header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

POSTERIOR HIP DISLOCATION WITH A LABRAL TEAR: TREATMENT WITH SUTURES OVER A BUTTRESS PLATE



Abstract

We treated 133 traumatic posterior dislocations surgically between July 1994 and March 2001. In 16 patients, labral tears had occurred.

Operating on posterior hip dislocations, initially we fixated the posterior wall with screws and/or buttress plate, depending on the size of the fragment, and did suture the torn labrum, relying rather on the buttress plate or intact posterior wall for stability.

We began repairing the torn labrum when we realised that any small fragments still attached to the labrum simply pull out from under the buttress plate, allowing the hip to redislocate. Once the wall has been reconstructed, interrupted sutures are passed through the labrum, with the hip internally rotated to prevent shortening of the capsule when sutures are tied. A one-third tubular plate is placed over the sutures lying on the posterior wall and fixed with screws. The sutures are then tied individually over the plate. Postoperatively the patient is kept in bed for six weeks, with the hip abducted and knee extended.

Seven patients in whom the labrum was not repaired experienced redislocation. We performed second operations on two of them, repositioning the plates and reconstructing the posterior wall, but redislocation again occurred. The redislocated femoral heads were damaged because they rubbed against the plate and screws. In the other nine patients, we sutured the labrum, and in a 3 month to 2.5 year follow-up, no redislocation has occurred. .

Labral repair restores stability, and tying interrupted sutures over a buttress plate is an easy and effective method of repair.

The abstracts were prepared by Professor M. B. E. Sweet. Correspondence should be addressed to him at The Department of Orthopaedic Surgery, Medical School, University of Witwatersrand, 7 York Road, Parktown, Johannesburg, 2193 South Africa