header advert
You currently have no access to view or download this content. Please log in with your institutional or personal account if you should have access to through either of these
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Get Access locked padlock

Children's Orthopaedics

HIP ABNORMALITIES DETECTED BY ULTRASOUND IN CLINICALLY NORMAL NEWBORN INFANTS



Download PDF

Abstract

We have followed the natural progress of newborn infants in whom ultrasound examination showed abnormalities in hips which appeared to be clinically normal. Over six years we saw 306 such children out of 9952 examined (31 per 1000 live births). The examination was repeated at two to three months and those who still showed an abnormality were followed up further.

At four to five months a standard radiograph was obtained, and treatment began if this and another ultrasound scan were both abnormal. At this stage, 291 infants had normal hips. In the 15 infants with abnormal hips there was no pronounced deterioration, none developed a frank dislocation, and all became normal after treatment in an abduction splint.

Newborn infants with abnormal and suspicious ultrasound findings who are normal on clinical examination do not need treatment from birth; most of these hips will settle spontaneously. Treatment can be postponed until the age of four to five months unless clinical instability develops or ultrasound shows dislocation. The criteria for treatment should be based on measurements by both ultrasound and radiography: both should show an abnormality before intervention is considered necessary.


Correspondence should be sent to Dr T. Terjesen at the National Hospital, Trondheimsv. 132, N-0570 Oslo, Norway.

For access options please click here