header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Children's Orthopaedics

THE EFFECTIVENESS OF “INCIDENTAL ANTENATAL SCREENING” FOR CONGENITAL TALIPES EQUINOVARUS: RESULTS FROM AN NHS UNIVERSITY TEACHING HOSPITAL

British Society for Children's Orthopaedic Surgery (BSCOS)



Abstract

Aim

Congenital Talipes Equinovarus (CTEV) has been excluded from the standards set by the NHS fetal anomaly screening programme (NHS FASP) for the 18+0–20+6 week fetal ultrasound scan (USS). Whilst adhering to NHS FASP guidelines, the antenatal ultrasound department at our centre performs “incidental screening” for CTEV; parents are informed if CTEV is noted incidentally during the scan and referral made to the fetal medicine department. Our aim was to investigate the effectiveness of incidental antenatal screening for structural CTEV.

Method

The database of the antenatal ultrasound department was interrogated for all suspected cases of CTEV on the 18+0–20+6 week USS, between August 2006 and June 2012. Terminations, stillbirths and outside referrals were excluded. Our Ponseti-service database was searched to identify all patients treated for structural CTEV between January 2007 and November 2012. Cases were excluded if the mother did not receive antenatal-care at our centre. Results from the two searches were cross-referenced, and statistical analysis performed.

Results

30077 18+0–20+6 week USS were performed on 24282 patients, with CTEV diagnosed in 74 patients. After exclusions, there were 39 patients. 54 patients were treated for structural CTEV with 37 patients (54 feet, CTEV-incidence 0.001) after exclusions; 25 (67.5%) diagnosed pre-natally (15 unilateral, 10 bilateral), and 12 (32.5%) diagnosed post-natally (5 unilateral, 7 bilateral). Sensitivity of screening for CTEV was 67.5%, specificity 99.8%, positive predictive value (PPV) 64.1% and negative predictive value 99.9%. The proportion of cases detected antenatally has reduced since introduction of NHS-FASP.

Conclusion

This data is important and necessary to comprehensively counsel our patients. We are unable to find similar contemporary data from other units within the NHS for comparison. NHS-FASP guidelines seem to have reduced the efficacy of antenatal detection of CTEV at our unit, and further prospective study is required to determine the value of screening for patients.