header advert
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Volume 90-B, Issue 6 June 2008

Review Article
Access Required
C. M. Robinson P. J. Jenkins P. E. Markham I. Beggs

The sternoclavicular joint is vulnerable to the same disease processes as other synovial joints, the most common of which are instability from injury, osteoarthritis, infection and rheumatoid disease. Patients may also present with other conditions, which are unique to the joint, or are manifestations of a systemic disease process. The surgeon should be aware of these possibilities when assessing a patient with a painful, swollen sternoclavicular joint.


Access Required
J. A. Fraser-Moodie N. L. Shortt C. M. Robinson

Injuries to the acromioclavicular joint are common but underdiagnosed. Sprains and minor subluxations are best managed conservatively, but there is debate concerning the treatment of complete dislocations and the more complex combined injuries in which other elements of the shoulder girdle are damaged. Confusion has been caused by existing systems for classification of these injuries, the plethora of available operative techniques and the lack of well-designed clinical trials comparing alternative methods of management. Recent advances in arthroscopic surgery have produced an even greater variety of surgical options for which, as yet, there are no objective data on outcome of high quality. We review the current concepts of the treatment of these injuries.


Hip
Access Required
C. W. McBryde E. Shears J. N. O’Hara P. B. Pynsent

Metal-on-metal hip resurfacing was performed for developmental dysplasia in 96 hips in 85 patients, 78 in women and 18 in men, with a mean age at the time of surgery of 43 years (14 to 65). These cases were matched for age, gender, operating surgeon and date of operation with a group of patients with primary osteoarthritis who had been treated by resurfacing, to provide a control group of 96 hips (93 patients). A clinical and radiological follow-up study was performed. The dysplasia group were followed for a mean of 4.4 years (2.0 to 8.5) and the osteoarthritis group for a mean of 4.5 years (2.2 to 9.4). Of the dysplasia cases, 17 (18%) were classified as Crowe grade III or IV.

There were five (5.2%) revisions in the dysplasia group and none in the osteoarthritic patients. Four of the failures were due to acetabular loosening and the other sustained a fracture of the neck of femur. There was a significant difference in survival between the two groups (p = 0.02). The five-year survival was 96.7% (95% confidence interval 90.0 to 100) for the dysplasia group and 100% (95% confidence interval 100 to 100) for the osteoarthritic group. There was no significant difference in the median Oxford hip score between the two groups at any time during the study.

The medium-term results of metal-on-metal hip resurfacing in all grades of developmental dysplasia are encouraging, although they are significantly worse than in a group of matched patients with osteoarthritis treated in the same manner.


D. J. W. McMinn J. Daniel H. Ziaee C. Pradhan

The dysplasia cup, which was devised as an adjunct to the Birmingham Hip Resurfacing system, has a hydroxyapatite-coated porous surface and two supplementary neutralisation screws to provide stable primary fixation, permit early weight-bearing, and allow incorporation of morcellised autograft without the need for structural bone grafting.

A total of 110 consecutive dysplasia resurfacing arthroplasties in 103 patients (55 men and 48 women) performed between 1997 and 2000 was reviewed with a minimum follow-up of six years. The mean age at operation was 47.2 years (21 to 62) and 104 hips (94%) were Crowe grade II or III.

During the mean follow-up of 7.8 years (6 to 9.6), three hips (2.7%) were converted to a total hip replacement at a mean of 3.9 years (2 months to 8.1 years), giving a cumulative survival of 95.2% at nine years (95% confidence interval 89 to 100). The revisions were due to a fracture of the femoral neck, a collapse of the femoral head and a deep infection. There was no aseptic loosening or osteolysis of the acetabular component associated with either of the revisions performed for failure of the femoral component. No patient is awaiting a revision.

The median Oxford hip score in 98 patients with surviving hips at the final review was 13 and the 10th and the 90th percentiles were 12 and 23, respectively.


G. Hartofilakidis G. Georgiades G. C. Babis C. K. Yiannakopoulos

We have evaluated the results of total hip replacement in patients with congenital hip disease using 46 cemented all-polyethylene Charnley acetabular components implanted with the cotyloplasty technique in 34 patients (group A), and compared them with 47 metal-backed cementless acetabular components implanted without bone grafting in 33 patients (group B). Patients in group A were treated between 1988 and 1993 and those in group B between 1990 and 1995. The mean follow-up for group A was 16.6 years (12 to 18) and the mean follow-up for group B was 13.4 years (10 to 16).

