header advert
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Volume 88-B, Issue 12 December 2006

Review Article
Access Required
I. D. McDermott A. A. Amis

The menisci of the knee have an important role in load-bearing and shock absorption within the joint. They may also function as secondary stabilisers, have a proprioceptive role, and aid the lubrication and nutrition of the articular cartilage. Complete or partial loss of a meniscus can have damaging effects on a knee, leading to serious long-term sequelae.

This paper reviews the consequences of meniscectomy and summarises the body of evidence in the literature regarding those factors most relevant to long-term outcome.


Access Required
V. Khanduja R. N. Villar

This review describes the development of arthroscopy of the hip over the past 15 years with reference to patient assessment and selection, the technique, the conditions for which it is likely to prove useful, the contraindications and complications related to the procedure and, finally, to discuss possible developments in the future.


S. Kovac R. Trebse I. Milosev V. Pavlovcic V. Pisot

We present a retrospective series of 170 cemented titanium straight-stem femoral components combined with two types of femoral head: cobalt-chromium (CoCr) alloy (114 heads) and alumina ceramic (50 heads). Of the study group, 55 patients (55 stems) had died and six (six stems) were lost to follow-up. At a mean of 13.1 years (3 to 15.3) 26 stems had been revised for aseptic loosening. The mean follow-up time for stable stems was 15.1 years (12.1 to 16.6).

Survival of the stem at 15 years was 75.4% (95% confidence interval (CI) 67.3 to 83.5) with aseptic failure (including radiological failure) as the end-point, irrespective of the nature of the head and the quality of the cement mantle. Survival of the stem at 15 years was 79.1% (95% CI 69.8 to 88.4) and 67.1% (95% CI 51.3 to 82.9) with the CoCr alloy and ceramic heads, respectively. The quality of the cement mantle was graded as a function of stem coverage: stems with complete tip coverage (type 1) had an 84.9% (95% CI 77.6 to 92.2) survival at 15 years, compared with those with a poor tip coverage (type 2) which had a survival of only 22.4% (95% CI 2.4 to 42.4). The poor quality of the cement mantle and the implantation of an alumina head substantially lowered the survival of the stem.

In our opinion, further use of the cemented titanium alloy straight-stem femoral components used in our series is undesirable.


H. K. Pihlajamäki J.-P. Ruohola M. Weckström M. J. Kiuru T. I. Visuri

The incidence and long-term outcome of undisplaced fatigue fractures of the femoral neck treated conservatively were examined in Finnish military conscripts between 1970 and 1990.

From 106 cases identified, 66 patients with 70 fractures were followed for a mean of 18.3 years (11 to 32). The original medical records and radiographs were studied and physical and radiological follow-up data analysed for evidence of risk factors for this injury. The development of avascular necrosis and osteoarthritis was determined from the follow-up radiographs and MR scans.

The impact of new military instructions on the management of hip-related pain was assessed following their introduction in 1986. The preventive regimen (1986) improved awareness and increased the detected incidence from 13.2 per 100 000 service-years (1970 to 1986) to 53.2 per 100 000 (1987 to 1990). No patient developed displacement of the fracture or avascular necrosis of the femoral head, or suffered from adverse complications. No differences were found in MRI-measured hip joint spaces at final follow-up. The mean Harris Hip Score was 97 (70 to 100) and the Visual Analogue Scale 5.85 mm (0 to 44).

Non-operative treatment, including avoidance of or reduced weight-bearing, gave favourable short- and long-term outcomes. Undisplaced fatigue fractures of the femoral neck neither predispose to avascular necrosis nor the subsequent development of osteoarthritis of the hip.


Z. X. Ling V. P. Kumar

We investigated the relationship of the inferior gluteal nerve to gluteus maximus by dissecting the muscle in 12 fresh-frozen and formalin-treated cadavers. The anatomy was recorded using still digital photography. The course of the inferior gluteal nerve was carefully traced and was noted to enter the deep surface of gluteus maximus approximately 5 cm from the tip of the greater trochanter of the femur. The susceptibility of the nerve to injury during a posterior approach to the hip may be explained by its close relationship to the deep surface of gluteus maximus. It is easily damaged before it has been seen if the muscle is split and parted more than 5 cm from the tip of the greater trochanter of the femur. We suggest that a modified posterior approach be used to expose the hip to avoid damage to this nerve.


