USE OF DUAL MOBILITY IN DISPLACED INTRACAPSULAR FRACTURES THROUGH THE POSTERIOR APPROACH: A CASE-MATCHED REVIEW OF ONE-YEAR DISLOCATION RATES

British Hip Society (BHS) Meeting, Derby, England, March 2018



Abstract

Fractured neck of femur is a significant health concern within the UK. NICE guidance on the management of displaced intracapsular fractures states that total hip arthroplasty should be offered when patients can; walk independently out of doors with no more than a stick, not cognitively impaired, medically fit for anaesthesia and the procedure. We previously managed this subgroup using THA with standard sockets. Following an audit of this practice a dislocation rate of 9% was identified and practice was changed to using dual mobility (THA-DM) with the theoretical advantage of reducing dislocation.

We reviewed all patients who underwent THA for fracture using Bluespier from 2013–2017. Operative notes and radiographs were reviewed to ensure the patients had undergone THA for displaced intracapsular fracture. Basic patient demographics were collected. Our primary outcome was dislocation rates at one year. Our secondary outcomes were length of time to surgery, length of stay, operative time, mortality, return to theatre rates and one year Oxford hip scores

We found a control group of 45 THA procedures and a dual mobility group of 143 procedures. The one year dislocation rate from the THA-SS group was 9% and the THA-DM group was 1.4%(CI±1.9%)(p=<0.05%). There were also non-significant reductions in time to surgery, length of stay, operative time, mortality, return to theatre rates. The one year Oxford hip score was comparable at 42.2 to 41.8.

This study demonstrates a significant reduction in one year dislocation rates with comparable oxford hip scores. Use of THA-DM should be considered in those patients who meet NICE criteria. Further research is needed into long term dislocation rates.