Abstract

Highly porous tantalum cups have been used in complex acetabular revisions for nearly 20 years but reports of long term results are limited. This study was designed to report ten year results of revision using a single porous tantalum cup design with special attention to re-operation for any reason, all-cause revision, and revision for aseptic loosening.

Retrospective review of all revision THA cases performed from 1999–2006 using a highly porous tantalum acetabular component design with multiple screw holes and a cemented polyethylene liner (Zimmer Biomet, Warsaw, IN). Our institutional medical record and total joint registry were used to assess follow-up and xrays were reviewed. The Paprosky classification system was used to rate acetabular bone loss. Radiographic loosening was defined as new/progressive radiolucencies in all 3 acetabular zones, or cup migration (>2mm). Kaplan-Meier survivorship was used to assess survivorship free of cup revision/removal for any reason, and free of revision for aseptic loosening.

Between 1999 and 2006 this tantalum cup was used in 916 revisions. Mean age: 66 (±6), BMI: 29 (±6), and male: 42%. Indications for revision: aseptic loosening 346 (38%), osteolysis 240 (26%), and infected arthroplasty 168 (18%). Large (3A or 3B) bone defects were present in 260, and pelvic discontinuity in 61. Reoperation for any reason: 133 (15%), but 84 of 133 cases did not require cup revision for instability (38) or femoral failure (24). Tantalum cup removal/revision was required in 49 (5.3%) for deep infection (39) and recurrent dislocation (6), and aseptic loosening (4). 10 year survivorship free of cup revision for any reason: 95% and for aseptic loosening: 99%. Radiographic review (mean 10 years): suspicious for aseptic loosening in another 4 cups.

A highly porous tantalum acetabular component with multiple screws and a cemented polyethylene insert provided durable long term fixation for an array of acetabular revision problems. Long term aseptic loosening was very rare (<1%) and cup removal was mainly related to deep infection, and rarely dislocation.