Volume 87-B, Issue 6 June 2005

P. V. Giannoudis J. Parker M. H. Wilcox

Access Required
R. Nizard L. Sedel D. Hannouche M. Hamadouche P. Bizot

Annotation
Access Required
J. Calder S. Mannion

R. Biedermann A. Tonin M. Krismer F. Rachbauer G. Eibl B. Stöckl

Malposition of the acetabular component is a risk factor for post-operative dislocation after total hip replacement (THR). We have investigated the influence of the orientation of the acetabular component on the probability of dislocation. Radiological anteversion and abduction of the component of 127 hips which dislocated post-operatively were measured by Einzel-Bild-Röentgen-Analysis and compared with those in a control group of 342 patients.

In the control group, the mean value of anteversion was 15° and of abduction 44°. Patients with anterior dislocation after primary THR showed significant differences in the mean angle of anteversion (17°), and abduction (48°) as did patients with posterior dislocation (anteversion 11°, abduction 42°). After revision patients with posterior dislocation showed significant differences in anteversion (12°) and abduction (40°).

Our results demonstrate the importance of accurate positioning of the acetabular component in order to reduce the frequency of subsequent dislocations. Radiological anteversion of 15° and abduction of 45° are the lowest at-risk values for dislocation.


P.-H. Hsieh C.-H. Shih Y.-H. Chang M. S. Lee W.-E. Yang H.-N. Shih

We have carried out in 24 patients, a two-stage revision arthroplasty of the hip for infection with massive bone loss. We used a custom-made, antibiotic-loaded cement prosthesis as an interim spacer. Fifteen patients had acetabular deficiencies, eight had segmental femoral bone loss and one had a combined defect.

There was no recurrence of infection at a mean follow-up of 4.2 years (2 to 7). A total of 21 patients remained mobile in the interim period. The mean Merle D’Aubigné and Postel hip score improved from 7.3 points before operation to 13.2 between stages and to 15.8 at the final follow-up. The allograft appeared to have incorporated into the host bone in all patients. Complications included two fractures and one dislocation of the cement prosthesis.

The use of a temporary spacer maintains the function of the joint between stages even when there is extensive loss of bone. Allograft used in revision surgery after septic conditions restores bone stock without the risk of recurrent infection.


Y.-G. Kim S.-Y. Kim S.-J. Kim B.-C. Park P.-T. Kim J.-C. Ihn

We performed 114 consecutive primary total hip arthroplasties with a cementless expansion acetabular component in 101 patients for advanced osteonecrosis of the femoral head. The mean age of the patients at surgery was 51 years (36 to 62) and the mean length of follow-up was 110 months (84 to 129).

The mean pre-operative Harris hip score of 47 points improved to 93 points at final follow-up. The polyethylene liner was exchanged in two hips during this period and one broken acetabular component was revised. The mean linear wear rate of polyethylene was 0.07 mm/year and peri-acetabular osteolysis was seen in two hips (1.9%). Kaplan-Meier analysis indicated that the survival of the acetabular component without revision was 97.8% (95% confidence interval 0.956 to 1.000) at ten years.

Our study has shown that the results of THA with a cementless expansion acetabular component and an alumina-polyethylene bearing surface are good.


O. P. P. Temmerman P. G. H. M. Raijmakers J. Berkhof O. S. Hoekstra G. J. J. Teule I. C. Heyligers

In this meta-analysis we included 32 English-language articles published between January 1975 and June 2004 on the diagnostic performance of plain radiography, subtraction arthrography, nuclear arthrography and bone scintigraphy in detecting aseptic loosening of the femoral component, using criteria based on the Cochrane systematic review of screening and diagnostic tests.

The mean sensitivity and specificity were, respectively, 82% (95% confidence interval (CI) 76 to 87) and 81% (95% CI 73 to 87) for plain radiography and 85% (95% CI 75 to 91) and 83% (95% CI 75 to 89) for nuclear arthrography. Pooled sensitivity and specificity were, respectively, 86% (95% CI 74 to 93) and 85% (95% CI 77 to 91) for subtraction arthrography and 85% (95% CI 79 to 89) and 72% (95% CI 64 to 79) for bone scintigraphy. Although the diagnostic performance of the imaging techniques was not significantly different, plain radiography and bone scintigraphy are preferred for the assessment of a femoral component because of their efficacy and lower risk of patient morbidity.


