header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Hip

TRABECULAR METAL CUP-CAGE CONSTRUCT IN IMMEDIATE TOTAL HIP ARTHROPLASTY FOR OSTEOPOROTIC ACETABULAR FRACTURES

British Hip Society (BHS) Meeting, Derby, England, March 2018



Abstract

Introduction

Severely comminuted, displaced acetabular fractures with articular impaction in the elderly population present significant treatment challenges. To allow early post-operative rehabilitation and limit the sequelae of immobility, treatment with acute total hip replacement (THA) has been advocated in selected patients. Achieving primary stability of the acetabular cup without early migration is challenging and there is no current consensus on the optimum method of acetabular reconstruction. We present clinical results and radiostereometric analysis of trabecular metal (TM) cup cage construct reconstruction in immediate THA without acetabular fracture fixation.

Methods

Between 2011 and 2016, twenty-one acetabular fractures underwent acute THA with a TM cup cage construct. Patient, fracture and surgical demographics were collected. They were followed up for a mean of 24months (range 12–42months). Clinical and patient reported outcome measures were collected at regular post-operative intervals. Radiosterometric analysis (RSA) was used to measure superior migration and sagittal rotation of the acetabular component.

Results

Thirteen fractures were classified as anterior column posterior hemi-transverse, two anterior column, two transverse and four associated both column acetabular fractures. There was one case of trochanteric fracture and transient foot drop. Mean Harris Hip Scores at 12months was 79 (range 33–98). The mean proximal migration of the acetabular components at 12months was 0.91mm (range 0.09–5.12 and mean sagittal rotation was 0.52mm (range 0.03–7.35).

Conclusion

The TM cup-cage technique requires a single approach and provides immediate cup stability allowing full weight bearing day one post-op. To our knowledge this is the first study to accurately measure cup stability following THA for an acetabular fracture. Our promising early clinical and radiological outcomes suggest this technique may be an alternative to a fix and replace construct for immediate THA for acute acetabular fractures in the elderly.


Email: