Non-traumatic osteonecrosis of the femoral head is a potentially devastating condition, the prevalence of which is increasing. Many joint-preserving forms of treatment, both medical and surgical, have been developed in an attempt to slow or reverse its progression, as it usually affects young patients.

However, it is important to evaluate the best evidence that is available for the many forms of treatment considering the variation in the demographics of the patients, the methodology and the outcomes in the studies that have been published, so that it can be used effectively.

The purpose of this review, therefore, was to provide an up-to-date, evidence-based guide to the management, both non-operative and operative, of non-traumatic osteonecrosis of the femoral head.

Cite this article: Bone Joint J 2017;99-B:1267–79.


Episodic payments (bundling) Pages 1280 - 1285
Access Required
D. J. Jacofsky
View article
Download PDF

Episodic, or bundled payments, is a concept now familiar to most in the healthcare arena, but the models are often misunderstood. Under a traditional fee-for-service model, each provider bills separately for their services which creates financial incentives to maximise volumes. Under a bundled payment, a single entity, often referred to as a convener (maybe the hospital, the physician group, or a third party) assumes the risk through a payer contract for all services provided within a defined episode of care, and receives a single (bundled) payment for all services provided for that episode. The time frame around the intervention is variable, but defined in advance, as are included and excluded costs. Timing of the actual payment in a bundle may either be before the episode occurs (prospective payment model), or after the end of the episode through a reconciliation (retrospective payment model). In either case, the defined costs over the defined time frame are borne by the convener.

Cite this article: Bone Joint J 2017;99-B:1280–5.


A. Rajpura T. N. Board P. D. Siney H. Wynn Jones S. Williams L. Dabbs B. M. Wroblewski
View article
Download PDF

Aims

Our aim in this study was to describe a continuing review of 11 total hip arthroplasties using 22.225 mm Alumina ceramic femoral heads on a Charnley flanged femoral component, articulating against a silane crosslinked polyethylene.

Patients and Methods

Nine patients (11 THAs) were reviewed at a mean of 27.5 years (26 to 28) post-operatively. Outcome was assessed using the d’Aubigne and Postel, and Charnley scores and penetration was recorded on radiographs. In addition, the oxidation of a 29-year-old shelf-aged acetabular component was analysed.


P. A. Devane J. G. Horne G. Foley J. Stanley
View article
Download PDF

Aims

This paper describes the methodology, validation and reliability of a new computer-assisted method which uses models of the patient’s bones and the components to measure their migration and polyethylene wear from radiographs after total hip arthroplasty (THA).

Materials and Methods

Models of the patient’s acetabular and femoral component obtained from the manufacturer and models of the patient’s pelvis and femur built from a single computed tomography (CT) scan, are used by a computer program to measure the migration of the components and the penetration of the femoral head from anteroposterior and lateral radiographs taken at follow-up visits. The program simulates the radiographic setup and matches the position and orientation of the models to outlines of the pelvis, the acetabular and femoral component, and femur on radiographs. Changes in position and orientation reflect the migration of the components and the penetration of the femoral head. Validation was performed using radiographs of phantoms simulating known migration and penetration, and the clinical feasibility of measuring migration was assessed in two patients.


R. Schouten A. A. Malone C. M. Frampton C. Tiffen G. Hooper
View article
Download PDF

Aims

The primary aim of this independent prospective randomised trial was to compare serum metal ion levels for ceramic-on-metal (CoM) and metal-on-metal (MoM) bearing surfaces in total hip arthroplasty (THA). Our one-year results demonstrated elevation in metal ion levels above baseline with no significant difference between the CoM and MoM groups. This paper reviews the five-year data.

Patients and Methods

The implants used in each patient differed only in respect to the type of femoral head (ceramic or metal). At five-year follow-up of the 83 enrolled patients, data from 67 (36 CoM, 31 MoM) was available for comparison.


D. J. Langton R. P. Sidaginamale T. J. Joyce R. D. Meek J. G. Bowsher D. Deehan A. V. F. Nargol J. P. Holland
View article
Download PDF

Aims

We sought to determine whether cobalt-chromium alloy (CoCr) femoral stem tapers (trunnions) wear more than titanium (Ti) alloy stem tapers (trunnions) when used in a large diameter (LD) metal-on-metal (MoM) hip arthroplasty system.

Patients and Methods

We performed explant analysis using validated methodology to determine the volumetric material loss at the taper surfaces of explanted LD CoCr MoM hip arthroplasties used with either a Ti alloy (n = 28) or CoCr femoral stem (n = 21). Only 12/14 taper constructs with a rough male taper surface and a nominal included angle close to 5.666° were included. Multiple regression modelling was undertaken using taper angle, taper roughness, bearing diameter (horizontal lever arm) as independent variables. Material loss was mapped using a coordinate measuring machine, profilometry and scanning electron microscopy.