G. P. Grobler I. D. Learmonth B. P. Bernstein B. J. Dower

We retrospectively reviewed, ten years after surgery, 100 consecutive total hip replacements in which the Duraloc 300 cup had been used. Post-operative radiographs were analysed for placement of the cup and interface gaps and follow-up radiographs for lucent lines, osteolysis, wear and migration.

All the components were found to be stable with no evidence of loosening. The mean rate of wear was 0.12 mm/year. Three hips developed acetabular osteolysis at the level of the apex hole. Two have successfully undergone bone grafting without removal of the implants and one patient is awaiting surgery. The Duraloc 300 cup has a survival of 100% at ten years with no aseptic loosening and a low incidence of pelvic osteolysis.


A. Eren H. Ömeroglu M. Güven E. Ugutmen F. Altintas

We treated 26 hips (24 consecutive patients) with residual dysplasia by a technique of incomplete triple pelvic osteotomy. The mean age of the patients was 21.6 years.

The mean values for the pre-operative centre-edge angle of Wiberg, the refined centre-edge angle, the acetabular angle of Sharp, the modified acetabular angle and femoral head lateralisation were 7.7°, −3.1°, 49.3°, 53.2° and 17.2 mm, respectively. After a mean follow-up of 3.3 years they were 27.0°, 13.0°, 38.9°, 44.3° and 15.9 mm, respectively (p < 0.05). The osteoarthritic grading changed adversely in one hip. The mean pre-operative and latest Harris hip scores were 74.9 and 93.0, respectively (p < 0.05).

This technique provides a stable osteotomy with maintenance of the posterior column which allows early mobilisation and minimal internal fixation. The technique is not complex and requires minimal blood transfusion. The use of an image intensifier is not necessary and harvesting of a subcristal bone graft avoids post-operative complications at the donor site.


A. Lakdawala S. Todo G. Scott

We investigated the changes in surface roughness of retrieved femoral components in 18 men and four women at revision knee surgery. The mean age at revision was 68.4 years and the mean period of implantation was for 55.6 months. Eighteen implants were retrieved for aseptic loosening and four for infection. The surface changes in the articulating areas were inspected visually and the roughness (Ra) analysed with a profilometer. Parallel scratching and burnishing were the two main forms of damage. The mean Ra measurements in the articulating areas showed no statistically significant difference when compared with those in a control area on either side of the patellar groove at the apex of the femoral flange. This suggests that it is not essential to revise a well-fixed and correctly aligned femoral component where the polished surface has become burnished or bears fine parallel scratches, if the revision is conducted solely for failure of the tibial component.


R. Ramesh O. Von Arx T. Azzopardi P. J. Schranz

We assessed hyperextension of the knee and joint laxity in 169 consecutive patients who underwent an anterior cruciate ligament reconstruction between 2000 and 2002 and correlated this with a selected number of age- and gender-matched controls. In addition, the mechanism of injury in the majority of patients was documented. Joint laxity was present in 42.6% (72 of 169) of the patients and hyperextension of the knee in 78.7% (133 of 169). All patients with joint laxity had hyperextension of their knee. In the control group only 21.5% (14 of 65) had joint laxity and 37% (24 of 65) had hyperextension of the knee. Statistical analysis showed a significant correlation for these associations. We conclude that anterior cruciate ligament injury is more common in those with joint laxity and particularly so for those with hyperextension of the knee.


Y. Matsuda Y. Ishii H. Noguchi R. Ishii

We performed a randomised, prospective study of 80 mobile-bearing total knee arthroplasties (80 knees) in order to measure the effects of varus-valgus laxity and balance on the range of movement (ROM) one year after operation. Forty knees had a posterior-cruciate-ligament (PCL)-retaining prosthesis and the other 40 a PCL-sacrificing prosthesis. In the balanced group (69 knees) in which the difference between varus and valgus was less than 2°, the mean ROM improved significantly from 107.6° to 117.7° (p < 0.0001). By contrast, in the 11 knees which were unbalanced and in which the difference between varus and valgus laxity exceeded 2°, the ROM decreased from a mean of 121.0° to 112.7° (p = 0.0061). We conclude that coronal laxity, especially balanced laxity, is important for achieving an improved ROM in mobile-bearing total knee arthroplasty.


Lower Limb
Access Required
M. Lemon H. S. Somayaji A. Khaleel D. S. Elliott

Fragility fractures of the ankle occur mainly in elderly osteoporotic women. They are inherently unstable and difficult to manage. There is a high incidence of complications with both non-operative and operative treatment.