Revision for aseptic loosening was undertaken in 15 hips (32.6%) in group A and in four hips (8.5%) in group B. When liner exchange was included, a total of 13 hips were revised in group B (27.7%). The mean polyethylene wear was 0.11 mm/yr (0.002 to 0.43) and 0.107 mm/yr (0 to 0.62) for groups A and B, respectively. Polyethylene wear in group A was associated with linear osteolysis, and in group B with expansile osteolysis.

In patients with congenital hip disease, when 80% cover of the implant can be obtained, a cementless acetabular component appears to be acceptable and provides durable fixation. However, because of the type of osteolysis arising with these devices, early exchange of a worn liner is recommended before extensive bone loss makes revision surgery more complicated.


Y.-H. Kim J.-S. Kim

It has been suggested that the wear of ultra-high molecular weight polyethylene (UHMWPE) in total hip replacement is substantially reduced when the femoral head is ceramic rather than metal. However, studies of alumina and zirconia ceramic femoral heads on the penetration of an UHMWPE liner in vivo have given conflicting results.

The purpose of this study was to examine the surface characteristics of 30 alumina and 24 zirconia ceramic femoral heads and to identify any phase transformation in the zirconia heads. We also studied the penetration rate of alumina and zirconia heads into contemporary UHMWPE liners. The alumina heads had been implanted for a mean of 11.3 years (8.1 to 16.2) and zirconia heads for a mean of 9.8 years (7.5 to 15).

The mean surface roughness values of the explanted alumina heads (Ra 40.12 nm and Rpm 578.34 nm) were similar to those for the explanted zirconia heads (Ra 36.21 nm and Rpm 607.34 nm). The mean value of the monoclinic phase of two control zirconia heads was 1% (0.8% to 1.5%) and 1.2% (0.9% to 1.3%), respectively. The mean value of the monoclinic phase of 24 explanted zirconia heads was 7.3% (1% to 26%).

In the alumina group, the mean linear penetration rate of the UMWPE liner was 0.10 mm/yr (0.09 to 0.12) in hips with low Ra and Rpm values (13.22 nm and 85.91 nm, respectively). The mean linear penetration rate of the UHMWPE liner was 0.13 mm/yr (0.07 to 0.23) in hips with high Ra and Rpm values (198.72 nm and 1329 nm, respectively). This difference was significant (p = 0.041).

In the zirconia head group, the mean linear penetration rate of the UHMWPE liner was 0.09 mm/yr (0.07 to 0.14) in hips with low Ra and Rpm values (12.78 nm and 92.99 nm, respectively). The mean linear penetration rate of the UHMWPE liner was 0.12 mm/yr (0.08 to 0.22) in hips with high Ra and Rpm values (199.21 nm and 1381 nm, respectively). This difference was significant (p = 0.039).

The explanted zirconia heads which had a minimal phase transformation had similar surface roughness and a similar penetration rate of UHMWPE liner as the explanted alumina head.


H.-N. Pang N.-N. Lo K.-Y. Yang H.-C. Chong S.-J. Yeo

We have performed a prospective double-blind, randomised controlled trial over two years to evaluate the efficacy and safety of an intra-operative peri-articular injection of triamcinolone acetonide in patients undergoing medial unicondylar knee replacement. We randomised 90 patients into two equal groups. The study group received an injection of triamcinolone acetonide, bupivacaine, and epinephrine into the peri-articular tissues at the end of the operation. The control group received the same injection mixture but without the addition of triamcinolone. The peri-operative analgesic regimen was standardised.

The study group reported a significant reduction in pain (p = 0.014 at 12 hours, p = 0.031 at 18 hours and p = 0.031 at 24 hours) and had a better range of movement (p = 0.023 at three months). There was no significant difference in the rate of infection and no incidence of tendon rupture in either group.

The addition of corticosteroid to the peri-articular injection after unicondylar knee replacement had both immediate and short-term benefits in terms of relief from pain, and rehabilitation with no increased risk of infection.


N. L. Millar G. A. C. Murrell

We identified ten patients who underwent arthroscopic revision of anterior shoulder stabilisation between 1999 and 2005. Their results were compared with 15 patients, matched for age and gender, who had a primary arthroscopic stabilisation during the same period.