The Exeter Universal stem Pages 1584 - 1590
Access Required
S. Hook E. Moulder P. J. Yates B. J. Burston E. Whitley G. C. Bannister

We reviewed 142 consecutive primary total hip replacements implanted into 123 patients between 1988 and 1993 using the Exeter Universal femoral stem. A total of 74 patients (88 hips) had survived for ten years or more and were reviewed at a mean of 12.7 years (10 to 17). There was no loss to follow-up.

The rate of revision of the femoral component for aseptic loosening and osteolysis was 1.1% (1 stem), that for revision for any cause was 2.2% (2 stems), and for re-operation for any cause was 21.6% (19 hips). Re-operation was because of failure of the acetabular component in all but two hips.

All but one femoral component subsided within the cement mantle to a mean of 1.52 mm (0 to 8.3) at the final follow-up. One further stem had subsided excessively (8 mm) and had lucent lines at the cement-stem and cement-bone interfaces. This was classified as a radiological failure and is awaiting revision. One stem was revised for deep infection and one for excessive peri-articular osteolysis. Defects of the cement mantle (Barrack grade C and D) were found in 28% of stems (25 hips), associated with increased subsidence (p = 0.01), but were not associated with endosteal lysis or failure.

Peri-articular osteolysis was significantly related to the degree of polyethylene wear (p < 0.001), which was in turn associated with a younger age (p = 0.01) and male gender (p < 0.001).

The use of the Exeter metal-backed acetabular component was a notable failure with 12 of 32 hips (37.5%) revised for loosening. The Harris-Galante components failed with excessive wear, osteolysis and dislocation with 15% revised (5 of 33 hips). Only one of 23 hips with a cemented Elite component (4%) was revised for loosening and osteolysis.

Our findings show that the Exeter Universal stem implanted outside the originating centre has excellent medium-term results.


A. J. Price P. T. Oppold D. W. Murray A. B. Zavatsky

The Oxford medial unicompartmental knee replacement was designed to reproduce normal mobility and forces in the knee, but its detailed effect on the patellofemoral joint has not been studied previously. We have examined the effect on patellofemoral mechanics of the knee by simultaneously measuring patellofemoral kinematics and forces in 11 cadaver knee specimens in a supine leg-extension rig. Comparison was made between the intact normal knee and sequential unicompartmental and total knee replacement. Following medial mobile-bearing unicompartmental replacement in 11 knees, patellofemoral kinematics and forces did not change significantly from those in the intact knee across any measured parameter. In contrast, following posterior cruciate ligament retaining total knee replacement in eight knees, there were significant changes in patellofemoral movement and forces.

The Oxford device appears to produce near-normal patellofemoral mechanics, which may partly explain the low incidence of complications with the extensor mechanism associated with clinical use.


S. D. Muller D. J. Deehan J. P. Holland S. E. Outterside L. M. G. Kirk P. J. Gregg A. W. McCaskie

The role of modular tibial implants in total knee replacement is not fully defined. We performed a prospective randomised controlled clinical trial using radiostereophotogrammetric analysis to compare the performance of an all-polyethylene tibia with a metal-backed cruciate-retaining condylar design, PFC-∑ total knee replacement for up to 24 months. There were 51 patients who were randomised into two treatment groups. There were 10 subsequent withdrawals, leaving 21 all-polyethylene and 20 metal-backed tibial implants. No patient was lost to follow-up. There were no significant demographic differences between the groups. At two years one metal-backed implant showed migration > 1 mm, but no polyethylene implant reached this level. There was a significant increase in the SF-12 and Oxford knee scores after operation in both groups.

In an uncomplicated primary total knee replacement the all-polyethylene PFC-∑ tibial prosthesis showed no statistical difference in migration from that of the metal-backed counterpart. There was no difference in the clinical results as assessed by the SF-12, the Oxford knee score, alignment or range of movement at 24 months, although these assessment measures were not statistically powered in this study.


F. Middleton J. Coakes S. Umarji S. Palmer R. Venn S. Panayiotou

The intra-articular injection of local anaesthetic is frequently used for pain relief after arthroscopy. There is, however, no published evidence of the analgesic effect of bupivacaine in the ankle. In a randomised, double-blind study, 35 patients undergoing arthroscopy of the ankle were allocated to receive intra-articular saline or bupivacaine. Pain was assessed using pain scores and additional analgesic requirements. Intra-articular bupivacaine had a significant analgesic effect in the immediate post-operative period, reducing pain scores and the need for additional analgesics.

We recommend the use of intra-articular bupivacaine for post-operative analgesia in ankle surgery.


M. Seki H. Nakamura H. Kono

We studied 21 patients with a spontaneous palsy of the anterior interosseous nerve. There were 11 men and 10 women with a mean age at onset of 39 years (17 to 65).