We treated 12 such fractures by closed reduction and stabilisation using a retrograde calcaneotalotibial expandable nail. The mean age of patients was 84 years (75 to 95). All were women and were able to walk fully weight-bearing after surgery. There were no wound complications. One patient died from a myocardial infarction 24 days after surgery. The 11 other patients were followed up for a mean of 67 weeks (39 to 104).

All the fractures maintained satisfactory alignment and healed without delay. Six patients refused removal of the nail after union of the fracture. The functional rating using the scale of Olerud and Molander gave a mean score at follow-up of 61, compared with a pre-injury value of 70.


A. Ince K. Seemann L. Frommelt A. Katzer J. F. Loehr

There are few reports in the literature of the diagnosis and treatment of the infected shoulder arthroplasty. Most deal with resection arthroplasty and two-stage exchange surgery. We present our results of one-stage exchange operation as treatment for the infected shoulder arthroplasty.

Our group comprised 16 patients (ten men, six women) with 16 infected arthroplasties. By the time of follow-up, two patients had died (mean 5.8 years), two could not be located and three had already undergone revision surgery. Nine patients were thus available for clinical examination and assessment.

The infections were largely caused by staphylococci, Propionibacterium species and streptococci. Two were early infections (within three months of surgery) and 14 were late infections. The mean follow-up was 5.8 years (13 months to 13.25 years) when the mean Constant-Murley score was 33.6 points and the mean University College of Los Angeles score 18.3 points.

Further revision was performed in three patients. One sustained a peri-prosthetic humeral fracture, another developed an acromial pseudarthrosis after transacromial surgery and the third suffered recurrent dislocations. No patient had a recurrence of infection.

A one-stage exchange procedure using antibiotic-loaded bone cement eradicated infection in all our patients and we suggest that such a procedure is at least as successful as either a resection arthroplasty or a two-stage exchange in the management of the infected shoulder arthroplasty.


T. D. Boehm A. Werner S. Radtke T. Mueller S. Kirschner F. Gohlke

In a prospective, randomised study on the repair of tears of the rotator cuff we compared the clinical results of two suture techniques for which different suture materials were used.

We prospectively randomised 100 patients with tears of the rotator cuff into two groups. Group 1 had transosseous repair with No. 3 Ethibond using modified Mason-Allen sutures and group 2 had transosseous repair with 1.0 mm polydioxanone cord using modified Kessler sutures. After 24 to 30 months the patients were evaluated clinically using the Constant score and by ultrasonography.

Of the 100 patients, 92 completed the study. No significant statistical difference was seen between the two groups: Constant score, 91% vs 92%; rate of further tear, 18% vs 22%; and revision, 4% vs 4%. In cases of further tear the outcome in group 2 did not differ from that for the intact repairs (91% vs 91%), but in group 1 it was significantly worse (94% vs 77%, p = 0.005).

Overall, seven patients had complications which required revision surgery, in four for pain (two in each group) and in three for infection (two in group 1 and one in group 2).


C. Charousset L. Bellaïche L. D. Duranthon J. Grimberg

CT arthrography and arthroscopy were used to assess tears of the rotator cuff in 259 shoulders. Tear size was determined in the frontal and sagittal planes according to the classification of the French Arthroscopy Society.

CT arthrography had a sensitivity of 99% and a specificity of 100% for the diagnosis of tears of supraspinatus. For infraspinatus these figures were 97.44% and 99.52%, respectively and, for subscapularis, 64.71% and 98.17%. For lesions of the long head of the biceps, the sensitivity was 45.76% and the specificity was 99.57%.

Our study showed an excellent correlation between CT arthrography and arthroscopy when assessing the extent of a rotator cuff tear. CT arthrography should, therefore, be an indispensable part of pre-operative assessment. It allows determination of whether a tear is reparable (retraction of the tendon and fatty degeneration of the corresponding muscle) and whether this is possible by arthroscopy (degree of tendon retraction and extension to subscapularis).


H. J. Kreder D. P. Hanel J. Agel M. McKee E. H. Schemitsch T. E. Trumble D. Stephen

A total of 179 adult patients with displaced intra-articular fractures of the distal radius was randomised to receive indirect percutaneous reduction and external fixation (n = 88) or open reduction and internal fixation (n = 91). Patients were followed up for two years. During the first year the upper limb musculoskeletal function assessment score, the SF-36 bodily pain sub-scale score, the overall Jebsen score, pinch strength and grip strength improved significantly in all patients. There was no statistically significant difference in the radiological restoration of anatomical features or the range of movement between the groups.

