Full Access

General Orthopaedics

MEASURING THE MEDIAL TIBIAL OSTEOTOMY THICKNESS DURING SURGERY IS USEFUL FOR PREDICTING POST-OPERATIVE LIMB ALIGNMENT IN UNICOMPARTMENTAL KNEE ARTHROPLASTY

The International Society for Technology in Arthroplasty (ISTA), 29th Annual Congress, October 2016. PART 4.



Abstract

Background

Post-operative (postop) lower limb alignment in unicompartmental knee arthroplasty (UKA) has been reported to be an important factor for postop outcomes. Slight under-correction of limb alignment has been recommended to yield a better clinical outcomes than neutral alignment. It is useful if the postop limb alignment can be predicted during surgery, however, little is known about the surgical factors affecting the postop limb alignment in UKA. The purpose of this study was to examine the influence of the medial tibial joint line elevation on postop limb alignment in UKA.

Methods

Seventy-four consecutive medial UKAs were enrolled in this study. All the patients received a conventional fixed bearing UKA. Pre-operative (preop) and postop limb alignment was examined using long leg radiograph and lower limb alignment changes were calculated. Femoral and tibial osteotomy thickness were measured during surgery. Medial tibial joint line change was defined as polyethylene thickness minus tibial osteotomy thickness and sawblade thickness (1.27mm). Positive values indicated a tibial joint line elevation. Medial femoral joint line change was defined as femoral distal component thickness (6.5mm) minus femoral distal osteotomy thickness and sawblade thickness. Positive values indicated a femoral joint line reduction. Medial joint distraction width was also calculated by tibial joint line elevation plus femoral joint line reduction. The correlation of lower limb alignment change with polyethylene insert thickness, the medial tibial joint line elevation, femoral joint line reduction, or joint distraction width were analyzed.

Results

The mean preop hip-knee-ankle (HKA) angle was 7.1 ± 3.3° in varus and postop was 2.1 ± 3.0° in varus. The mean lower limb alignment change was 5.0 ± 2.6°. The mean polyethylene insert thickness was 8.5 ± 0.8mm, the tibial joint line elevation was 4.4 ± 1.3mm and the medial femoral joint line reduction was 0.0 ± 1.1mm, the joint distraction width was 4.5 ± 1.5mm. The polyethylene insert thickness, the medial tibial joint line elevation, and the joint distraction width were positively correlated with the lower limb alignment change (R=0.27; P<0.05, R=0.47; P<0.001, R=0.53; P<0.001, respectively) (Figure 1a,b,d). There was no correlation between the medial femoral joint line reduction and the lower limb alignment change (Figure 1c).

Discussion

The postop limb alignment in total knee arthroplasty (TKA) is determined by the osteotomy angle of the femur and tibia. On the other hand, it has been reported that the postop alignment in UKA is not influenced by the osteotomy angle but by the insert thickness. Our results indicated that the medial tibial joint line elevation and the joint distraction width were more useful to predict lower limb alignment change than the insert thickness itself. Measuring the medial tibial osteotomy thickness during surgery will help surgeon to predict postop lower limb alignment in UKA.

For any figures or tables, please contact authors directly (see Info & Metrics tab above).


*Email: