DOES A SINGLE HAEMOCUE TEST REDUCE THE NEED FOR EXTENSIVE PREOPERATIVE BLOOD TESTS AND THEIR ASSOCIATED COSTS IN ELECTIVE ARTHROPLASTY?

The 27th Annual Meeting of the European Orthopaedic Research Society (EORS), Maastricht, The Netherlands, 2–4 October 2019.



Abstract

Pre-operative anaemia can present in up to 30% of elective arthroplasty patients. The presence of anaemia increases the risk of requiring blood transfusion post-operatively as well as acts as an independent risk factor for poor outcome such as prosthetic joint infection. Recent international consensus on this topic has recommended a specific care pathway for screening patients with pre-operative anaemia using a simple bedside Heaemacue finger-prick test to detect in a simple and cost-effective manner, and then allow treatment of preoperative anaemia. This pathway was therefore incorporated in our trust.

This was a retrospective study done at a single tertiary-referral arthroplasty centre. Our data collection included the Heamacue test results and formal haemoglobin levels if they were performed as well as compliance and costs of each of the tests for patients listed for an elective shoulder, hip and knee arthroplasty between September and December 2018. Medical records and demographics were also collected for these patients for subgroup analysis. Our exclusion criteria comprised patients listed for revision arthroplasty surgery.

87 patients were included in this study. Our compliance rate was 15%. The mean difference between a Haemacue test and a formal FBC result was only 17.6g/L suggesting that it has a reasonably high accuracy. With regards to costs, we found that a Haemacue test costs £2, compared to £7.50 for a full blood count and Haematinics combined. This gave an overall cost saving of £5.50 per patient. Extrapolation of this date locally for 2017 at our hospital, where 1575 primary joint arthroplasties were done, a cost saving of £8,662.5 could have been achieved. Within the UK using data extrapolated from the National Joint Registry a total of £1,102,205.5 (1,221,894 Euros) could have been saved.

The use of a single, Haemacue test to screen for pre-operative anaemia in elective arthroplasty patients is more cost effective compared to a formal full count and haematinics tests. However, we found that compliance with the care pathway is variable due to system limitations. This may be addressed through implementing changes to our electronic system in which patients are booked for surgery. We also noted a significant cost reduction if this pathway were to be used Nation-wide. Thus, we encourage other centres to consider the use of the Haemacue test pre-operatively in elective arthroplasty instead of formal full blood counts at the time of decision to treat with arthroplasty; this allows sufficient time for correction of pre-operative anaemia thus improving patient outcomes from arthroplasty.