At a mean follow-up of 37 and 36 months, respectively, the scores for pain and shoulder function improved significantly between the pre-operative and follow-up visits in both groups (p = 0.002), with no significant difference between them (p = 0.4). The UCLA and Rowe shoulder scores improved significantly (p = 0.004 and p = 0.002, respectively), with no statistically significant differences between groups (p = 0.6). Kaplan-Meier analysis for time to recurrent instability showed no differences between the groups (p = 0.2).

These results suggest that arthroscopic revision anterior shoulder stabilisation is as reliable as primary arthroscopic stabilisation for patients who have had previous open surgery for recurrent anterior instability.


A. Terrier A. Reist F. Merlini A. Farron

Reversed shoulder prostheses are increasingly being used for the treatment of glenohumeral arthropathy associated with a deficient rotator cuff. These non-anatomical implants attempt to balance the joint forces by means of a semi-constrained articular surface and a medialised centre of rotation. A finite element model was used to compare a reversed prosthesis with an anatomical implant. Active abduction was simulated from 0° to 150° of elevation. With the anatomical prosthesis, the joint force almost reached the equivalence of body weight. The joint force was half this for the reversed prosthesis. The direction of force was much more vertically aligned for the reverse prosthesis, in the first 90° of abduction. With the reversed prosthesis, abduction was possible without rotator cuff muscles and required 20% less deltoid force to achieve it.

This force analysis confirms the potential mechanical advantage of reversed prostheses when rotator cuff muscles are deficient.


H. Resch P. Povacz H. Maurer H. Koller M. Tauber

After establishing anatomical feasibility, functional reconstruction to replace the anterolateral part of the deltoid was performed in 20 consecutive patients with irreversible deltoid paralysis using the sternoclavicular portion of the pectoralis major muscle. The indication for reconstruction was deltoid deficiency combined with massive rotator cuff tear in 11 patients, brachial plexus palsy in seven, and an isolated axillary nerve lesion in two. All patients were followed clinically and radiologically for a mean of 70 months (24 to 125). The mean gender-adjusted Constant score increased from 28% (15% to 54%) to 51% (19% to 83%). Forward elevation improved by a mean of 37°, abduction by 30° and external rotation by 9°.

The pectoralis inverse plasty may be used as a salvage procedure in irreversible deltoid deficiency, providing subjectively satisfying results. Active forward elevation and abduction can be significantly improved.


P. Raiss P. R. Aldinger P. Kasten M. Rickert M. Loew

Our aim in this prospective study was to evaluate the outcome of total shoulder replacement in the treatment of young and middle-aged active patients with primary glenohumeral osteoarthritis. We reviewed 21 patients (21 shoulders) with a mean age of 55 years (37 to 60). The mean follow-up was seven years (5 to 9). The same anatomical, third-generation, cemented implant had been used in all patients. All the patients were evaluated radiologically and clinically using the Constant and Murley score.

No patients required revision. In one a tear of the supraspinatus tendon occurred. Overall, 20 patients (95%) were either very satisfied (n = 18) or satisfied (n = 2) with the outcome. Significant differences (p < 0.0001) were found for all categories of the Constant and Murley score pre- and post-operatively. The mean Constant and Murley score increased from 24.1 points (10 to 45) to 64.5 points (39 to 93), and the relative score from 30.4% (11% to 50%) to 83% (54% to 116%). No clinical or radiological signs of loosening of the implant were seen.

For young and middle-aged patients with osteoarthritis, third-generation total shoulder replacement is a viable method of treatment with a low rate of complications and excellent results in the mid-term.


Trauma
Access Required
C. Edwards A. Counsell C. Boulton C. G. Moran

Prospective data on hip fracture from 3686 patients at a United Kingdom teaching hospital were analysed to investigate the risk factors, financial costs and outcomes associated with deep or superficial wound infections after hip fracture surgery.

In 1.2% (41) of patients a deep wound infection developed, and 1.1% (39) had a superficial wound infection. A total of 57 of 80 infections (71.3%) were due to Staphylococcus aureus and 39 (48.8%) were due to MRSA.

No statistically significant pre-operative risk factors were detected. Length of stay, cost of treatment and pre-discharge mortality all significantly increased with deep wound infection. The one-year mortality was 30%, and this increased to 50% in those who developed an infection (p < 0.001). A deep infection resulted in doubled operative costs, tripled investigation costs and quadrupled ward costs.

