header advert
The Bone & Joint Journal Logo

Receive monthly Table of Contents alerts from The Bone & Joint Journal

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Volume 87-B, Issue 4 April 2005

Total elbow arthroplasty Pages 437 - 444
Access Required
C. P. Little A. J. Graham A. J. Carr
View article
Download PDF

Access Required
G. D. Smith G. Knutsen J. B. Richardson
View article
Download PDF

N. D. Reis O. S. Better
View article
Download PDF

S. Kaspar J. de V de Beer
View article
Download PDF

Immunosuppression following intra-articular injections of steroid into the hip may interfere with asepsis in a subsequent total hip arthroplasty (THA). We have undertaken a retrospective, matched, cohort study of infective complications after THA, in 40 patients who had received such an injection and 40 who had not.

In the injection group there were five revisions, four of which were for deep infection. There were none in the matched group. The overall rate of revision in our database of 979 primary THAs was 1.02%. Six additional patients who had received injections underwent investigation for infection because of persistent problems in the hip as compared with one in the control group.


Access Required
N. P. Walton C. Darrah L. Shepstone S. T. Donell H. Phillips
View article
Download PDF

We prospectively studied 217 patients who underwent 234 Elite Plus total hip arthroplasties. At a mean of 6.4 (SD 0.7) years post-operatively, 39 patients had died and 22 were either lost to follow-up or had no radiographs available. Clinical (Oxford hip score) and radiological assessments were performed on 156 patients (168 hip arthroplasties) who had a mean age of 67.7 (SD 9.7) years at operation.

In the assessed group, 26 of 159 (16.4%) of femoral stems which had not already been revised and 19 of 159 (11.9%) of acetabular cups were definitely loose. In total, 52 of 168 (31%) of hips had either been revised or had definite evidence of loosening of a component. We could not establish any relationship between clinical and radiological outcomes.

Despite the fact that the clinical outcome and rate of revision for the Elite Plus appeared to meet international standards, our findings give us cause for concern. We believe that joint registries should include radiological surveillance in order to provide reliable information about medium-term outcomes for hip prostheses.


A. J. Shimmin D. Back
View article
Download PDF

Between April 1999 and April 2004, 3497 Birmingham hips were inserted by 89 surgeons. Fracture of the neck of the femur occurred in 50 patients, an incidence of 1.46%. Complete data were available for 45 patients in whom the incidence was 1.91% for women and 0.98% for men. The relative risk of fracture for women vs men was 1.94961 and this was statistically significant (p < 0.01).

The mean time to fracture was 15.4 weeks. In women the fractures occurred at a mean of 18.5 weeks and were more likely to have been preceded by a pro-dromal phase of pain and limping. In men the mean time to fracture was 13.5 weeks.

Significant varus placement of the femoral component, intra-operative notching of the femoral neck and technical problems were common factors in 85% of cases.


P. Reinartz T. Mumme B. Hermanns U. Cremerius D. C. Wirtz W. M. Schaefer F.-U. Niethard U. Buell
View article
Download PDF

Two major complications of hip replacement are loosening and infection. Reliable differentiation between these pathological processes is difficult since both may be accompanied by similar symptoms. Our aim was to assess the diagnostic ability of triple-phase bone scanning (TPBS) and positron-emission tomography (PET) to detect and differentiate these complications in patients with a hip arthroplasty. Both TPBS and PET were performed in 63 patients (92 prostheses). The radiotracer for PET imaging was 18F-fluorodeoxyglucose (FDG). Image interpretation was performed according to qualitative and quantitative criteria although the final diagnosis was based upon either surgical findings or clinical follow-up.

The sensitivity, specificity and accuracy of PET was 0.94, 0.95 and 0.95 respectively, compared with 0.68, 0.76 and 0.74 for TPBS. We found that an image interpretation based exclusively upon quantitative criteria was inappropriate because of its low selectivity. The histological examination indicated that increased periprosthetic uptake of FDG in patients with aseptic loosening was caused by wear-induced polyethylene particles and the subsequent growth of aggressive granulomatous tissue.


Access Required
S. Jacobsen S. Sonne-Holm K. Søballe P. Gebuhr B. Lund
View article
Download PDF

In a longitudinal case-control study, we followed 81 subjects with dysplasia of the hip and 136 control subjects without dysplasia for ten years assessing radiological evidence of degeneration of the hip at admission and follow-up. There were no cases of subluxation in the group with dysplasia. Neither subjects with dysplasia nor controls had radiological signs of ongoing degenerative disease at admission. The primary radiological discriminator of degeneration of the hip was a change in the minimum joint space width over time. There were no significant differences between these with dysplasia and controls in regard to age, body mass index or occupational exposure to daily repeated lifting at admission.