Pain around the elbow or another region (forearm, shoulder, upper arm, systemic arthralgia) was present in 17 patients and typically lasted for two to three weeks. It had settled within six weeks in every case. In ten cases the palsy developed as the pain settled. A complete palsy of flexor pollicis longus and flexor digitorum profundus to the index finger was seen in 13 cases and an isolated palsy of flexor pollicis longus in five. All patients were treated without operation. The mean time to initial muscle contraction was nine months (2 to 18) in palsy of the flexor digitorum profundus to the index finger, and ten months (1 to 24) for a complete palsy of flexor pollicis longus. An improvement in muscle strength to British Medical Research Council grade 4 or better was seen in all 15 patients with a complete palsy of the flexor digitorum profundus and in 16 of 18 with a complete palsy of flexor pollicis longus.

There was no significant correlation between the duration of pain and either the time to initial muscle contraction or final muscle strength. Prolonged pain was not always associated with a poor outcome but the age of the patient when the palsy developed was strongly correlated. Recovery occurred within 12 months in patients under the age of 40 years who achieved a final British Medical Research Council grade of 4 or better. Surgical decompression does not appear to be indicated for young patients with this condition.


M. Al-Rashid K. Theivendran M. A. C. Craigen

The use of volar locking compression plates for the treatment of fractures of the distal radius is becoming increasingly popular because of the stable biomechanical construct, less soft-tissue disturbance and early mobilisation of the wrist. A few studies have reported complications such as rupture of flexor tendons. We describe three cases of rupture of extensor tendons after the use of volar locking compression plates. We recommend extreme care when drilling and placing the distal radial screws to prevent damaging the extensor tendons.


M. A. Karunakar A. Sen M. J. Bosse S. H. Sims J. A. Goulet J. F. Kellam

Our study was designed to compare the effect of indometacin with that of a placebo in reducing the incidence of heterotopic ossification in a prospective, randomised trial. A total of 121 patients with displaced fractures of the acetabulum treated by operation through a Kocher-Langenbeck approach was randomised to receive either indometacin (75 mg) sustained release, or a placebo once daily for six weeks. The extent of heterotopic ossification was evaluated on plain radiographs three months after operation. Significant ossification of Brooker grade III to IV occurred in nine of 59 patients (15.2%) in the indometacin group and 12 of 62 (19.4%) receiving the placebo.

We were unable to demonstrate a statistically significant reduction in the incidence of severe heterotopic ossification with the use of indometacin when compared with a placebo (p = 0.722). Based on these results we cannot recommend the routine use of indometacin for prophylaxis against heterotopic ossification after isolated fractures of the acetabulum.


M. Bhandari J. Matta T. Ferguson G. Matthys

We aimed to identify variables associated with clinical and radiological outcome following fractures of the acetabulum associated with posterior dislocation of the hip. Using a prospective database of 1076 such fractures, we identified 109 patients with this combined injury managed operatively within three weeks and followed up for two or more years. The patients had a mean age of 42 years (15 to 79), 78 (72%) were male, and 84 (77%) had been involved in motor vehicle accidents. Using multivariate analysis the quality of reduction of the fracture was identified as the only significant predictor of radiological grade, clinical function and the development of post-traumatic arthritis (p < 0.001). All patients lacking anatomical reduction developed arthritis whereas only 25.5% (24 patients) with an anatomical reduction did so (p = 0.05).

The quality of the reduction of the fracture is the most important variable in forecasting the outcome for patients with this injury. The interval to reduction of the dislocation of the hip may be less important than previously described.


B. Livani W. D. Belangero R. Castro de Medeiros

Fractures of the distal third of the humerus may be complicated by complete lesions of the radial nerve which may be entrapped or compressed by bone fragments. Indirect reduction and internal fixation may result in a permanent nerve lesion.

We describe the treatment of these lesions by insertion of a bridge plate using the minimally-invasive percutaneous technique. Six patients were operated on and showed complete functional recovery. Healing of the fractures occurred at a mean of 2.7 months (2 to 3) and complete neurological recovery by a mean of 2.3 months (1 to 5). In one patient infection occurred which resolved after removal of the implant.