MRSA infection increased costs, length of stay, and pre-discharge mortality compared with non-MRSA infection.


S. E. Varitimidis G. K. Basdekis Z. H. Dailiana M. E. Hantes K. Bargiotas K. Malizos

In a randomised prospective study, 20 patients with intra-articular fractures of the distal radius underwent arthroscopically- and fluoroscopically-assisted reduction and external fixation plus percutaneous pinning. Another group of 20 patients with the same fracture characteristics underwent fluoroscopically-assisted reduction alone and external fixation plus percutaneous pinning. The patients were evaluated clinically and radiologically at follow-up of 24 months. The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and modified Mayo wrist score were used at 3, 9, 12 and 24 months postoperatively. In the arthroscopically- and fluoroscopically-assisted group, triangular fibrocartilage complex tears were found in 12 patients (60%), complete or incomplete scapholunate ligament tears in nine (45%), and lunotriquetral ligament tears in four (20%). They were treated either arthroscopically or by open operation. Patients who underwent arthroscopically- and fluoroscopically-assisted treatment had significantly better supination, extension and flexion at all time points than those who had fluoroscopically-assisted surgery. The mean DASH scores were similar for both groups at 24 months, whereas the difference in the mean modified Mayo wrist scores remained statistically significant.

Although the groups are small, it is clear that the addition of arthroscopy to the fluoroscopically-assisted treatment of intra-articular distal radius fractures improves the outcome. Better treatment of associated intra-articular injuries might also have been a reason for the improved outcome.


Oncology
Access Required
L. H. Aksnes H. C. F. Bauer N. L. Jebsen G. Foller̊s C. Allert G. S. Haugen K. S. Hall

We evaluated the long-term functional outcome in 118 patients treated for osteosarcoma or Ewing’s sarcoma in the extremities a minimum of five years after treatment. We also examined if impaired function influenced their quality of life and ability to work.

The function was evaluated according to the Musculoskeletal Tumor Society (MSTS) score and the Toronto Extremity Salvage Score (TESS). Quality of life was assessed by using the Short Form-36 (SF-36).

The mean age at follow-up was 31 years (15 to 57) and the mean follow-up was for 13 years (6 to 22). A total of 67 patients (57%) initially had limb-sparing surgery, but four had a secondary amputation. The median MSTS score was 70% (17% to 100%) and the median TESS was 89% (43% to 100%). The amputees had a significantly lower MSTS score than those with limb-sparing surgery (p < 0.001), but there was no difference for the TESS. Tumour localisation above knee level resulted in significantly lower MSTS scores and TESS (p = 0.003 and p = 0.02, respectively).

There were no significant differences in quality of life between amputees and those with limb-sparing surgery except in physical functioning. Of the patients 11% (13) did not work or study. In multivariate analysis, amputation, tumour location above the knee and having muscular pain were associated with low physical function.

We conclude that most of the bone tumour survivors managed well after adjustment to their physical limitations. A total of 105 are able to work and have an overall good quality of life.


T. Liu X. Zhang Z. Li W. Zeng D. Peng C. Sun

Nonunion of the humerus with bone loss and shortening due to osteomyelitis is rare but difficult to treat. We describe our experience with a callus distraction technique using a monolateral external fixator for the treatment of this condition.

Between October 1994 and January 2004, 11 patients were treated. There were seven males and four females, with a mean age of 14 years (10 to 17). The mean bone loss was 1.9 cm (1 to 2.7) and the mean length discrepancy in the upper limb was 5.6 cm (3.5 to 8.0).

The mean follow-up was for 106 months (54 to 166). The mean external fixation index was 34.8 days/cm (29.8 to 40.5). The mean lengthening was 9.5 cm (5.5 to 13.4). There were seven excellent results, three good and one poor. There were nine excellent functional results and two good.

The treatment of humeral nonunion with bone loss and shortening due to osteomyelitis by callus distraction is a safe and effective means of improving function and cosmesis.


O. Lahoti S. Bajaj

Most cases of club foot (congenital talipes equinovarus) respond to non-operative treatment but resistant cases may need surgery. It is broadly accepted that lengthening of tendo Achillis, the tendon of tibialis posterior and capsulotomy of the ankle and subtalar joints are necessary during surgical release, but there is no consensus as to whether lengthening of the tendons of flexor hallucis longus and flexor digitorum longus is required.

