header advert
You currently have no access to view or download this content. Please log in with your institutional or personal account if you should have access to through either of these
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Get Access locked padlock

Wrist & Hand

The correlation between shape of the sigmoid notch of the distal radius and the risk of triangular fibrocartilage complex foveal tear



Download PDF

Abstract

Aims

The aim of this study was to analyze the association between the shape of the distal radius sigmoid notch and triangular fibrocartilage complex (TFCC) foveal tear.

Methods

Between 2013 and 2018, patients were retrospectively recruited in two different groups. The patient group comprised individuals who underwent arthroscopic transosseous TFCC foveal repair for foveal tear of the wrist. The control group comprised individuals presenting with various diseases around wrist not affecting the TFCC. The study recruited 176 patients (58 patients, 118 controls). The sigmoid notch shape was classified into four types (flat-face, C-, S-, and ski-slope types) and three radiological parameters related to the sigmoid notch (namely, the radius curvature, depth, and version angle) were measured. The association of radiological parameters and sigmoid notch types with the TFCC foveal tear was investigated in univariate and multivariate analyses. Receiver operating characteristic curves were used to estimate a cut-off for any statistically significant variables.

Results

Univariate analysis showed that the flat-face type was more prevalent in the patients than in the control group (43% vs 21%; p = 0.002), while the C-type was lower in the patients than in the control group (3% vs 17%; p = 0.011). The depth and version angle of sigmoid notch showed a negative association with the TFCC foveal tear in the multivariate analysis (depth: odds ratio (OR) 0.380; p = 0.037; version angle: OR 0.896; p = 0.033). Estimated cut-off values were 1.34 mm for the depth (area under the curve (AUC) = 0.725) and 10.45° for the version angle (AUC = 0.726).

Conclusion

The proportion of flat-face sigmoid notch type was greater in the patient group than in the control group. The depth and version angle of sigmoid notch were negatively associated with TFCC foveal injury.

Cite this article: Bone Joint J 2020;102-B(6):749–754.


Correspondence should be sent to Jae S. Lee; E-mail:

For access options please click here