We found no significant differences in the reduction of the joint space width at follow-up between subjects with dysplasia and the control subjects nor in self-reported pain in the hip. The association of subluxation and/or associated acetabular labral tears with dysplasia of the hip may be a conditional factor for the development of premature osteoarthritis in mildly to moderately dysplastic hips.


M. C. Oliver O. D. Keast-Butler B. L. Hinves J. A. N. Shepperd
View article
Download PDF

We report the clinical and radiographic outcome of a consecutive series of 138 hydroxyapatite-coated total knee replacements with a mean follow-up of 11 years (10 to 13). The patients were entered into a prospective study and all living patients (76 knees) were evaluated. The Hospital for Special Surgery knee score was obtained for comparison with the pre-operative situation. No patient was lost to follow-up. Radiographic assessment revealed no loosening. Seven prostheses have been revised, giving a cumulative survival rate of 93% at 13 years. We believe this to be the longest follow-up report available for an hydroxyapatite-coated knee replacement and the first for this design of Insall-Burstein II knee.


K. Nakayama S. Matsuda H. Miura H. Higaki K. Otsuka Y. Iwamoto
View article
Download PDF

We measured the contact areas and contact stresses at the post-cam mechanism of a posterior-stabilised total knee arthroplasty when a posterior force of 500 N was applied to the Kirschner Performance, Scorpio Superflex, NexGen LPS Flex Fixed, and NexGen LPS Flex Mobile knee systems. Measurements were made at 90°, 120°, and 150° of flexion both in neutral rotation and 10° of internal rotation of the tibial component. Peak contact stresses at 90°, 120°, and 150° were 24.0, 33.9, and 28.8 MPa, respectively, for the Kirschner; 26.0, 32.4, and 22.1 MPa, respectively, for the Scorpio; and 34.1, 31.5, and 32.5 MPa, respectively, for the NexGen LPS Flex Fixed. With an internally rotated tibia, the contact stress increased significantly with all the fixed-bearing arthroplasties but not with the NexGen LPS Flex Mobile arthroplasty. The post-cam design should be modified in order to provide a larger contact area whilst avoiding any impingement and edge loading.


Lower Limb
Access Required
K. B. Jones K. A. Maiers-Yelden J. L. Marsh M. B. Zimmerman M. Estin C. L. Saltzman
View article
Download PDF

Diabetes mellitus is considered an indicator of poor prognosis for acute ankle fractures, but this risk may be specific to an identifiable subpopulation. We retrospectively reviewed 42 patients with both diabetes mellitus and an acute, closed, rotational ankle fracture. Patients were individually matched to controls by age, gender, fracture type, and surgical vs non-surgical treatment. Outcomes were major complications during the first six months of treatment. We contrasted secondarily 21 diabetic patients with and 21 without diabetic comorbidities. Diabetic patients and controls did not differ significantly in total complication rates. More diabetic patients required long-term bracing. Diabetic patients without comorbidities had complication rates equal to their controls. Diabetic patients with comorbidities had complications at a higher rate (ten patients; 47%) than matched controls (three patients; 14%, p = 0.034). A history of Charcot neuroarthropathy led to the highest rates of complication. An increased risk of complications in diabetic patients with closed rotational fractures of the ankle are specific to a subpopulation with identifiable related comorbidities.


J. Mileti J. W. Sperling R. H. Cofield J. R. Harrington T. L. Hoskin
View article
Download PDF

There are theoretical and practical advantages to modular rather than monoblock designs of prostheses for shoulder arthroplasty, but there are no reported studies which specifically compare the clinical and radiological results of their use. We have compared the results of unconstrained total shoulder arthroplasty for osteoarthritis using both types of implant. The monoblock design was used between 1992 and 1995 and the modular design after 1995. Both had cemented all-polyethylene glenoids, the monoblock with matched and the modular with mismatched radii of curvature. There were 34 consecutive shoulders in each group with a mean follow-up of 6.1 years in the first and 5.2 years in the second.

There were no significant differences in improvement of pain scores, active elevation, external rotation, internal rotation, patient satisfaction, or the Neer ratings between the two groups. Two of 28 glenoid components in the first group and six of 30 in the second met the criteria for being radiologically at risk for loosening (p = 0.25). There were no significant differences in clinical outcome or radiological changes between the first- and second-generation designs of implant for shoulder arthroplasty.