During the period of two years, patients who underwent indirect reduction and percutaneous fixation had a more rapid return of function and a better functional outcome than those who underwent open reduction and internal fixation, provided that the intra-articular step and gap deformity were minimised.


T. Azzopardi S. Ehrendorfer T. Coulton M. Abela

We performed a prospective, randomised study on 57 patients older than 60 years of age with unstable, extra-articular fractures of the distal radius to compare the outcome of immobilisation in a cast alone with that using supplementary, percutaneous pinning.

Patients treated by percutaneous wires had a statistically significant improvement in dorsal angulation (mean 7°), radial length (mean 3 mm) and radial inclination (mean 3 mm) at one year. However, there was no significant difference in functional outcome in terms of pain, range of movement, grip strength, activities of daily living and the SF-36 score except for an improved range of movement in ulnar deviation in the percutaneous wire group. One patient developed a pin-track infection which required removal of the wires at two weeks.

We conclude that percutaneous pinning of unstable, extra-articular fractures of the distal radius provides only a marginal improvement in the radiological parameters compared with immobilisation in a cast alone. This does not correlate with an improved functional outcome in a low-demand, elderly population.


Access Required
M. M. Zamzam K. I. Khoshhal

We retrospectively reviewed 183 children with a simple fracture of the distal radius, with or without fracture of the ulna, treated by closed reduction and cast immobilisation. The fracture redisplaced after an initial, acceptable closed reduction in 46 (25%). Complete initial displacement was identified as the most important factor leading to redisplacement. Other contributing factors were the presence of an ipsilateral distal ulnar fracture, and the reduction of completely displaced fractures under deep sedation or local haematoma block. We recommend that completely displaced fractures of the distal radius in children should be reduced under general anaesthesia, and fixed by primary percutaneous Kirschner wires even when a satisfactory closed reduction has been achieved.


Arthroplasty
Access Required
S. Ridgeway J. Wilson A. Charlet G. Kafatos A. Pearson R. Coello

We wished to estimate the incidence of surgical-site infection (SSI) after total hip replacement (THR) and hemiarthroplasty and its strength of association with major risk factors. The SSI surveillance service prospectively gathered clinical, operative and infection data on inpatients from 102 hospitals in England during a four-year period.

The overall incidence of SSI was 2.23% for 16 291 THRs, 4.97% for 5769 hemiarthroplasty procedures, 3.68% for 2550 revision THRs and 7.6% for 198 revision hemiarthroplasties. Staphylococcus aureus was identified in 50% of SSIs; 59% of these isolates were methicillin-resistant (MRSA). In the single variable analysis of THRs, age, female gender, American Society of Anesthesiologists (ASA) score, body mass index, trauma, duration of operation and pre-operative stay were significantly associated with the risk of SSI (p < 0.05). For hemiarthroplasty, the ASA score and age were significant factors. In revision THRs male gender, ASA score, trauma, wound class, duration of operation and pre-operative stay were significant risk factors. The median time to detection of SSI was eight days for superficial incisional, 11 days for deep incisional and 11 days for joint/bone infections. For each procedure the mean length of stay doubled for patients with SSI. The multivariate analysis identified age group, trauma, duration of operation and ASA score as significant, independent risk factors for SSI. There was significant interhospital variation in the rates of SSI. MRSA was the most common pathogen to cause SSI in hip arthroplasty, especially in patients undergoing hemiarthroplasty, but coagulase-negative Staph. aureus may be more important in deep infections involving the joint.


A. W. Davidson A. Hong S. W. McCarthy P. D. Stalley

We treated 50 patients with bony malignancy by en-bloc resection, extracorporeal irradiation with 50 Gy and re-implantation of the bone segment.

The mean survivor follow-up was 38 months (12 to 92) when 42 patients were alive and without disease. There were four recurrences. The functional results were good according to the Mankin score (17 excellent, 13 good, nine fair, three failures), the Musculoskeletal Tumour Society score (mean 77) and the Toronto Extremity Salvage score (mean 81). There was solid union, but bone resorption was seen in some cases. The dose of radiation was lethal to all cells and produced a dead autograft of perfect fit.

Extracorporeal irradiation is a useful technique for limb salvage when there is reasonable residual bone stock. It allows effective re-attachment of tendons and produces a lasting biological reconstruction. There should be no risk of local recurrence or of radiotherapy-induced malignancy in the replanted bone.