Access Required
P. Jungbluth T. M. Frangen S. Arens G. Muhr T. Kälicke

The Essex-Lopresti injury is rare. It consists of fracture of the head of the radius, rupture of the interosseous membrane and disruption of the distal radioulnar joint. The injury is often missed because attention is directed towards the fracture of the head of the radius. We present a series of 12 patients with a mean age of 44.9 years (26 to 54), 11 of whom were treated surgically at a mean of 4.6 months (1 to 16) after injury and the other after 18 years. They were followed up for a mean of 29.2 months (2 to 69). Ten patients had additional injuries to the forearm or wrist, which made diagnosis more difficult. Replacement of the head of the radius was carried out in ten patients and the Sauve-Kapandji procedure in three. Patients were assessed using standard outcome scores. The mean post-operative Disabilities of the Arm, Shoulder and Hand score was 55 (37 to 83), the mean Morrey Elbow Performance score was 72.2 (39 to 92) and the mean Mayo wrist score was 61.3 (35 to 80). The mean grip strength was 68.5% (39.6% to 91.3%) of the unaffected wrist.

Most of the patients (10 of 12) were satisfied with their operation and in 11 the pain was relieved. When treating the chronic Essex-Lopresti injury, we recommend accurate realignment of the radius and ulna and replacement of the head of the radius. If this fails a Sauve-Kapandji procedure to arthrodese the distal radioulnar joint should be undertaken to stabilise the forearm while maintaining mobility.


J. Stulik J. Stehlik M. Rysavy A. Wozniak

We describe the results of 287 intra-articular fractures of the calcaneum in 247 patients treated by minimally-invasive reduction and K-wire fixation between 1994 and 2003. There were 210 men (85%) and 37 women (15%). The most common cause of injury was a fall from a height in 237 patients (96%). Fracture classification was based on the method described by Sanders and Essex-Lopresti. All patients were operated on within 21 days of injury and 89% (220) within 48 hours. The reduction was graded as nearly anatomical (less than 2 mm residual articular displacement and satisfactory overall alignment) in 212 (73.9%) fractures.

There were 20 cases (7%) of superficial pin-track infection and five (1.7%) of deep infection. All healed at a mean of 6 weeks (3 to 19). Loss of reduction was observed in 13 fractures (4.5%) and a musculocutaneous flap was needed in three (1%).

The results were evaluated in 176 patients (205 fractures) with a mean age of 44.3 years (13 to 67), available for follow-up at a mean of 43.4 months (25 to 87) using the Creighton-Nebraska Health Foundation Assessment score. The mean score was 83.9 points (63 to 100). There were 29 (16.5%) excellent, 98 (55.7%) good, 26 (14.8%) fair and 23 (13%) poor results. A total of 130 patients (73.9%) were able to return to their original occupation at a mean of 5.6 months (3.2 to 12.5) after the injury.

Semi-open reduction and percutaneous fixation is an effective treatment for displaced intra-articular fractures of the calcaneum.


S. Shalaby H. Shalaby A. Bassiony

We report the results of limb salvage for non-metastatic osteosarcoma of the distal tibia using resection arthrodesis, autogenous fibular graft and fixation by an Ilizarov external fixator.

In six patients with primary osteosarcoma of the distal tibia who refused amputation, treatment with wide en bloc resection and tibiotalar arthrodesis was undertaken. The defect was reconstructed using non-vascularised free autogenous fibular strut graft in three patients and a vascularised pedicular fibular graft in three, all supplemented with iliac cancellous graft at the graft-host junction. An Ilizarov external fixator was used for stabilisation of the reconstruction.

In five patients sound fusion occurred at a mean of 13.2 months (8 to 20) with no evidence of local recurrence or deep infection at final follow-up. The mean post-operative functional score was 70% (63% to 73%) according to the Musculoskeletal Tumour Society scoring system. All five patients showed graft hypertrophy.

Union of the graft was faster in cases reconstructed by vascularised fibular grafts. One patient who had a poor response to pre-operative chemotherapy developed local tumour recurrence at one year post-operatively and required subsequent amputation.


J. Issakov V. Soyfer Y. Kollender J. Bickels I. Meller O. Merimsky

Between December 1995 and March 2003, 38 adult patients with intermediate or high-grade liposarcoma in a limb were treated by limb-sparing surgery and post-operative radiotherapy. The ten-year local recurrence-free survival was 83%, the ten-year metastasis-free survival 61%, the ten-year disease-free survival 51% and the ten-year overall survival 67%. Analysis of failure and success showed no association with the age of the patients, gender, the location of the primary tumour, the type of liposarcoma and the quality of resection.

Our results indicate that liposarcoma may recur even ten years after the end of definitive therapy and may spread to unexpected sites as for soft-tissue sarcoma.


N. K. Bowman T. A. Bucher A. A. Bassily

Resurfacing arthroplasties of the hip are being undertaken with increasing frequency and the complications associated with this procedure are well documented. We have encountered a further problem with a fracture of the centralising peg of the femoral component in a prosthesis which had been in situ for three years.


