header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

CLINICAL RESULTS OF THA CEMENTED SOCKETS USING BONE CEMENT AND HA GRANULES: MODIFIED-IBBC

The International Society for Technology in Arthroplasty (ISTA), 28th Annual Congress, 2015. PART 4.



Abstract

Introduction

IBBC (interfacial bioactive bone cement method, Oonishi) (1) is an excellent technique for augmenting cement-bone fixation in the long term. However, the technique is difficult and there are concerns over some points, such as bleeding control, disturbance of cement intrusion to anchoring holes by granules, difficulty of the uniform granular dispersion to the acetabular bone (Zone 1 in particular). To improve this technique, we have modified IBBC (M-IBBC), and investigated the short-term clinical results and radiographic changes.

Materials and Methods

K-MAX HS-3 THA (Kyocera Medical, Japan), with cemented stem and all polyethylene cemented socket, was used for THA implants. Basically the third generation cementing technique was used for THA using bone cement. The socket fixation was performed with bone cement (Endurance, DePuy) and hydroxyapatite (HA) granules (Ca10(PO4)6(OH)2, Boneceram P; G-2, Olympus, Japan). In original IBBC technique, HA granules were dispersed on reamed acetabulum before cementing. In M-IBBC technique, HA granules were attached to bone cement on plastic plate, then inserted to reamed acetabulum and pressurized. HA granules (G-2) are 0.3–0.6mm in size, with 35–38% porosity and sintered at 1150â��. 51 hip joints (49 cases) were operated between June 2010 and December 2011, and followed. The average follow-up was 3.9 years, and average age at operation was 66.5 years. The clinical results were evaluated by Japan Orthopaedic Association Hip Score (JOA score), and X-p findings were evaluated using antero-posterior radiographs. The locations of radiolucent lines were identified according to the zones described by Delee and Charnley for acetabular components, and Zone 1 was divided into two parts, outer Zone 1a and inner Zone 1b.

Results and Discussion

Revision was not performed. Japanese orthopaedic association (JOA) score improved from 48 to 87. Socket and stem loosening was not observed. X-p findings of sockets demonstrated radiolucent line in Zone 1a/1b/2/3 in 2/0/0/0% immediately after the operation, 9.8/2/0/2% at 1 year postoperatively. After 1 year there was no progressive change, however, improvement of radiolucent line in Zone 1a was observed in two cases after 3 years postoperatively. Accordingly, after 3 years radiolucent line in Zone 1a/1b was observed in 5.9/2%.

Oonish has reported excellent clinical results of THA with IBBC (1). To easily perform IBBC, we have modified the technique, improving the problems of IBBC. In our previous report, we reported improvement of radiolucent line in IBBC (2). In this report, the similar radiographic behavior was observed in M-IBBC, which was not observed in conventional cementing technique. This finding suggests osteoconductive property of hydroxyapatite granules at the interface after the operations.

Conclusions

The interesting finding in M-IBBC cases was the improvement of radiolucent line, which was observed in IBBC cases. The promising long-term clinical results of M-IBBC method, similar to IBBC cases, were expected.


*Email: