EXTERNAL THERMOPLASTIC RINGS RESTORE NEAR-NORMAL FLEXOR TENDON BIOMECHANICS FOLLOWING VENTING OF THE PULLEYS

The Canadian Orthopaedic Association (COA) and Canadian Orthopaedic Research Society (CORS) Virtual Annual Meeting 2020, held online, 19–20 June 2020.



Abstract

Normal digital flexion relies on flexor tendon pulleys to transmit linear muscular force to angular digital motion. Despite the critical role these pulleys play, there is a growing trend among surgeons to partially sacrifice or “vent” them during flexor tendon repair to improve surgical exposure. Although this new practice is reported to improve outcomes after flexor tendon repair, there is concern for the long-term effects of bowstringing, reduced finger range of motion (ROM) and altered tendon biomechanics. The objective of this study was to examine the effects of the application of a thermoplastic ring, acting as an “external” pulley, on flexor tendon biomechanics and finger ROM. We hypothesized that the application of an external thermoplastic ring would produce a centripetal force over the tendon to reduce bowstringing, improve finger ROM, and restore tendon loads following pulley venting

Twelve digits comprised of the index, long, and ring fingers from four cadaveric specimens were tested using a novel in-vitro active finger motion simulator. Servo-motors were used to generate motion. Loads induced by flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP), and joint range of motion were measured with each sequential sectioning of the A2, A3, and A4 flexor pulley, in comparison to a native healthy finger condition. At each finger condition, A2 and A4 external thermoplastic pulley rings were applied over the proximal phalanx and middle phalanx, respectively, to recreate A2 and A4 function. Results were recorded and analyzed using a one way repeated-measures ANOVA.

Following venting of the A2, A3 and A4 pulley, proximal interphalangeal joint (PIPJ) ROM significantly decreased by 17.02 ± 8.42 degrees and distal interphalangeal joint (DIPJ) range of motion decreased by 17.25 ± 8.68 degrees compared to intact pulleys. Application of the external rings restored range of motion to within 8.14 ± 8.17 degrees at the PIPJ and to within 7.72 ± 8.95 degrees at the DIPJ. Similarly, pulley venting resulted in a 36% reduction in FDS load and 50% in FDP load compared to intact pulleys. Following application of the external rings, loads were almost restored to normal at 7% reduction for FDS load and 13% reduction for FDP load.

Venting of flexor tendon pulleys significantly alters flexor tendon biomechanics and digit range of motion. The application of thermoplastic rings acting as external pulleys over the proximal and middle phalanges is an effective, inexpensive, non-invasive and reproducible therapeutic method to restore flexor tendon biomechanics and digit range of motion.