header advert
You currently have no access to view or download this content. Please log in with your institutional or personal account if you should have access to through either of these
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Get Access locked padlock

Prophylaxis against deep-vein thrombosis in total hip replacement. Comparison of heparin and foot impulse pump



Download PDF

Abstract

We performed a randomised controlled study to compare heparin with the A-V Impulse System in the prevention of deep-vein thrombosis (DVT) in 132 consecutive patients undergoing total hip replacement. After the operation, all patients had compression stockings, 65 were treated with calcium heparin and 67 with the intermittent plantar pump. DVT was diagnosed by Doppler ultrasound and thermography, followed by phlebography. There were 23 cases of DVT (35.4%) in the heparin group, with 16 major and seven minor thromboses. In the impulse pump group there were nine cases (13.4%) with three major and six minor thromboses. The differences for all thromboses and for major thromboses were both significant at p < 0.005. In the heparin group there was one fatal pulmonary embolism and nine patients (13.8%) had excessive bleeding or wound haematomas, as against none in the impulse pump group.

For access options please click here