C. Krasny M. Enenkel N. Aigner M. Wlk F. Landsiedl
View article
Download PDF

We carried out a prospective, randomised controlled trial on two groups of 40 patients with painful calcific tendonitis and a mean age of 48.4 years (32.5 to 67.3). All were to undergo arthroscopic removal of the calcific deposit within six months after randomisation. The 40 patients in group I received ultrasound-guided needling followed by high-energy shock-wave therapy and the 40 in group II had shock-wave therapy alone. In both groups one treatment consisting of 2500 impulses of shock waves with an energy flux density of 0.36 mJ/mm2 was applied. The clinical and radiological outcome was assessed using the 100-point Constant shoulder scoring system and standardised radiographs. The mean follow-up was 4.1 months and no patient was lost to follow-up.

Both groups had significant improvement in their Constant shoulder score. Radiographs showed disappearance of the calcific deposit in 60.0% of the shoulders in group I and in 32.5% of group II (p < 0.05). Significantly better clinical and radiological results were obtained in group I than in group II. Arthroscopic removal of the deposit was avoided in 32 patients of group I and in 22 of group II. No severe side-effects were recorded.

Ultrasound-guided needling in combination with high-energy shock-wave therapy is more effective than shock-wave therapy alone in patients with symptomatic calcific tendonitis, giving significantly higher rates of elimination of the calcium deposits, better clinical results and reduction in the need for surgery.


J. Lafuente A. T. H. Casey A. Petzold S. Brew
View article
Download PDF

We present data relating to the Bryan disc arthroplasty for the treatment of cervical spondylosis in 46 patients.

Patients with either radiculopathy or myelopathy had a cervical discectomy followed by implantation of a cervical disc prosthesis. Patients were reviewed at six weeks, six months and one year and assessment included three outcome measures, a visual analogue scale (VAS), the short form 36 (SF-36) and the neck disability index (NDI). The results were categorised according to a modification of Odom’s criteria. Radiological evaluation, by an independent radiologist, sought evidence of movement, stability and subsidence of the prosthesis.

A highly significant difference was found for all three outcome measurements, comparing the pre-operative with the post-operative values: VAS (Z = 6.42, p < 0.0001), SF-36 (mental component) (Z = −5.02, p < 0.0001), SF-36 (physical component) (Z = −5.00, p < 0.0001) and NDI (Z = 7.03, p < 0.0001). The Bryan cervical disc prosthesis seems reliable and safe in the treatment of patients with cervical spondylosis.


Access Required
T. Mahmud D. Basu P. H. P. Dyson
View article
Download PDF

There have been very few reports in the literature of gout and pseudogout of the spine. We describe six patients who presented with acute sciatica attributable to spinal stenosis with cyst formation in the facet joints. Cytopathological studies confirmed the diagnosis of crystal arthropathy in each case.

Specific formation of a synovial cyst was identified pre-operatively by MRI in five patients. In the sixth, the diagnosis was made incidentally during decompressive surgery. Surgical decompression alone was undertaken in four patients. In one with an associated degenerative spondylolisthesis, an additional intertransverse fusion was performed. Another patient had previously undergone a spinal fusion adjacent to the involved spinal segment, and spinal stabilisation was undertaken as well as a decompression.

In addition to standard histological examination material was sent for examination under polarised light which revealed deposition of urate or calcium pyrophosphate dihydrate crystals in all cases.

It is not possible to diagnose gout and pseudogout of the spine by standard examination of a fixed specimen. However, examining dry specimens under polarised light suggests that crystal arthropathy is a significant aetiological factor in the development of symptomatic spinal stenosis associated with cyst formation in a facet joint.


S. W. Suh V. U. Shingade S. H. Lee J. H. Bae C. E. Park J. Y. Song
View article
Download PDF

Previous studies on the anatomy of the lumbar spine have not clarified the precise relationship of the origin of the lumbar roots to their corresponding discs or their angulation to the dural sac. We studied 33 cadavers (25 formalin-preserved and eight fresh-frozen) and their radiographs to determine these details.

All cadavers showed a gradual decrease in the angle of the nerve root from L1 to S1. The origin of the root was found to be below the corresponding disc for the L1 to L4 roots. In the formalin-preserved cadavers 8% of the L5 roots originated above, 64% below and 28% at the L4/L5 disc. In the fresh cadavers the values were 12.5%, 62.5% and 25%, respectively. For the S1 root 76% originated above and 24% at the L5-S1 disc in the formalin-preserved cadavers and 75% and 25%, respectively, in the fresh cadavers.

