosthesis. This was detectable radiologically but did not affect clinical outcome. Patients should be informed about the risk of leg length discrepancy before total hip arthroplasty particularly if an uncemented femoral prosthesis is used.