Children's Orthopaedics
Access Required
O. Lahoti M. J. Bell

We present the long-term results of pectoralis major transfer to restore elbow flexion in seven patients (ten procedures). The early results in all the patients were encouraging but with longer follow-up a gradual and progressive flexion deformity was observed with a decrease in the arc of flexion in eight elbows, reaching ≥ 90° in all cases.

The results of pectoralis major transfer deteriorate with time due to the development of a recalcitrant flexion deformity of the elbow. With bilateral involvement we now recommend that the procedure be undertaken on one side only to allow the hand to reach the mouth for feeding, while the opposite side remains in extension for perineal toilet.


A. S. Montgomery R. Birch A. Malone

We present a case of disruption of the posterolateral corner of the knee with avulsion of the tendon of biceps femoris. Repair and reconstruction included an allogenic tendon graft to replace the posterior cruciate ligament. Surgery was followed by a complete common peroneal nerve palsy. Revision surgery revealed that the nerve had been displaced anteriorly by avulsion of the biceps tendon and the tendon graft encircled it. Release of the nerve restored normal function at five months.


K. Nagarajah N. Aslam P. McLardy Smith M. McNally

We describe a technique of ‘cross-hip distraction’ to reduce a dislocated hip with subsequent reconstruction of the joint for septic arthritis with extensive femoral osteomyelitis. A 27-year-old woman presented with a dislocated, collapsed femoral head and chronic osteomyelitis of the femur. Examination revealed a leg-length discrepancy of 7 cm and an irritable hip. A staged technique was used with primary clearance of osteomyelitis and secondary reconstruction of the hip. A cross-hip monolateral external fixator was used to establish normal anatomy followed by an arthroplasty. A good functional outcome was achieved. The use of cross-hip distraction avoids soft-tissue and nerve damage and achieved improved abductor function before arthroplasty.


A. J. Metcalfe M. Saleh L. Yang

Biomechanical studies involving all-wire and hybrid types of circular frame have shown that oblique tibial fractures remain unstable when they are loaded. We have assessed a range of techniques for enhancing the fixation of these fractures. Eight models were constructed using Sawbones tibiae and standard Sheffield ring fixators, to which six additional fixation techniques were applied sequentially.

The major component of displacement was shear along the obliquity of the fracture. This was the most sensitive to any change in the method of fixation. All additional fixation systems were found to reduce shear movement significantly, the most effective being push-pull wires and arched wires with a three-hole bend. Less effective systems included an additional half pin and arched wires with a shallower arc. Angled pins were more effective at reducing shear than transverse pins.

The choice of additional fixation should be made after consideration of both the amount of stability required and the practicalities of applying the method to a particular fracture.


M. J. Oddy C. J. Pendegrass A. E. Goodship S. R. Cannon T. W. R. Briggs G. W. Blunn

We developed an in vivo model of the attachment of a patellar tendon to a metal implant to simulate the reconstruction of an extensor mechanism after replacement of the proximal tibia. In 24 ewes, the patellar tendon was attached to a hydroxyapatite (HA)-coated titanium prosthesis. In 12, the interface was augmented with autograft containing cancellous bone and marrow. In the remaining ewes, the interface was not grafted.

Kinematic gait analysis showed nearly normal function of the joint by 12 weeks. Force-plate assessment showed a significant increase in functional weight-bearing in the grafted animals (p = 0.043). The tendon-implant interface showed that without graft, encapsulation of fibrous tissue occurred. With autograft, a developing tendon-bone-HA-implant interface was observed at six weeks and by 12 weeks a layered tendon-fibrocartilage-bone interface was seen which was similar to a direct-type enthesis.

With stable mechanical fixation, an appropriate bioactive surface and biological augmentation the development of a functional tendon-implant interface can be achieved.


M. Diab J. M. Poston P. Huber A. F. Tencer

Repeated trauma to the radial head may be one of the causative factors in the genesis of osteochondritis dissecans of the capitellum. We measured the force, contact area and pressure across the radiocapitellar articulation of the elbow before and after radial shortening osteotomy in five fresh-frozen cadaver upper limbs with loads of 45, 90 and 135 N, respectively. Measurements were made on pressure-sensitive film placed in the radiocapitellar articulation with the forearm in the supinated, neutral and pronated positions before and after radial shortening. Radial shortening significantly reduced the mean force and contact area across the radiocapitellar articulation in all positions of the forearm.



J. GIBBS D. RICKETTS

Access Required

Access Required

Errata
Errata Pages 886 - 886
Access Required