A herniated disc usually compresses the root before division of the root sleeve. Thus, compression of the thecal sac before the origin of the root sleeve is common for L1 to L5 whereas compression at the root sleeve is common for S1.

Our findings are of value in understanding the pathophysiology of prolapse of the disc and in preventing complications during surgery.


R. Blomfeldt H. Törnkvist S. Ponzer A. Söderqvist J. Tidermark
View article
Download PDF

We studied 60 patients with an acute displaced fracture of the femoral neck and with a mean age of 84 years. They were randomly allocated to treatment by either internal fixation with cannulated screws or hemiarthroplasty using an uncemented Austin Moore prosthesis. All patients had severe cognitive impairment, but all were able to walk independently before the fracture. They were reviewed at four, 12 and 24 months after surgery. Outcome assessments included complications, revision surgery, the status of activities of daily living (ADL), hip function according to the Charnley score and the health-related quality of life (HRQOL) according to the Euroqol (EQ-5D) (proxy report).

General complications and the rate of mortality at two years (42%) did not differ between the groups. The rate of hip complications was 30% in the internal fixation group and 23% in the hemiarthroplasty group; this was not significant. There was a trend towards an increased number of re-operated patients in the internal fixation group compared with the hemiarthroplasty group, 33% and 13%, respectively (p = 0.067), but the total number of surgical procedures which were required did not differ between the groups. Of the survivors at two years, 54% were totally dependent in ADL functions and 60% were bedridden or wheelchair-bound regardless of the surgical procedure. There was a trend towards decreased mobility in the hemiarthroplasty group (p = 0.066). All patients had a very low HRQOL even before the fracture. The EQ-5Dindex score was significantly worse in the hemiarthroplasty group compared with the internal fixation group at the final follow-up (p < 0.001).

In our opinion, there is little to recommend hemiarthroplasty with an uncemented Austin Moore prosthesis compared with internal fixation, in patients with severe cognitive dysfunction.


Major pelvic fractures Pages 530 - 533
Access Required
R. E. M. O’Sullivan T. O. White J. F. Keating
View article
Download PDF

The identification of high-risk factors in patients with fractures of the pelvis at the time of presentation would facilitate investigation and management. In a series of 174 consecutive patients with unstable fractures of the pelvic ring, clinical data were used to calculate the injury severity score (ISS), the triage-revised trauma score (T-RTS), and the Glasgow coma scale (GCS). The morphology of the fracture was classified according to the AO system and that of Burgess et al. The data were analysed using univariate and multivariate methods in order to determine which presenting features were identified with high risk.

Univariate analysis showed an association between mortality and an ISS over 25, a T-RTS below eight, age over 65 years, systolic blood pressure under 100 mmHg, a GCS of less than 8, blood transfusion of more than ten units in the first 24 hours and colloid infusion of more than six litres in the first 24 hours. Multivariate analysis showed that age, T-RTS and ISS were independent determinants of mortality. A T-RTS of eight or less identified the cohort of patients at greatest risk (65%). The morphology of the fracture was not predictive of mortality. We recommend the use of the T-RTS in the acute situation in order to identify patients at high risk.


Oncology
Triplate fixation Pages 534 - 539
Access Required
J. P. Cobb N. Ashwood G. Robbins J. D. Witt P. S. Unwin G. Blunn
View article
Download PDF

Massive endoprostheses using a cemented intramedullary stem are widely used to allow early resumption of activity after surgery for tumours. The survival of the prosthesis varies with the anatomical site, the type of prosthesis and the mode of fixation. Revision surgery is required in many cases because of aseptic loosening. Insertion of a second cemented endoprosthesis may be difficult because of the poor quality of the remaining bone, and loosening recurs quickly.

We describe a series of 14 patients with triplate fixation in difficult revision or joint-sparing tumour surgery with a minimum follow-up of four years. The triplate design incorporated well within a remodelled cortex to achieve osseomechanical integration with all patients regaining their original level of function within five months.

Our preliminary results suggest that this technique may provide an easy, biomechanically friendly alternative to insertion of a further device with an intramedullary stem, which has a shorter lifespan in revision or joint-sparing tumour surgery. A short segment of bone remaining after resection of a tumour will not accept an intramedullary stem, but may be soundly fixed using this method.