R. Kingma J. M. Peters L. N. J. E. M. Coene

A 71-year-old man with ankylosing spondylitis and an unstable fracture of the 6th and 7th cervical vertebrae was managed with a halo vest. Eight weeks following application the halo had shifted because of a loose pin. The patient’s only complaint at the time was a headache but this was followed two days later by a seizure. An MR scan of the brain showed a swollen cortex under the right dorsal pin as a result of a perforation of the internal lamina by the pin. The halo was removed and anti-epileptic medication commenced. The patient had no further seizures.


H. Hatano T. Morita H. Kobayashi H. Otsuka

Despite extensive experience with prosthetic replacement for the reconstruction of limbs following juxta-articular resection of tumours, there are few reports of prosthetic replacement of the distal radius. We present two cases of massive bone defects of the distal radius in which alumina ceramic prosthetic replacements were used. We evaluated the patients more than ten years after the procedure. Both patients had degenerative changes to the wrist. This, however, was not associated with pain or decreased function, and both had returned to their previous occupation after surgery.

When a patient has a massive defect of the distal radius, reconstruction using a ceramic prosthesis is a reasonable alternative to using autograft. This method of treatment results in little pain, a moderate range of movement and satisfactory function.


S. Surendran S. H. Kim B. K. Jee S. H. Ahn P. Gopinathan C. W. Han

We stably transfected early passage chondrocytes with an anti-apoptotic Bcl-2 gene in vitro using a retrovirus vector. Samples of articular cartilage were obtained from 11 patients with a mean age of 69 years (61 to 75) who were undergoing total knee replacement for osteoarthritis. The Bcl-2-gene-transfected chondrocytes were compared with non-transfected and lac-Z-gene-transfected chondrocytes, both of which were used as controls. All three groups of cultured chondrocytes were incubated with nitric oxide (NO) for ten days. Using the Trypan Blue exclusion assay, an enzyme-linked immunosorbent assay and flow cytometric analysis, we found that the number of apoptotic chondrocytes was significantly higher in the non-transfected and lac-Z-transfected groups than in the Bcl-2-transfected group (p < 0.05). The Bcl-2-transfected chondrocytes were protected from NO-induced impairment of proteoglycan synthesis.

We conclude that NO-induced chondrocyte death involves a mechanism which appears to be subject to regulation by an anti-apoptotic Bcl-2 gene. Therefore, Bcl-2 gene therapy may prove to be of therapeutic value in protecting human articular chondrocytes.


T. Shisha S. Kiss K. Pap H. Simpson G. Szöke

The response of the muscle is critical in determining the functional outcome of limb lengthening. We hypothesised that muscle response would vary with age and therefore studied the response of the muscles during tibial lengthening in ten young and ten mature rabbits. A bromodeoxyuridine technique was used to identify the dividing cells.

The young rabbits demonstrated a significantly greater proliferative response to the distraction stimulus than the mature ones. This was particularly pronounced at the myotendinous junction, but was also evident within the muscle belly.

Younger muscle adapted better to lengthening, suggesting that in patients in whom a large degree of muscle lengthening is required it may be beneficial to carry out this procedure when they are young, in order to achieve the optimal functional result.


B. A. Rogers C. L. Murphy S. R. Cannon T. W. R. Briggs

The weight-bearing status of articular cartilage has been shown to affect its biochemical composition. We have investigated the topographical variation of sulphated glycosaminoglycan (GAG) relative to the DNA content of the chondrocyte in human distal femoral articular cartilage.

Paired specimens of distal femoral articular cartilage, from weight-bearing and non-weight-bearing regions, were obtained from 13 patients undergoing above-knee amputation. After papain enzyme digestion, spectrophotometric GAG and fluorometric DNA assays assessed the biochemical composition of the samples. The results were analysed using a paired t-test.

Although there were no significant differences in cell density between the regions, the weight-bearing areas showed a significantly higher concentration of GAG relative to DNA when compared with non-weight-bearing areas (p = 0.02).

We conclude that chondrocytes are sensitive to their mechanical environment, and that local loading conditions influence the metabolism of the cells and hence the biochemical structure of the tissue.


Obituary
Access Required

Access Required
B. DERBYSHIRE M. L. PORTER

Author’s reply Pages 1676 - 1677
Access Required
D. W. MURRAY H. S. GILL

Author’s reply Pages 1677 - 1677
Access Required
D. W. MURRAY H. S. GILL

Access Required

Access Required

Access Required