header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Trauma

CLINICAL AND RADIOLOGICAL OUTCOMES OF COMPLEX TIBIAL PLATEAU FRACTURES TREATED WITH ILIZAROV FINE WIRE EXTERNAL FIXATORS

British Limb Reconstruction Society (BLRS) AGM & Instructional Course



Abstract

Introduction:

Bicondylar tibial plateau fractures are serious periarticular injuries. We investigated outcomes in injuries managed with Ilizarov external fixators.

Methods:

We retrospectively reviewed bicondylar tibial plateau fractures treated with Ilizarov fixators in a major trauma centre from 2008–2012. Radiological parameters were measured from standardised weight-bearing radiographs. A subset (n=34) had patient-related outcome measures.

Results:

Of 80 injuries, all fractures united. Two developed septic arthritis and one osteomyelitis. 76.3% were graded a good-excellent outcome (Rasmussen radiological score). 30.3% had evidence of osteoarthritis (Kellgren Lawrence>1). Neither parameter correlated significantly with lower functional scores. Referrals from neighbouring hospitals had longer times to surgery, which associated with increased condylar widening (p=0.0214) and posterior tibial slope (p=0.0332). Risk of developing osteoarthritis correlated with lower joint line congruency angle (JLCA) (p=0.0017) and increased articular step-off (p=0.0008) on initial radiographs. 3 patients have progressed to total knee arthroplasty.

Discussion and Conclusion:

This is the largest study of bicondylar tibial plateau fractures treated by Ilizarov fixation. Rates of septic arthritis and osteomyelitis compare with previously reported rates, with no cases of non-union. Over 76% achieved good-excellent radiological outcome, compared with 63–96% in studies of internal fixation. Achieving normal JLCA and smooth articular surface at the time of fixation reduce risk of developing osteoarthritis.