Children's Orthopaedics
Access Required
K. Kazuki K. Hiroshima K. Kawahara
View article
Download PDF

Deformity of the forearm due to growth disturbance of the ulna occurs in a number of conditions such as ulnar deficiency, multiple exostoses, and neurofibromatosis. We report a previously unrecognised form, caused by focal cortical indentation.

We have treated five children with this condition, three girls and two boys; the mean age at presentation was 5 years (2 to 8). The deformity was first recognised about the age of two years, and progressed gradually. The radiological findings were the same in all cases. The focal cortical indentation was seen at the distal end of the ulna with anteromedial bowing and dysplasia. The radial head was dislocated posterolaterally. In one patient the histological findings at the site of indentation were of a fold of tissue resembling periosteum, which interfered with enchondral ossification. Treatment by ulnar lengthening using an external fixator and osteotomy which corrected both the ulnar deformity and reduced the dislocated radial head in two cases gave the best results.


D. A. Katz Y.-J. Kim M. B. Millis
View article
Download PDF

We treated eight dysplastic acetabula in six skeletally mature patients with Down’s syndrome by a modified Bernese periacetabular osteotomy. The mean age at the time of surgery was 16.5 years (12.8 to 28.5). Mean length of follow-up was five years (2 to 10.4).

Pre-operatively the mean (Tönnis) acetabular angle was 28°, the centre-edge angle was −9°, and the extrusion index was 60%; post-operatively they were 3°, 37°, and 17%, respectively. Two patients with post-operative (Tönnis) acetabular angles > 10° developed subluxation post-operatively and required secondary varus derotation femoral osteotomies. Another patient developed a late labral tear which was treated arthroscopically. All eight hips remain clinically stable, and are either asymptomatic or symptomatically improved.

These results suggest that the modified Bernese periacetabular osteotomy can be used successfully in the treatment of acetabular dysplasia in patients with Down’s syndrome.


F. Dobson H. Kerr Graham R. Baker M. E. Morris
View article
Download PDF

Most children with spastic hemiplegia have high levels of function and independence but fixed deformities and gait abnormalities are common. The classification proposed by Winters et al is widely used to interpret hemiplegic gait patterns and plan intervention. However, this classification is based on sagittal kinematics and fails to consider important abnormalities in the transverse plane. Using three-dimensional gait analysis, we studied the incidence of transverse-plane deformity and gait abnormality in 17 children with group IV hemiplegia according to Winters et al before and after multilevel orthopaedic surgery.

We found that internal rotation of the hip and pelvic retraction were consistent abnormalities of gait in group-IV hemiplegia. A programme of multilevel surgery resulted in predictable improvement in gait and posture, including pelvic retraction. In group IV hemiplegia pelvic retraction appeared in part to be a compensating mechanism to control foot progression in the presence of medial femoral torsion. Correction of this torsion can improve gait symmetry and function.


General Orthopaedics
Access Required
M. Al-Maiyah A. Bajwa P. Finn P. Mackenney D. Hill A. Port P. J. Gregg
View article
Download PDF

We conducted a randomised, controlled trial to determine whether changing gloves at specified intervals can reduce the incidence of glove perforation and contamination in total hip arthroplasty. A total of 50 patients were included in the study. In the study group (25 patients), gloves were changed at 20-minute intervals or prior to cementation. In the control group (25 patients), gloves were changed prior to cementation. In addition, gloves were changed in both groups whenever there was a visible puncture. Only outer gloves were investigated.

Contamination was tested by impression of gloved fingers on blood agar and culture plates were subsequently incubated at 37°C for 48 hours. The number of colonies and types of organisms were recorded. Glove perforation was assessed using the water test. The incidence of perforation and contamination was significantly lower in the study group compared with the control group. Changing gloves at regular intervals is an effective way to decrease the incidence of glove perforation and bacterial contamination during total hip arthroplasty.


A. C. Disch G. Matziolis C. Perka
View article
Download PDF

Bone-marrow oedema can occur both in isolation and in association with necrosis of bone, but it has not been shown whether each respond to the same methods of treatment.

We treated 16 patients with isolated oedema and 17, in which it was associated with necrosis of the proximal femur, with the prostacyclin derivative iloprost, which has been shown to be effective in the idiopathic form. The Harris hip score, the range of movement, the extent of the oedema as measured by MRI, pain on a visual analogue scale and patient satisfaction were recorded before and subsequent to treatment.