R. Nakamura N. Komatsu K. Fujita K. Kuroda M. Takahashi R. Omi Y. Katsuki H. Tsuchiya
View article
Download PDF

Aims

Open wedge high tibial osteotomy (OWHTO) for medial-compartment osteoarthritis of the knee can be complicated by intra-operative lateral hinge fracture (LHF). We aimed to establish the relationship between hinge position and fracture types, and suggest an appropriate hinge position to reduce the risk of this complication.

Patients and Methods

Consecutive patients undergoing OWHTO were evaluated on coronal multiplanar reconstruction CT images. Hinge positions were divided into five zones in our new classification, by their relationship to the proximal tibiofibular joint (PTFJ). Fractures were classified into types I, II, and III according to the Takeuchi classification.


T. J. Shelton A. J. Nedopil S. M. Howell M. L. Hull
View article
Download PDF

Aims

The aims of this study were to determine the proportion of patients with outlier varus or valgus alignment in kinematically aligned total knee arthroplasty (TKA), whether those with outlier varus or valgus alignment have higher forces in the medial or lateral compartments of the knee than those with in-range alignment and whether measurements of the alignment of the limb, knee and components predict compartment forces.

Patients and Methods

The intra-operative forces in the medial and lateral compartments were measured with an instrumented tibial insert in 67 patients who underwent a kinematically aligned TKA during passive movement. The mean of the forces at full extension, 45° and 90° of flexion determined the force in the medial and lateral compartments. Measurements of the alignment of the limb and the components included the hip-knee-ankle (HKA) angle, proximal medial tibial angle (PMTA), and distal lateral femoral angle (DLFA). Measurements of the alignment of the knee and the components included the tibiofemoral angle (TFA), tibial component angle (TCA) and femoral component angle (FCA). Alignment was measured on post-operative, non-weight-bearing anteroposterior (AP) scanograms and categorised as varus or valgus outlier or in-range in relation to mechanically aligned criteria.


J. B. T. Lim H. C. Chong H. N. Pang K. J. D. Tay S. L. Chia N. N. Lo S. J. Yeo
View article
Download PDF

Aims

Little is known about the relative outcomes of revision of unicompartmental knee arthroplasty (UKA) and high tibial osteotomy (HTO) to total knee arthroplasty (TKA). The aim of this study is to compare the outcomes of revision surgery for the two procedures in terms of complications, re-revision and patient-reported outcome measures (PROMs) at a minimum of two years follow-up.

Patients and Methods

This study was a retrospective review of data from an institutional arthroplasty registry for cases performed between 2001 and 2014. A total of 292 patients were identified, of which 217 had a revision of HTO to TKA, and 75 had revision of UKA to TKA. While mean follow-up was longer for the HTO group compared with the UKA group, patient demographics (age, body mass index and Charlson co-morbidity index) and PROMs (Short Form-36, Oxford Knee Score, Knee Society Score, both objective and functional) were similar in the two groups prior to revision surgery. Outcomes included the rate of complications and re-operation, PROMS and patient-reported satisfaction at six months and two years post-operatively. We also compared the duration of surgery and the need for revision implants in the two groups.


S-D. Joo K-B. Lee
View article
Download PDF

Aims

The purpose of this study was to compare the clinical and radiographic outcomes of total ankle arthroplasty (TAA) in patients with pre-operatively moderate and severe arthritic varus ankles to those achieved for patients with neutral ankles.

Patients and Methods

A total of 105 patients (105 ankles), matched for age, gender, body mass index, and follow-up duration, were divided into three groups by pre-operative coronal plane tibiotalar angle; neutral (< 5°), moderate (5° to 15°) and severe (> 15°) varus deformity. American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, a visual analogue scale (VAS), and Short Form (SF)-36 score were used to compare the clinical outcomes after a mean follow-up period of 51 months (24 to 147).


M. A. Yalizis E. T. H. Ek H. Anderson G. Couzens G. A. Hoy
View article
Download PDF

Aims

To determine whether an early return to sport in professional Australian Rules Football players after fixation of a non-thumb metacarpal fracture was safe and effective.

Patients and Methods

A total of 16 patients with a mean age of 25 years (19 to 30) identified as having a non-thumb metacarpal fracture underwent open reduction and internal plate and screw fixation. We compared the players’ professional performance statistics before and after the injury to determine whether there was any deterioration in their post-operative performance.


C. Q. Y. Tang S. W. H. Lai S. C. Tay
View article
Download PDF

Aims

Few studies have examined the long-term outcome of carpal tunnel release (CTR). The aim of this study was to evaluate the patient-reported long-term outcome of CTR for electrophysiologically severe carpal tunnel syndrome (CTS).

Patients and Methods

We reviewed the long-term outcome of 40 patients with bilateral severe CTS who underwent 80 CTRs (46 open, 34 endoscopic) between 2002 and 2012. The outcomes studied were patient-reported outcomes of numbness resolution, the Boston Carpal Tunnel Questionnaire (BCTQ) score, and patient satisfaction.