We randomised 13 children with severe bilateral club foot deformities to undergo lengthening of the flexor hallucis longus and flexor digitorum longus tendons on one side and simple decompression on the other. We found no difference in the deformities of the toes between the lengthened and non-lengthened sides at a mean follow-up of four years (2 to 6).

We conclude that routine lengthening of the tendons of flexor hallucis longus and flexor digitorum longus during soft-tissue surgery for resistant club foot is not necessary.


Schwannoma of the fibula Pages 803 - 805
Access Required
T. Palocaren N. M. Walter V. Madhuri S. Gibikote

We describe a schwannoma located in the mid-diaphyseal region of the fibula of a 14-year-old boy. Radiologically this was an expansile, lytic, globular and trabeculated lesion. MRI showed a narrow transition zone with a break in the cortex and adjacent tissue oedema. Differential diagnosis included schwannoma, fibrous dysplasia, giant cell tumour and aneurysmal bone cyst. The tumour was excised en bloc, with marginal resection limits, and there has been no recurrence two years after surgery. Histopathological examination confirmed the diagnosis of classic schwannoma. There were typical hypercellular Antoni A zones, less cellular Antoni B zones, and diffuse immunoreactivity to S100 protein. This is the first report of schwannoma involving a long bone in a child.


K. J. Burkhart P. M. Rommens

We describe a patient with insufficient bone regeneration of the tibia after bone transport over an intramedullary nail, in whom union was ultimately achieved after exchange nailing and intramedullary application of rh-bone morphogenetic protein-7 at the site of distraction.


R. Klein R. Burgkart K. Woertler R. Gradinger S. Vogt

Osteochondrosis juvenilis is caused by a dysfunction of endochondral ossification. Several epiphyses and apophyses can be affected, but osteochondrosis juvenilis of the medial malleolus has not been reported. We describe a 12-year-old boy with bilateral pes planovalgus who was affected by this condition. Conservative management was successful. The presentation, aetiology and treatment are described and the importance of including it in the differential diagnosis is discussed.


Research
Access Required
C. R. Chu N. J. Izzo C. H. Coyle N. E. Papas A. Logar

We have studied the effects of bupivacaine on human and bovine articular chondrocytes in vitro. Time-lapse confocal microscopy of human articular chondrocytes showed > 95% cellular death after exposure to 0.5% bupivacaine for 30 minutes. Human and bovine chondrocytes exposed to 0.25% bupivacaine had a time-dependent reduction in viability, with longer exposure times resulting in higher cytotoxicity. Cellular death continued even after removal of 0.25% bupivacaine. After exposure to 0.25% bupivacaine for 15 minutes, flow cytometry showed bovine chondrocyte viability to be 41% of saline control after seven days. After exposure to 0.125% bupivacaine for up to 60 minutes, the viability of both bovine and human chondrocytes was similar to that of control groups.

These data show that prolonged exposure 0.5% and 0.25% bupivacaine solutions are potentially chondrotoxic.


T. N. Board P. Rooney P. R. Kay

In order to investigate the osteoinductive properties of allograft used in impaction grafting and the effect of strain during impaction on these properties, we designed an in vitro experiment to measure strain-related release of bone morphogenetic protein-7 (BMP-7) from fresh-frozen femoral head allograft. A total of 40 10 mm cubes of cancellous bone were cut from ten samples of fresh-frozen femoral head. The marrow was removed from the cubes and the baseline concentrations of BMP-7 were measured. Specimens from each femoral head were allocated to four groups and subjected to different compressive strains with a material testing machine, after which BMP-7 activity was reassessed. It was present in all groups. There was a linear increase of 102.1 pg/g (95% confidence interval 68.6 to 135.6) BMP-7 for each 10% increase in strain. At 80% strain the mean concentration of BMP-7 released (830.3 pg/g bone) was approximately four times that released at 20% strain. Activity of BMP-7 in fresh-frozen allograft has not previously been demonstrated. This study shows that the freezing and storage of femoral heads allows some maintenance of biological activity, and that impaction grafting provides a source of osteoinductive bone for remodelling.

We have shown that BMP-7 is released from fresh-frozen femoral head cancellous bone in proportion to the strain applied to the bone. This suggests that the impaction process itself may contribute to the biological process of remodelling and bony incorporation.