COMPLICATIONS AFTER UNICOMPARTMENTAL KNEE ARTHROPLASTY: A SINGLE-INSTITUTION STUDY

The International Society for Technology in Arthroplasty (ISTA), 29th Annual Congress, October 2016. PART 2.



Abstract

Background

To evaluate the causes and modes of complications after unicompartmental knee arthroplasty (UKA), and to identify its prevention and treatment method by analyzing the complications after UKA.

Materials and Methods

A total of 1,576 UKAs were performed between January 2002 and December 2014 at a single-institution. Postoperative complications occurred in 89 knees (83 patients, 5.6%), and 86 of them were found in females and 3 in males. Their mean age was 61 years (range, 46 to 81 years) at the time of initial UKA and 66 years (range, 46 to 82 years) at the time of revision surgery. We analyzed the complications after UKA retrospectively andinvestigated the proper methods of treatment (Table 1).

Results

A total of 89 complications (5.6%) occurred afterUKA. Regarding the type of complications after UKA, there were bearing dislocation (n=42), component loosening (n=23), 11 cases of femoral component loosening, 8 cases of tibial component loosening, and 4 cases of both femoral and tibial component loosening, periprosthetic fracture (n=6), polyethylene wear/ destruction (n=3), progression of arthritis to the other compartment (n=3), medial collateral ligament (MCL) injury (n=2), impingement (n=2), infection (n=5), ankylosis (n=1), and unexplained pain (n=2) (Table 2). The most common complication after UKA was mobile bearing dislocation in mobile-bearing type and loosening of prosthesis in fixed-bearing type, but polyethylene wear and progression of arthritis were relatively rare. The mean interval from UKA to the occurrence of complications was 4 years and 6 months (range, 0 [during operation] to 12 years). Of those complications following UKA, 58 knees were treated with conversion TKA, 1 with revision UKA, and 21 with simple bearing change. Complications in the remaining knees were treated with arthroscopic management (n=2), open reduction and internal fixation (n=3), closed reduction and internal fixation (n=1), manipulation (n=1), and MCL repair (n=2) (Table 3).

Discussion

In this single-center study, we reviewed the causes and types of complications (n=89) that occurred following UKA (n=1,576) and investigated optimal treatment methods. The incidence and type of complications were also compared among patients classified according to gender, medial/lateral UKA, and implant design and type. The strengths of this study include that all the patients were enrolled from the same institution and the sample size (UKA cases and complication cases) was relatively large compared to that in previous publications.

The most common complication following UKA was bearing dislocation in the mobile-bearing knees and component loosening in the fixed-bearing knees. The incidence of polyethylene wear and progression of arthritis to the other compartment was relatively low. The results of our study are in some discrepancy with those of studies involving Western patients. This can be attributed to the differences in patient characteristics such as lifestyle and in the type and design of implant used.

Conclusion

Thorough understanding of UKA, proper patient selection, appropriate implant choice are essential to reduce complications following UKA and obtain satisfactory outcomes. We suggest that complications following UKA should be treated differently according to the type and cause of complication and conversion TKA can be the most effective treatment when revision operation is determined necessary.