S. Patrick A. McDowell A. Lee A. Frau U. Martin E. Gardner G. McLorinan N. Eames
View article
Download PDF

Aims

The aim of this study was to determine whether the sequential application of povidone iodine-alcohol (PVI) followed by chlorhexidine gluconate-alcohol (CHG) would reduce surgical wound contamination to a greater extent than PVI applied twice in patients undergoing spinal surgery.

Patients and Methods

A single-centre, interventional, two arm, parallel group randomised controlled trial was undertaken, involving 407 patients who underwent elective spinal surgery.

For 203 patients, the skin was disinfected before surgery using PVI (10% [w/w (1% w/w available iodine)] in 95% industrial denatured alcohol, povidone iodine; Videne Alcoholic Tincture) twice, and for 204 patients using PVI once followed by CHG (2% [w/v] chlorhexidine gluconate in 70% [v/v] isopropyl alcohol; Chloraprep with tint). The primary outcome measure was contamination of the wound determined by aerobic and anaerobic bacterial growth from samples taken after disinfection.


M. Rickert C. Fleege T. Tarhan S. Schreiner M. R. Makowski M. Rauschmann M. Arabmotlagh
View article
Download PDF

Aims

We compared the clinical and radiological outcomes of using a polyetheretherketone cage with (TiPEEK) and without a titanium coating (PEEK) for instrumented transforaminal lumbar interbody fusion (TLIF).

Materials and Methods

We conducted a randomised clinical pilot trial of 40 patients who were scheduled to undergo a TLIF procedure at one or two levels between L2 and L5. The Oswestry disability index (ODI), EuroQoL-5D, and back and leg pain were determined pre-operatively, and at three, six, and 12 months post-operatively. Fusion rates were assessed by thin slice CT at three months and by functional radiography at 12 months.


A. Rienmüller N. Buchmann J. S. Kirschke E. L. Meyer J. Gempt J. Lehmberg B. Meyer Y. M. Ryang
View article
Download PDF

Aims

We aimed to retrospectively assess the accuracy and safety of CT navigated pedicle screws and to compare accuracy in the cervical and thoracic spine (C2-T8) with (COMB) and without (POST) prior anterior surgery (anterior cervical discectomy or corpectomy and fusion with ventral plating: ACDF/ACCF).

Patients and Methods

A total of 592 pedicle screws, which were used in 107 consecutively operated patients (210 COMB, 382 POST), were analysed. The accuracy of positioning was determined according to the classification of Gertzbein and Robbins on post-operative CT scans.


Access Required
Y. W. Wong D. Samartzis K. M. C. Cheung K. Luk
View article
Download PDF

Aims

To address the natural history of severe post-tuberculous (TB) kyphosis, with focus upon the long-term neurological outcome, occurrence of restrictive lung disease, and the effect on life expectancy.

Patients and Methods

This is a retrospective clinical review of prospectively collected imaging data based at a single institute. A total of 24 patients of Southern Chinese origin who presented with spinal TB with a mean of 113° of kyphosis (65° to 159°) who fulfilled inclusion criteria were reviewed. Plain radiographs were used to assess the degree of spinal deformity. Myelography, CT and MRI were used when available to assess the integrity of the spinal cord and canal. Patient demographics, age of onset of spinal TB and interventions, types of surgical procedure, intra- and post-operative complications, and neurological status were assessed.


K. Stavem M. G. Naumann U. Sigurdsen S. E. Utvåg
View article
Download PDF

Aims

This study assessed the association of classes of body mass index in kg/m2 (classified as normal weight 18.5 kg/m2 to 24.9 kg/m2, overweight 25.0 kg/m2 to 29.9 kg/m2, and obese ≥ 30.0 kg/m2) with short-term complications and functional outcomes three to six years post-operatively for closed ankle fractures.

Patients and Methods

We performed a historical cohort study with chart review of 1011 patients who were treated for ankle fractures by open reduction and internal fixation in two hospitals, with a follow-up postal survey of 959 of the patients using three functional outcome scores.


C. E. H. Scott D. MacDonald M. Moran T. O. White J. T. Patton J. F. Keating
View article
Download PDF

Aims

To evaluate the outcomes of cemented total hip arthroplasty (THA) following a fracture of the acetabulum, with evaluation of risk factors and comparison with a patient group with no history of fracture.

Patients and Methods

Between 1992 and 2016, 49 patients (33 male) with mean age of 57 years (25 to 87) underwent cemented THA at a mean of 6.5 years (0.1 to 25) following acetabular fracture. A total of 38 had undergone surgical fixation and 11 had been treated non-operatively; 13 patients died at a mean of 10.2 years after THA (0.6 to 19). Patients were assessed pre-operatively, at one year and at final follow-up (mean 9.1 years, 0.5 to 23) using the Oxford Hip Score (OHS). Implant survivorship was assessed. An age and gender-matched cohort of THAs performed for non-traumatic osteoarthritis (OA) or avascular necrosis (AVN) (n = 98) were used to compare complications and patient-reported outcome measures (PROMs).