EXETER VERSUS ULTIMA-TPS FEMORAL STEM: A RANDOMISED EARLY OUTCOMES STUDY



Abstract

The Exeter (Howmedica Ltd) and Ultima-TPS (Depuy Ltd) implants are both collarless, polished, double-tapered, cemented femoral implants. The Exeter is manufactured in stainless steel and has an excellent long-term survivorship. The Ultima-TPS is manufactured in cobalt-chrome and has been recently introduced. The aim of this study was to compare the early performance of these implants in a 2-year randomised clinical trial.

65 patients with unilateral hip osteoarthritis were randomised to receive either the Exeter or TPS stem. All received a Charnley Cup. Outcome measures included the Oxford Hip Questionnaire, proximal femoral bone mineral density (BMD) measured by dual energy x-ray absorptiometry, and implant subsidence measured using EBRA. At 2 years 43 patients (66%) were reviewed. 22 patients (mean age 70 years, 16 female, BMI 27.9Kg/m2) received the TPS implant, and 21 patients (mean age 70 years, 15 female, BMI 28.9Kg/m2) received the Exeter implant. 19 patients withdrew for reasons unrelated to the study, 2 died, and 1 was withdrawn after deep wound infection.

Complete Oxford hip scores were available pre-operatively and at 2 years in 37 patients (n=20 TPS). Median (IQR) pre-operative hip scores were 51 (43 to 54) and 48 (36 to 53) for the TPS and Exeter implants, respectively. At 2 years the hip scores improved to 24 (18 to 31) and 22 (16 to 31), respectively. There were no differences in scores between groups at each time-point. There were no differences in BMD between groups at pre-operative baseline, 3 months, 1 and 2 years (Gruen zones 1–7, all time-points; n=19 TPS, n=13 Exeter implants: P> 0.05). Maximum bone loss was seen in Gruen zone 7 at 2 years for bone implants (TPS-11%, Exeter -14%, P> 0.05). Measurement of subsidence over 2 years using EBRA was possible in 20 patients (n=7 TPS, n=13 Exeter). Mean subsidence at 2 years was 1.62mm for the TPS implant and 1.60mm for the Exeter implant (P> 0.05). There was no plain radiographic evidence of osteolysis in either group.

These data suggest that the early performance of the two implants studied is similar. However, long-term survivorship data is required to confirm their equivalency.

Editoral Secretary Mr Peter Howard. Correspondence should be addressed to BHS at the Royal College of Surgeons, 35 - 43 Lincoln’s Inn Fields, London WC2A 3PN.