Foot & Ankle

Functional outcomes of conservatively managed acute ruptures of the Achilles tendon



Download PDF

Abstract

Aims

This prospective cohort study aims to determine if the size of the tendon gap following acute rupture of the Achilles tendon shows an association with the functional outcome following non-operative treatment.

Patients and Methods

All patients presenting within two weeks of an acute unilateral rupture of the Achilles tendon between July 2012 and July 2015 were considered for the study. In total, 38 patients (nine female, 29 male, mean age 52 years; 29 to 78) completed the study. Dynamic ultrasound examination was performed to confirm the diagnosis and measure the gap between ruptured tendon ends. Outcome was assessed using dynamometric testing of plantarflexion and the Achilles tendon Total Rupture score (ATRS) six months after the completion of a rehabilitation programme.

Results

Patients with a gap ≥ 10 mm with the ankle in the neutral position had significantly greater peak torque deficit than those with gaps < 10 mm (mean 23.3%; 7% to 52% vs 14.3%; 0% to 47%, p = 0.023). However, there was no difference in ATRS between the two groups (mean score 87.2; 74 to 100 vs 87.4; 68 to 97, p = 0.467). There was no significant correlation between gap size and torque deficit (τ = 0.103), suggesting a non-linear relationship. There was also no significant correlation between ATRS and peak torque deficit (τ = -0.305).

Conclusion

This is the first study to identify an association between tendon gap and functional outcome in acute rupture of the Achilles tendon. We have identified 10 mm as a gap size at which deficits in plantarflexion strength become significantly greater, however, the precise relationship between gap size and plantarflexion strength remains unclear. Large, multicentre studies will be needed to clarify this relationship and identify population subgroups in whom deficits in peak torque are reflected in patient-reported outcome measures.

Cite this article: Bone Joint J 2017;99-B:87–93.