In both groups, we were able to show a significant improvement (p < 0.001) in these observations during the period of follow-up indicating that iloprost will produce clinical improvement in both circumstances.


R. Baumgart M. Krammer A. Winkler S. Hinterwimmer O. Muensterer W. Mutschler
View article
Download PDF

We report the case of a 22-year-old woman who underwent plate and screw fixation for a traumatic left acetabular fracture and fixation with cancellous screws for an associated femoral neck fracture. Two months later, the internal fixation became infected and was removed. This resulted in a painful high dislocation of the hip. We solved the problem with continuous soft-tissue distraction using a fully implantable motorised distraction nail in order to reduce the proximal femur prior to total hip arthroplasty. To our knowledge, this is the first time that reduction of a high dislocation of the hip has been performed using such a system.


S. D. Muller M. Al-Maiyah A. C. Hui A. O. Adedapo
View article
Download PDF

We describe a patient who sustained a widely displaced, high-energy, mid-shaft clavicular fracture in association with brachial plexus damage. The distal fragment was subsequently found to have penetrated the thoracic cavity. We describe the treatment of this rare injury with a successful outcome.


L. Savarino D. Granchi E. Cenni N. Baldini M. Greco A. Giunti
View article
Download PDF

There is no diagnostic, non-invasive method for the early detection of loosening after total hip arthroplasty. In a pilot study, we have analysed two serum markers of bone remodelling, procollagen I C-terminal extension peptide (PICP) and cross-linked N-terminal telopeptide (NTx), as well as the diagnostic performance of NTx for the assessment of osteolysis. We recruited 21 patients with loosening (group I), 18 with a well-fixed prosthesis (group II) and 17 at the time of primary arthroplasty for osteoarthritis (OA) (group III). Internal normal reference ranges were obtained from 30 healthy subjects (group IV).

The serum PICP level was found to be significantly lower in patients with OA and those with loosening, when compared with those with stable implants, while the NTx level was significantly increased only in the group with loosening, suggesting that collagen degradation depended on the altered bone turnover induced by the implant. This hypothesis was reinforced by the finding that the values in the pre-surgery patients and stable subjects were comparable with the reference range of younger healthy subjects.

A high specificity and positive predictive value for NTx provided good diagnostic evidence of agreement between the test and the clinical and radiological evaluations. The NTx level could be used to indicate stability of the implant. However, further prospective, larger studies are necessary.


W. Senavongse A. A. Amis
View article
Download PDF

Normal function of the patellofemoral joint is maintained by a complex interaction between soft tissues and articular surfaces. No quantitative data have been found on the relative contributions of these structures to patellar stability. Eight knees were studied using a materials testing machine to displace the patella 10 mm laterally and medially and measure the force required. Patellar stability was tested from 0° to 90° knee flexion with the quadriceps tensed to 175 N. Four conditions were examined: intact, vastus medialis obliquus relaxed, flat lateral condyle, and ruptured medial retinaculae. Abnormal trochlear geometry reduced the lateral stability by 70% at 30° flexion, while relaxation of vastus medialis obliquus caused a 30% reduction. Ruptured medial retinaculae had the largest effect at 0° flexion with 49% reduction. There was no effect on medial stability. There is a complex interaction between these structures, with their contributions to loss of lateral patellar stability varying with knee flexion.


Access Required
G. Szöke S.-H. Lee A. H. R. W. Simpson J. Prescott
View article
Download PDF

Little is known about the increase in length of tendons in postnatal life or of their response to limb lengthening procedures. A study was carried out in ten young and nine adult rabbits in which the tibia was lengthened by 20% at two rates 0.8 mm/day and 1.6 mm/day.

The tendon of the flexor digitorum longus (FDL) muscle showed a significant increase in length in response to lengthening of the tibia. The young rabbits exhibited a significantly higher increase in length in the FDL tendon compared with the adults. There was no difference in the amount of lengthening of the FDL tendon at the different rates. Of the increase in length which occurred, 77% was in the proximal half of the tendon.

This investigation demonstrated that tendons have the ability to lengthen during limb distraction. This occurred to a greater extent in the young who showed a higher proliferative response, suggesting that there may be less need for formal tendon lengthening in young children.


A. J. LANGDOWN J. AULD W. J. M. BRUCE
View article
Download PDF

Access Required
R. J. GRIMER A. ABUDU
View article
Download PDF

B. J. DAVIS
View article
Download PDF

Arthroplasty of the spine Pages 591 - 591
Access Required
R. Mulholland
View article
Download PDF