General Orthopaedics

Osteochondral fractures of the knee in skeletally immature patients: short term results of operative fixation using Omnitech screws

British Orthopaedic Association 2012 Annual Congress



Abstract

Introduction

Osteochondral defects of the knee may occur following patella dislocation or following direct trauma or twisting injuries to the knee in adolescents. Often a diagnostic and therapeutic challenge, if these lesions are left, posttraumatic osteoarthritis may occur. This retrospective single centre study presents the short-term results following operative fixation of osteochondral fragments of the knee using Omnitech ® screws.

Method

All skeletally immature patients presenting with an osteochondral fracture of their femur or patella confirmed on xray and MRI were identified. Arthroscopic evaluation of the osteochondral defect was performed followed by open reduction and internal fixation of the osteochondral fragment using Omnitech ® screws. A standard postoperative rehabilitation protocol was followed. Patients were evaluated at follow-up using a Knee Injury and Osteoarthritis Outcome Score (KOOS).

Results

Eight patients were identified. The mean age at time of injury was 15 years (range 14–16) for two girls and 14.4 years (range 13–16) for six boys. The lateral femoral condyle was involved in six cases and patella in two cases. At mean follow up of 14 months (range 1–38) there was no revision for failure and no postoperative complications. The KOOS score (out of 100) at final follow up was subdivided as follows; Pain, 93 (range 81–100), other symptoms, 77 (range 36–100), function in daily living (ADL), 97 (range 84–100), function in sport and recreation, 84 (range 55–100) and knee related quality of life, 79 (range 44–100).

Discussion

The short-term results of using Omnitech® screws are promising. Subchondral screw placement with adequate compression of the osteochondral fragment is achievable with Omnitech ® screws. Seven patients are back to their pre-injury sporting activity and one patient is currently undergoing postoperative rehabilitation, one month following surgery.